Professional Documents
Culture Documents
The Powerware 3105 uninterruptible power system (UPS) protects your sensitive electronic equipment from basic power problems such as power failures, power sags, power surges, and line noise.
Features:
Eight outlets -Four with surge and battery backup protection -Four with surge protection only Data Line (Internet faxmodemDSL) or telephone line surge protection jacks Cold Start capability Proprietary LanSafe Power management software User-replaceable batteries Built-in USB communication port Compact design fits on/under your desk; can also be mounted to a wall Convenient transformer block spacing
spikes.) CAUTION: Do NOT plug LASER PRINTERS into the Battery Backup outlets. CAUTION: Do NOT plug ACCESSORY SURGE strips into the Battery Backup outlets. 3. Plug your peripheral equipment or non-critical loads (printer, scanner, fax, speaker, etc.) into the Surge Protection outlets. (These outlets provide surge and spike protection only, they will NOT provide battery backup power during a utility power failure). 4. Connect your computer to the UPS using USB cable provided. 5. With your equipment turned off, switch on the UPS. 6. When the On/Off LED light is illuminated, turn on the connected equipment. 7. Install Power management software provided with the UPS
INDICATORS
6 5
SAFETY INSTRUCTIONS
Once you have received the Powerware 3105 UPS product, you should remove and inspect the product for shipping damage. If any damage is found, please notify the carrier and your dealer. Please keep the shipping carton and the packing foam in the event the product must be returned to the factory for service. ATTENTION: Maintenance must be performed by a qualified personnel. Failure to do so could result in an electric shock. Replace Battery with Powerware supplied Battery ONLY! Although the unit may be unplugged from utility power, hazardous voltage still may be present through the battery. 1.Place the Powerware 3105 UPS indoors in an area that has adequate airflow and is free of excessive dust. Do NOT allow the UPS to be exposed to moisture, rain, excessive heat, or direct sunlight. 2.Use of the Powerware 3105 UPS product in life support applications, where failure of this equipment can reasonably be expected to cause failure of life support equipment or to significantly affect its safety or effectiveness is NOT recommended. 3.Disconnect the input power cord from the wall outlet before replacing the battery. 4.When replacing the battery, use the same number and type of battery 5.Do NOT dispose of battery in a fire. The battery may explode. 6.Do NOT open or mutilate the battery. They contain an electrolyte that is toxic and harmful to the skin and eyes. 7.Proper disposal of the battery is required. Please refer to your local laws/regulations regarding battery disposal. 8.Use tools with insulated handles to replace the battery to avoid personal injury. Due to energy hazard, please remove wristwatches and jewelry such as rings when replacing battery.
1 2
3 4 8
1.On/Off Push Button Switch One switch controls the power to your equipment. Upon power turn on, unit performs a self-test. NOTE: Turn on the UPS Press the push button switch locked in to turn on the UPS. NOTE: Turn off the UPS Press the push button switch again to turn off the UPS. NOTE: Self-Test The UPS performs a self-test for about 3 seconds when the UPS is turned on. 2.On/Off Battery LED Indicates the UPS is on and is powering your equipment. A constantly illuminated LED indicates normal utility power operation. A blinking LED indicates that the UPS is providing power from its battery. 3.Fault/Warning LED Indicates a fault or warning condition is present. A constantly illuminated LED indicates a fault or output SHORT condition. A blinking LED indicates the UPS is overloaded or BAD battery condition.
