You are on page 1of 21

POWER TRANSFORMER POWER TRANSFORMER

HYUNDAI

1. Production Capacity

1) Annual production capacity 2) Production capacity 3) Production voltage 4) Factory Space 5) Manpower for Transformer factory

: 36,200MVA : up to 800MVA (3 phase) : up to 765kV : 61,000

70 Engineers 10 Development Engineers

28 Test Engineers 390 Workers

ELECTRO ELECTRIC SYSTEMS

2. Production Range

1) Power transformer 2) Distribution transformer 3) Cast resin transformer 4) Special purpose transformer

Reactor Furnace transformer Rectifier transformer

Dry type transformer Mobile transformer

ELECTRO ELECTRIC SYSTEMS

3. Quality Assurance (ISO 9001)

1) Original Certification date

: April of 1992

2) The registration covers the design, manufacturing, testing, installation and servicing of

Power and Distribution transformers Cast resin and Dry type transformers Special purpose transformers Reactors

ELECTRO ELECTRIC SYSTEMS

4. Applicable Standard

1) IEC 60076 2) ANSI C57.12.00 3) CAN/CSA-C88-M90 4) AS 2374 5) ES 140

(For Europe and Asia) (For America) (For Canada) (For Australia) (For Korea)

ELECTRO ELECTRIC SYSTEMS

5. Short Circuit Test 1) Performance record of short circuit test


NO. 1 2 3 4 5 6 Specification of Transformer Power Transformer 31PH 15/20MVA 154/23/6.6kV Ynyn0(d) Generating Transformer 3PH 64/85/106/119MVA 230/14.8kV YNd1 Power Transformer 3PH 45/60MVA 154/23kV YNyno(d) Power Transformer 3PH 35/44MVA 154/23kV YNd1 Distribution Transformer 3PH 10MVA 22/6.6kV YNynod(d) Power Transformer 3PH 20/26MVA 132/11.5kV Dyn11 Test Date Apr. 1997 Sept. 1995 Nov. 1989 Nov. 1986 Dec. 1986 Oct. 1985 Type of Tap changer O.L.T.C N.L.T.C O.L.T.C O.L.T.C O.L.T.C O.L.T.C Customer KEPCO in Korea PUD in USA KEPCO in Korea Inchon Iron & Steel in Korea PUB in Singapore WAPDA in Pakistan

ELECTRO ELECTRIC SYSTEMS

2) Tested by Korea Electro-technology Research Institute.

3) Details of PUD transformer


Customer : Public Utility District No.1 of Chelan County in U.S.A Project : Replacement for Rocky Reach Dam TR. Transformer Rating

3phase 60Hz 119MVA 14.8/230kV Step-up Transformer Basic impulse level of HV : 900kV Standard : ANSI C57.12.00

ELECTRO ELECTRIC SYSTEMS

4) Picture of Short circuit test

ELECTRO ELECTRIC SYSTEMS

6. Development of Transformer

1) 765kV Transformer

1PH 60Hz 2333.3MVA 765/345kV OLTC type Auto transformer (Bil : 2050kV)

: 1998

1PH 60Hz 204MVA 20.9/765kV NLTC type Step-up transformer (Bil : 2050kV) : 1999 1PH 60Hz 370MVA 765/345/23kV NLTC type Auto transformer (Bil : 2050kV) : 1999

ELECTRO ELECTRIC SYSTEMS

765kV 370MVA Auto Transformer under test

ELECTRO ELECTRIC SYSTEMS

10

2) Gas Insulated Transformer 1PH 60Hz 20MVA 154/23kV OLTC type (1999)

ELECTRO ELECTRIC SYSTEMS

11

3) 154kV Mobile Transformer (H Class insulation) 3PH 60Hz 40MVA 154/23kV Weight : 40 Ton, Size(m) : L8.6 x W2.9 x H3.9

ELECTRO ELECTRIC SYSTEMS

12

7. Major Customer And Performances 1) North America (1)


Country Customer
Alumnium Company of America Los Angeles Department of Water and Power Chelan County Black & Veatch General Electric Company Baltimore Gas & Electric U.S.A Transmission Agency of Northern California Georgia Power Siemens Westinghouse Power Corp. Southern California Edison Colorado River Commission of Nevada Sacramento Municipal Utility District Duke Fluor Daniel

Rating of Transformer
161/13.8kV, 93MVA 230/70kV, 360MVA 230/14.8kV, 119MVA 345/22kV, 417MVA 138/13.8kV, 125MVA 69/13.8kV, 90MVA 525/230kV, 367MVA 500/18/18kV, 390MVA 500/16kV, 260MVA 225/70.5kV, 250MVA 230/69kV, 200MVA 230/69/13.8kV, 200MVA 356/18kV, 292MVA

