Merlin Gerin Miniature circuit-breakers and earth leakage circuit-breakers (MCBs/ELCBs)

contents

page Miniature circuit-breakers C60a C60N C60H C60N UL489 - DC circuit breaker DC circuit breaker - application guide C120N C120H NC100L NC100LH electrical auxiliaries C60, C120 electrical auxiliaries NC100 RCCB / ELCB instantaneous RCCB/ELCB, selective RCCB/ELCB electrical auxiliaries RCCB/ELCB Technical information discrimination cascading dimensions Mini pragma din kit semi-equipped consumer unit 2 3 4 5 8 9 13 17 19 21 22 24 26 28 30 31 32

Merlin Gerin

circuit protection

C60a Miniature circuit-breakers


B and C tripping curves IEC 898: 4500 , IEC 947-2: 5kA
type 1P
1

width in mod. of 9 mm 2

rat (A) 6 10 16 20 25 32 40

Cat No. B curve 23555 23556 23557 23559 23560 23561 23562

B and C curves
C curve 23849 23850 23851 23852 23853 23854 23855

Application control and protection of circuits against overloads and short-circuits. c in domestic installation; c in commercial and industrial electrical distribution systems. Technical data c current rating: 6 to 40A; c voltage rating: 230-400 V AC; c breaking capacity: v Icn ultimate breaking capacity (O-CO cycle):
rat. type (A) to IEC 898 6 to 40 1P 2, 3P voltage (V) 230-240 400-415 breaking capacity (A) 4500 4500

1 protected pole 23849 2P


1 3

6 10 16 20 25 32 40

23571 23572 23573 23574 23575 23577 23578

23863 23864 23865 23866 23867 23868 23869

2 4

v Icn = Icn = 4.5 kA, v Icn ultimate breaking capacity (O-CO cycle):
rat. type (A) to IEC 947-2 6 to 40 1P voltage (V) 130 230-240 400-415 230-240 400-415 440 breaking capacity (A) 10000 5000 3000 10000 5000 3000

2 protected poles

23863 3P
1 3 5

6 10 16 20 25 32 40

23586 23587 23589 23590 23591 23592 23593

23877 23878 23880 23881 23882 23885 23886

2, 3P

2 4 6

3 protected poles

23877

c fast closing contacts; c number of operating cycles (O-C); 20000; c tripping characteristics: v B curve: the magnetic releases operate between 3 and 5 In; v C curve: the magnetic releases operate between 5 and 10 In; c impulse withstand voltage (U imp.): 6 kV; c tropicalization: treatment 2 (relative humidity 95 % at 55 C); c weight (g):
type 1P 110 2P 220 3P 340

c connections: tunnel terminals for rigid cables up to: v 25 mm2 for rating < 25A, v 35 mm2 for rating 32 to 40 A; c installation: in all enclosures designed for Multi 9 equipment.

additional information

electrical auxiliaries: page 21 dimensions: page 31

Merlin Gerin

circuit protection

C60N Miniature circuit-breakers


B, C and D tripping curves IEC 898: 6000 , IEC 947-2: 10kA
width in mod. rat Cat No. of 9 mm (A) B curve 1P 2 1 24045 2 24046 1 3 24047 4 24048 6 24049 10 24050 16 24051 2 20 24052 25 24053 1 protected pole 32 24054 40 24055 50 24056 63 24057 2P 4 1 24071 2 24072 1 3 3 24073 4 24074 6 24075 10 24076 16 24077 20 24078 2 4 25 24079 2 protected poles 32 24080 40 24081 50 24082 63 24083 3P 6 1 24084 2 24085 1 3 5 3 24086 4 24087 6 24088 10 24089 16 24090 2 4 6 20 24091 25 24092 3 protected poles 32 24093 40 24094 50 24095 63 24096 4P 8 1 24097 2 24098 1 3 5 7 3 24099 4 24100 6 24101 10 24102 16 24103 20 24104 2 4 6 8 25 24105 3 protected poles 32 24106 40 24107 50 24108 63 24109 type

