You are on page 1of 6

Three-phase UPS

DELPHYS MX

from 250 to 900 kVA the Mega Power protection up to 5.4 MVA

DELPHYS MX range is capable of a maximum system size of up to 5.4 MVA and specifically designed for demanding Data centre applications such as large DTC of banks / insurances, IDC, Telecom

datacentres, semiconductor production lines and big automation manufactures, airports, big air traffic control centres, tunnels. DELPHYS MX, is a true-online double conversion UPS system which protects

the load from power grid pollution or power failure, from utility power supply and diesel generators.

COMPLIANT

Flywheel

B U R E A U VERITAS
DELPHYS MX series is attested by Bureau Veritas.

Your protection for

> Data center > Industry > Telecommunications > Processes

60

DefyS 176 A

Three-phase UPS

DELPHYS MX
from 250 to 900 kVA

Flexible architecture
Parallel system with modular units. Powerful central bypass for power extension or redundancy. Tier 3 and Tier 4 compatible. Designed for optimal use with STS in downstream network.

User-friendly operation and remote communication


Specially designed graphic touch screen for easy and ergonomic operation. 7 com-slots plug-in communication interfaces for upgrading your operating requirements. easy remote monitoring via web browser or via customers supervision systems (web, intranet, extranet). Very open connectivity (Modbus / Jbus, Jbus tunnelling, LAN).

Easy to Service and Maintain


front accessibility for all components. Reduced MTTR thanks to extractible power bridges or fans on cassette.

High reliability and availability


Internal fault tolerant architecture with internal redundancies and fan failure localisation. Intelligent embedded battery monitoring with failed block localisation and preventative remote alarm. Able to withstand an output short circuit and overload, ensuring the systems safety under extreme conditions. Reliable and robust paralleling mode. Multisystem automatic cross synchronisation (ACS) for an optimised use with STS. Output isolation transformer to reduce the influence of N-GND (Neutral Line-toGround) voltage and load harmonic current on UPS inverter.

Lower Total Cost of Ownership


Minimised running costs, by: - Very high efficiency of up to 93.5 % (lower energy dissipation and cooling costs) equals energy saving in full on line conversion, - energy saver on-line mode allows the number of running units of the system to adapt automatically to the real load, - free cooling compatible to save cooling costs. Valuable space saving with its reduced footprint and exceptional high power density (the most compact unit of its class): 900 kVA in less than 3.2 meters (width) per unit including the by-pass. DELPHYS MX units can also be installed without side or rear access (dependant on requirements). Lower infrastructure installation costs benefit from PfC clean input rectifier (without filters) with a lasting high input power factor whatever the operation conditions. It means lower input current, in comparison with traditional UPS, therefore no need to oversize upstream transformers or generator sets. Intelligent built-in battery monitoring system interacts with charging mode to prolong battery lifetime (reduced battery stress thanks to a very low ripple current). The independent charger permanently isolates the batteries from the inverter DC bus in normal mode. Designed to match latest IT load requirement. Leading power factor load compatible without derating.

APPLI 406 A

61

Three-phase UPS

DELPHYS MX
from 250 to 900 kVA

The voltage you require: whatever the load


DELPHYS MX ensures your power supply is of the utmost quality by using Space Vector Modulation (SVM) digital regulation: perfectly sinusoidal output voltage THDV < 2% with linear loads and < 3% with non-linear loads, output voltage precision even when load is completely unbalanced between phases, an immediate response to major variations in load, without deviating the output voltage (2%inlessthan5ms), averyhighshortcircuitcapacityupto4In (Ph / N) allows selectivity. Components and power bridges (integrating the latest high performance IGBT) enable the supply: non-linear loads with high crest factor up to 3, loads with a leading power factor up to 0.9 lagging without de-rating of the active power(900kVA/800kW).
LEADING
cos 0,9 1 0,75
DefyS 153 A GB

kW

LAGGING
cos 0,9

100% kW cos 1

% 00 10

0,50 Without derating 0,25

kv A kVa

-1

-0,8

-0,6

-0,4

-0,2

0,2

0,4

0,6

0,8

kVAr

Integration into your electrical network: a clean and economical rectifier


DELPHYS MX guarantees total compatibility with your low voltage electrical power supply system and, in particular, with generating sets: sinusoidal current at rectifier THDI input: 4.5 % without filter, increased power factor upstream of the rectifier: 0.93 without filter, reducing the current consumed, and therefore the size of cables and protective devices, gradual, sequential start-up of the rectifiers in parallel, facilitating take up by the generating set, delayed battery recharge when running on generating set to reduce power consumption.
THDI %
28 %

