EN 1991-1-5: CONTENTS
Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 General Classification of actions Design situations Representation of actions Temperature changes in buildings Temperature changes in bridges Temperature changes in industrial chimneys, pipelines, silos, tanks and cooling towers
Annexes
The elements of a loadbearing structure need to be checked to ensure that thermal movement will not cause overstressing of the structure, either by the provision of movement joints or by including the effects in the design.
Daily and seasonal changes in shade air temperature, solar radiation, re-radiation, etc., will result in variations of the temperature distribution within individual elements of a structure. The magnitude of the thermal effects is dependent on local climatic conditions, together with the orientation of the structure, its overall mass, finishes (e.g. cladding in buildings), and in the case of building structures, heating and ventilation regimes and thermal insulation.
y =
y +
y +
y +
y x
Indicative values of inner environment (T1 and T2) And Tout (i.e.Tmax + T1,T2 or T3 ) for buildings above ground, for regions between latitudes 45oN and 55oN
T CommentsCommentaires Season Characteristic Values of the temperature (C) Summer 20 Winter 25 Relative absorption depends on surface colour. (bright light surface) 0 Elements facing North-East 18 Elements facing South-West Summer Relative absorption depends on surface colour. (light coloured surface) 2 Elements facing North-East 30 Elements facing South-West Relative absorption depends on surface colour. (dark surface) 4 Elements facing North-East 42 Elements facing South-West
T1 T2 T3
T4
T5
Indicative temperatures Tout for underground parts of buildings For regions between latitudes 45oN and 55oN
T6 T7 T8 T9
Temperature for depth level, less than 1 m. Temperature for depth level, more than 1 m. Temperature for depth level, less than 1 m. Temperature for depth level, more than 1 m.
below the ground below the ground below the ground below the ground
EN 1995-1-1: Solar radiation effects T3, T4, and T5 for different building orientations
Building Surface Bright light surface Solar radiation effect T3 Building temperatures
4.5 9 0 N 13.5 W S 9 18 13.5 E 4.5
T4
16
9 2 N 23 W S 16 30 23 E 9
Dark surface
T5
23
13.5
The uniform temperature component of a structural element Tu is defined as: Tu = T T0 where: T is an average temperature of a structural element due to climatic temperatures in winter or summer season and due to operational temperatures. T0 is the temperature of a structural element at the relevant stage of its restraint (on completion)
When elements of one layer are considered and when the environmental conditions on both sides are similar, T may be approximately determined as the average of inner and outer environment temperature Tin and Tout.
Professor Haig Gulvanessian