Professional Documents
Culture Documents
zp01
Catalog HY28-2662-CD/US
Catalog HY28-2662-CD/US
Introduction
78.7 (20.8) 118.1 (31.2) 77 (75) 119.6 (31.6) 179.8 (47.5) 83 (77)
* Since many variables such as mounting, tank style, plant layout, etc., effect noise levels, it cannot be assumed that the above readings will be equal to those in the field. The above values are for guidance in selecting the proper pump. Noise levels are A-weighted, mean sound pressure levels at 1 meter from the pump, measured and recorded in accordance with applicable ISO and NFPA standards. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA
Catalog HY28-2662-CD/US
Introduction
PUMP HOUSING
HYDRODYNAMIC BEARING
REAR COVER
SEALED BEARING
SHAFT SEAL
CYLINDER BARREL
SERVO PISTON
Features
High Strength Cast-Iron Housing Built-In Supercharger Ensures High Speed Capability - 3000 RPM (2600 RPM PAVC100) Sealed Shaft Bearing Two Piece Design for Ease of Service Cartridge Type Controls - Field Changeable Replaceable Bronze Clad Port Plate Airbleed Standard for Quick Priming Hydrodynamic Cylinder Barrel Bearing Thru-Shaft (PAVC100 Only) Full Pressure Rating on Most Water Glycol Fluids Pump Case and Shaft Seal are Subjected to Inlet Pressure Only Filter and/or Cool Drain Line 7 bar (100 PSI) Maximum
Controls
Pressure Compensation Load Sensing Power (Torque) Limiting Power and Load Sensing Remote Pressure Compensation Adjustable Maximum Volume Stop Electrohydraulic Flow and Pressure Low Pressure Standby
Catalog HY28-2662-CD/US
the swash plate. When the swash plate is in a vertical position, perpendicular to the centerline of the piston barrel, there is no piston stroke and consequently no fluid displacement. When the swash plate is positioned at an angle, the pistons are forced in and out of the barrel and fluid displacement takes place. The greater the angle of the swash plate, the greater the piston stroke. The centerline of the pumping piston assembly is offset from the centerline of the swash plate. Therefore, as shown on the accompanying Figure 1A, the pistons effective summation force tends to destroke the swash plate to a vertical (neutral) position. This destroking force is balanced as the swash plate is angled by the force of the servo piston.
PUMPING PISTON
OUTPUT
DRIVE SHAFT
INPUT
SWASH PLATE
FIGURE 1A.
Catalog HY28-2662-CD/US
compensator control setting, the control spool moves up, bringing the pump to maximum displacement.
PISTON
OUTLET D
PRESSURE
INLET
BARREL
PISTON
SERVO PISTON
F CONTROL DRAIN PORT A PRESSURE COMPENSATOR ADJUSTMENT CONTROL SPOOL SPRING CHAMBER DIFFERENTIAL ADJUSTMENT
Catalog HY28-2662-CD/US
Multiple Pressure Standby If the pressure level in the low signal B port is limited by a relief valve, as the desired pump outlet pressure is reached, the relief valve in the B port will allow the pump to standby at a preset pressure. Adding to this concept, multiple, remotely piloted relief valves plumbed in parallel in the B port line can yield multiple, sequential pressure settings. Electrohydraulic Pressure & Flow Control A proportional pressure control valve can be used in place of relief valves to give variable pressure control proportional to an electrical input signal to the valve. By combining this arrangement with a swash plate position sensing device, amplifier, and logic circuit, servo control of pressure and/or flow is achieved. NOTE: In most systems, a load equivalent to the minimum operating pressure of the pump cannot be guaranteed. Because of this, a sequence valve is required in the discharge line to maintain servo flow control. Please refer to ordering information section for servo components.
CONTROL OPTION - M
SWASHPLATE AIRBLEED VALVE ASSEMBLY
PRESSURE
PISTON
OUTLET D
INLET
BARREL
PISTON
SERVO PISTON
PORT B F CONTROL DRAIN PORT A PRESSURE COMPENSATOR ADJUSTMENT CONTROL SPOOL SPRING CHAMBER DIFFERENTIAL ADJUSTMENT
Catalog HY28-2662-CD/US
CONTROL OPTION - A
SWASHPLATE AIRBLEED VALVE ASSEMBLY FLOW CONTROL ADJUSTMENT
FLOW (AT CONSTANT SPEED)
PISTON
SYSTEM PRESSURE
PRESSURE
INLET
BARREL
PISTON
C
SERVO PISTON
PORT B F CONTROL DRAIN PORT A PRESSURE COMPENSATOR ADJUSTMENT CONTROL SPOOL SPRING CHAMBER DIFFERENTIAL ADJUSTMENT
Catalog HY28-2662-CD/US
spool to move downward, venting the servo piston cavity and causing the servo piston to move to the right. This reduces output flow and thereby power. As indicated in the pictorial drawing, pressure in the control spool chamber is affected by both the pressure compensator control and the power control. The resultant pressure in this chamber is a function of the set points of these two controls. Both set points are adjustable.
CONTROL OPTION - H
SWASHPLATE AIRBLEED VALVE ASSEMBLY
PRESSURE
PISTON
OUTLET D
INLET
BARREL
PISTON
SERVO PISTON
F CONTROL DRAIN PORT A POWER (TORQUE) ADJUSTMENT PRESSURE COMPENSATOR ADJUSTMENT CONTROL SPOOL SPRING CHAMBER DIFFERENTIAL ADJUSTMENT
Catalog HY28-2662-CD/US
FLOW
LPM GPM 60.6 (16) 53.0 45.4 (14) (12) (10) (8) (6) (4) (2) (0) Bar 0 PSI (0)
1800 RPM
KW HP 18.6 (25) Nm In-Lbs 90.4 (800) 14.9 (20)
Input Power
11.2 (15)
45.2 (400)
7.5
(10)
3.7
(5)
22.6 (200)
(0)
(0)
Pressure
POWER
1. Power A curve corresponds to flow A curve. This represents a particular setting of the power (torque) control. 2. With this setting the maximum power required will be as shown at the apex (maximum point) of the power curve. 3. The flow at this setting will follow the flow vs. pressure curve shown. 4. Example 1800 RPM, curve labeled C: A. Flow will follow curve C and pump will deadhead at 190 bar (2750 PSI). B. Full flow will not be realized above 83 bar (1200 PSI). C. Flow at 103 bar (1500 PSI) will be approximately 48.1 LPM (12.7 GPM). D. Maximum power [11 KW (15 HP)] occurs at approximately 117 bar (1700 PSI). 5. Torque values are shown to correspond to powers at speed shown.
Input Torque
67.8 (600)
Flow
Catalog HY28-2662-CD/US
PRESSURE
CONTROL OPTION - C
SWASHPLATE AIRBLEED VALVE ASSEMBLY FLOW CONTROL ADJUSTMENT
PISTON
SYSTEM PRESSURE
INLET
BARREL
PISTON
C
SERVO PISTON
PORT B F CONTROL DRAIN PORT A POWER (TORQUE) ADJUSTMENT PRESSURE COMPENSATOR ADJUSTMENT CONTROL SPOOL SPRING CHAMBER DIFFERENTIAL ADJUSTMENT
10
Catalog HY28-2662-CD/US
11
Catalog HY28-2662-CD/US
Features
High Strength Cast-Iron Housing Built-In Supercharger High Speed Capability 3000 RPM Two Piece Design for Ease of Service Cartridge Type Controls Field Changeable Replaceable Bronze Clad Port Plate Airbleed Standard for Quick Priming Hydrodynamic Cylinder Barrel Bearing Full Pressure Rating on Water Glycol Fluids Filtered and/or Cooled Drain Line Capable 7 bar (100 PSI) Maximum
Specifications
Pressure Ratings: Outlet Port: Inlet Port: 207 bar (3000 PSI) Continuous (P1) 248 bar (3600 PSI) Peak (P3) 1.72 bar (25 PSI) Maximum 0.17 bar (5 In. Hg.) Minimum @ 1800 RPM (See Inlet Chart for other speeds) 7 bar (100 PSI) Maximum
Controls
Pressure Compensation Remote Pressure Compensation Load Sensing Power (Torque) Limiting Power Limiting and Load Sensing Adjustable Maximum Volume Stop Electrohydraulic Flow and Pressure Low Pressure Standby
Control Drain:
Speed Ratings: 600 to 3000 RPM Operating Temperature Range: 40C to 71C ( 40F to 160F)
Schematic Symbol
(Basic Pump)
Housing Material: Cast-Iron Filtration: Maintain SAE Class 4, ISO 16/13, ISO 18/15 Maximum Recommended Mounting: SAE B 2-Bolt Flange Mount or Diagonally on SAE B 4-Bolt Flange Mount.
PAVC 33/38
18 (40)
18.41 (7.25)
Installation Data: See page 46 of this catalog for specific recommendations pertaining to system cleanliness, fluids, start-up, inlet conditions, shaft alignment, drain line restrictions and other important factors relative to the proper installation and use of these pumps.
