CODE Description
201 202 300 301 302 303 306 307 308 309 310 311 312 313 319 320 330 331 332 333 340 341 342 343 349 350 401 402 403 404 405 406 407 408 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 437 438 439 440 441 442 443 444 445 446 447 448 606 608 609 610 611 612 613 700 701 702 705 707 708 709 711 LH Movement disabled RH Movement disabled LH Pressed Key Backrest up LH Pressed Key Backrest down LH Pressed Key Seat Angle up LH Pressed Key Seat Angle down LH Pressed Key Legrest up LH Pressed Key Legrest down LH Pressed Key Legrest extension out LH Pressed Key Legrest extension in LH Pressed Key Fixpos TTL LH Pressed Key Fixpos LAZY1 LH Pressed Key Fixpos PERSONAL LH Pressed Key Fixpos BED LH Pressed Key Fixpos LAZY2 LH Pressed Key Fixpos DINNER RH Pressed Key Backrest up RH Pressed Key Backrest down RH Pressed Key Seat Angle up RH Pressed Key Seat Angle down RH Pressed Key Fixpos TTL RH Pressed Key Fixpos LAZY1 RH Pressed Key Fixpos PERSONAL RH Pressed Key Fixpos BED RH Pressed Key Fixpos LAZY2 RH Pressed Key Fixpos DINNER LH Backrest up overcurrent LH Backrest up di/dt LH Backrest down overcurrent LH Backrest down di/dt LH Seat angle down overcurrent LH Seat angle down di/dt LH Seat angle up overcurrent LH Seat angle up di/dt LH Legrest up overcurrent LH Legrest up di/dt LH Legrest down overcurrent LH Legrest down di/dt LH Legrest ext. out overcurrent LH Legrest ext. out di/dt LH Legrest ext. in overcurrent LH Legrest ext. in di/dt LH Seat height BED->TTL overcurrent LH Seat height BED->TTL di/dt LH Seat height TTL->BED overcurrent LH Seat height TTL->BED di/dt RH Backrest up overcurrent RH Backrest up di/dt RH Backrest down overcurrent RH Backrest down di/dt RH Seat angle down overcurrent RH Seat angle down di/dt RH Seat angle up overcurrent RH Seat angle up di/dt RH Legrest up overcurrent RH Legrest up di/dt RH Legrest down overcurrent RH Legrest down di/dt RH Legrest ext. out overcurrent RH Legrest ext. out di/dt RH Legrest ext. in overcurrent RH Legrest ext. in di/dt RH Seat height BED->TTL overcurrent RH Seat height BED->TTL di/dt RH Seat height TTL->BED overcurrent RH Seat height TTL->BED di/dt CAN BUS Failure (in fault tolerant mode) Power Supply A defect Power Supply B defect Power Supply A partly defect Power Supply B partly defect Power Supply A BITE failed Power Supply B BITE failed LH Backrest Power A fail LH PCU CAN error RH PCU CAN error LH Seat angle Power A fail LH Legrest Power A fail LH Legrest extension Power A fail LH Seat height Power A fail LH Backrest CAN error

11.05.2007

Details
An error caused the deactivation of movement An error caused the deactivation of movement This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed This Key is pressed Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected Actuator current limit exceeded, pinching detected

Action
See other Failurecodes for reason See other Failurecodes for reason If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU If codes not match to the pressed keys, check IPCU Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics Analyse actuator or kinematics

Disconnect unit by unit and check which one causes this error Seat has only the half power Replace EPS Seat has only the half power Replace EPS 24V Power OK, but no redundancy on power supply, breakdown Replace EPS 24V Power OK, but no redundancy on power supply, breakdown Replace EPS Power supply cannot be switched off Replace EPS Power supply cannot be switched off Replace EPS Power line at actuator is not OK EPS internally defect EPS internally defect Power line at actuator is not OK Power line at actuator is not OK Power line at actuator is not OK Power line at actuator is not OK Cable failure or unit defect Check cable Replace EPS Replace EPS Check cable Check cable Check cable Check cable Check flat cable connection

712 714 715 716 719 721 722 724 725 726 728 738 739 740 741 743 744 745 747 748 750 751 753 754 755 757 775 776 778 779 780 782 783 785 786 787 900 901 902 905 908 909 910 911 912 914 915 916 920 921 922 924 925 926 940 941 943 944 945 947 950 951 953 954 955 957 971 972 974 975 976 978 979 981 982 983

LH Seat angle CAN error LH Legrest CAN error LH Legrest extension CAN error LH Seat height CAN error RH Backrest Power A fail RH Backrest CAN error RH Seat angle CAN error RH Legrest CAN error RH Legrest extension CAN error RH Seat height CAN error RH Seat angle Power A fail RH Legrest Power A fail RH Legrest extension Power A fail LH Backrest failure LH Seat angle failure LH Legrest failure LH Legrest extension failure LH Seat height failure LH PCU failure RH Seat height Power A fail RH Backrest failure RH Seat angle failure RH Legrest failure RH Legrest extension failure RH Seat height failure RH PCU failure LH Backrest Power B fail LH Seat angle Power B fail LH Legrest Power B fail LH Legrest extension Power B fail LH Seat height Power B fail RH Backrest Power B fail RH Seat angle Power B fail RH Legrest Power B fail RH Legrest extension Power B fail RH Seat height Power B fail CAN-BUS Breakdown A LH PCU Lost communication A RH PCU Lost communication A Parameter Download Error PAX LH and RH swapped More Pax installed than configured A A A A A A A A A A A A SEAT LH Lost Communication LH Backrest lost communication LH Seat angle lost communication LH Legrest lost communication LH Legrest extension lost communication LH Seat height lost communication SEAT RH Lost Communication RH Backrest lost communication RH Seat angle lost communication RH Legrest lost communication RH Legrest extension lost communication RH Seat height lost communication