B, C and D curves
C curve 24395 24396 24397 24398 24399 24401 24403 24404 24405 24406 24407 24408 24409 24331 24332 24333 24334 24335 24336 24337 24338 24339 24340 24341 24342 24343 24344 24345 24346 24347 24348 24349 24350 24351 24352 24353 24354 24355 24356 24357 24358 24359 24360 24361 24362 24363 24364 24365 24366 24367 24368 24369 D curve 24625 24626 24627 24628 24629 24630 24632 24633 24634 24635 24636 24637 24638 24653 24654 24655 24656 24657 24658 24660 24661 24662 24663 24664 24665 24666 24667 24668 24669 24670 24671 24672 24674 24675 24676 24677 24678 24679 24680 24681 24682 24683 24684 24685 24686 24688 24689 24690 24691 24692 24693 24694

Application control and protection of circuits against overloads and short-circuits. c in domestic installation; c in commercial and industrial electrical distribution systems; c D curve: more particularly adapted for installations with high transient currents (LV/ LV transformers, motors,...). Technical data c current rating: 1 to 63 A; c voltage rating: 230-400 V AC; c breaking capacity: v Icn ultimate breaking capacity (O-CO cycle):
rat. type (A) to IEC 898 1 to 63 1P 2, 3, 4P voltage (V) 230-240 400-415 breaking capacity (A) 6000 6000

24395

v Ics = Icn = 6 kA, v Icn ultimate breaking capacity (O-CO cycle):


rat. type (A) to IEC 947-2 1 to 63 1P voltage (V) 130 230-240 400-415 230-240 400-415 440 breaking capacity (A) 20000 10000 3000 20000 10000 6000

24331

2, 3, 4P

24344

c fast closing contacts; c number of operating cycles (O-C); 20000; c tripping characteristics: v B curve: the magnetic releases operate between 3 and 5 In; v C curve: the magnetic releases operate between 5 and 10 In; v D curve: the magnetic releases operate between 10 and 14 In; c impulse withstand voltage (U imp.): 6 kV; c tropicalization: treatment 2 (relative humidity 95% at 55C); c weight (g):
type 1P 110 2P 220 3P 340 4P 450

24357

c connections: tunnel terminals for rigid cables up to: v 25 mm2 for rating < 25 A, v 35 mm2 for rating 32 to 63 A; c approvals: Marine, (consult us) c installation: in all enclosures designed for Multi 9 equipment.

additional information

electrical auxiliaries: page 21 dimensions: page 31

Merlin Gerin

circuit protection

C60H Miniature circuit-breakers


B, C and D tripping curves IEC 898: 10000 , IEC 947-2: 15kA
width in mod. rat Cat No. of 9 mm (A) B curve 1P 2 0.5 0.75 1 1 2 3 4 6 24643 2 10 24644 16 24646 1 protected pole 20 24647 25 24648 32 24649 40 24650 50 24651 63 24652 2P 4 0.5 0.75 1 3 1 2 3 4 6 24725 10 24726 2 4 16 24727 2 protected poles 20 24728 25 24729 32 24730 40 24731 50 24732 63 24733 3P 6 0.5 0.75 1 3 5 1 2 3 4 6 24738 2 4 6 10 24739 16 24740 3 protected poles 20 24741 25 24742 32 24743 40 24744 50 24745 63 24746 4P 8 0.5 0.75 1 3 5 7 1 2 3 4 6 24751 10 24752 2 4 6 8 16 24753 4 protected poles 20 24754 25 24755 32 24756 40 24757 50 24758 63 24759 type

B, C and D curves
C curve 24900 24901 24968 24969 24970 24971 24972 24973 24974 24975 24976 24977 24978 24979 24980 24902 24903 24981 24982 24983 24984 24985 24986 24987 24988 24989 24990 24991 24992 24993 24906 24907 24994 24995 24996 24997 24998 24999 25000 25001 25002 25003 25004 25005 25006 24908 24909 25007 25008 25009 25010 25011 25012 25013 25014 25015 25016 25017 25018 25019 D curve 25171 25152 25155 25157 25158 25159 25160 25161 25164 25165 25166 25167 25168 25169 25172 25183 25184 25185 25186 25187 25188 25189 25190 25191 25192 25193 25194 25195 25173 25196 25197 25198 25199 25200 25201 25202 25203 25205 25207 25208 25209 25210 25174 25211 25212 25213 25214 25215 25216 25217 25218 25219 25220 25221 25222 25223