* Since many variables such as mounting, tank style, plant layout, etc., effect noise levels, it cannot be assumed that the above readings will be equal to those in the field. The above values are for guidance in selecting the proper pump. Noise levels are A-weighted, mean sound pressure levels at 1 meter from the pump, measured and recorded in accordance with applicable ISO and NFPA standards.
12
Catalog HY28-2662-CD/US
Ordering Information
PAVC
Multiple Pumps Pump Axial Piston Variable Controllable Displacement Bearing Option Shaft Outlet Inlet Rotation Differential Control Option Volume Stop Control Options Seals Paint
Code Multiple Pumps Omit Single Pump Factory Mounted to Rear of Another Pump Code Painting Omit No Paint P Paint
Code Omit 9*
Code Omit 4
Code Omit
* For applications where side loading may be experienced. Max. side load = 104 kg (230 lbs). Typical Applications: Belt/chain drive Universal joint drive Massive couplings Foot mount installations
Code Omit 2 5
Volume Stop Options Volume Stop Plugged Maximum Volume Stop Max. Vol. Stop with O-Ring Code
Omit A *C *H
**M
Control Options
Standard Pressure Compensated Setting Pressure 28-207 bar (400-3000 PSI) Pressure & Flow (Load Sensing) Pressure, Flow & Power (Torque) Limiting Pressure & Power (Torque) Limiting Remote Pressure Remote Pressure Servo Pressure & Volume (Requires PPC, Amplifier & Seq. Valve) Servo Pressure & Volume (Requires PPC, Amplifier & Seq. Valve) Remote Pressure & Flow Remote Pressure, Flow & Power Remote Pressure & Power
Code Omit B S*
Shaft Option 7/8" Keyed (SAE B) 13T Spline (SAE B) 7/8" Keyed, Short Shaft (SAE B)
**ME
Code Outlet
Omit Str. Thd.
Port Location
Top
Type
SAE/Inch
Code Inlet
Omit 2 8 Str. Thd. Flange Flange
Port Location
Rear Side Side
SE
Type
SAE/Inch Threads SAE/Inch Threads ISO 6149/Metric
AM *CM *HM
Ordering Notes
Unless otherwise specified, pump is shipped at maximum GPM (1800 RPM) and set to 69 bar (1000 PSI) [See Exceptions]. When factory settings are required, the items shown in Chart #1 must be included with order.
Chart #1 Item
RPM PSI HP GPM
* Power controlled pumps (H, C, HM or CM) must have maximum input power limit specification at a particular drive speed (RPM), and compensator pressure (PSI) included with order. Power controlled pumps that do not have input power limit specifications, will be set at a default setting. (7.5 HP @ 1800 RPM and 1000 PSI) H & C (20 HP @ 1800 RPM and 3000 PSI) HM & CM
Pumps with M, ME, S, SE, AM, CM or HM controls will be set to compensate at 207 bar (3000 PSI) unless Chart #1 otherwise specifies.
13
Catalog HY28-2662-CD/US
Performance Data
Typical Performance Data - Fluid: Standard Hydraulic Oil 100 SSU @ 49C (120F)
PAVC33 @ 1800 RPM
LPM GPM
Volumetric Efficiency
Volumetric Efficiency
fficie ncy
Efficiency - %
90 80 70 60
Overall Efficiency
Efficiency - %
100
113.6 (30)
100 90 80 70 60
113.6 (30) 102.2 (27) 90.9 (24) 79.5 (21) 68.1 (18) KW HP 26.1 (35.0)
all E Over
Flow
Flow
57.8 (15) 45.4 (12) 34.1 22.7 11.4 (9) (6) (3)
Flow
Flow
r we Po Flow t pu ll In t Fu a
Power
Compen
69 (1000)
sate
d Power
Compen
69 (1000)
sated Po
138 (2000)
wer
138 (2000)
Pressure
Pressure
NOTE: The efficiencies and data in the graph are good only for pumps running at 1800 RPM and stroked to maximum. To calculate approximate input power for the other conditions, use the following formula: HP =
WHERE: Q = Actual Output Flow in GPM PSI = Pressure At Pump Outlet CHp = Input Power @ Full Compensation @ 1800 RPM (from graph read at operating pressure)
Q x (PSI) 1714
+ (CHp)
Actual GPM is directly proportional to drive speed and maximum volume setting. Flow loss, however, is a function of pressure only.
4.5 (1.2)
Drain Flow
.14
3.4
(.9)
2.3
(.6)
1.1
(.3)
69 (1000)
138 (2000)
207 (3000)
System Pressure
Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA
14
Power
er ow ow t P Fl pu ll In t Fu a
14.9 (20.0)
Catalog HY28-2662-CD/US
Performance Data
Typical Performance Data Minimum Power Settings Attainable With Control Options C, H, CM & HM
PAVC33
KW HP 22.4 (30)
17.9
(24)
172 bar (2500 PSI) Comp. Setting 138 bar (2000 PSI) Comp. Setting
Power
13.4
(18)
113.6 (30.0)
8.9
(12)
75.7 (20.0)
4.5
(6)
37.9 (10.0)
(0)
0 500 1000 1500 2000 2500 3000
(0) 0
500
1000
1500
2000
2500
3000
NOTE: Minimum attainable HP setting means that input power will not exceed the indicated setting at the indicated RPM and that the pump will achieve full compensator pressure selected. If setting input power limiter below full flow boundary, full flow may not be obtained at low operating pressure.
Determine maximum input power limitation at desired RPM. All points above desired compensator setting curve can be achieved.
14.9 (20)
Input Power
Input Power
Input Torque
67.8
(600)
45.2
11.2 (15)
7.5
(10)
45.2
(400)
45.2
(400)
7.5
(10)
3.7
(5)
22.6
(200)
3.7
(5)
22.6
(200)
(0)
(0)
(0)
(0)
69 (1000)
138 (2000)
207 (3000)
69 (1000)
138 (2000)
207 (3000)
Pressure
Pressure
15
Input Torque
53.0
67.8
(600)
Flow
Flow
Catalog HY28-2662-CD/US
Performance Data
Typical Performance Data Minimum Power Settings Attainable With Control Options C, H, CM & HM
PAVC38
KW HP 22.4 (30)
17.9
(24)
Power
13.4
(18)
8.9
(12)
138 bar (2000 PSI) Comp. Setting Full Flow Boundary 103 bar (1500 PSI) Comp. Setting 69 bar (1000 PSI) Comp. Setting
113.6
(30)
75.7
(20)
4.5
(6)
37.9
(10)
(0)
0 500 1000 1500 2000 2500 3000
NOTE: Minimum attainable HP setting means that input horsepower will not exceed the indicated setting at the indicated RPM and that the pump will achieve full compensator pressure selected. If setting input power limiter below full flow boundary, full flow may not be obtained at low operating pressure.
Determine maximum input power limitation at desired RPM. All points above desired compensator setting curve can be achieved.
Input Power
Input Torque
18.6 (25)
37.8
(10)
45.2 (400)
22.6 (200)
18.9
(5)
7.5 (10) 3.7 (5) 0 (0) 69 (1000) 138 (2000) 207 (3000)
Pressure
Pressure
16
Input Torque
67.8 (600)
Input Power
Flow
Flow
Catalog HY28-2662-CD/US
NOTE: 1. Pump shown and dimensioned is a clockwise rotation pump. Outlet port, A and B ports, and controls will be on opposite side for a counterclockwise rotation pump.
INLET PORT 1-5/8-12UN-2B ST. THREAD O-RING SAE-20 63.50 (2.50) 31.75 (1.25)
VARIABLE VOLUME PUMP CC/REV ROTATION
OUTLET PORT 1-1/16-12UN-2B ST. THREAD O-RING SAE-12 25.40 SHAFT OPTION (1.00) OMIT SAE B SHAFT 7/8" KEYED MAX. TORQUE 31.75 = 209 Nm (1.25) (1,850 IN-LBS)
25.40 (1.00)
LOW SIGNAL PORT B 7/16-20UNF-2B ST. THREAD O-RING SAE-4 12.70 (.50) 20.57 (.81) TORQUE CONTROL ADJUSTMENT: 56 Nm (500 IN-LB) PER TURN PRESSURE COMPENSATOR ADJUSTMENT: 55 BAR (800 PSI) PER TURN
98.55 (3.88)
Rear View
CLEARANCE FOR .500 DIA. MOUNTING BOLTS. SAE B 2-BOLT PATTERN CLEARANCE FOR .500 DIA. BOLTS MOUNTED DIAGONALLY ON SAE B 4-BOLT PATTERN 6.35 (.250) WIDE KEY 25.09 (.988) 24.73 (.974) 101.60 (4.000) 101.54 (3.998)
Top View
184.15 (7.25) OPTIONAL LOW SIGNAL PORT (PORT B) B 41.40 (1.63) ROTATION ARROW
44.45 (1.75)
74.68 (2.94) 18.79 (.74) 65.28 (2.57) AIRBLEED DRAIN PORT 7/16-20UNF-2B ST. THREAD O-RING SAE-4 35 ADJUSTABLE DIFFERENTIAL OPTION 4 SENSITIVITY: 13.8 BAR (200 PSI) PER TURN CONTROL DRAIN PORT A 7/16-20UNF-2B ST. THREAD O-RING SAE-4 25.40 (1.00) 41.15 (1.62) A
115.06 (4.53)
Side View
SHAFT OPTION S SAE B SHORT SHAFT 7/8" KEYED MAX. TORQUE = 209 Nm (1,850 IN-LBS)
Front View
SHAFT OPTION B SAE B SPLINED SHAFT 13 TOOTH 16/32 PITCH MAX. TORQUE = 209 Nm (1,850 IN-LBS)
61.97 (2.44) MAX MAX.VOLUME STOP OPTION 5 2.5 CC/REV/TURN (PAVC33) 2.8 CC/REV/TURN (PAVC38)
17
Catalog HY28-2662-CD/US
NOTE: 1. Shown and dimensioned is a clockwise pump. Ports A and B, delivery port and pump controls will be on the opposite side for a counterclockwise pump.