Cable failure or unit defect Cable failure or unit defect Cable failure or unit defect Cable failure or unit defect Power line at actuator is not OK Cable failure or unit defect Cable failure or unit defect Cable failure or unit defect Cable failure or unit defect Cable failure or unit defect Power line at actuator is not OK Power line at actuator is not OK Power line at actuator is not OK Poss. reasons: Overtemp, Temp Sens., Mot. Driver def. Poss. reasons: Overtemp, Temp Sens., Mot. Driver def. Poss. reasons: Overtemp, Temp Sens., Mot. Driver def. Poss. reasons: Overtemp, Temp Sens., Mot. Driver def. Poss. reasons: Overtemp, Temp Sens., Mot. Driver def. Communication to Rockwell IPCU is not full OK Power line at actuator is not OK Poss. reasons: Overtemp, Temp Sens., Mot. Driver def. Poss. reasons: Overtemp, Temp Sens., Mot. Driver def. Poss. reasons: Overtemp, Temp Sens., Mot. Driver def. Poss. reasons: Overtemp, Temp Sens., Mot. Driver def. Poss. reasons: Overtemp, Temp Sens., Mot. Driver def. Communication to Rockwell IPCU is not full OK Power line at actuator is not OK Power line at actuator is not OK Power line at actuator is not OK Power line at actuator is not OK Power line at actuator is not OK Power line at actuator is not OK Power line at actuator is not OK Power line at actuator is not OK Power line at actuator is not OK Power line at actuator is not OK One unit breaks down the communication EPS internally defect EPS internally defect This failure should not occure Perhaps the connectors P3 and P4 are swapped The PAX configuration do not fit to installed PAXs No communication with complete pax Cable failure or unit defect Cable failure or unit defect Cable failure or unit defect Cable failure or unit defect Cable failure or unit defect No communication with complete pax Cable failure or unit defect Cable failure or unit defect Cable failure or unit defect Cable failure or unit defect Cable failure or unit defect Possible reasons: Pos. Sens., Motor or driver, overtemp Possible reasons: Pos. Sens., Motor or driver, overtemp Possible reasons: Pos. Sens., Motor or driver, overtemp Possible reasons: Pos. Sens., Motor or driver, overtemp Possible reasons: Pos. Sens., Motor or driver, overtemp Communication to Rockwell IPCU not OK Possible reasons: Pos. Sens., Motor or driver, overtemp Possible reasons: Pos. Sens., Motor or driver, overtemp Possible reasons: Pos. Sens., Motor or driver, overtemp Possible reasons: Pos. Sens., Motor or driver, overtemp Possible reasons: Pos. Sens., Motor or driver, overtemp Communication to Rockwell IPCU not OK Auto-Configuration error Auto-Configuration error Auto-Configuration error Auto-Configuration error Auto-Configuration error Wrong actuator installed Wrong actuator installed Wrong actuator installed Wrong actuator installed Wrong actuator installed

Check flat cable connection Check flat cable connection Check flat cable connection Check flat cable connection Check cable Check flat cable connection Check flat cable connection Check flat cable connection Check flat cable connection Check flat cable connection Check cable Check cable Check cable Let unit cool down, otherwise replace unit Let unit cool down, otherwise replace unit Let unit cool down, otherwise replace unit Let unit cool down, otherwise replace unit Let unit cool down, otherwise replace unit System failure Check cable Let unit cool down, otherwise replace unit Let unit cool down, otherwise replace unit Let unit cool down, otherwise replace unit Let unit cool down, otherwise replace unit Let unit cool down, otherwise replace unit System failure Check cable Check cable Check cable Check cable Check cable Check cable Check cable Check cable Check cable Check cable Disconnect unit by unit and check which one causes this error Replace EPS Replace EPS Special diagnostic necessary Swap P3 and P4 connectors at EPS Change PAX configuration in service menu Check cable from EPS to PAX Check connection or replace unit Check connection or replace unit Check connection or replace unit Check connection or replace unit Check connection or replace unit Check cable from EPS to PAX Check connection or replace unit Check connection or replace unit Check connection or replace unit Check connection or replace unit Check connection or replace unit Replace Unit Replace Unit Replace Unit Replace Unit Replace Unit Check cable or replace IPCU Replace Unit Replace Unit Replace Unit Replace Unit Replace Unit Check cable or replace IPCU Check 9xx codes and replace defect unit Check 9xx codes and replace defect unit Check 9xx codes and replace defect unit Check 9xx codes and replace defect unit Check 9xx codes and replace defect unit Check these actuators and replace thw wrong Check these actuators and replace thw wrong Check these actuators and replace thw wrong Check these actuators and replace thw wrong Check these actuators and replace thw wrong

LH Backrest breakdown LH Seat angle breakdown LH Legrest breakdown LH Legrest extension breakdown LH Seat height breakdown A LH PCU breakdown RH Backrest breakdown RH Seat angle breakdown RH Legrest breakdown RH Legrest extension breakdown RH Seat height breakdown A RH PCU breakdown Backrest actuators not assignable Seat angle actuators not assignable Legrest actuators not assignable Legrest extension actuators not assignable Seat height actuators not assignable Too much Backrest actuators Too much Seat angle actuators Too much Legrest actuators Too much Legrest extension actuators Too much Seat height actuators A =Autoreset on this error

Special keyboard combinations