Application control and protection of circuits against overloads and short-circuits. c in domestic installation; c in commercial and industrial electrical distribution systems; c D curve: more particularly adapted for installations with high transient currents (LV/ LV transformers, motors,...). Technical data c current rating: 0.5 to 63 A; c voltage rating: 230-400 V AC; c breaking capacity: v Icn ultimate breaking capacity (O-CO cycle):
rat. type (A) to IEC 898 1 to 63 1P 2, 3, 4P voltage (V) 230-240 400-415 breaking capacity (A) 1000 1000

24900

v Ics = 75% of Icn, v Icu ultimate breaking capacity (O-CO cycle):


rat. type (A) to IEC 947-2 1 to 63 1P voltage (V) 130 240 415 240 415 440 breaking capacity (A) 30000 15000 4000 30000 15000 10000

24902

2, 3, 4P

24906

c positive contact indication; c fast closing contacts; c number of operating cycles (O-C); 20000; c tripping characteristics: v B curve: the magnetic releases operate between 3 and 5 In; v C curve: the magnetic releases operate between 5 and 10 In; v D curve: the magnetic releases operate between 10 and 14 In; c impulse withstand voltage (U imp.): 6 kV; c tropicalization: treatment 2 (relative humidity 95% at 55C); c weight (g):
type 1P 110 2P 220 3P 340 4P 450

c connections: tunnel terminals for rigid cables up to: v 25 mm2 for rating < 25 A, v 35 mm2 for rating 32 to 63 A; c approvals: Marine, (consult us) c installation: in all enclosures designed for Multi 9 equipment.

24908

additional information

electrical auxiliaries: page 21 dimensions: page 31

Merlin Gerin

circuit breakers

C60 N UL 489
CSA 22.2 No 5.1 UL Listed for branch circuit protection DC
Main functions of C60N UL 489 circuit breaker: - protection of circuits against: - short circuit currents - overload currents - control - isolation Various applications: - semi-conductors - electronic machinery - control panel - metal working - telecommunication - food, beverage - packaging - crane - conveyors - pumps and compressors - HACR (Heating, Air conditioning, Refrigeration) - engine generators
Compliance with standards c UL 489 circuit breakers File #E215117 c CSA C22.2 No. 5.1 circuit breakers File #179014 c IEC 60947-2, VDE 0660 c CE Marked Standard features c Power circuit: v voltage rating: 120 up to 240 Vac (delta) v ampere interrupting ratings:
rating (A) number of voltage 77F/25C poles 0.71 in. (18 mm) 0.5-35 1P 2P/3P interrupting rating (kA rms) 120 Vac 240 Vac 240 Vac 415 Vac 440 Vac 65 Vdc 125 Vdc UL 489 / CSA 10 5 10 IEC 60947.2 10 20 10 6 10 10

1P 2P

v fast closing: allows increased withstand of the high inrush currents of some loads v current limiting v trip-free mechanism: contacts cannot be held in the ON position when the circuit breaker is tripped automatically v isolation with position break indication - Green strip on the circuit breaker operating handle indicates that all poles open v number of operating cycles (0-C): - electrical: 10,000 - mechanical: 20,000 c Environment: v tropicalization: treatment 2 (relative humidity: 95% at 131F/55C) v degree of protection: - case: IP40 as per IEC 60529 - terminals: IP20 v temperature: -operation: -22 to 158F (-30 to 70C) - storage: -40 to 176F (-40 to 80C) c Weight (oz./g):
type C60N 1P 3.88/110 2P 7.75/220 3P 11.64/330

Connection The C60N UL 489 is available in box lug/box lug connection

box lug/box lug

058976N

Merlin Gerin

circuit breakers

C60 N UL 489
CSA 22.2 No 5.1 UL Listed for branch circuit protection DC
Connection caracteristics c Box lug UL 486A File #216919: v 0.5-25 A: (#18-#4 AWG) 1-25mm2 cables, torque 22 Ib.in v 30-35 A: (#18-#2 AWG) 1-35mm2 cables, torque 31 Ib.in
058979N

box lug

Adaptable electrical auxiliaries c Remote tripping: v shunt trip (MX + OF) v undervoltage release (MN) c Remote indication: v auxiliary switch (OF) v alarm switch (SD) Time-current curves C curve - Overcurrent protection for all application types: c Ratings: 0.5-35 A set at 77F (25C) c Tripping curve: The magnetic releases operates between 7 and 10 times ampere rating D curve - Overcurrent protection for loads with high inrush currents (motors, transformers etc.): c Ratings: 0.5-35 A set at 77F (25C) c Tripping curve: The magnetic releases operates between 10 and 14 times ampere rating

