You are on page 1of 2

Pressure Transmitters

With piezoresistive measuring cell Pressure ranges 0-100 mbar to 0-1000 bar
Application Pressure transmitters model PTM are suitable for overpressure- andabsolutepressuremeasurementofliquidandgaseousmedia of0-100mbar up to 0-1000 bar, that do not corrode 1.4571 and 1.4435 (316 stainless steel), as well as Viton. Twobasicmodelareavailable: Overpressure 0-100 mbar to 0-1000 bar (up to 0-16 bar withventilationtoatmosphere)

PTM

Absolute pressure (a) 0-100 mbar to 0-1000 bar (referencepointzeroabsolute) Thepressuretransmittersaretemperature-compensatedandprovide acalibratedoutputsignal. Construction Der piezoresistive sensor is installed in the pressure connection piece and is surrounded by silicone oil. It is separated from the mediumbyathinstainlesssteeldiaphragm. The earth conductor of the plug connector is connected to the case.Theattachmentofchemicalseals,e.g.forthefoodindustry ispossible,seedatasheetsofcatalogue-heading7.... Standard Version Construction Type Installationlength:standard Process Connection GB("BSP),1.4571(316stainlesssteel) Measuring Cell / Sensor Piezoresistivemeasuringcell:1.4435(316stainlesssteel) Diaphragm(placedinside):1.4435(316stainlesssteel) Sensor Sealing FPM (Viton) Case 1.4301 (304 stainless steel), case protection type IP 65 Pressure Ranges / Overload Overpressure-andabsolutepressure 0-100 mbar 0- 4 bar 0- 40 bar 0-160 mbar 0- 6 bar 0- 60 bar 0-250 mbar 0-10 bar 0- 100 bar The correspon0-400 mbar 0-16 bar 0- 160 bar ding vacuum- / 0-600 mbar 0-25 bar 0- 250 bar compound 0-1 bar 0- 400 bar gaugesare 0-1.6 bar 0- 600 bar alsoavailable. 0-2.5 bar 0-1000 bar Overload pressurerange-dependent,typicallyatleast 2-fold,exactindicationuponrequest Output Signal 4 ... 20 mA 2-wire 0 ... 20 mA 3-wire 0 ... 10 V 3-wire Power supply 10...40 VDC 8...28 VDC 13...28 VDC Load impedance (UB -10V)/0.02 A (UB - 8V)/0.02 A min. 10 kOhm Temperature Influence in the Rated Temperature Range Zero point: < 0.3 % / 10 K Measuringspan: <0.2%/10K Reference Temperature 20C(68C) Long-term Stability of Zero Point and Span Betterthan0.25%p.a. Reverse Voltage Protection Available Electrical Connection Plugconnection3-pin+protectivecontact(DINEN175301-803) Forassuringtheelectromagneticcompatibility(EMC)pleaseuse ashieldedcable(e.g.LP/LiMYCY).Theshieldhastobeconnected tothecaseresp.tothegroundterminaloftheterminalbox. Position of Installation Any EMC EN 61 000-6-3, 61 000-6-2 Options Processconnection:-GB,"NPT,"NPT(EN837-3), M 12x1.5, M 20x1.5 -Highpressure-connection(female-or male thread) - VCR union nut, VCR malethreadrigid, othersupnrequest Electricalconnection: -Cablebushing(IP67)with2mcable -CircularplugconnectorM12x1(IP67) -Angularcableboxwithoutcable, optional with 2 m die casted cable -Straightcableboxwithoutcable, othersuponrequest Specialversion: -Silicone-freeversion - Versionfreeofgreaseanoil,upto0-600bar - Adjustment 250 bar with dry air 400 bar with distilled water - Oxygen version: up to max. 0-600 bar, restrictorscrewintheiminletportofthe connection,orifice0.3mm - Outputsignal0-5Vor1-10V,4-20mA(3-wire) -Othersensorsealing Ordering Information Pleasespecifyinyourorder: Basic model Order codeforabsolutepressure Pressure range Output signal Possiblespecifics: Example: PTM (a), 0-1 bar, 4...20 mA Sales and Export South, West, North Subsidiary Company, Sales and Export East AmGewerbepark9 D-08344Grnhain-Beierfeld Tel.:+49(0)3774/580Fax:+49(0)3774/58545 m a n o t h e r m . c o m m a i l @ m a n o t h e r m . c o m PTM (a) e.g. 0-6 bar e.g. 4...20 mA compareabove

Measuring Accuracy Betterthan 0.5%,offullscalevalue(includingnon-linearity, hysteresis and non-repeatabilty) formeasuringspans100,160, and 250 mbar 1.0% Temperature Ranges Storagetemperature: Ratedtemperature: -40...+125C(-40...+257F) -10...+80C(-14...+176F)

ARMATURENBAU GmbH

Manometerstrae 5 D - 46487 Wesel - Ginderich Tel.: +49(0) 28 03 / 91 300 Fax: +49 (0) 28 03 / 10 35 armaturenbau.com mail@armaturenbau.com

MANOTHERM Beierfeld GmbH

9810
00

03/11

Case Configuration, Dimensional Data and Weights, Wiring Diagram

PTM

Dimensional Data (mm) and Weights (kg) Model PTM Variant up to 0-100 bar > 0-160 bar I (mm) 88 (93) 97 (102) a (mm) 20 20 b (mm) 10 19 approx. weight 0.21kg 0.23kg

Thevaluesinbracketsarefortheoutputsignals0...20mA

Wiring Diagram 3-wire

(gn/gb)(ws)(gb)(bn)

operating voltage (UB)

output signal (Signal)

2-wire

(gn/gb)(ws)(gb) UBSignal

Technicalchanges,replacementofmaterialsanderrorsexcepted.
9810-03/11- GB- p2 of 2 ARMATURENBAU GmbH, Tel.: +49 (0) 2803/9130-0, E-Mail: mail@armaturenbau.com MANOTHERM Beierfeld GmbH, Tel: +49 (0) 3774/58-0, E-Mail: mail@manotherm.com, 03/11 DE