105.92 (4.17) 89.66 (3.53)
OUTLET PORT SEE CHART FOR SIZE 25.40 (1.00) SHAFT OPTION OMIT SAE B SHAFT 7/8" KEYED MAX. TORQUE 31.75 (1.25) = 209 Nm (1,850 IN-LBS)
25.40 (1.00)
63.50 (2.50)
CC/REV PSI MAX INITIAL FACTORY SETTINGS BELOW HP GPM PSI HYDRAULIC PUMP/MOTOR DIVISION OTSEGO,MICH. 49078 USA
ROTATION
RPM
LOW SIGNAL PORT B SEE CHART FOR SIZE 12.70 (.50) 20.57 (.81) CLEARANCE FOR .500 DIA. MOUNTING BOLTS. SAE B 2-BOLT PATTERN CLEARANCE FOR .500 DIA. BOLTS MOUNTED DIAGONALLY ON SAE B 4-BOLT 58.67 PATTERN (2.31) 9.37 6.35 (.250) (.37) WIDE KEY 25.09 (.988) 24.73 (.974) 101.60 (4.000) 101.54 (3.998) 22.22 (.875) 22.19 (.874) 63.50 (2.50) TORQUE CONTROL ADJUSTMENT: 56 Nm (500 IN-LB) PER TURN PRESSURE COMPENSATOR ADJUSTMENT: 55 BAR (800 PSI) PER TURN
Rear View
89.41 (3.52) 72.89 (2.87) 63.50 (2.50) 89.66 (3.53) 72.89 (2.87) 63.50 (2.50)
Top View
185.93 (7.32)
INLET PORT SAME BOTH SIDES SEE CHART FOR SIZE 89.66 (3.53)
74.68 (2.94)
58.93 (2.32) 65.28 (2.57) AIRBLEED DRAIN PORT 7/16-20 UNF-2B ST. THREAD O-RING SAE-4 OPTION 8 ISO 6149-4 ADAPTER FITTING ON OPTION 8 35 18.79 (.74)
CONTROL DRAIN PORT A 25.40 SEE CHART (1.00) FOR SIZE 41.15 (1.62)
30.23 (1.19)
Front View
115.06 (4.53)
ADJUSTABLE DIFFERENTIAL OPTION 4 SENSITIVITY: 13.8 BAR (200 PSI) PER TURN
Side View
MAX.VOLUME STOP OPTION 2 SHAFT OPTION S 2.2 CC/REV/TURN (PAVC33) SAE B SHORT SHAFT 2.5 CC/REV/TURN (PAVC38) 7/8" KEYED MAX. TORQUE = 209 Nm (1,850 IN-LBS) SHAFT OPTION B 61.97 SAE B SPLINED SHAFT (2.44) 13 TOOTH MAX 16/32 PITCH MAX. TORQUE = MAX.VOLUME STOP OPTION 5 209 Nm 2.5 CC/REV/TURN (PAVC33) (1,850 IN-LBS) 2.8 CC/REV/TURN (PAVC38)
18
Catalog HY28-2662-CD/US
* = Length in Feet
FEEDBACK CONNECTOR MS3102R14S-2PY MATES WITH MS3106A14S-2SY (PART NO. 800722) ELECTROHYDRAULIC CABLE CAN BE ORDERED AS EHC*4Y*
150.37 (5.92)
OUT
GND
+10
1. Consult factory for information relative to pump option selection and additional components required for desired pump function. 2. For electrohydraulic flow and pressure control of one or two pumps, make electrical connections per Figure IV. When one pump is used, omit connections to pump #2 feedback. 3. For electrohydraulic flow only, eliminate pressure command signal and place jumper between Press CMD and +10V terminals (compensating pressure will be controlled by maximum setting on pump or remote compensator if used). 4. For electrohydraulic pressure only, eliminate volume command signal and place jumper between VOL CMD and +10V terminals or use 801179 pressure driver card. 5. Figures I thru III show nominal input vs. output relationships. The actual values will vary with component tolerances. Full volume range will be realized with 0 to 7 volts. Full pressure range will be realized with 0 to 7 volts, or 0-500MA. 6. Pump shown is a clockwise rotation. For a counterclockwise rotation LVDT feedback is on opposite side. 7. For further detail on installation of AP11/AP211, refer to the latest edition of Catalog 2600-400-x/US.
PRESS CMD
NOTES:
L1 L2
VOL CMD
D C B A D C B A
D C B A Volume Command PPC Valve Signal 693705 Pipe 694586 St. Thd. 786645-3000 PSI
D C B A
Pump #2 Feedback (if used)
Typical Hookup for Infinitely Variable Electrohydraulic Pressure & Volume Control. Fig. IV
OUTLET PRESSURE (PSI)
3000 2500 2000 1500 1000 500 0 0 200 400 600 800
100 80 60 40 20 0 0 1 2 3 4 5 6 7 8
Volume Command Voltage Nominal output flow vs. input command voltage when used in conjunction with AP*11 amplifier and 786645 proportional pressure controller. Fig. I
Pressure Command Voltage Nominal output pressure vs. input command voltage when used in conjunction with AP*11 amplifier and 786645 proportional pressure controller. Fig. II
Input Current (MA) Nominal input current vs. pressure when used in conjunction with a current source and 786645 proportional pressure controller. Fig. III
Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA
19
Catalog HY28-2662-CD/US
Features
High Strength Cast-Iron Housing Built-In Supercharger High Speed Capability - 3000 RPM Two Piece Housing for Ease of Service Cartridge Type Controls - Field Changeable Replaceable Bronze Clad Port Plate Airbleed Standard for Quick Priming Hydrodynamic Cylinder Barrel Bearing Full Pressure Rating on Water Glycol Fluids Filtered and/or Cooled Drain Line Capable 7 bar (100 PSI) Maximum
Specifications
Pressure Ratings: Outlet Port: 207 bar (3000 PSI) Continuous (P1) 248 bar (3600 PSI) Peak (P3) Inlet Port: 1.7 bar (25 PSI) Maximum 0.17 bar (5 In. Hg.) Minimum @ 1800 RPM (See Inlet Chart for other speeds) 7 bar (100 PSI) Maximum 600 to 3000 RPM*
Controls
Pressure Compensation Remote Pressure Compensation Load Sensing Power (Torque) Limiting Power Limiting and Load Sensing Adjustable Maximum Volume Stop Electrohydraulic Pressure Electrohydraulic Flow and Pressure (Servo Control) Low Pressure Standby
* See Inlet Characteristics Chart on page A155 and consider using Dual Inlet Port configuration on page A178 for applications above 2700 RPM.
Schematic Symbol
(Basic Pump)
Mounting: SAE C 2-Bolt Flange Mount or Diagonally on SAE C 4-Bolt Flange Mount
Installation Data: See page 46 of this catalog for specific recommendations pertaining to system cleanliness, fluids, start-up, inlet conditions, shaft alignment, drain line restrictions and other important factors relative to the proper installation and use of these pumps.
*Approximate Noise Levels dB(A) @ Full Flow 1800 RPM (1200 RPM) 34 bar 69 bar 138 bar 207 bar (500 PSI) (1000 PSI) (2000 PSI) (3000 PSI) 77 (75) 78 (76) 80 (78) 81 (79) Input Power At 1800 RPM, Max. Displacement & 207 bar (3000 PSI) 43.1 kw (57.8 hp)
PAVC65
* Since many variables such as mounting, tank style, plant layout, etc., effect noise levels, it cannot be assumed that the above readings will be equal to those in the field. The above values are for guidance in selecting the proper pump. Noise levels are A-weighted, mean sound pressure levels at 1 meter from the pump, measured and recorded in accordance with applicable ISO and NFPA standards.
