CTV-5

P2871, P2872/AVST (71cm) COLOUR TELEVISION RECEIVER

SERVICE MANUAL

SECIFICATIONS
l l l l l l SYSTEM POWER INPUT POWER CONSUMPTION AERIAL IMPEDANCE TUNER RECEICING CHANNELS PAL/SECAM,B/G,D/K AC 180-240v(50/60Hz) 150W 75 OHM UNVALANCED VOLTAGE SYNTHESIZER TUNING VHF-L E2-S10 VHF-H E5-S41 UHF E21-E69 MAX.99 PROGRAM MEMORIES 28,110 5W X2 8W 8 OHM 2 AV SCART 1 FULL SCART 1

l l l l l

PROGRAMME PICTURE TUBE SOUND OUTPUT SPEAKER AV JACKS

CAUTION: Before servicing the chassis, read the Safely Precaution.

X -Ray radiation Precaution and Product Safety Notice on Page 2 of this manual.

X-RAY RADIATION PRECAUTION


1. Excessive high voltage can produce potentially hazardous X-RAY RADIATION. To Avoid such hazards the high voltage must not be specified limit. The normal value of the high voltage of this receiver is 28.5KV at zero beam current (minimum brightness) under 230V AC power source. The high voltage must not under any circumstances exceed 30KV. 2. Each time a receiver requires servicing the high voltage should be checked following the HIGH VOLTAGE CHECK procedure in this manual. It is recommended the reading of the high voltage be recorded as a part of the service record. It is important to use an accurate and reliable high voltage meter. 3. The primary source of X -RAY RADIATION in this TV receiver is the picture tube. For continued X-RAY RADIATION protection, the replacement tube must be exactly the same type tube as used in this TV receiver. 4. Some parts in this receiver have special safety-related characteristics for X-RAY RADIATION protection. For continued safety, parts replacement should be undertaken only after referring the PRODUCT SAFETY NOTICE below.

SAFETY PRECAUTION
WARNING: Service should not be attempted by anyone unfamiliar with the necessary Precautions on this receiver. The following are the necessary precautions to be observed before servicing this chassis. 1. Since the power supply circuit of this receiver is directly connected to the AC power line. An isolation transformer should be used during any dynamic service to avoid possible shock hazard. 2. Always discharge the picture tube anode to the CRT conductive coating before handling the picture tube. The picture tube is highly evacuated and if broken, glass fragments will be violently expelled. Use shatterproof goggles and keep picture tube away from the unprotected body while handling. 3. When replacing a chassis in the cabinet, always be certain that all the protective devices are put back in place, such as: nonmetallic control; knobs, insulating covers, shields, isolation resistor-capacitor, network, etc. 4. When replacing parts or circuit boards, disconnect the power core. 5. When replacing a high voltage resistor (metal oxide resistor) on circuit hoard, keep the resistor 10mm(1/2 in.) away from circuit board. 6. Connection wires must be kept away from components with high voltage or high temperature. 7. If any fuse in this TV receiver is blown, replace it with the FUSE specified in the chassis parts list. 8. The receiver is designed to operate with 230V(50Hz) AC mains.

PRODUCT SAFERY NOTICE


Many electrical and mechanical parts in this chassis have special safety-related characteristics are often passed unnoticed by a visual inspection and the X-RAY RADIATON protection afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage, read the pares list in this manual carefully. The use of substitute replacement parts that do not have the same safety characteristics as specified in the parts list may create shock, fire, X-RAY RADIATION or other hazards.

GENERAL ADJUSTMENT AUTOMATIC DEGAUSSING


An automatic degaussing coil is attached around the picture tube, degaussing the tube properly in about one second after the set is switched on. If the receiver is moved or faced on a different direction, the power must be switched off at least 15inutes in order that the automatic degaussing circuit operated properly. External is necessary if the automatic degassing proves ineffective affect the set is moved.

B+ ADJUSTMENT
CAUTION: To avoid X-ray hazards, B+ voltage must be set in the scale of 140V+/-0.5V.
1. Make sure the AC power supply is 230V, 50Hz. 2. Switch on the TV receiver, tune in an active channel. 3. Measure the voltage between C641 on Main P.C. Board DC voltmeter. 4. Set contrast, brightness, color to maximum. 5. Adjust VR631 on Main P. C. Board for B+140V+/-0.5V voltage reading.

HIGH VOLTAGE CHECK


CAUTION: There is no high voltage adjustment in this chassis, B+140V voltage directly
relates to the high voltage. The high voltage does not exceed 30KV under any conditions. 1. Connect an accurate high voltage meter to the second cap of the picture tube. 2. Turn on the receiver, set brightness and contrast to minimum (Zero beam current). 3. Make sure the high voltage does not exceed 30KV. 4. NO matter whether the luminance, contrast and chrominance controls are set to maximum or minimum, the high voltage must be kept under 30KV.

