You are on page 1of 2

CERT

EN ISO 9001
no. 16 100 0254

DUCTED SPLIT

STANDARD FEATURES
Introduction
The AICOOL CU/FD air cooled ducted split air conditioner is special engineered to match latest requirements in medium
commercial and light industrial application. These new series offer a generous a wide range of cooling capacity from 30 up to
750 MBH.
Using high quality components with international standard ISO, CE, GS, TUV, UL etc., CU/FD new series ensure a reliable
heavy duty better efficiency unit in it's class. Compactness, modular design, easy access for installation and maintenance,
heavy gauge generous material are the based characters of the its superior design.
The CFU/FD series are designed in simple modular form. Multiple outdoor units of bigger capacity give the flexibility in
installation and maintenance. The compact design of the indoor and outdoor units optimize space for shipment and require
only minimal installation space.
Performance
Easy Maintenance

30.000 Btu/hr ...


750.000 Btu/hr

Cabinet
Compressor

The cooling capacity is rated according to ARI standard, using R22 - refrigerant.
The service-oriented design concept provides easy access to the components, by removing the
front panel.
The cabinet is made of heavy gauge galvanized steel, powder coating finished, providing
optimum corrosion resistance.
Fully sealed hermetic scroll compressor with suction gas cooled motor windings, is single
powered up to 15 HP, internal thermal protected, optimized for high tropical ambient, provides
the units high EER.

Air Cooled Condenser


Air standard condenser coils have a generous 12 fpi, large enough to prevent from dust blocking of the fins, easy to clean,
are made of inner grooved seamless copper tube arranged in staggered pattern, mechanically expanded into aluminium
fins, leakage tested by 35 bars.
Dual speed 3 phase high efficiency external rotor condenser axial fan, well known for best quality, low noise level, energy
saving and superior robust design, high ambient resistance up to 60 C, IP 54 motor thermal protected and insulated class F
(DIN EN 60 034-1)
Indoor Units
All standard evaporator coils are designed with such large face area, to prevent from carry over of condensation water into
the air duct system, made of inner grooved seamless copper tube arranged in staggered pattern, mechanically expanded
into aluminium fins, leakage tested by 35 bars. Drain pan is double skinned insulated of 10 mm thick PE foam with
0.12 gr/mm3 density.
Thermal expansion valves are essential for stabile operation even in changing conditions and part load.
AII FD up to 600 MBH supplied with forward curve centrifugal direct driven fans, no need readjustment, therefore applicable
for clean roam applicatin. The indoor fans provide sufficient external static pressure at minimal energy consumption.

ADE IN

FD

Air Filter

R22, R134a, R407C

Electrical circuit

DO

BEST
PERFORMANCE

I
NES

Refrigerant circuit

High performance filter media about durable thermal bonded filters (100% polyesther), free of
silicon, can be cleaned by beating or washing.
The outdoor and indoor units are factory N2 pre-charged, pressure tested and includes an initial
oil charge. Single refrigerant circuit designs up to 150 MBH capacity. High and Low Pressure
Switch supplied. Flare connection for suction pipe and valve for liquid pipe.
Electrical panel supplied with overload, delay starter, phase failure and room thermostat, easy
wiring.

OPTIONAL FEATURES
! Higher grade air filter up to H15 class (Hepa filter)
! Higher external static pressure
! Epoxy coated aluminum fins or copper fins.
! Double skinned with up to 50 mm PE insulation.

! Suction and discharge pressure gauge, filter dryer, sight glass


and liquid valve.

! Stepless fan speed controller, compressor inverter


technology

! Other refrigerant, R134a, R507c, R404a on request.