20
Catalog HY28-2662-CD/US
Ordering Information
PAVC
Multiple Pumps Pump Axial Piston Variable Controllable Displacement Bearing Option Shaft Outlet Inlet Rotation Differential Control Option Volume Stop Control Options Seals Paint
Code
Code 65
R L
Code Omit 9*
Code Omit
* For applications where side loading may be experienced. Max. side load = 192.8 kg (425 lbs). Typical Applications: Belt/chain drive Universal joint drive Massive couplings Foot mount installations
Code
Omit 2 5
Code
Control Options Standard Pressure Compensated Omit Setting Pressure 28-207 bar (400-3000 PSI) A Pressure & Flow (Load Sensing) *C *H
** M
Code Omit B
Code Outlet
Omit Str. Thd.
Port Location
Top
Type
SAE/Inch
Code Inlet
Omit 2 8 Str. Thd. Flange Flange
Port Location
Rear Top Top
Type
SAE/Inch Threads SAE/Inch Threads ISO 6149/Metric
Remote Pressure Remote Pressure Servo Pressure & Volume S (Requires PPC, Amplifier & Seq. Valve) Servo Pressure & Volume SE (Requires PPC, Amplifier & Seq. Valve) AM Remote Pressure & Flow *CM Remote Pressure, Flow & Power *HM Remote Pressure & Power
**ME
Ordering Notes
Unless otherwise specified, pump is shipped at maximum GPM (1800 RPM) and set to 69 bar (1000 PSI) [See Exceptions]. When factory settings are required, the items shown in Chart #1 must be included with order.
* Power controlled pumps (H, C, HM or CM) must have maximum input power limit specification at a particular drive speed (RPM) and compensator pressure setting (PSI) included with order. Power controlled pumps that do not have input power limit specifications, will be set at a default setting. (15 HP @ 1800 RPM and 1000 PSI) H & C (40 HP @ 1800 RPM and 3000 PSI) HM & CM
Pumps with M, ME, AM, CM or HM controls will be set to compensate at 207 bar (3000 PSI) unless Chart #1 otherwise specifies.
21
Catalog HY28-2662-CD/US
Performance Data
Typical Performance Data - Fluid: Standard Hydraulic Oil 100 SSU @ 49C (120F)
Volumetric Efficiency
Volumetric Efficiency
Efficienc
Flow
Efficiency - %
Efficiency - %
100 90 80 70 60
113.6 (30) 102.2 (27) 90.9 (24) 79.5 (21) 68.1 (18)
100 90 80 70 60
151.4 (40) 136.3 (36) 121.1 (32) 106.0 (28) 90.6 (24)
Overall Efficiency
KW HP 29.8 (40)
Overall
y
KW HP 59.7 (80) 52.2 (70) 44.7 (60) 37.1 (50) 29.8 (40) 22.4 (30) 14.9 (20) 7.5 0 207 (3000) (10) (0)
Flow
26.1 (35) 22.4 (30) 18.6 (25) 14.9 (20) 11.2 (15) 7.5 (10)
Flow
Flow
Input Power
57.8 (15) 45.4 (12) 34.1 22.7 11.4 (9) (6) (3)
75.7 (20) 60.6 (16) 45.4 (12) 30.3 15.1 (8) (4)
r we Po Flow t pu ll In t Fu a
In at put Fu P ll ow Fl er ow
Compen
69 (1000)
sated Po
138 (2000)
wer
Compensated
69 (1000)
Power
138 (2000)
Pressure
Pressure
NOTE: The efficiencies and data in the graph are good only for pumps running at 1800 RPM and stroked to maximum. To calculate approximate input power for the other conditions, use the following formula: HP =
WHERE: Q = Actual Output Flow in GPM PSI = Pressure At Pump Outlet CHp = Input Power @ Full Compensation @ 1800 RPM (from graph read at operating pressure)
Q x (PSI) 1714
+ (CHp)
Actual GPM is directly proportional to drive speed and maximum volume setting. Flow loss, however, is a function of pressure only.
Drain Flow
.14
5.7 (1.5)
3.8 (1.0)
1.9
(.5)
69 (1000)
138 (2000)
207 (3000)
System Pressure
22
Input Power
Catalog HY28-2662-CD/US
Performance Data
Typical Performance Data Minimum Power Settings Attainable With Control Options C, H, CM & HM
PAVC65
KW HP 44.7 (60)
35.8
(48)
207 bar (3000 PSI) Comp. Setting 172 bar (2500 PSI) Comp. Setting 138 bar (2000 PSI) Comp. Setting 103 bar (1500 PSI) Comp. Setting 69 bar (1000 PSI) Comp. Setting
Power
26.8
(36)
170.3
(45)
17.9
(24)
113.6
(30)
8.9
(12)
56.8
(15)
(0)
0 600 1200 1800 2400 3000
NOTE: Minimum attainable HP setting means that input power will not exceed the indicated setting at the indicated RPM and that the pump will achieve full compensator pressure selected. If setting input power limiter below full flow boundary, full flow may not be obtained at low operating pressure.
Determine maximum input power limitation at desired RPM. All points above desired compensator setting curve can be achieved.
Input Power
Input Torque
Flow
37.9
(10)
Flow
18.6 (25)
169.5 (1500)
22.4 (30) 14.9 (20) 7.5 (10) 0 (0) 69 (1000) 138 (2000) 207 (3000)
113.0 (1000)
18.9
(5)
56.5 (500)
0 (0)
Pressure
Pressure
23
Input Torque
56.8
(15)
226.0 (1600)
Input Power
22.4 (30)
Catalog HY28-2662-CD/US
NOTES: 1. Pump shown and dimensioned is a clockwise rotation pump. Outlet port, A and B ports, and controls will be on opposite side for a counterclockwise rotation pump. 2. Pump mounting and shaft comply with SAE C dimensions.
INLET PORT 1-7/8-12UN-2B ST. THREAD O-RING SAE-24 OUTLET PORT 1-5/16-12UN-2B ST. THREAD O-RING SAE-16 81.03 (3.19) 31.75 (1.25)
88.90 (3.50)
38.10 (1.50) SHAFT OPTION OMIT SAE C SHAFT 1-1/4" KEYED MAX. TORQUE = 641 Nm (5,680 IN-LBS)
25.40 (1.00)
ROTATION
RPM
115.82 (4.56)
88.90 (3.50)
31.75 (1.25) PORT B LOW SIGNAL 7/16-20UNF-2B ST. THREAD O-RING SAE-4
PSI MAX
CC/REV
HP
GPM
PSI
VENT/FILL PLUG TORQUE CONTROL ADJUSTMENT SENSITIVITY: 90 Nm (800 IN-LB) PER TURN PRESSURE COMPENSATOR ADJUSTMENT SENSITIVITY: 55 BAR (800 PSI) PER TURN
Rear View
101.60 (4.00) 90.42 (3.56) 81.03 (3.19) 101.60 (4.00) 90.42 (3.56) 81.03 (3.19) CLEARANCE FOR .625 DIA. MOUNTING BOLTS. SAE C 2-BOLT PATTERN
15.75 (.62)
Top View
CLEARANCE FOR .500 DIA. BOLTS MOUNTED DIAGONALLY ON SAE C 4-BOLT PATTERN 12.45 (.49) 7.925 (.312) WIDE KEY 35.33 (1.391) 35.07 (1.381) 127.00 (5.000) 126.94 (4.998) 31.75 (1.250) 31.69 (1.248)
224.03 (8.82)
70.61 (2.78)
50.80 (2.00)
52.32 (2.06)
A 23.37 (.92) PORT A CONTROL DRAIN 9/16-18UNF-2B ST. THREAD O-RING SAE-6 31.75 (1.25) ADJUSTABLE DIFFERENTIAL OPTION 4 SENSITVITY: 13.8 BAR (200 PSI) PER TURN
65.28 (2.57) AIRBLEED DRAIN PORT 7/16-20UNF-2B ST. THREAD O-RING SAE-4
35
115.06 (4.53)
Front View
SHAFT OPTION B 14 TOOTH SAE C SPLINE 12/24 PITCH MAX TORQUE = 641 Nm (5,680 IN-LBS)
Side View
55.63 (2.19)
24
Catalog HY28-2662-CD/US
NOTES: 1. Pump shown and dimensioned is a clockwise rotation pump. Outlet port, A and B ports, and controls will be on opposite side for a counterclockwise pump. 2. Pump mounting and shaft comply with SAE C dimensions.
