You are on page 1of 2

hegman grind gauge.finest of grind gauge Measure degree of dispersion(size particle) Clean the equipment.

fill the sample into the groove.drawn the paint with the scapper bar.observeron change colour of gloss and matt in 3mm range .look at the scale and note the reading. Reading on 3mm between gloss and matt. -result will effect on milling process due to size particle on paint for gloss. Convertional Slow application due to fluid delivery Low air pressure 75psi Delivery pressure greater than 20 psi Need special pain container Gun can be unwidely two line to to supply the gun . Basic equipment. Easy to clean airless excellent application rate can need 100 psi to operate the pump use manifacture container single line supply pressure paint need more maintainance equipment need flushing well.expensive

Holiday /pin detector test.9-90v Dft less 300 9v.dft 300-500um 90 or 671/2 v Hi volt 15 kv Thermo plastc-matariel soften with application of heat are linear polymer and thefore reversible or non convertible Thermosetting material will cure wit application of heat .convertible or non reversible material like epoxy and urethane. Solvent-will dissolvd another material Solute is dissolved in solvent Solution the resul of above. Dispersion-a solid or liquid with in another liquid where thess no solubility Suspention-fine particular solid dispersed within a liquid .no solubility Emulsion-a liquid dispersed within another liquid whwre there is no solubility. Flash point.-a temp at which vapour from solvent will ignite if present of spark Abel cup.blue flame appeared Opaque-inert particles ligh scattering properties in oder to give covering powet opacity and colour Opacity-test to determine ability to hide the substrate.trough test/black andwhite fused plate Footner duplex process-after pickling imemersed into bath of prosphoric or chomic acid solution for 1-2 min.with iron filling.rinse in clean water and check for ph..readind 4.5-7 phthis process to passive the substrate. Pickling-chemical removal of oxides(rust)

Potassium Ferricyanide salt test The Blue colouring shows the presence of Fe (Iron) Salt contamination. The Copper Sulphate Test-millscale test

Ford flow cup-Clean the equipment.LEVEL THE STAND & CUP. PLACE finger UNDER THE FLOW CUP 4mm nozzleTO CATCH THE PAINT. FILL THE CUP WITH PAINT ENSURING IT IS FULL WHILST COVERING THE 4mm HOLE IN THE BOTTOM. RUN A STRAIGHT EDGE OVER THE LIP OF THE CUP TO ENSURE IT IS FULL. SIMULTANEOUSLY REMOVE FINGER FROM BOTTOM AND START STOP WATCH. TIME UNTIL 1ST BREAK IN FLOW. THE TIME RECORDED IS THE VISCOSITY IN SECONDS AT THE TEMPERATURE.

You might also like