Merlin Gerin

circuit breakers

C60 N UL 489
CSA 22.2 No 5.1 UL Listed for branch circuit protection DC
Box lug / box lug connection (upstream / downstream)
type width in modules 0.354 in. (9 mm) 2 rating (A) reference C curve D curve

1P

058976N

E27969

2P

058977N

E27970

1 3

2 4

3P

058978N

E27971

1 3 5

2 4 6

0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 20 25 30 35 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 20 25 30 35 1 1.5 2 3 4 5 6 7 8 10 13 15 20 25 30 35

60100 60101 60102 60103 60104 60105 60106 60107 60108 60109 60110 60111 60112 60113 60114 60115 60116 60134 60135 60136 60137 60138 60139 60140 60141 60142 60143 60144 60145 60146 60147 60148 60149 60150 60168 60169 60170 60171 60172 60173 60174 60175 60176 60177 60178 60179 60180 60181 60182 60183

60117 60118 60119 60120 60121 60122 60123 60124 60125 60126 60127 60128 60129 60130 60131 60132 60133 60151 60152 60153 60154 60155 60156 60157 60158 60159 60160 60161 60162 60163 60164 60165 60166 60167 60184 60185 60186 60187 60188 60189 60190 60191 60192 60193 60194 60195 60196 60197 60198 60199

additional information

electrical auxiliaries: page 21 dimensions: page 31

Merlin Gerin

application guide

DC circuit-breakers

selecting the circuit breaker

The selection of type of circuit breaker most suitable for protection of a DC installation depends mainly of the following criteria: c the rated current, which determines the rating of the equipment c the type of system (1,2 or 3) (see below) When a short-circuit occurs at its terminals, a battery discharges a current given by ohms law: IC = Vb Ri where Vb = the maximum discharge voltage (battery 100% charged) and Ri = the internal resistance equivalent to the sum of the cell resistances (figure generally given by the manufacturer in terms of Ampere-hour capacity of the battery). example What is the short-circuit current at the terminals of standing battery with the following characteristics: c capacity: 500 Ah c maximum discharge voltage: 240V (110 cells of 2.2 V) c discharge current: 300 A c autonomy: 30 mm

c the rated voltage, which determines the number of poles to be involved in breaking c the maximum short-circuit current at the point of installation. which determines the breaking capacity

calculation of the short-circuit current (ISC) at the terminals of a battery

c internal resistance: 0.5 m per cell

ISC

Ri = 110 x 0.5 x 10-3 ISC = 240 = 4.4kA 66 x 10-3

As the above calculation shows, the shortcircuit current relatively weak. Note: If the internal resistance is not known, the following aproximate formula can be used: ISC = kC, where C is capacity of the battery expressed in Ampere-hours, and k is a coefficient close to 10 but in any case always lower than 20.

arrangement of breaking poles according to the type of system


system 1 the source has one polarity earthed circuit diagrams and differrent kinds of fault
i + U B b C A R a + U/2 + U/2 b C R B A b C

system 2 the source has a middle point earthed


i a

system 3 the source is isolated from earth


i + U B A R a

analysis of each fault

fault A

fault B fault C the worst case arrangement of breaking poles

maximum ISC: only the positive polarity is involved maximum ISC: both polarities involved no consequences fault A all poles needed for breaking are placed in series on the positive polarity (1), (2) example: U = 250 V, current I = 47 A. If a NC100LS is used, one pole is enough to break 250 V A single pole unit is therefore needed

ISC close to max. ISC: only the positive polarity is involved, at half voltage U/2 maximum ISC: both polarities involved as per fault A, but the polarity is involved fault A and C number of poles necessary to break max. ISC at voltage U/2 should be placed on each polarity example: U = 250 V, current I = 100 A, ISC = 15 kA. Each pole will be subjected to a max. voltage U/2 = 125 V. With a NC100 (breaking cap. = 20 kA), 2 poles are involved in breaking a voltage of 125 V. A four pole NC100 is needed, with 2 poles in series in each polarity
+

no consequences

maximum ISC: both polarities involved no consequences fault B number of poles necessary for breaking should be split between the two polarities example: U = 125 V, current I = 80 A. If a NC100 is used (breaking cap. = 20 kA) 2 poles are involved to break U = 125 V A two pole unit is needed, with one pole on each polarity