85.85 (3.38)
25.40 (1.00) SHAFT OPTION OMIT SAE C SHAFT 1-1/4" KEYED MAX. TORQUE = 641 Nm (5,680 IN-LBS) 88.90 (3.50) 31.75 (1.25) SIGNAL PORT PORT B SEE CHART FOR SIZE
69.85 (2.75)
ROTATION VARIABLE VOLUME PUMP RPM HYDRAULIC PUMP/MOTOR DIVISION Otsego, MI 49078 MADE IN USA
PSI MAX
CC/REV
115.82 (4.56)
HP
GPM
PSI
VENT/FILL PLUG 15.74 (.62) TORQUE CONTROL ADJUSTMENT SENSITIVITY: 90 Nm (800 IN-LB) PER TURN PRESSURE COMPENSATOR ADJUSTMENT SENSITIVITY: 55 BAR (800 PSI) PER TURN
Rear View
101.60 (4.00) 90.42 (3.56) 81.02 (3.19) 101.60 (4.00) 90.42 (3.56) 81.02 (3.19)
CLEARANCE FOR .625 DIA. MOUNTING BOLTS. SAE C 2-BOLT PATTERN CLEARANCE FOR .500 DIA. BOLTS MOUNTED DIAGONALLY ON SAE C 4-BOLT PATTERN 7.925 (.312) WIDE KEY
Top View
55.62 (2.19) 12.44 (.49)
70.61 (2.78)
50.80 (2.00)
52.32 (2.06)
31.75 (1.250) 31.69 (1.248) 127.00 (5.000) 126.94 (4.998) 23.36 (.92) CONTROL DRAIN PORT SEE CHART FOR SIZE 65.27 (2.57) 35 ADJUSTABLE DIFFERENTIAL OPTION 4 SENSITIVITY: 13.8 BAR (200 PSI) PER TURN 31.75 (1.25) 63.50 (2.50) 95.25 (3.75) SECONDARY VENT/FILL 219.20 (8.63) A
AIRBLEED DRAIN PORT 7/16-20UNF-2B ST. THREAD O-RING SAE-4 OPTION 8 ISO 6149-4 ADAPTER FITTING ON OPTION 8
115.06 (4.53)
Side View
OPTION 5 VOLUME STOP SENSITIVITY: 4.2 CC/REV/TURN OPTION 2 VOLUME STOP SENSITIVITY: 3.8 CC/REV/TURN
Front View
SHAFT OPTION B 14 TOOTH SAE C SPLINE 12/24 PITCH MAX. TORQUE = 641 Nm (5,680 IN-LBS)
55.63 (2.19)
25
Catalog HY28-2662-CD/US
* = Length in Feet
FEEDBACK CONNECTOR MS3102R14S-2PY MATES WITH MS3106A14S-2SY (PART NO. 800722) ELECTROHYDRAULIC CABLE CAN BE ORDERED AS EHC*4Y* 160.78 (6.33)
GND
+10
L1
L2
NOTES:
1. 2. Consult factory for information relative to pump option selection and additional components required for desired pump function. For electrohydraulic flow and pressure control of one or two pumps, make electrical connections per Figure IV. When one pump is used, omit connections to pump #2 feedback. For electrohydraulic flow only, eliminate pressure command signal and place jumper between Press CMD and +10V terminals (compensating pressure will be controlled by maximum setting on pump or remote compensator if used). For electrohydraulic pressure only, eliminate volume command signal, and place jumper between VOL CMD and +10V terminals or use 801179 pressure driver card. Figures I thru III show nominal input vs. output relationships. The actual values will vary with component tolerances. Full volume range will be realized with 0 to 7 volts. Full pressure range will be realized with 0 to 7 volts, or 0-500MA. Pump shown is a clockwise rotation. For a counterclockwise rotation LVDT feedback is on opposite side. For further detail on installation of AP11/AP211, refer to the latest edition of Catalog 2600-400-x/US.
OUT
D C B A D C B A
3.
4.
5.
D C B A Volume Command PPC Valve Signal 693705 Pipe 694586 St. Thd. 786645-3000 PSI
D C B A
Pump #2 Feedback (if used)
6. 7.
Typical Hookup for Infinitely Variable Electrohydraulic Pressure & Volume Control. Fig. IV
OUTLET PRESSURE (PSI)
3000 2500 2000 1500 1000 500 0 0 200 400 600 800
100 80 60 40 20 0 0 1 2 3 4 5 6 7 8
Volume Command Voltage Nominal output flow vs. input command voltage when used in conjunction with AP*11 amplifier and 786645 proportional pressure controller. Fig. I
Pressure Command Voltage Nominal output pressure vs. input command voltage when used in conjunction with AP*11 amplifier and 786645 proportional pressure controller. Fig. II
Input Current (MA) Nominal input current vs. pressure when used in conjunction with a current source and 786645 proportional pressure controller. Fig. III
Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA
26
Catalog HY28-2662-CD/US
27
Catalog HY28-2662-CD/US
Technical Information
Performance Information
Series PAVC100 Pressure Compensated,Variable Volume, Piston Pump
Features
High Strength Cast-Iron Housing Built-In Supercharger High Speed Capability - 2600 RPM Cartridge Type Controls - Field Changeable Replaceable Bronze Clad Port Plate Airbleed Standard for Quick Priming Hydrodynamic Cylinder Barrel Bearing Full Pressure Rating on Water Glycol Fluids Filtered and/or Cooled Drain Line Capable 7 bar (100 PSI) Maximum Thru-Shaft Capable
Specifications
Pressure Ratings: Outlet Port: 207 bar (3000 PSI) Continuous (P1) 248 bar (3600 PSI) Peak (P3) Inlet Port: 1.7 bar (25 PSI) Maximum 0.17 bar (5 In. Hg.) Minimum @ 1800 RPM (See Inlet Chart for other speeds) 7 bar (100 PSI) Maximum
Controls
Pressure Compensation Remote Pressure Compensation Load Sensing Power (Torque) Limiting Power Limiting and Load Sensing Adjustable Maximum Volume Stop Electrohydraulic Pressure Electrohydraulic Flow and Pressure (Servo Control) Low Pressure Standby
Control Drain:
Speed Ratings: 600 to 2600 RPM Operating Temperature Range: Housing Material: Cast-Iron Filtration: Maintain SAE Class 4, ISO 16/13, ISO 18/15 Maximum Recommended Mounting: SAE C 2-Bolt Flange Mount or Diagonally on SAE C 4-Bolt Flange Mount 40C to 71C ( 40F to 160F)
Schematic Symbol
(Basic Pump)
Installation Data: See page 46 of this catalog for specific recommendations pertaining to system cleanliness, fluids, start-up, inlet conditions, shaft alignment, drain line restrictions and other important factors relative to the proper installation and use of these pumps.
* Since many variables such as mounting, tank style, plant layout, etc., effect noise levels, it cannot be assumed that the above readings will be equal to those in the field. The above values are for guidance in selecting the proper pump. Noise levels are A-weighted, mean sound pressure levels at 1 meter from the pump, measured and recorded in accordance with applicable ISO and NFPA standards.
28
Catalog HY28-2662-CD/US
Ordering Information
PAVC
Multiple Pumps Pump Axial Piston Variable Controllable
100
Displacement Bearing Option Shaft Outlet Inlet Rotation Volume Thru- Variations Differential Stop Shaft Control Control Option Threads Options Option Seals Paint Multiple Pumps
Code Omit
Code Omit P
Code
Code
Code 100 CM3/REV (In3/Rev.) 100 (6.1) R L
Rotation*
Right (CW) Left (CCW)
Omit
*Viewed from shaft end. Code Omit Multiple Pumps Single Pump Pump Factory Mounted on Rear
Code
Omit 9*
Bearing Option
Single Piece Shaft Dual Bearing
Code
Omit 2 5*
Code
Control Options
* For applications where side loading may be experienced. Max. side load = 113.4 kg (250 lbs). Typical Applications: Belt/chain drive Universal joint drive Massive couplings Foot mount installations
Code
Omit B C D
Shaft Option
1-1/4" Keyed (SAE C) 14T Spline (SAE C) 1-1/2" Keyed (SAE CC) 17T Spline (SAE CC)
Code
Omit 6 9*
Thru-Shaft Threads
No Thru-Shaft UNC Metric
Use SAE C-C shaft on Thru-Shaft pump variation when combined input torque of front and rear pumps exceed 565 Nm (5000 In-Lbs).
Differential Options
Non-Adjustable Differential Adjustable Differential
Port Location
Top Top
Omit 4
Standard Pressure Compensated Omit Setting Pressure 41-207 bar (600-3000 PSI) A Pressure & Flow (Load Sensing) *C Pressure, Flow & Power *H Pressure Comp. & Power **M Remote Pressure **ME Remote Pressure Servo Pressure & Volume S (Requires PPC, Amplifier & Seq. Valve) Servo Pressure & Volume SE (Requires PPC, Amplifier & Seq. Valve) AM Remote Pressure & Flow *CM Remote Pressure, Flow & Power *HM Remote Pressure & Power * Power controlled pumps (H, C, HM or CM) must have maximum input power limit specification at a particular drive speed (RPM) and compensator pressure setting (PSI) included with order. Power controlled pumps that do not have input power limit specifications, will be set at default setting. (22.5 HP @ 1800 RPM and 1000 PSI) H & C (60 HP @ 1800 RPM and 3000 PSI) HM & CM
Type
SAE/Inch SAE/Inch
Pumps with M, ME, S, SE, AM, CM or HM controls will be set to compensate at 207 bar (3000 PSI) unless Chart #1 otherwise specifies.