Every Cooling Solution... We Have It

AICOOL

reserves the right to change in specifications without prior notice

SPECIFICATION DATA
DUCTED SPLIT AIR CONDITIONING UNIT
CU 252

CU 302

FD 202
FD 252
200,000
250,000
16.7
20.8
R22
Thermostatic Expansion Valve
380 Volt / 3 Phase / 50 Hertz
3/4
5/8
5/8
1 5/8
1 3/8
1 3/8

FD 302
300,000
25.0

CU 252 +
CU 102
FD 352
350,000
29.2

3/4
1 5/8

5/8
1 3/8

Model

Outdoor

CU 32

CU 42

CU 52

CU 62

CU 77

CU 102

CU 127

CU 152

Cooling Capacity

Indoor
Btu/h
TR

FD 32
30,000
2.5

FD 42
40,000
3.3

FD 52
50,000
4.2

FD 62
60,000
5.0

FD 77
75,000
6.3

FD 102
100,000
8.3

FD 127
125,000
10.4

FD 152
150,000
12.5

V/Ph/Hz
Inch
Inch

3/8
5/8

3/8
5/8

1/2
3/4

1/2
7/8

5/8
1 1/8

5/8
1 3/8

5/8
1 3/8

Refrigerant
Refrigerant Control
Power Supply
Pipe Connection

Liquid
Suction

CU 202

FD 402
400,000
33.3

CU 252 +
CU 202
FD 452
450,000
37.5

5/8
1 3/8

5/8
1 3/8

5/8
1 3/8

3/4
1 5/8

5/8
1 3/8

4
40
8.96 (4)

4
45
10.8(2)+8.9(2)
22.9 (2) +
20.7 (2)
145 (2) +
130 (2)

4
50
10.8 (4)

4
60
13.6 (4)

6
75
10.8 (6)

22.9 (4)

30.3 (4)

22,9 (6)

145 (4)

175 (4)

145 (6)

169.1 (2)

183.4 (2)

169.1 (3)

630
2+2

630
2+2

630
2+2+2

0.72 (4)

1.9 (4)

0.72 (6)

1.34 (4)

3.61 (4)

1.34 (6)

2,000 (2)

2,000 (2)

2,000 (3)

1,100 (2)

1,100 (2)

1,100 (3)

1,050 (2)

950 (2)

1,050 (3)

400 (2)

550 (2)

400 (3)

CU 202 (2)

CU 252 (2)

CU 302 (2)

CU 252 (3)

FD 502
500,000
41.7

FD 602
600,000
50.0

FD 752
750,000
62.5

Outdoor Unit
Compressor

Coil

Fan

Dimension

Type
Protection Device
Quantity
Nominal Motor
Power Input

Pcs
HP
kW

1
3
2.7

1
4
3.43

1
5
4.17

1
6
4.96

1
7.5
6.54

Rated Load Ampere

5.7

7.2

8.2

10

12.1

Locked Rotor Ampere

40

48

61.8

65.5

98

Face Area

m2

18.2

23.6

35.4

42.5

47.3

71

82.6

Type
Diameter
Quantity

mm
Pcs

500
1

500
1

500
2

500
2

630
1

630
1

630
1

Power Input

kW

0.4

0.4

0.8

0.8

0.72

0.72

1.35

1.9

1.9

Rated Load Ampere

0.94

0.94

1.88

1.88

1.4

1.4

2.2

3.2

Width

mm

896

896

896

960

1,200

1,200

1,200

Length

mm

330

330

330

375

600

600

Height

mm

705

705

1,105

1,218

950

kg

105

110

143

167

187

m2

16.5

16.5

27.1

1,100
1,870
0.3
80
225
1
0.25
0.95
900
650
510
258 x246
800 x370
67

1,100
1,870
0.3
80
225
1
0.37
0.98
900
650
510
258 x246
800 x370
70

1,900
3,230
0.4
110
250
1
0.55
1.55
1,350
700
510
321 x273
1250 x370
88

Material

Weight

Hermetic Scroll
Phase Protector, Thermal Overload Relay, High and Low Pressure Control
1
1
1
2
2
2
3
10
12.5
15
20
25
30
35
8.96
10.8
13.62
8.96 (2)
10.8 (2)
13.6 (2) 10.8 (2) + 8.9
22.9 (2) +
20.7
22.9
30.3
20.7 (2)
22.9 (2)
30.3 (2)
20.7
145 (2) +
130
145
175
130 (2)
145 (2)
175 (2)
130
Aluminum Fins on Inner Grooved Copper Tubes
105.5