+
(1) or negative if the positive polarity earthed. (2) an extra pole will be needed on the earthed polarity to provide isolation

to load

to load

to load

Merlin Gerin

circuit protection

C120N Miniature circuit-breakers


B, C and D curves IEC 898: 10000 - IEC 947-2: 10 kA
function
c protection of cables against overloads and short-circuits in final distribution c manual control and isolation c earth leakage protection when combined with a Vigi C120 module without temperature derating c remote tripping, indication, by adding auxiliaries common to the entire C60/C120 range

description

Technical data c current rating: 63 to 125 A c voltage rating Ue max.: 440 V AC c insulation voltage Ui: 500 V c impulse withstand voltage Uimp: 6 kV c compliance with standard IEC 898: devices accessible by inexperienced persons c breaking capacity: v as in IEC 898
type 1, 2, 3, 4P voltage (V) 230...400 breaking cap. Icn (A) 10000

v as in IEC 947-2 (Icu)


voltage breaking cap. (V) Icu (kA) 1P 130 20 230...240 10 400...415 3 (1) 2, 3, 4P 230...240 20 400...415 10 440 6 (1) breaking capacity under 1 pole with IT isolated neutral system (case of double fault) type

c approval: IMQ c connection: v flexible cables: 1.5 to 35 mm2 v rigid cables: 1 to 50 mm2 v terminals ensure: -degree of protection IP2 -tightening of wide cross-section cables -pull-out withstand of cables -automatic guiding of cable into the correct position c markers: v 4 marker clips next to the upstream terminal v label holder on handle (2P, 3P, 4P) c degree of pollution: 3 (for use in an industrial environment) c degree of protection: v open or surface mounted device: IP2 v in a Pragma or Prisma enclosure: IP4 (IPxxD)

B curve
c magnetic trip units operate between 3 and 5 In c protection of very long cables c protection of networks supplied by generators

c service breaking capacity Ics =75 % Icu c positive break indication c fast closing ensures simultaneous closing of poles c electrical durability: v 63 A: 10000 cycles (O-C) v 80...125 A: 5000 cycles (O-C) c limitation class: 3 c mechanical durability: 20000 cycles (O-C) c bistable fixing pawl: simplifies disassembly c weight (g):
1P 205 2P 410 3P 615 4P 820

C curve
c magnetic trip units operate between 5 and 10 In c protection of standard networks

D curve
c magnetic trip units operate between 10 and 14 In c protection of circuits that supply high inrush current loads: transformers, motors, etc.

Merlin Gerin

circuit protection

C120N Miniature circuit-breakers


B curve IEC 898 : 10000 - IEC 947-2: 10 kA
catalogue numbers
type rating (A) catalogue number width in mod. of 9 mm

B curve C120N
1P 1 63 80 100 125 18340 18341 18342 18343 3 3 3 3

2 18340

2P 1 3

63 80 100 125

18344 18345 18346 18347

6 6 6 6

2 4 18344

3P 1 3 5

63 80 100 125

18348 18349 18350 18351

9 9 9 9

2 4 6 18349

4P 1 3 5 7

63 80 100 125

18352 18353 18354 18355

12 12 12 12

2 4 6 8 18355

additional information
10

electrical auxiliaries: page 21 dimensions: page 31

Merlin Gerin

circuit protection

C120N Miniature circuit-breakers


C curve IEC 898 : 10000 - IEC 947-2: 10 kA
catalogue numbers
type rating (A) catalogue number width in mod. of 9 mm

C curve C120N
1P 1 63 80 100 125 18356 18357 18358 18359 3 3 3 3

2 18356

2P 1 3

63 80 100 125

18360 18361 18362 18363

6 6 6 6

2 4 18360

3P 1 3 5

63 80 100 125

18364 18365 18367 18369

9 9 9 9

2 4 6 18365

4P 1 3 5 7

63 80 100 125

18371 18372 18374 18377

12 12 12 12

2 4 6 8 18377

additional information
Merlin Gerin

electrical auxiliaries: page 21 dimensions: page 31

11

circuit protection

C120N Miniature circuit-breakers


D curve IEC 898 : 10000 - IEC 947-2: 10 kA
catalogue numbers
type rating (A) catalogue number width in mod. of 9 mm