Thru-Shaft Variations
No Thru-Shaft Option Thru-Shaft, SAE AA Pilot, 1/2" Keyed Shaft Thru-Shaft, SAE AA Pilot, 9 Tooth 20/40 Pitch Spline Shaft Thru-Shaft, SAE A Pilot, 9 Tooth 16/32 Pitch Spline Shaft Thru-Shaft, SAE B Pilot, 7/8" Keyed Shaft Thru-Shaft, SAE B Pilot, 1 Keyed Shaft Thru-Shaft, SAE B Pilot, 13 Tooth 16/32 Pitch Spline Shaft Thru-Shaft, SAE B Pilot, 15 Tooth 16/32 Pitch Spline Shaft Thru-Shaft, SAE C Pilot, 1-1/4" Keyed Shaft Thru-Shaft, SAE C Pilot, 14 Tooth 12/24 Pitch Spline Shaft
2 8
Ordering Notes
Unless otherwise specified, pump is shipped at maximum GPM (1800 RPM) and set to 69 bar (1000 PSI) [See Exceptions]. When factory settings are required, the items shown in Chart #1 must be included with order.
Inlet port option 2 or 8 (top/bottom) must be used with all Thru-Shaft pumps. * Use SAE C-C shaft on thru-shaft pump variation when combined input torque of front and rear pumps exceed 565 Nm (5000 In-Lbs).
29
Catalog HY28-2662-CD/US
Performance Data
Typical Performance Data - Fluid: Standard Hydraulic Oil 100 SSU @ 49C (120F)
PAVC100 @ 1200 RPM
LPM GPM
Volumetric Efficiency
cy
Volumetric Efficiency
Flow
Efficiency - %
100 90 80 70 60
Overall
Efficien
Flow
113.6 (30)
Ov
era
ll
ic Eff
ien
cy
Power
In at put Fu Po ll w Fl er ow
Flow
Flow
94.6 (25) 75.7 (20) 56.8 (15) 37.9 (10) 18.9 (5)
94.6 (25) 75.7 (20) 56.8 (15) 37.9 (10) 18.9 (5)
er ow low P ut ll F np Fu I t a
Compen
69 (1000)
sated Po
138 (2000)
wer
(10) (0)
Compen
69 (1000)
sate
d Power
(10) (0)
138 (2000)
Pressure
Pressure
NOTE: The efficiencies and data in the graph are good only for pumps running at 1800 RPM and stroked to maximum. To calculate approximate input power for the other conditions, use the following formula: HP =
WHERE: Q = Actual Output Flow in GPM PSI = Pressure At Pump Outlet CHp = Input Power @ Full Compensation @ 1800 RPM (from graph read at operating pressure)
Q x (PSI) 1714
+ (CHp)
Actual GPM is directly proportional to drive speed and maximum volume setting. Flow loss, however, is a function of pressure only.
Drain Flow
.14
11.3
(3)
7.6
(2)
3.8
(1)
69 (1000)
138 (2000)
207 (3000)
System Pressure
Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA
30
Power
Catalog HY28-2662-CD/US
Performance Data
Typical Performance Data Minimum Power Settings Attainable With Control Options C, H, CM & HM
PAVC100
KW (HP) 55.9 (75)
44.7
(60)
172 bar (2500 PSI) Comp. Setting 138 bar (2000 PSI) Comp. Setting Full Flow Boundary 103 bar (1500 PSI) Comp. Setting 69 bar (1000 PSI) Comp. Setting 34 bar (500 PSI) Comp. Setting
Power
33.6
(45)
22.4
(30)
11.2
(15)
NOTE: Minimum attainable HP setting means that input power will not exceed the indicated setting at the indicated RPM and that the pump will achieve full compensator pressure selected. If setting input power limiter below full flow boundary, full flow may not be obtained at low operating pressure. Determine maximum input power limitation at desired RPM. All points above desired compensator setting curve can be achieved.
0
0 600 1200 1800 2400 3000
Input Power
Input Torque
Flow
Flow
44.7 (60) 37.3 (50) 29.8 (40) 22.4 (30) 14.9 (20) 7.5 0 69 (1000) 138 (2000) 207 (3000) (10) (0)
Pressure
Pressure
31
Input Torque
282.5 (2500)
Input Power
52.2 (70)
Catalog HY28-2662-CD/US
NOTE: Pump shown and dimensioned is a clockwise rotation pump. For a counterclockwise rotation pump the outlet port, control drain, signal port and pump controls will be on other side.
Port Location Outlet Option Omit Inlet Option Omit Outlet Port SAE-20 Straight Thread (1-5/8-12UNC) 1-1/4" SAE Flange 7/16-14UNC Thread Standard Pressure Series (Code 61) Inlet Port 2" SAE 4-Bolt Flange 1/2-13UNC Threads Standard Pressure Series (Code 61) 2" SAE 4-Bolt Flange 1/2-13UNC Threads Standard Pressure Series (Code 61) Control Drain SAE-6 Straight Thread (9/16-18UNF) SAE-6 Straight Thread (9/16-18UNF) Signal Port SAE-4 Straight Thread (7/16-20UNF) SAE-4 Straight Thread (7/16-20UNF)
Omit
55.62 (2.19) SHAFT OPTION B SAE C SPLINE 14 TOOTH 12/24 DP MAX. TORQUE = 639 Nm (5,680 IN-LBS)
61.97 (2.44) SHAFT OPTION C SAE C-C SHAFT MAX. TORQUE = 1,218 Nm (10,780 IN-LBS) SHAFT OPTION D SAE C-C SPLINE 17 TOOTH 12/24 DP MAX. TORQUE = 1,218 Nm (10,780 IN-LBS)
107.95 (4.25)
28.70 (1.13)
31.75 (1.25)
SHAFT OPTION OMIT SAE C SHAFT MAX. TORQUE = 639 Nm (5,680 IN-LBS)
REAR INLET PORT (INLET PORT OPTION OMIT) SEE CHART FOR PORT SIZE
TORQUE CONTROL ADJUSTMENT (CONTROL OPTIONS C,H,CM & HM) SENSITIVITY: 130 Nm (1,150 IN-LBS) PER REV.
Rear View
Top View
32
141.47 (5.57)
Rotation
PSI max
cc/Rev
RPM
HP
GPM
PSI
Catalog HY28-2662-CD/US
NOTE: Pump shown and dimensioned is a clockwise rotation pump. For a counterclockwise rotation pump the outlet port, control drain, signal port and pump controls will be on other side.
41.40 (1.63)
OPTION 3 OUTLET PORT (SEE CHART ON PAGE A166 FOR PORT SIZE)
58.67 (2.31)
30.22 (1.19)
90.42 (3.56) 81.02 (3.19) PORT B SIGNAL STRAIGHT THREAD O-RING SEE CHART ON A166 FOR PORT SIZE 7.925 (.312) WIDE KEY 35.33 (1.391) 35.07 (1.381) 127.00 (5.000) 126.94 (4.998) 31.75 (1.250) 31.69 (1.248) 55.62 (2.19) 12.44 (.49) 158.49 (6.24) 303.53 (11.95) ROTATION ARROW
7.11 (.28)
91.94 (3.62)
74.67 (2.94)
112.77 (4.44) AIRBLEED DRAIN PORT 7/16-20UNF-2B ST. THREAD O-RING SAE-4 36.32 (1.43) PORT A CONTROL STRAIGHT THREAD O-RING SEE CHART ON A166 FOR PORT SIZE OPTION 2 41.40 MAX. VOLUME (1.63) ADJUSTMENT SENSITIVITY: 5CC/REV/REV 2.54 (.10) MAX 55.88 (2.20) MAX
Front View
33
Side View
Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA
Catalog HY28-2662-CD/US
NOTES: 1. Pump shown and dimensioned is a clockwise rotation top/ bottom inlet option pump. For a counterclockwise rotation pump the outlet port, control drain, signal port, and pump controls will be on other side. 2. For other available shafts see page A34.
VENT-FILL/INLET GAUGE PORT 7/16-20UNF-2B STRAIGHT THREAD O-RING THREADED OURTLET PORT OUTLET PORT OPTION OMIT SEE CHART A169 FOR PORT SIZE 28.70 (1.13) 42.92 (1.69)
Rotation VARIABLE VOLUME PUMP
107.95 (4.25)
107.95 (4.25)
139.70 (5.50)
41.40 (1.63)
OPTION 2 INLET PORT FLANGE INLET PORT SEE CHART A169 FOR PORT SIZE BOTTOM PORT OPPOSITE SIDE SAME PATTERN ROTATED 90
31.75 (1.25)
PSI max
cc/Rev
101.60 (4.00)
SHAFT OPTION OMIT SAE C SHAFT MAX. TORQUE = 639 Nm (5,680 IN-LBS)
RPM
50.80 (2.00)
PRESSURE COMPENSATOR ADJUSTMENT SENSITIVITY: 55 BAR (800 PSI) PER REV ADAPTABLE TO SAE C 2-BOLT MOUNTING OR DIAGONALLY ON SAE C 4-BOLT MOUNTING OUTLET PRESSURE GAUGE PORT 7/16-20UNF-2B ST. THREAD O-RING R7.11 (.28) 91.94 (3.62)
GPM
HP
PSI
77.72 (3.06) TORQUE CONTROL ADJUSTMENT (CONTROL OPTIONS C,H,CM & HM) SENSITIVITY: 130 Nm (1,150 IN-LB) PER REV.