151.4

20.7 (4)
130 (4)

169.1

183.4

169.1 + 71

151.4 (2)

Axial Fan with External Rotor Motor


630
630
630
1
1
2

630
2

630
2+1

630
1+1

0.72 (2)

1.9 (2)

0.72 (3)

1.9 (2)

3.61

1.34 (2)

3.61 (2)

1.34 (3)

3.61 (2)

1,170

1,170

2,000

2,000

600

1,100

1,100

1,100

1,100

950

1,050

950

950

1,050

950

205

220

286

330

400

550

2,000
1,200
1,100
600
1,050
950
400 + 205

148.6

173.4

9,000
15,300
1.2
300
400
2
1.8 (2)
5.02 (2)
2,400
1,065
950
1400 x375
2300 x790
349

10,600
18,020
1.2
300
500
1
4
8.36
2,200
1,250
1,140
638 x638
2100 x895
389

1,170 (2)
1,100 (2)
950 (2)
330 (2)

169.1 +
151.4
630
2+2
0.72 (2) +
1.9
1.34 (2) +
3.61
2,000
1,170
1,100
1,100
1,050
950
400 + 330

Indoor Unit

Fan

Material
Face Area
Type
Airflow
External Static Pressure

Dimension

Duct Connection
Weight

Diameter
Quantity
Power Input
Rated Load Ampere
Width
Length
Height
Supply
Return

CFM
CMH
in WG
Pa
mm
Pcs
kW
A
mm
mm
mm
mm
mm
kg

Aluminum Fins on Inner Grooved Copper Tubes


31.8
39.8
53.1
63.7
106.2
127.4
Direct Driven - Forward Curved Centrifugal Fan
1,900
2,100
2,700
3,900
5,050
7,060
7,650
3,230
3,570
4,590
6,630
8,585
12,002
13,005
0.4
0.8
0.8
0.6
1.2
1.2
1.2
110
200
200
150
300
300
300
250
280
315
315
355
355
355
1
1
1
1
1
2
2
0.55
0.8
1.1
1.5
1.8
1.1 (2)
1.5 (2)
1.73
2.13
3.18
4.19
4.92
3.18 (2)
4.19 (2)
1,350
1,400
1,400
1,700
1,700
2,200
2,200
700
830
950
1,030
1,030
1,030
1,065
510
590
635
730
730
750
850
321 x273
300 x305
338 x338
400 x338
431 x375
1300 x338
1400 x375
1250 x370
1300 x440
1300 x495
1600 x570
1600 x570
2100 x590
2100 x700
92
116
146
180
185
254
302
27.1

* Nominal Cooling Capacity Conditions: Evaporator Air Inlet Temp. 26.6C / 55%; Evap. Temp. 7.2 C and Cond. Temp. 50 C
We improve our products continuously, therefore we reserve the right to make modifications without prior notice.

198.2
217
244.2
289.4
Belt Driven - Forward Curved Centrifugal Fan
12,300
12,300
12,300
13,500
20,910
20,910
20,910
22,950
1.6
1.6
1.6
1.4
400
400
400
350
500
500
500
560
1
1
1
1
5.5
7.5
7.5
11
12.1
15.6
15.6
21.8
2,400
2,400
2,400
2,400
1,400
1,400
1,400
1,400
1,240
1,390
1,390
1,390
638 x638
638 x638
638 x638
715 x715
2300 x980 2300 x1080 2300 x1080 2300 x1080
437
463
509
580

361.7
17,600
29,920
1.6
400
630
1
15
29.3
2,600
1,800
1,540
801 x801
2400 x1280
683