Push the top center Edge of battery cover forward and remove the battery cover
Pull out the battery onto a flat, stable surface and connect the black battery cable to the battery terminal
Reinstall the battery into the UPS 700VA model (12V-7AH battery)
4.Battery Backup & Surge Protection Outlets Four 5-15R output receptacles that provide both battery backup and surge protection. 5.Surge Protection Outlets Four 5-15R output receptacles that provide surge and spike protection. 6.Data /Phone/Fax Protection Connectors RJ11/RJ45 7.USB Communication Port The provided LanSafe monitoring and shutdown software can be automatically configured to save your files and shut down your computer in the event of a prolonged power outage. Your personal computer can receive the status of utility power line, utility power failure, on battery and low battery by contact closure signals that are sent through the USB port. 8.Circuit Breaker (resetable) The button protrudes when an overload condition occurs. If the button protrudes, disconnect some non-essential equipment and reset the circuit breaker by pushing the button inward. 9. Power Cord 5-15P plug type attached - 6 foot line cord
Push the top center Edge of battery cover forward and remove the battery cover
Pull out the battery onto a flat, stable surface and connect the black battery cable to the battery terminal
Removed all connected equipments from the UPS and charge the battery at least 8 hours. During this charging period, turn off the UPS to prevent unnecessary discharging. Call for service or you can replace the battery by ordering one from your dealer. Reduce the amount of equipment plugged into the outlets of the UPS. Try reducing the load by removing one piece of equipment at a time to determine if the problem continues. The UPS will turn off when the battery has been depleted during an extended power outage. Allow the UPS to re-charge the battery, before continuing on battery opera tion. Ensure the equipment that is to be protected from a power outage is plugged into the Battery Backup & Surge Protection outlets. Contact Powerware Technical Support
When utility power fails, The UPS is overloaded. connected equipment loses power
9
Equipment is connected to the surge Protection outlets. The UPS may require service.
STATUS INDICATORS:
The UPS provides both visual and audible status indicators. Visual indicators consist of two LEDs to represent the following conditions: On utility power operation On battery power operation UPS fault/alarm
Buzzer
B1 X X B2 B4 B1 B4 B3 ON B5
Notes: Blink 1: ON 0.5 seconds / OFF 0.5 seconds. Blink 2: ON 0.25 seconds / OFF 0.25 seconds. B1: 1 beep / 5 seconds, ON 0.25 seconds / OFF 4.75 seconds. B2: 3 beeps / 30 seconds, ON 0.25 seconds / OFF 0.25 seconds 3 times, 28.5 seconds OFF.
B3: 2 beeps / 5 seconds, ON, 0.25 seconds / OFF 0.25 seconds 2 times, 4 seconds OFF. B4: ON 0.5 seconds / OFF 0.5 seconds. B5: 3 beeps / 5 seconds, ON 0.25 seconds / OFF 0.25 seconds 3 times, 3.5 seconds OFF.
SPECIFICATIONS
Model Numbers PW3105 350 PW3105 500 PW3105 700 Nominal Input Voltage Nominal Output Voltage Frequency Total 8 Outlets Lighting / Surge Protection Transfer Time to Battery/AC Battery Type Battery Specification Typical Backup Time Internet / Phone / Fax Protection Short Circuit Protection Communication Port Operating Temperature Operating Relative Humidity Storage Temperature Net Weight Dimensions (W x D x H) Capacity 350 VA / 210W 500 VA / 300W 700 VA / 420W 120Vac 120Vac 50 / 60 Hz auto sensing 4 Battery Backup & Surge Protection 4 Surge Protection only 320 Joules 6ms Typical Maintenance free, Sealed and leak proof lead-acid battery 350 / 500 VA: 12V 5 AH 750 VA: 12V 7 AH 3 minutes minimum at full rated load RJ11/RJ45 Circuit Breaker USB 0 C to 40 C 0 to 95% non-condensing -15 C to 50C 350VA-9.5 pounds / 4.3 kg 500VA-11.7 pounds / 5.3kg 700VA-14.3 pounds / 6.5kg 11 x 7 x 4.4 i n.
* Due to continuing product improvement programs, specifications subject to change without notice.
TROUBLESHOOTING
Symptom
UPS will not turn on
Possible Cause
The battery is disconnected or utility power is not available at the wall outlet. Input Circuit Breaker has tripped.
Action to Take
Connect the battery (see Connect Battery) and ensure power is available at the wall outlet. Reduce the amount of equipment plugged into the outlets of the UPS. Next, reset the circuit breaker by pushing the plunger back in. Turn off the UPS and reduce the amount of equipment connected to these outlets.
UPS is making a The Battery Backup & continuous sound and Surge Protection outlets the Overload indicator are overloaded. is lighted.
MA6B411002A(2005/01/25)