Rear View
90.42 (3.56) 81.02 (3.19) 90.42 (3.56) 81.02 (3.19) SIGNAL PORTS PORT B SEE CHART, A169 FOR PORT SIZE 55.62 (2.19)
Top View
159.49 (6.24)
74.67 (2.94)
31.75 (1.250) 31.69 (1.248) 127.00 (5.000) 126.94 (4.998) 36.32 (1.43) CONTROL DRAIN PORT A SEE CHART, A169 FOR PORT SIZE 41.40 (1.63) OPTION 4 DIFFERENTIAL PRESSURE ADJUSTMENT 28 BAR (400 PSI) PER REV 73.15 (2.88) 104.90 (4.13) BOTTOM INLET PORT 49.53 (1.95) MAX. OPTION 5 MAX. VOLUME ADJUSTMENT 5.6CC/REV/REV
112.77 (4.44) AIRBLEED DRAIN PORT 7/16-20UNF-2B ST. THREAD O-RING SAE-4 OPTION 8 ISO 6149-4 ADAPTER FITTING ON OPTION 8 114.30 (4.50) MAX
Front View
Side View
34
Catalog HY28-2662-CD/US
NOTE: Pump shown and dimensioned is a clockwise rotation pump. For a counterclockwise rotation pump the outlet port, control drain, signal port and pump controls will be on other side.
Port Location Outlet Option Inlet Option 2 Omit 8 ISO6149-20 Straight Thread (M42 x 2) 1-1/4" SAE Flange 7/16-14UNC Thread Standard Pressure Series (Code 61) 1-1/4" SAE Flange M10 x 1.5 Thread Standard Pressure Series (Code 61) Outlet Port SAE-20 Straight Thread (1-5/8-12UN) Inlet Port 2" SAE 4-Bolt Flange 1/2-13UNC Threads Standard Pressure Series (Code 61) 2" SAE 4-Bolt Flange M12 x 1.75 Threads Standard Pressure Series (Code 61) 2" SAE 4-Bolt Flange 1/2-13UNC Threads Standard Pressure Series (Code 61) 2" SAE 4-Bolt Flange M12 x 1.75 Threads Standard Pressure Series (Code 61) Control Drain SAE-6 Straight Thread (9/16-18UNF) ISO6149-5 Straight Thread (M14 x 1.5) SAE-6 Straight Thread (9/16-18UNF) ISO6149-5 Straight Thread (M14 x 1.5) Signal Port SAE-4 Straight Thread (7/16-20UNF) ISO6149-4 Straight Thread (M12 x 1.5) SAE-4 Straight Thread (7/16-20UNF) ISO6149-4 Straight Thread (M12 x 1.5)
2 3 8
Variation
6A1 6A3 6A4 6B1 6B2 6B3 6B4 6C2 6C3 9A1 9A3 9A4 9B1 9B2 9B3 9B4 9C2 9C3
A 12.70 (.500) 12.70 (.500) 53.98 (2.125) 53.98 (2.125) 53.98 (2.125) 53.98 (2.125) 53.98 (2.125) 53.98 (2.125) 12.70 (.500) 12.70 (.500) 53.98 (2.125) 53.98 (2.125) 53.98 (2.125) 53.98 (2.125) 53.98 (2.125) 53.98 (2.125)
B 50.83/50.85 (2.001/2.002) 50.83/50.85 (2.001/2.002) 82.58/82.60 (3.251/3.252) 101.63/101.65 (4.001/4.002) 101.63/101.65 (4.001/4.002) 101.63/101.65 (4.001/4.002) 101.63/101.65 (4.001/4.002) 127.03/127.05 (5.001/5.002) 127.03/127.05 (5.001/5.002) 50.83/50.85 (2.001/2.002) 50.83/50.85 (2.001/2.002) 82.58/82.60 (3.251/3.252) 101.63/101.65 (4.001/4.002) 101.63/101.65 (4.001/4.002) 101.63/101.65 (4.001/4.002) 101.63/101.65 (4.001/4.002) 127.03/127.05 (5.001/5.002) 127.03/127.05 (5.001/5.002)
C 82.55 (3.250) 82.55 (3.250) 106.38 (4.188) 146.05 (5.750) 146.05 (5.750) 146.05 (5.750) 146.05 (5.750) 180.98 (7.125) 180.98 (7.125) 82.55 (3.250) 82.55 (3.250) 106.38 (4.188) 146.05 (5.750) 146.05 (5.750) 146.05 (5.750) 146.05 (5.750) 180.98 (7.125) 180.98 (7.125)
D N/A N/A N/A 89.81 (3.536) 89.81 (3.536) 89.81 (3.536) 89.81 (3.536) 114.50 (4.508) 114.50 (4.508) N/A N/A N/A 89.81 (3.536) 89.81 (3.536) 89.81 (3.536) 89.81 (3.536) 114.50 (4.508) 114.50 (4.508)
E 5/16-18UNC-2B 5/16-18UNC-2B 3/8-16UNC-2B 1/2-13UNC-2B 1/2-13UNC-2B 1/2-13UNC-2B 1/2-13UNC-2B 5/8-11UNC-2B 5/8-11UNC-2B M8 x 1.25 M8 x 1.25 M10 x 1.50 M12 x 1.75 M12 x 1.75 M12 x 1.75 M12 x 1.75 M16 x 2 M16 x 2
F N/A N/A N/A 1/2-13UNC-2B 1/2-13UNC-2B 1/2-13UNC-2B 1/2-13UNC-2B 1/2-13UNC-2B 1/2-13UNC-2B N/A N/A N/A M12 x 1.75 M12 x 1.75 M12 x 1.75 M12 x 1.75 M12 x 1.75 M12 x 1.75
G 12.70 x 3.175 Key (.500 x .125) 9 Tooth 20/40 Pitch 9 Tooth 16/32 Pitch 22.23 x 6.35 Key (.875 x .250) 25.4 x 6.35 Key (1.000 x .250) 13 Tooth 16/32 Pitch 15 Tooth 16/32 Pitch 31.75 x 7.92 Key (1.250 x .312) 14 Tooth 12/24 Pitch 12.70 x 3.175 Key (.500 x .125) 9 Tooth 20/40 Pitch 9 Tooth 16/32 Pitch 22.23 x 6.35 Key (.875 x .250) 25.4 x 6.35 Key (1.000 x .250) 13 Tooth 16/32 Pitch 15 Tooth 16/32 Pitch 31.75 x 7.92 Key (1.250 x .312) 14 Tooth 12/24 Pitch
H N/A N/A N/A 2 2 N/A N/A 82.55 (3.250) N/A N/A N/A N/A 2 2 N/A N/A 82.55 (3.250) N/A
2. 88.90 (3.500) for pumps with shaft lengths between 53.34 (2.10) and 58.67 (2.31) inches. 76.20 (3.000) for pumps with shaft lengths between 40.64 (1.60) and 45.72 (1.80) inches.
35
Catalog HY28-2662-CD/US
NOTES: 1. Rear adapters may be rotated 90. 2. Pump shown is a clockwise rotation pump. For a counterclockwise pump the outlet port, control drain and control adjustments will be on opposite side. 3. Maximum torque transmitting capacity for rear mounting of pumps is 639 Nm (5,680 In. Lbs). Lower allowables may apply based on pump mounted on rear.
299.72 (11.80)
A C C 2 E
Side View
H C C 2 B
D 2
D G E
D 2
Rear View
36
Catalog HY28-2662-CD/US
NOTE: Reference Electrohydraulic Accessories Catalog 2600-400-1 for more complete information.
* = Length in Feet
FEEDBACK CONNECTOR MS3102R14S-2PY MATES WITH MS3106A14S-2SY (PART NO. 800722) ELECTROHYDRAULIC CABLE CAN BE ORDERED AS EHC*4Y*
AP*11 Amplifier for use with one or two pumps
PRESS CMD
VOL CMD
152.40 (6.00)
OUT GND +10 L1 L2
D C B A D C B A
NOTES:
1. Consult factory for information relative to pump option selection and additional components required for desired pump function. 2. For electrohydraulic flow and pressure control of one or two pumps, make electrical connections per Figure IV. When one pump is used, omit connections to pump #2 feedback. 3. For electrohydraulic flow only, eliminate pressure command signal and place jumper between Press CMD and +10V terminals (compensating pressure will be controlled by maximum setting on pump or remote compensator if used). 4. For electrohydraulic pressure only, eliminate volume command signal and place jumper between VOL CMD and +10V terminals or use 801179 pressure driver card. 5. Figures I thru III show nominal input vs. output relationships. The actual values will vary with component tolerances. Full volume range will be realized with 0 to 7 volts. Full pressure range will be realized with 0 to 7 volts, or 0-500MA. 6. Pump shown is a clockwise rotation. For a counterclockwise rotation LVDT feedback is on opposite side. 7. For further detail on installation of AP11/AP211, refer to the latest edition of Catalog 2600-400-x/US.