D curve C120N
1P 1 63 80 100 125 18378 18379 18380 18381 3 3 3 3

2 18378

2P 1 3

63 80 100 125

18382 18383 18384 18385

6 6 6 6

2 4 18385

3P 1 3 5

63 80 100 125

18386 18387 18388 18389

9 9 9 9

2 4 6 18389

4P 1 3 5 7

63 80 100 125

18390 18391 18392 18393

12 12 12 12

2 4 6 8

18393

additional information
12

electrical auxiliaries: page 21 dimensions: page 31

Merlin Gerin

circuit protection

C120H Miniature circuit-breakers


B, C and D curves IEC 898 : 15000 - IEC 947-2: 15 kA
function
c protection of cables against overloads and short-circuits in final distribution c manual control and isolation c earth leakage protection when combined with a Vigi C120 module without temperature derating c remote tripping, indication, by adding auxiliaries common to the entire C60/C120 range

description

Technical data c current rating: 10 to 125 A c max. voltage rating Ue: 440 V AC c insulation voltage Ui: 500 V c impulse withstand voltage Uimp: 6 kV c complies with standard IEC 898: devices accessible by unexperienced persons c breaking capacity: v as in IEC 898
type 1, 2, 3, 4P voltage (V) 230...400 breaking cap. Icn (A) 15000

v as in IEC 947-2 (Icu)


voltage breaking cap. (V) Icu (kA) 1P 130 30 230...240 15 400...415 4.5 (1) 2, 3, 4P 230...240 30 400...415 15 440 10 (1) breaking capacity under 1 pole with IT isolated neutral system (case of double fault) type

c approval: IMQ c connection: v flexible cables: 1.5 to 35 mm2 v rigid cables: 1 to 50 mm2 v terminals ensure: -degree of protection IP2 -tightening of wide cross-section cables -pull-out withstand of cables -automatic guiding of cable into the correct position c markers: v 4 marker clips next to the upstream terminal v label holder on handle (2P, 3P, 4P) c degree of pollution: 3 (for use in an industrial environment) c degree of protection: v open or surface mounted device: IP2 v in a Pragma or Prisma enclosure: IP4 (IPxxD)

B curve
c magnetic trip units operate between 3 and 5 In c protection of very long cables c protection of networks supplied by generators

c service breaking capacity Ics =50 % Icu c positive break indication c fast closing ensures simultaneous closing of poles c electrical durability: v 63 A: 10000 cycles (O-C) v 80...125 A : 5000 cycles (O-C) c limitation class: 3 c mechanical durability: 20000 cycles (O-C) c bistable fixing pawl: simplifies disassembly c weight (g):
1P 205 2P 410 3P 615 4P 820

C curve
c magnetic trip units operate between 5 and 10 In c protection of standard networks

D curve
c magnetic trip units operate between 10 and 14 In c protection of circuits that supply high inrush current loads: transformers, motors, etc.

Merlin Gerin

13

circuit protection

C120H Miniature circuit-breakers


B curve IEC 898 : 15000 - IEC 947-2: 15 kA
catalogue numbers
type rating (A) catalogue number width in mod. of 9 mm

B curve C120H
1P 1 10 16 20 25 32 40 50 63 80 100 125 18394 18395 18396 18397 18398 18399 18400 18401 18402 18403 18404 3 3 3 3 3 3 3 3 3 3 3

2 18394

2P 1 3

2 4 18412

10 16 20 25 32 40 50 63 80 100 125

18405 18406 18407 18408 18409 18410 18411 18412 18413 18414 18415

6 6 6 6 6 6 6 6 6 6 6

3P 1 3 5

2 4 6 18424

10 16 20 25 32 40 50 63 80 100 125

18416 18417 18418 18419 18420 18421 18422 18423 18424 18425 18426

9 9 9 9 9 9 9 9 9 9 9

4P 1 3 5 7

2 4 6 8 18437

10 16 20 25 32 40 50 63 80 100 125

18427 18428 18429 18430 18431 18432 18433 18434 18435 18436 18437

12 12 12 12 12 12 12 12 12 12 12

additional information
14

electrical auxiliaries: page 21 dimensions: page 31

Merlin Gerin

circuit protection

C120H Miniature circuit-breakers


C curve IEC 898 : 15000 - IEC 947-2: 15 kA
catalogue numbers
type rating (A) catalogue number width in mod. of 9 mm

