Award-winning user
friendliness
Common mechanical
concept
•Backwards compatible
with footprint of VLT 2800
+ VLT 8000
Flexible mounting
•Horizontal
•Vertical
•True side-by-side
Global labelling
•CE marked according to:
•C-tick approval
•UL and cUL approvals
Saves considerably
Space in panels
Footprint:
- up to 57 % smaller Former width
New width,
Volume B5
FP 15%
VL 11%
• Disconnect switch
Back channel
exhaust air
Internal Internal
exhaust air exhaust air
Back channel
exhaust air
IP54 Seal
Internal Internal
inlet air inlet air
Back channel
Back channel inlet air
inlet air
Confidential / Property of 9 August, 2008
Value
Fan controlled by
internal temperature
Energy saved
Less acoustic noise
Protects against
pollution, moisture,
and dust
Increase drive lifetime
• Relay option
+ 3 relay outputs
• Relay option
• General purpose I/O
+ 3 digital inputs
+ 2 digital outputs
+ 2 analogue inputs
+ 1 analogue output
• Relay option
• General purpose I/O
• Aqua I/O option
+ 3 PT/NI 1000
analogue input
+ 3 analogue output
• Relay option
• General purpose I/O
• Aqua I/O option
• Fieldbusses
– Modbus RTU (Standard)
– Profibus
– Device net
– Ethernet (April 2007)
– Modbus TCP (late 2007)
• Relay option
• General purpose I/O
• Aqua I/O option
• Fieldbusses
• Cascade control
– Extended 5 relays
– Advanced 8 relays
• Relay option
• General purpose I/O
• Aqua I/O option
• Fieldbusses
• Cascade control
• Relay option
• General purpose I/O
• Aqua I/O option
• Fieldbusses
• Cascade control
• Real Time Clock with
24V backup
Value
Customized units
assembled and
tested in the factory
• Reliability
• Quick and low cost
installation
Option of 2 Displays
(graphical and numerical)
“Blind cover” available
• Award winning
graphical display
• Easy navigation and
troubleshooting
• Quick learning
Value
Confidential / Property of 9 August, 2008
3 levels filtering
available, complies IEC
61800-3
Value
Unscreened up to 300m
Flexibility in
project planning
No need for
external filters
DC-coils are
built-in standard
• Reduced installation cost
• Smaller transformer
and cables
Value
Automatic Motor
Adaptation (AMA)
• Optimizes motor
performance
• Higher system efficiency
• Simple and optimum
commissioning
Value
Confidential / Property of 9 August, 2008
Value
Confidential / Property of 9 August, 2008
Built-in energy
measurement tool
Value
Confidential / Property of 9 August, 2008
Automated
skip frequencies
Preventive maintenance
• Reduces system stress
• Reduces
commissioning time
• Easy to avoid
system resonance
• Quick setup of the
frequency bands
• Personal menu
can be customised Quick Setup
Analog
reference
Closed loop
Settings
Menu Structure
Confidential / Property of 9 August, 2008
My Personal Menu
Quick Setup
General
General Clock settings
Function Setup settings LCP Display settings
settings
Analogue outputs
Relays
Changes Made Openloop
loop
Open Digital Reference
settings
settings Analog Reference
Loggings
Closedloop
loop
Closed Feedback Settings
settings
settings PID Settings
Provides access to
”Onboard Manual”
Available “on-site”
• No need for
a printed manual
• It’s ”always there”
Up to 5 variables…
• User-defined Display
• Display values with units
(kPa, Bar, mmHq, kWh and…)
• Simple monitoring of
logged data
• Graphs and bars
• Multiple font size
• Icons
• International letters,
numbers and signs
Alarm messages/log:
Full text messages
Customised texts
Customised display:
Text and values
Easy and improved
monitoring/fault finding
Graphical data log
Undo-function:
Resets latest change
Hand-Off-Auto on keypad
Standard RS-485
• MODBUS RTU
• Danfoss FC
Optional
• Profibus
• DeviceNet
• Ethernet
• Modbus TCP
Standard cable-glands
Pluggable terminals
(up to 7,5kW)
Screwed terminals
(11 – 90kW)
• Spring loaded
connections
• Pluggable terminals
– Quick installation
– Reliable system
– Vibration proof
– loop connection
Built-in Intelligence
Advanced process control
4 x PID controllers
• 1 controller for the drive
• 3 controllers for other
process equipment
• Eliminates need for
secondary controllers
• Provides flexibility
for SCADA
Step 1 of 4
Stabilize with fixed speed 3 acceptable curve periods Drive runs in closed loop
Example
Confidential / Property of 9 August, 2008
Speed
Feedback
3-zone feedback
• Increased control
flexibility
• Improves system by
using the average of
feedbacks
20 actions can
be triggered
• Eliminates need
for external timers
• Increased flexibility
20 actions items
can be scheduled
• Helps planned
system maintenance
• More reliable water and
waste water system
Example
Condition
Control off
Pump
Operation
Shut off
Stop command
Less than
Start pump Pressure
Setpoint
Pipe
Compare pressure
• Catch motor
in both directions
• Maintains pressure in
case of short voltage
drop-out
Cascade Controller
built-in as standard
• Staging / destaging
• Possible alternation
• Pump Cycling
• Pump Interlocking
Sleep Mode
• Based on low flow
• Boost function
• Internal or external
signal to enter sleep
mode
• Maximizes energy
savings
• Reduces wear on
equipment
Time
Flow compensation
at setpoint
• Simplifies sensor
installation
• Mount the pressure sensor
close to the pump
• Easy installation
• Reliable system
• Saves money
• Saves energy
VLT Software
VLT® Set-up Software MCT 10
2/2
Confidential / Property of 9 August, 2008
•Set up feedback
•Set up Setpoint
Cascade CTL
configuration tool
•Set up cascade
1/2
Confidential / Property of 9 August, 2008
PC tool to
calculate
Return on
Investment,
Payback Time
Generated
Reports:
• Spare parts
• Hotline support
• Preventative service
• Service
around-the-clock
• Global service network