ELECTRO ELECTRIC SYSTEMS

13

1) North America (2)


Country Customer
Babcock & Wilcox Engineering Lower Colorado River Authority Puget Sound Energy U.S.A City of Tacoma National Electrical System Inc. New York Power Authority Parsons Energy & Chemicals British Columbia Hydro & Power Authority Richmond Hill Hydro Manitoba Hydro Power Canada Alberta Power Ltd. Stone & Webster Canada Ltd. Transalta Utilities Agra Monenco/Aurora Mine ATCO Power

Rating of Transformer
138/15.5kV, 160MVA 138/22.8kV, 490MVA 230/117.8kV, 325MVA 115/13.8kV, 56MVA 115/13.2kV, 115MVA 230/13.2kV, 86MVA 230/18kV, 262MVA 512.5/242/25.2kV, 500MVA 212.5/228kV, 125MVA 230/115/13.8kV, 250MVA 144/25kV, 50MVA 243/213.8kV, 171MVA 260/72kV, 224MVA 260/72kV, 116.2MVA 260/26.5/13.2kV 150MVA

ELECTRO ELECTRIC SYSTEMS

14

8. Major Manufacturing & Testing Equipment 1) Step-lap cut-to-length M/C 501200(W) 5000(L) ............. 2 80 640(W) 3600(L) .............. 1 3) Overhead Crane 120Ton, 22.5m(H) ........ 2 100Ton, 10.1m(H) ........ 1 80Ton, 10.1m(H) ......... 1 4) Testing capacity Basic impulse level : 4800kV Power frequency test : 700kV

2) Vapour phased autoclave 15000(L)4800(W)7000(H) ...... 1 12500(L)4500(W)6200(H) ...... 1 10000(L)6000(W)6300(H) ...... 1 8000(L)4200(W)5200(H) .... 1 8000(L)4000(W)5400(H) .... 1

ELECTRO ELECTRIC SYSTEMS

15

New Transformer Factory 1. Outline 1) Start to build 2) Completion date 3) Factory size : October of 1998 : August of 1999 : L130W40H35 (m)

2. Production Capability of New Factory 1) Annual Production Capability : 8,200MVA (Total 36,200MVA) 2) Production Capability : Up to 800MVA 3) Production Voltage : Up to 765kV (BIL : 2050kV) 3. Major Manufacturing & Testing Equipment 1) Vapour phased autoclave : L13000W5000H7000 2) Overhead crane 300Ton, 22m 30Ton, 15m 3) Testing capability Basic impulse level : 4000kV (Haefely/Switzerland) Power Frequency test : 1000kV (High volt/Germany)
ELECTRO ELECTRIC SYSTEMS
16

9.1 500kV Transformer 1) Customer : British Columbia Hydro in Canada

2) Year of delivery : 1994 3) Auto Transformer Specification (2 sets)

Rating Rated Voltage BIL Test Voltage Total / transportation Overall dimension

: 3PH 304/340/500MVA, OA/FOA/FOA : 515/242/25.2kV : 1550/850/150kV : 360Ton / 222Ton : L19 W7 H11 (m) : L12.8 W3.6 H4.5 (m)

Transportation dimension

ELECTRO ELECTRIC SYSTEMS

17

500kV Transformer for BCHP of Canada

ELECTRO ELECTRIC SYSTEMS

18

9.2 765kV Transformer 1) Customer : Korea Electric Power Corporation (Dang-Jin TPP) 2) Commercial Operation : June, 2000 3) Generator Step-up Transformer (7 sets)

Rating Rated Voltage BIL Test Voltage Total / transportation Overall dimension

: 3 x 1PH 204MVA, FOA, NLTC : 20.9/765kV : 150/2050kV : 250Ton / 170Ton : L8.8 W6.2 H11.8 (m) : L6.0 W4.7 H5.5 (m)

Transportation dimension

ELECTRO ELECTRIC SYSTEMS

19

4) 765 345kV Tie Transformer (4 sets)

Rating Rated Voltage BIL Test Voltage Total / transportation Overall dimension

: 3 x 1PH 370MVA, FOA, NLTC : 765/345/23kV : 2050/1050/150kV : 290Ton / 190Ton : L9.7 W8.2 H6.9 (m) : L8.8 W4.3 H4.9 (m)

Transportation dimension

ELECTRO ELECTRIC SYSTEMS

20

765kV Generator Step-up Transformer

ELECTRO ELECTRIC SYSTEMS

21

You might also like