C curve C120H
1P 1 10 16 20 25 32 40 50 63 80 100 125 18438 18439 18440 18441 18442 18443 18444 18445 18446 18447 18448 3 3 3 3 3 3 3 3 3 3 3

2 18445

2P 1 3

2 4 18456

10 16 20 25 32 40 50 63 80 100 125

18449 18450 18451 18452 18453 18454 18455 18456 18457 18458 18459

6 6 6 6 6 6 6 6 6 6 6

3P 1 3 5

2 4 6 18468

10 16 20 25 32 40 50 63 80 100 125

18460 18461 18462 18463 18464 18465 18466 18467 18468 18469 18470

9 9 9 9 9 9 9 9 9 9 9

4P 1 3 5 7

2 4 6 8 18481

10 16 20 25 32 40 50 63 80 100 125

18471 18472 18473 18474 18475 18476 18477 18478 18479 18480 18481

12 12 12 12 12 12 12 12 12 12 12

additional information
Merlin Gerin

electrical auxiliaries: page 21 dimensions: page 31

15

circuit protection

C120H Miniature circuit-breakers


D curve IEC 898 : 15000 - IEC 947-2: 15 kA
catalogue numbers
type rating (A) catalogue number width in mod. of 9 mm

D curve C120H
1P 1 10 16 20 25 32 40 50 63 80 100 125 18482 18483 18484 18485 18486 18487 18488 18489 18490 18491 18492 3 3 3 3 3 3 3 3 3 3 3

2 18482

2P 1 3

2 4 18500

10 16 20 25 32 40 50 63 80 100 125

18493 18494 18495 18496 18497 18498 18499 18500 18501 18502 18503

6 6 6 6 6 6 6 6 6 6 6

3P 1 3 5

2 4 6 18514

10 16 20 25 32 40 50 63 80 100 125

18504 18505 18506 18507 18508 18509 18510 18511 18512 18513 18514

9 9 9 9 9 9 9 9 9 9 9

4P 1 3 5 7

2 4 6 8 18525

10 16 20 25 32 40 50 63 80 100 125

18515 18516 18517 18518 18519 18520 18521 18522 18523 18524 18525

12 12 12 12 12 12 12 12 12 12 12

additional information
16

electrical auxiliaries: page 21 dimensions: page 31

Merlin Gerin

circuit protection

NC100L Miniature circuit-breakers


C curve IEC 947-2: 25 kA
functions
The circuit-breakers combine the following functions: - protecting circuits against short-circuit currents, - protecting circuits against overload currents, - control, common technical data c power circuit: v voltage rating: 415 V AC v ratings: 10 to 63 A set at 40 C v breaking capacity: - as in BS 3871 Pt1:
rating (A) type voltage (V) 240 415 240 415 break. cap. (kA) 16 16 10 10

- disconnection, - protecting persons against indirect contact in the TN and IT earthing systems The NC100L circuit-breakers are used in the tertiary sector and industry.

description

c environment: v tropicalisation: treatment 2 (relative humidity 95 % at 55 C) v weight (g):


type 1P 180 2P 360 3P 540 4P 720

1040 1P 2P, 3P, 4P 5063 1P 2P, 3P, 4P

v connection: tunnel terminals for 25 mm2 flexible cables or 35 mm2 rigid cables v identification: each device comes with a label holder on the toggle v installation: in Multi 9 or Prisma enclosures

C curve
use cables supplying standard loads technical data c power circuit: v tripping curve: the magnetic releases operate between 7 and 10 In.

- as in IEC 947-2, Icu ultimate breaking capacity and BS 4752 ( O-CO cycle):
rating (A) type voltage (V) 130 220240 400415 220240 380415 break. cap. Icu (kA) 50 25 6 50 25

1063 1P

2P, 3P, 4P

v fast closing: allows increased withstand of the high inrush currents of some loads v disconnection with positive contact indication: pole opening is indicated by the mechanical indicator (green) on the front face of the device. This indicator shows that all the poles are open. v number of operating cycles (O-C): 20 000

catalogue numbers

type

rating (A)

catalogue number

width in mod. of 9 mm

NC100L C curve
1P

10 16 20 25 32 40 50 63

27621 27622 27623 27624 27625 27626 27627 27628

3 3 3 3 3 3 3 3

27628

2P

1 3

10 16 20 25 32 40 50 63

27632 27633 27634 27635 27636 27637 27638 27639

6 6 6 6 6 6 6 6

2 4

27639

Merlin Gerin

17

circuit protection

NC100L Miniature circuit-breakers


C curve IEC 947-2: 25 kA
catalogue numbers
type rating (A) catalogue. number width in mod. of 9 mm

