BENGKEL IBS SCORE

MAKLUMAT PROJEK 3 storey Medium Cost Flat 1. Structural System i) Beams ii) Columns iii) Floors iv) Roof Truss

= = = =

Precast Concrete beam Insitu Concrete using steel formworks Precast Half slab Prefabricated steel truss

2. Wall System

i) ii) iii)

Precast wall (external wall) Insitu Steel Formwork system (external wall) Precision Block system (internal wall)

Notes: Obmitt Staircase area and 4th floor (Service area) Obmitt ground floor wall (no wall)

'

IBS SCORE CALCULATION


ELEMENTS Part 1 : Structural Elements AREA (m2)/LenQth IBS FACTOR COVERAGE IBS SCORE

Total Part 1 Part 2 : Wall System

Total Dart 2

ELEMENTS
Part 3 : Other Simplified Construction Solutions

Total Part 3

IBS Score of Project = Part 1 + Part 2 + Part 3

MS 1064 : PART 4: 2001

SECTION 2 : COORDINATING

SIZES FOR DOORSETS

2.1

Scope

This Section specifies the coordinating sizes for doorsets of all material to be used in buildings, and which will fill coordinating spaces in dimensionally coordinated buildings.

. 2.2'

~'SpeclfiCation"

The range of coordinating sizes for external and internal doorsets is as shown in Figure 2.
) ) ) ) )

0)

)n

)(

'"

17~

6N

9M

101\1 12M

12M

15M

15M

15M

16M

21M

24M

I I / \

/ \ \ /
7

/ \ \ /
:z.a

/ \ \ /

21M

"I 2 3.

-----_ .._-

.,

....

f.

.,

'6

.,

"42

"43

"
/

".. "
44

,
"..'
.I

24M

,
f-

,
8

[,.~.-

L
\

/ \

~.
I
30

I., .~
\
J'

/. ) \
4S

L. S. "41

/. .~,
"47

I' 1/'- .-~, ..__ ._ ......

,
I-/

"
'0

><

I.-

~
/ \.

I-, /

24M
II

, ,
14

~
L-

~ ~, ~ v v

f',
32

12

1', 1/
3J

13

'5

f-

I-

, t,.. r; ~ f\, ~-, i.-- -, -, ".. , , "..' f', ",.,


/ /
"

"
52

.-'
"

1//

1/

1/
\ /

34

50

. 5\

27M

17

f-

, ..
I
2J

h
/

I--;;

I-.

1,./

-,
to

/ \11

10-,../ \ \ /

h.-/ \. \ /
7

1-_

h'-

,;,,~

/
24

-'
l/ r25 38

30M

\
2'
22

, ,

/ \

~'\
I

......,......,
I \

"
I
57

,
/

/"

-, 1,/ "
1[\

"
1'/ 56

1-,..-

>-,~
\ /
51

vi
f\.

\ I

\
39

\ I
40

\ I

,
9

,
I

'//

i',

"" -, ,
.I

1"/
60

SINGLE LEAF

I--SINGLELEAF AND SIDE LEAF

DOUBLElEAF

Figure 2. Recommended range of coordinating

sizes 'for doorsets

--------------~----------------------------~~~~~~~~~~.~--SECTION 2 : COORDINATING
-y

SIZES FOR WINDOWSETS

2.1

Scope
of all materials to be used in coordinated buildings.

This Section specifies the coordinating sizes for windowsets buildings, which will fill coordinating spaces in dimensionally

2.2

Specifications
sizes for windowsets shall be as shown in Figure 2.

The range of coordinating

'c' c

00

oc
8""'

oc

c 15M

oc
IBM

oc 21M

OC 24M

O(

/3~
30M

~N

1m

9M

1O""' 12M

27M

30M

::
27M
{

,. ..

24M

,
...

21M
0

IBM
.,

15M

12M 10M 9M 8M 7M 6M 3M

-'

.;

::

.;

::
-

Figure 2. Recommended range of coordinatinq sizes for windowsets


NOTE. M is the symbol for the basic module in MS 1064: Part 1 and having the value of 100 mm.
I

'1'

' p.,

'.