FOCUSING
Receive a TV test pattern signal; adjust controls for optimum picture. Adjust Focus Control for a well-defined, sharpest display in the center area of the screen.

ADJUSTMENT AND SERVICING THE VHASSIS


SERVICE MODE
To enter the service mode, a special remote control which contains a additional SERVICE key to setup the chassis in producing must be used. See the illustration. Press the SERVICE key on remote control, TV will display service menu as following table 1. To select the parameter requiring adjustment, use the P+/P- keys. To adjust the selected parameter, use the V+/V- keys. To quit the service mode, press the P.P. key on remote control when in the service mode. Table 1 CRT=A66EHJ43X01 FOR THOMSON

Parameter Red Gain DC Red Green Gain DC Green Blue Gain DC Blue Apr Threshold Logo

Value 48 032 48 032 48 032 8 6------------

mper 59 122 55 105 44 127 15 G

Apr Threshold: AUTOMATIC RGB PEAK REGULATION THRESHOLD. When the APR Feature (in OPTION2)is in ON. As soon as one of the RGB signals exceeds the APR Threshold, the gain for the RGB is decreased. Once the RGB signals are inferior to the APR Threshold, the is slowly increased.
Not: Logo parametresinin ilk karakteri logonun karakter Bizim G harfini girmemiz gerekiyor. CRT:A66EAK071X11 POS. NO R323 R804 N ASE ZERNDE DE MES GEREKEN MALZEMELER. New value YEN DEER .. 0.51R/2W M.O.R 5R6/2W M.O.R M.O.R uzunlugunu veriyor.

Old value ESK DEER 1R/2W 2R7/2W M.O.R

Logo: The Feature can be active by setting the Logo Display to ON status in OPTION1. You can use V+/V- keys to jump from one column to other. To access alphanumeric characters in the sequence A to Z ,+ , -, ,SPACE and 0 to 9 for P- key and in reverse order of sequence for P+ key. The first character indicates the length of the Logo Display on the screen, and it must be the one of the numeral 0-9 and the characters A,B,C. To enter the table 2, press the OK key for the first time on the remote control when in the service mode. Table 2 Service V3.0

1 5 9

2 6

3 7 -/-/

4 8

Parameter Tuner AGC H position VPOS 50 VPOS 60 VAMP 50 VAMP 60 Bright max Bright min Sub Tint VCO Coarse VCO Fine VCO Coarse L1 VCO Fine L1

Value 22 32 10 10 47 40 63 00 32 05 063 05 080

mper 18 33 63 00 32 07 052 -

H position: Horizontal position. VPOS50: Not to be used. VPOS60: Not to be used. VAMP50: Not to be used. VAMP60: Not to be used. VCO Coarse: For PAL/SECAM-BG/DK/I system. VCO Fine: For PAL/SECAM-BG/DK/I system. VCO Coarse L1: For SECAM-L/L system only. VCO Fine L1: For SECAM-L/L system only. To enter the table 3, press the OK key for the second time on the remote control when in the service mode. Table 3

STV9306

CRT=A66EHJ43X01 THOMSON

N ;

SAW50 SAW60 SH SC CC EW VDC EW AMP EW SHAPE EW TRAP

58 00 22 05 10 05 13 00 18

52 46 21 02 09 07 12 01 21

SAW50: Vertical deflection current for 50HZ. SAW60: Vertical deflection current for 60HZ. SH: Vertical shift. SC: S Correction. CC: C Correction. EW VDC: Horizontal width adjustment. EW AMP: Parabola amplitude.(Pincushion correction). EW SHAPE: Parabola shape. (Corner correction). EW TRAP: Trapezium correction. To enter the table 4, press the OK key for the third time on the remote control when in the service mode. Table 4 Design

Parameter AGC gain Option 1 Option 2 Option 3 Option 4 Option 5 ST Ttext H POS OSD V POS OSD H POS TXT V POS TXT

Value 00 32 00 03 11 00 00 TRKE 001 01 057 04

mper 00 49 00 35 11 05 00 001 01 057 12

OPTION1: B5=P/N/S Crystals application (0=2 crystals, 1=1 crystal) B4=Cutoff Loop (0= OFF, 1=ON) B3=Safety_Reset (0=Active, 1=non) B2=Super Tuner (0=OFF, 1=ON) B1=Sound Demodulation (0= Intercarrier/MONO, 1=QSS/NICAM) B0=Logo Display (0=OFF, 1=ON) OPTION2: (Its better to keep the default setting option2=0)