8%

9% 7% 3,2 % 5% 6% 2,5 % 4,7 % 2%

1%

H5
DefyS 171 A GB

H7

H11

H13

H17

H19 HARMONICS

Traditional three-phase rectier with thyristor 12 pulse rectier Low distortion rectier DELPHYS MX

Fault tolerant architecture


DELPHYS MX integrates internal redundancy that ensures permanent power supply even during system failure: redundant ventilation system, ring bus synchronisation, no single point of failure since the synchronisation bus uses a fault tolerant token ring topology that accepts an accidental opening of the synchronisation loop, without UPS malfunctioning or load losses and an alarm is given to the operator at the first fault. Cascade failure protection function eliminates fault propagation downstream of a module in parallel system when configured with central bypass, internal or external backfeed protection eliminates any risk of energy feedback upstream of the UPS, hardware and software watchdog ensures that the power supplied to applications is secure in case of a circuit and control software fault, redundancy of the power supplied to the electronics, locating ventilation faults, preventative detection of faults on a battery component on request.
GReeN 066 A

Protecting your battery investment EBS (expert Battery System) technology significantly prolongs the battery life: charge according to an algorithm which adapts to the environment and the condition of the battery, eliminates overloading effects due to permanent floating, which accelerates the corrosion of the positive plates and causes the separators to dry out, isolation of the DC battery bus, (independent charger function). Premature ageing, caused by residual ripple from the inverter bridge is eliminated.

Guaranteed battery availability the battery and DC circuit are regularly tested automatically and the operator is notified of their condition, Available as option, BHC Interactive (Battery Health Check), a battery monitoring system that provides permanent monitoring of the battery system, simplifies maintenance (either preventative or curative) and optimises battery lifetime. Interacting proactively with the battery charger recharging system (EBS), it optimises battery capacity, increases charger precision, performs automatic battery testing and automatic procedure to recover a block when becoming weaken before it is totally unusable.

T
UP S DE LP HY S Gr een Po we r

V I

62

Three-phase UPS

DELPHYS MX
from 250 to 900 kVA

Double conversion architecture


Maintenance Bypass Automatic Bypass Q5

Q4 Rectier Inverter Q3

Q1

Charger Q20

DefyS 088 B GB

Battery

Parallel architectures
To fulfil the most demanwding needs for power supply availability, for flexibility and for the installation to be upgraded. DELPHYS MX modular, growth without constraints (up to 6). DELPHYS M X with Static Transfer Systems: IT SWITCH and STATYS to provide security as close to the applications as possible.
DELPHYS MX

DefyS 167 A

DefyS 093 A

DELPHYS MX

DELPHYS MX centralised bypass, programmed growth.

STS 1

Load 1

STS 2

DefyS 094 A

Load 2

DefyS 180 A GB

DefyS 168 B

STS 3

Load 3

DELPHYS MX double bypass, for easier operation.

DefyS 169 A

DefyS 059 B

63

Three-phase UPS

DELPHYS MX
from 250 to 900 kVA

Graphic display
Design adapted to the user: control panel with LeDs and LCD display.

Graphic touch screen (GTS)


The operator has access to the control functions with only a few intuitive touches of the screen.
Direct access zones to sub-unit menus Operating mode icons Help menu for correct operation UPS load rate (bar graph) Quick access to each installation module
DefyS 102 A

DefyS 111 A GB

Access to installation mimic panel Preventative maintenance request

Status bar

Standard equipment
lotsfor7communicationcards. S Backfeed protection: detection circuit. Standard interface - inputs (emergency stop, generating 3 set, battery protection) - 4 outputs (general alarm, back-up, bypass, preventative maintenance needs). EBS (expert Battery System).

Accessories
BHC Interactive battery monitoring system. Graphic touch screen. ACS function for synchronisation with an external source. Reinforced IP protection degree. Ventilation filters. Ventilation control.