1064 : PART 10 : 2001

SECTION 3 : COMPONENTS

PREFERRED

SIZES

FOR

REINFORCED

CONCRETE

3.1

Scope

This Section specifies series of preferred sizes for reinforced concrete components to be used for buildings. The components included in this part are beams. columns. walls and slabs.

3.2

Specifications s:

The preferred sizes are categorised for various types of reinforced concrete components according to their intended function and use in a structural building system. Sizes mentioned are overall nominal dimensions, which shall account for joints and tolerances. The joint gap thickness, where applicabl.~shall be specified by the manufacturer to suit these applications. 3.2.1 Beams

The dimensions of preferred sizes for beams are shown in Table 5. They are either for in-situ or precast constructions. Table 5. Dimensions of preferred sizes for reinforced concrete beams
-v
.'
t'

. -- ..Types 'of buildings -_.

-_ .. -.

---Width--

.'.'-. .....__ ._-.__ Depth------

'.>

.'

Residential
.,.

150 200 250 300

,
Non Residential

300 350 400 450 500 550 600 400 450 500 550 600 700 800

--7>

200 250 300 350 400 500 600

NOTE. The dimensions, otpreterred sizes in the dimensions. Engineers are to carry out detailed appropriate preferred dimensions tor its intended but preferably with U1eincrement according 10 the above table are recommended sizes for the respective product design according 10 the relevant design code and select the use. Dimensions larger than stipulated in the table can be used recommendations.

3.2.2

Columns

The dimensions of preferred sizes for columns are indicated in Table 6.

Table 6. Dimensions of preferred sizes for reinforced concrete columns

Width

Length

" "", -,co ',' ,-~'"

150~, 260

,'d ~

250 300 350 400 450 ',; 500 550 600 650 700 750

aoo

150 200 250 300 350 400 450 500 550 600 650 700 750

",

apo
_._-_... ----.--..... -.--_.

.~

,-------.-.-NOTES:-----------.--'---,--'- .-----.------.

1. The dinensions for preferred sizes in the above table are recommended sizes for the respective product dimensions. Engineers are to carry out detailed design according to the relevant design code and select the appropriate preferred dimensions' for its Intended use, Dimensions larger than stipulated In the table can be used but preferably with the'increment according to the recommendations.'
.0

2. For preferred column height, refer to MS 1064 : Part 2.

3.2;3

Walls
-.ni: ~

The dimensions of preferred sizes b-

:;;;-<1 width are indicated in Table 7. i::::ar reinforced concrete walls

Table 7. Dimensions ~ ~..-.::~~

Width

Length

100 150 200 250 300 400

,~~'

,~.

600 .900 1200 1800 2400 3000 3600 4200

..

.......... -

..

NOTES:

1. The dimensions of preferred sizes in the above table are recommended sizes tor the respective product dimensions. Engineers are to carry out detailed design according to the relevant design code and select the appropriate preferred dimensions tor its intended use. Oirr..ensb"ls larger than stipulated in the table can be used but preferably with the increment according to the'T-ec:LJ:ce:~'" f
I'

2", For preferred wall height, reterto MS 1064: Par'; 2. ..

Slabs

... .

....

- -,._-

..

_ ... -"

-- .

.-- -...-.._- - --'


. !

3.2.4

The dimensions of preferred sizes for slab thickness and width are indicated in Table 8. Table 8. Dimensions of prefeneds:2=s~ reinforced concrete slabs

,
t

Thickness

~
!

Width

100 125 150 175 200


-y
.

\
I

600 900 1200 1800 2400 3000 3600 4200

..-

-_ .. -

NOTE. The dimensions of preferred sizes in t.':\.e at.... !:s.~ 'T#-' ~mended sizes for the respective product dimensions. Engineers are to carry out detailed ~~. ~ ... ..:.:..:.." the relevant design code and select the :0 appropriate preferred dimensions for its Intended use. OilT'~sicr.:;;';7=f than slipulated in the table can be used but ; preferably with the increment according to the recornm'?~.tior.'oS;

-,