B5=Half_Contrast (0=OFF, 1=ON) B4=Color 6db (0=OFF, 1=ON) B3=APR Feature (0=ON, 1=OFF) B2=Black Stretch (0=ON, 1=OFF) B1=Auto Flesh (0=ON, 1=OFF) B0=Coring (0=ON, 1=OFF) OPTION3: B5=AVL (0=OFF, 1=ON) B4=PIF Over modulation (0=OFF, 1=ON) B3=Market_France-SECAM L/L (0=OFF, 1=ON) B2=Manual/Auto Cutoff (0=Manual, 1=Auto Cutoff) B1=Mute pin Low/High To control the speaker (0=Low, 1=High) B0=TDA7449/TDA7439 (0=TDA7449, 1=TDA7439) OPTION4: B4=SCART2 (0=OFF, 1=ON) B3=RGB (0=OFF, 1=ON) B2=SVHS (0=OFF, 1=ON) B1=AV2 (0=OFF, 1=ON) B0=AV1 (0=OFF, 1=ON) OPTION5 and ST Ttext is for teletext setting only. It normally cannt be changed.

A.F.C. ADJUSTMENT
Removing any R.F. signal source and prevent any stray signal source from entering the tuner by shorting the tuner input inner contact to the out screen. Inject the 38.9 MHZ carrier into the tuner IF output pin (pin 11).Select the parameter VCO Coarse in the service mode (Table 2).The VCO Statuswill appear on the screen. Then press the AV key on remote control, the CPU will adjust automatically until the VCO Status OK appears on the screen. If this can not be achieved, adjust the T201 first and then press the AV key on remote control, the CPU will adjust automatically once again until the VCO Status OK appears on the screen.

GEOMETRY
To adjust the picture position and vertical size, select the appropriate parameter in the service mode and adjust as necessary. SPECIFIVATION CTV FOR MODEL SUPPLY VOLTAGE GENERAL INFO LOAD INPUT ANT. : KENT P2871 TXT/AVST (71cm) PAL/SECAM B/G, D/K : AC 230V/50Hz(+/-10%) : TV 75 ohm : 8 ohm : 0Db=1uV

DESCRIPTION
1 MAX/USABLE SENS. VHF UHF CATV

UNIT
dB u V dB u V dB u V MV MV KHz

LIMIT 28
33/48 36/50 40/48

TES T

2 3 4

TELETEX SENS. STEREO SENS. AFC HOLDING RANGE SOUND MAX.OUTPUT (1KHz) THD OUTPUT10%(1KHz) REF.THD(1KHz) MONO/STEREO S/N MIN.HUM RESPONSE FH 7KHz/FL 120Hz STEREO SEPARATION (GERMAN) STEREO SEPARATION( NICAM) AUDIO INPUT AUDIO OUTPUT (10K OHM LOAD) LEFT/RIGHT CHANNEL RANGE TONE CONTROL RANGE BASS CONTROL (40Hz) TREBLE CONTROL (10KHz) PICTURE SCANNING SIZE SCANNING SIZE PATTERN DISTORTION LINEARITY LINEARITY WHITE BALANCE 9300 WHITE BALANCE 9300 LUMINANCE WHITE PATTERN) MAX

750;-

500

5 6 7 8 9 10 11 12 13 14 15 16

mW mW % dB mV dB dB dB Vrms Vrms dB dB dB

6000*2 5000*2 <3/3.5 <32 <20 -3+/-6

0.5+/-0.15 0.5+/-0.15

18 19 20 21 22 23 24 25

VERT. HOR. VERT. HOR. K X K Y (50%

% % % % %

90 90

Cd/m2

K 96 K 96 3.5 <8 <10 X=283+/-12 Y=297+/-12 >120

DESCRIPTION
27 RESOLUTION HORIZONTAL VERTICAL COLOUR SENSITIVTTY VIDEO INPUT VIDEO OUTPUT (75 OHM LOAD) SAFETY HI-POT TEST 31 32
INPUT VOLTAGE 230VAC AC:3000V 1 MIN 10mA INPUT VOLTAGE 230V AC:1200V 1 MIN 5mA

UNI T
LINE LINE dB u V Vp-p Vp-p

LIMIT 28
PAL 300 PAL 400 35 1+/-0.3 1+/-0.3

TES T

28 29 30

OK OK

33

CRT HIGH VOLTAGE (AT ZERO BEAM CURRNT)

KV

28 + 2 - 2

Remote control
35 36 DIRECTIVTY DIRECTIVTY 5m(MIN) 6m(MIN) 30 FROM LIGHT AXIS 8m(NOR ) 7m(NOR ) OK OK

15

12 MAIN BOARD HOLDER 11 DEGAUSSING COIL HOLDER

10 UNIT TIE 21 20 19 18 FRONT CABINET 17 KEY BOARD 16 S/T SCREW 4 15 REAR CABINET 14 REAR PANEL 13 MAIN BOARD 16 9 8 7 6 5 4 3 2 1 FRONTAL CABINET DEGAUSSING COIL BRAIDER FLAT WIRE CRT GROUND SPRING S/T SCREW 7 WASHER CRT S/T SCREW 4 10 30