Technical Data Sheet

AC UPS System PDW 3000 I 10 - 220 kVA Three Phase

Technical Data / PDW 3000


UPS Input Rectifier input voltage Voltage tolerance: DC in tolerance for function Bypass input voltage Frequency Inrush current Voltage Rectifier voltage tolerance Float voltage range at -10% mains Boost voltage range at nominal mains Boost charge time Charging current limitation Inverter input range (Output tolerance +/-1%) Inverter maximum input range (Output tolerance +/-10% Nominal UPS rating Voltage Voltage tolerance: static within 0-100% symmetric load static within 0-100% asymmetric load dynamic at 100% load surge regulation time Overload: Inverter 1 min Inverter 10 min Bypass 100 ms Short-circuit Inverter 50 - 100 ms Frequency Frequency stability, free running Synchronization range Slewrate single unit Slewrate redundant system Wave form Output crest factor admissible Distortion factor: Linear load Non liear load according to IEC 62040-3 Allowable power factor Fault clearing capability Ambient temperature range for storage Ambient temperature range for operating Altitude above sea level Allowable air humidity Noise level standard n+1 fan system Noise level 100% redundant fans Degree of protection Painting Standarts: Safety EMC Performance UPS Classification Conformity Efficiency Cooling Data subject to changes 3x380/400/415V +/-10% +10/-15% 3x380/400/415V +/-10% 50/60Hz +/-6% <10x IN (Input current) 110/125/220/400VDC +/-1% IU characteristic 100 - 115% programmable 100 - 125% programmable 1-24h programmable depending on battery programmable +20/-15% typical +/-25% kVA at PF 0.8 lag 3x380/400/415V +/-1% +/-3% +/-4% <25 ms 150% 125% 1000% 200% 50/60 Hz <0.01% 0.5/1/2/4/6/8% programmable 0.25/0.5/1/2/4 Hz/s programmable 1.0 Hz/s sinusoidal unlimited =< 3% =< 5% 0.4lag - 0.9 lead 30% of UPS nom. current rated gG fuse (IEC 60269) within 10 ms and bypass available from -20 to +70 C form -10 to +40 C (100% nominal load) 1000 m without load derating <95% (non condensing) 60 - 70 dBA depending on type 65 - 75 dBA depending on type IP20 according to IEC 60529 pebble grey, RAL 7032 structured IEC / EN 62040-1-2 IEC 62040-2, EN 50091-2 IEC / EN 62040-3 VFl - S S - 1 1 1 acc. to IEC 62040-3 (TV approved) CE-Label up to 93% depending on type forced ventilation with redundant n+1 monitored fans

Intermediate DC Circuit

UPS Output

General Data

Specification / PDW 3000


Typical Single - Line Drawing Options Parallel redundant configuration Other input voltages (190-690 V) Frequency 60Hz +/- 6% 12-pulse Rectifier with Isolation Transformer Larger Rectifier +1 step* / +2 steps* Rectifier fuse Bypass input switch Bypass input MCCB Rectifier input MCCB Sensor for temperature dependent battery charging voltage, recommended for sealed batteries and wide temperature range Battery temperature alarm Serial diode ( for parallel Rectifiers ) Diode for reverse polarity protection Rectifier output isolator Rectifier output circuit breaker Battery fuse in UPS Battery fuse box Battery MCCB in UPS Battery MCCB box Inverter input isolator Inverter input circuit breaker Larger inverter Power Module +1 step* / +2 steps* Static Switch EA ( Inverter side ) Manual Bypass 3 pos in UPS Battery Monitor ( programmable battery data ) Battery asymmetry supervision DC earth fault alarm AC earth fault alarm RS 232 Interface (event log download) RS 485 Interface RJ 45 Ethernet port for WEB browser based monitoring RS 485 MODBUS Protocol (slave) External time synchronisation Top cable entry Top & bottom cable entry Space heaters Panel lighting Ambient temperature maximum +55 C Allowable altitude <4000 m above sea level Protection up to IP52 Air filters at air inlet Other colours Bypass isolation transformer Bypass stabilizer with isolation transformer Additional analogue meters 96x96, cl. 1.5: Set with VM DC, AM Bat & output FM, VM & AM with select switch Set with Input VM & AM with select switch kW of output Power factor Relay board A077, 16 failsafe NO/NC contacts: Rectifier mains fault Earth fault DC Inverter fuse blown DC out of tolerance 5x options Bypass mains fault Rectifier fuse blown Overtemperature Power supply unit fault Battery discharged Fan failure Relay board A078, 16 failsafe NO/NC contacts: EA inhibited Battery disconnected Inverter ON EN inhibited Battery operation Boost charge Manual Bypass ON Rectifier failure Rectifier ON Asynchronous EA ON External horn Inverter fault EN ON Overload Inverter/Bypass Additional options are available on request

Battery Voltage & UPS Ratings


Voltage (VDC) 110 10 15 20 30 40 60 80 125 10 15 20 30 40 60 80 220 10 15 20 30 40 60 80 100 120 160 400 120 160 220 350 500 750

Higher ratings and other voltages on request Standards Single UPS UPS output voltage 3x400 / 230V Rectifier input voltage 3x400V +10/-10% Bypass input voltage 3x400/230V +10/-10% Frequency 50Hz +/-6% 6 - pulse Rectifier with Isolation Transformer Rectifier standard size, for UPS AC load with PF 0.8 and up to 1h Battery autonomy Rectifier input switch Fixed charging voltage IU characteristic Power - Module for nominal rating Static switch EN (mains side) with additional backfeed protection System front panel with additional LEDs for direct alarm display LCD display unit with keyboard Alarm relays: Battery operation NO/NC Common alarm 2 x NO/NC Battery capacity test ( full discharge with actual load ) Bottom cable entry Earth terminal N+1 monitored two-speed fans Ambient temperature range from -10 to +40 C Protection IP20 Painting pebble grey, RAL 7032 structured * within type range

UPS Rating (kVA)

Man-Machine Interface (Front Panel)


The front panel which is identical for both AC and DC Systems facilitates a comprehensive and flexible man-machine interface. It is divided into four sections: The system panel shows the systems current operation status, meaning which system part is supplying the load at the moment and which is in stand-by mode. LEDs also indicate possible faults. Operations for turning on and off the system and a lamp test button for checking if all LED indications function properly. The display unit consist of a LC display, an alarm LED, an acoustic alarm and a key-pad. With this the user can set following operational parameters, obtain a list of measurement data, and get access to the event and alarm log. On the alarm indication panel the respective LED lights up, after an alarm has occurred.

Operational parameters

Selectable second display language Autostart Bypass operation Boost charge Auto boost (charge) Battery capacity test Battery monitor test (optional) Set date / time Load in % of nominal kVA rating AC rectifier mains 1 voltage and current AC bypass mains 2 voltage DC total current, battery voltage and current Battery temperature (with optional sensor) AC Inverter current AC output voltage, current and frequency AC output peak current Time left in battery operation with actual load (optional with programmed battery data) Event log with date and time (change in operating mode and alarm)

Measurements

GUTOR Electronic LLC Hardstrasse 74 I 5430 Wettingen / Switzerland P +41 (0)56 437 34 34 I F +41 (0)56 437 34 44 gutor.info@apcc.com I www.gutor.com Offices: Brazil I Canada I China I Germany I India Japan I Malaysia I Mexico I Russia I Saudi Arabia United Arab Emirates I USA