Supply Voltage (115V/60Hz)
D C B A Volume Command PPC Valve Signal 693705 Pipe 694586 St. Thd. 786645-3000 PSI
D C B A
Pump #2 Feedback (if used)
Typical hookup for infinitely variable electrohydraulic pressure & volume control. Fig. IV
100 80 60 40 20 0 0 1 2 3 4 5 6 7 8
3000 2500 2000 1500 1000 500 0 0 200 400 600 800
Volume Command Voltage Nominal output flow vs. input command voltage when used in conjunction with AP*11 amplifier and 786645 proportional pressure controller. Fig. I
Pressure Command Voltage Nominal output pressure vs. input command voltage when used in conjunction with AP*11 amplifier and 786645 proportional pressure controller. Fig. II
Input Current (MA) Nominal input current vs. pressure when used in conjunction with a current source and 786645 proportional pressure controller. Fig. III
Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA
37
Catalog HY28-2662-CD/US
1
95 Nm (70 FT. LBS.) TORQUE MAX VOL. STOP VARIATION - 2
4 RETAINER DETAIL
THRUST WASHER
(Not on PAVC100)
1 1 2
1 2
BACK-UP RING
BACK-UP RING
SLEEVE O-RING
1 1 2
O-RING
1 2
BACK-UP RING
BACK-UP RING
38
Catalog HY28-2662-CD/US
Installation Information
THESE ITEMS ARE SHOWN IN POSITION FOR CONTROL OPTION OMIT. SEE SEPARATE DIAGRAM FOR OTHER CONTROL OPTIONS. 13.5 Nm (10 FT. LBS.) TORQUE 169 Nm (125 FT. LBS.) TORQUE
5 76
7
108 Nm (80 FT. LBS.) TORQUE
5 9
68 Nm (50 FT. LBS.) TORQUE
3 8
27 Nm (20 FT. LBS.) TORQUE NON-ADJUSTABLE DIFFERENTIAL VARIATION - OMIT
10
11 11 10 10
Position 1 Open 102 x 1 102 x 1 Open 690870 102 x 1 690870 102 x 1 102 x 1 102 x 1 690870 2 690870 690870 690870 690870 Open 690870 Open 690870 690870 690870 Open 3 108 x 4 Open Open 108 x 4 Open Open Open Open 786635 786635 Open 4 108 x 4 108 x 4 108 x 4 108 x 4 108 x 4 108 x 4 108 x 4 108 x 4 Open Open 108 x 4 5
10 TORQUE (HP) CONTROL (See next page) 11 VOLUME SERVO FEEDBACK (See next page) Part Number Description
102 x 1 108 x 4 690870 800599 786635 787474 Solid Pipe Plug (1/16") SAE Plug - 4 .028 Orifice Plug (1/16") .034 Orifice Plug (1/16") .034 Orifice Fitting Upstroke Spring
787474 787474 787474 787474 787474 787474 787474 787474 787474 787474 787474
10
11 11 10 10
39
Catalog HY28-2662-CD/US
Installation Information
10 CONTROL OPTION C & H
PRESSURE, POWER & FLOW
27 Nm (20 FT.-LBS.) TORQUE 14 Nm (10 FT.-LBS.) TORQUE 10-32UNF-2B OMIT SET @ MAX. PRESSURE PER TEST SPEC. THEN INSTALL JAM NUT, LOCKING NUT AND LOCKING TAB. ADD
OMIT
NOTE: Install ball through torque port, seat in place through bolt hole.
BALL LVDT ASSEMBLY PUMP HOUSING CONTROL BUTTON SERVO PISTON SERVO VOLUME HOUSING LOCKING NUT
40
Catalog HY28-2662-CD/US
Installation Information
41
Catalog HY28-2662-CD/US
Technical Information
B
101.60 (4.000) 101.54 (3.998) SAE B PILOT 101.60 (4.000) 101.54 (3.998) SAE B PILOT
55.62 (2.19) SAE C SPLINED SHAFT 14 TOOTH 12/24 PITCH 9.39 (.370) SAE B SPLINED SHAFT 13 TOOTH 16/32 PITCH
B
101.60 (4.000) 101.54 (3.998) SAE B PILOT 127.00 (5.000) 126.94 (4.998) SAE C PILOT
SAE C PILOT SAE D SPLINE SHAFT (SINGLE PIECE SHAFT) OR (DUAL BEARING SHAFT)
42
Catalog HY28-2662-CD/US
Technical Information
Harsh Environment Seal Option
BEARING GLAND BEARING
PAVC65 DETAIL
PAVC100 DETAIL
SHAFT SEAL W/ WIPER SNAP RING SNAP RING (SPIRAL) O-RING SPECIAL TWO PIECE SHAFT DUAL BEARING DESIGN
SHAFT SEAL W/ WIPER SNAP RING SNAP RING (SPIRAL) O-RING SPECIAL TWO PIECE SHAFT DUAL BEARING DESIGN
B
101.60 (4.000) 101.54 (3.998) SAE B PILOT
31.75 (1.250) 31.69 (1.248) 127.00 (5.000) 126.94 (4.998) SAE C PILOT
B
127.00 (5.000) 126.94 (4.998) SAE C PILOT
B
31.75 (1.250) 31.69 (1.248) 127.00 (5.000) 126.94 (4.998) SAE C PILOT 127.00 (5.000) 126.94 (4.998) SAE C PILOT
43
Catalog HY28-2662-CD/US
Technical Information
Sculptured Housings - PAVC65
NOTE: There are many sculptured housings and special porting configurations for applications where the standard PAVC has interference. Consult factory.
52.0 (2.05) GAGE PORT 7/16-20 UN-2B ST.THREAD O-RING SAE-4 26.92 (1.06) 74.93 R (2.95) 64.26 (2.53)
87.37 (3.44)
27.17 (1.07)
64.26 (2.53)
27.17 (1.07)
NOTE: Dual inlet recommended in applications where pump operating speed exceeds 2700 RPM without inlet precharge pressure.
35.10 (1.50)
69.85 (2.75)
INLET PORT 1-1/2" SAE 4-BOLT FLANGE 35.81 (1.41) 85.85 (3.38)
44
Catalog HY28-2662-CD/US
Technical Information
Transmission Spacer
SAE B Pilot
38.10 (1.50) 13.46 (.53) NOTE:
73.02 (2.875)
73.02 (2.875)
9.39 (.370)
O-RING
Speed Pickup
PAVC 33, 38, 65
NOTE: PAVC65 Shown
NOTE:
The speed pick-up option is a provision for a speed sensor to read off the flutes on the barrel. Consult factory.
SENSOR ADAPTER (303 STAINLESS STEEL) PRESS FIT INTO HOUSING BARREL FLUTES (7 ON PAVC65) (5 ON PAVC33/38) PISTONS (7 ON PAVC65) (5 ON PAVC33/38)
PUMP HOUSING
Pump Enable
PAVC65
NOTE:
The pump enable option allows the pump to go lower than catalog low-press. standby setting. consult factory
PAVC33/38
EXTERNAL CONTROL ONLY
CUST. SUPPLIED
A
134.36 (5.29)
PAVC100
EXTERNAL CONTROL ONLY
23.36 (.92)
A
35 43.18 (1.70) APPROX. PORT A CONTROL DRAIN 9/16-18 UNF-2B ST.THRD O-RING 31.49 (1.24) CUST. SUPPLIED ENABLE PORT 7/16-20 UNF-2B ST.THRD O-RING
45
Catalog HY28-2662-CD/US
Installation Information
Use Of A Relief Valve
The use of a relief valve, while not mandatory is recommended in the main circuit to suppress hydraulic shock loads and additional system protection. If a minimum volume stop is used, the use of a relief valve is mandatory.
Fluid Recommendations
Premium quality hydraulic oil with a viscosity range between 150-250 SSU (30-50 cst.) at 38C (100F). Normal operating viscosity range between 80-1000 SSU (17-180 cst.). Maximum start-up viscosity is 4000 SSU (1000 cst.). NOTE: Consult Parker when exceeding 71C (160F) operation. Oil should have maximum anti-wear properties, rust and oxidation treatment.
Filtration
For maximum pump and system component life, the system should be protected from contamination at a level not to exceed 125 particles greater than 10 microns per milliliter of fluid. (SAE Class 4/ISO 16/13). Due to the nature of variable displacement pumps, variations in pump inlet conditions, fluid acceleration losses, system aeration, and duty cycle we do not recommend suction line filters. We do recommend the use of a properly sized, in-tank suction strainer. Contact your Parker representative for assistance.
Start-Up
On initial start-up, the case should be filled with oil, pressure should be reduced and the circuit should be open or the air bled from the pump outlet to permit priming. Use of the airbleed is recommended on initial start-up. See Installation and Mounting Section to connect airbleed.
Special Installations
Consult your Parker representative for any application requiring the following: Pressure above rated, drive speed above maximum, indirect drive, fluid other than petroleum oil, oil temperature above 71C (160F).
Inlet Conditions
Not to exceed .17 bar (5 In. Hg.). Vacuum at 1800 RPM on petroleum base fluids. See recommended speed spectrum for specific inlet conditions.
Inlet Pressure
Not to exceed 1.72 bar (25 PSI).
46