Communication options
Remote access panel. ADC (Advanced Dry Contacts) data input and output by dry contacts. RS232, RS422, RS485 serial connection JBUS / MODBUS, PROfIBUS. MODBUS TCP interface (JBUS / MODBUS tunneling). NET VISION ethernet Network interface (http web pages, email, SNMP, servers shutdown). Alarm notification via SMS.

Remote maintenance
T.SERVICE for continuous 24/7 monitoring via the SOCOMEC UPS maintenance service.

64

Three-phase UPS

DELPHYS MX
from 250 to 900 kVA

UPS and batteries


A compact and integrated system.
UPS UPS power kVA / kW 250 / 225 300 / 270 400 / 360 500 / 450 800 / 720 900 / 800 Width mm 1600 1600 1600 1600 3200 3200 Battery for back-up time 5 minutes Weight W2 kg mm 7565 4800 8735 4800 Battery for back-up time 10 minutes Weight W2 kg mm 3670 2400 3670 2400 4890 3200 5560 3200 9640 5000 11568 6000 Battery for back-up time 15 minutes Weight W2 kg mm 3770 2400 4600 3200 6110 4000 7115 4800 -

DefyS 181 A GB

W2

84

Central bypass cabinet


Coupling cabinet including the central static switch and the maintenance bypass.
Power(1) kVA 300 400 600 800 1200 2000 2400 3200 W mm 600 600 1000 1000 1200 2600 4000 5800 D mm 800 800 800 800 800 1200 1245 1245 Weight kg 270 300 420 450 600 2100 N/D N/D

Technical data
Sn [kVA] Pn [kW] RECTIFIER INPUT Rated input voltage(1) Voltage tolerance Rated input frequency Frequency tolerance Input current distortion THDI at rated input current Input power factor OUTPUT Rated output voltage Nominal output frequency Output frequency tolerance Total output voltage distortion - linear load Total output voltage distortion - reference nonlinear load (lEC 62043-3) Short-circuit capability Overload capabilty Output power factor without derating in kVA or kW BYPASS Rated input voltage Input voltage tolerance Rated input frequency lnput frequency tolerance EFICIENCY Normal mode ECO-MODE ENVIRONMENT Ambient storage temperature Ambient service temperature Altitude Relative humidity range Acoustic noise at 1 m (ISO 3746)(2) UPS CABINET Dimensions (W x D x H) (mm) Weight (kg) Degree of protection (IEC 60529) STANDARD COMPLIANCE Safety EMC Performance and test Product comformity 250 225 300 270 400 360 500 450 800 720 900 800

380/400/415 Vac 340 to 460 V 50/60 Hz 5 Hz < 4.5% 0.93 380/400/415 V 50/60 Hz 0.2% < 2% < 4% 125% 10 min - 150% 1 min 0.9 lagging to 0.9 leading 380/400/415 V 10% 50/60 Hz 2 Hz (0.2 Hz to 4 Hz settable) up to 93.5% 98%

360 to 460 V

(1) For other power ranges, please contact us.

3.5 In 100 ms

DefyS 086 A GB

Bypass transformer
for galvanic isolation.
Power(1) kVA 300 400 500 600 800 1000 1200 W mm 1000 1200 1200 1200 1200 1200 1600 Weight kg 800 1000 1500 1800 2000 2500 2700

1930

-20 C to +70 C 25 C (recommended) ; 0 to 35 C without derating 1000 m without derating 95% max without condensation 70 dBA 72 dBA 75 dBA 1600 x 995 x 1930 2650 3000 IP20 standard 3200 x 995 x 2210 5900

2300

(1) For other power ranges, please contact us.

IEC 62040-1; EN 62040-1; IEC 60950-1 IEC 62040-2; EN 62040-2 IEC 62040-3 CE

(1) DELPHYS MX 250-500: three-phase 220-230-240 V on demand. (2) As per power range.

DefyS 087 A GB

80

1930

1930

< 5% 0.94

< 3%

DCG_84073

VALID FOR FRANCE

VALID FOR ITALY

www.socomec.com
ISO14001 EMS 553476

ISO 9001 FM 28237

Non contractual document. 2011, Socomec SA. All rights reserved.

65

You might also like