NC100L C curve (continued)


3P 10 16 20 25 32 40 50 63 27643 27644 27645 27646 27647 27648 27649 27650 9 9 9 9 9 9 9 9

1 3 5

2 4 6

27650 4P 10 16 20 25 32 40 50 63 27654 27655 27656 27657 27658 27659 27660 27661 12 12 12 12 12 12 12 12

1 3 5 7

2 4 6 8

27661

additional information

electrical auxiliaries: page 22 dimensions: page 31

18

Merlin Gerin

circuit protection

NC100LH Miniature circuit-breakers


C curve IEC 947-2: 50 kA
functions
The circuit-breakers combine the following functions: - protecting circuits against short-circuit currents, - protecting circuits against overload currents, - control, common technical data c power circuit: v voltage rating: 415 V AC v ratings: 10 to 63 A set at 40 C v breaking capacity as in IEC 947-2, Icu ultimate breaking capacity and BS 4752 (OCO cycle):
rating (A) type voltage (V) 220230 240 400 415 break. cap. Icu (kA) 50 40 12,5 10 (1)

- disconnection, - protecting persons against indirect contact in the TN and IT earthing systems. The NC100LH circuit-breakers are used in the tertiary sector and industry.

description

c environment: v tropicalisation: treatment 2 (relative humidity 95 % at 55 C) v weight (g):


type 1P 180 2P 360 3P 540 4P 720

1063 1P

v connection: tunnel terminals for 25 mm2 flexible cables or 35 mm2 rigid cables v identification: each device comes with a label holder on the toggle v installation: in Multi 9 or Prisma enclosures

C curve
use cables supplying standard loads technical data c power circuit: v tripping curve: the magnetic releases operate between 7 and 10 In.

220230 100 400 50 415 40 440 30 (1) 1 pole breaking capacity in the IT unearthed neutral system (double fault)

2P, 3P, 4P

v fast closing: allows increased withstand of the high inrush currents of some loads v disconnection with positive contact indication: pole opening is indicated by the mechanical indicator (green) on the front face of the device. This indicator shows that all the poles are open. v number of operating cycles (O-C): 20 000

catalogue numbers

type

rating (A)

cat. no.

width in mod. of 9 mm

NC100LH C curve
1P
1

10 16 20 25 32 40 50 63

27509 27510 27511 27512 27513 27514 27515 27516

3 3 3 3 3 3 3 3

27516 2P

1 3

10 16 20 25 32 40 50 63

27520 27521 27522 27523 27524 27525 27526 27527

6 6 6 6 6 6 6 6

2 4

27527

Merlin Gerin

19

circuit protection

NC100LH Miniature circuit-breakers


C curve IEC 947-2: 50 kA
catalogue numbers
type rating (A) catalogue number width in mod. of 9 mm

NC100LH C curve (continued)


3P
1 3 5

10 16 20 25 32 40 50 63

27531 27532 27533 27534 27535 27536 27537 27538

9 9 9 9 9 9 9 9

2 4 6

27538 4P
1 3 5 7

10 16 20 25 32 40 50 63

27542 27543 27544 27545 27546 27547 27548 27549

12 12 12 12 12 12 12 12

2 4 6 8

27549

additional information

electrical auxiliaries: page 22 dimensions: page 31

20

Merlin Gerin

circuit protection

electrical auxiliaries
for C60, C120
Applications
C60 auxiliaries enable remote tripping or remote indication of the ON/OFF positions of an mcb. They are mounted by clipping on the left hand side of the mcb/rcd. In addition to the above Vigi module can always be assembled on the right hand side of an mcb.

Remote Tripping
OF auxiliary contact
<

SD alarm switch

MX + OF shunt trip
max. 54 mm

MN undervoltage release
>

mcb

MX + OF shunt trip release


type width in mod. of 9 mm voltage cat. No.

c MX + OF shunt trip release: v enables the mcb to be tripped from a remote location, v allows remote indication of the OFF or ON position of the mcb by using the same voltage as the one feeding the shunt rip (terminals 12 and 14), v is equipped with a cut-off switch in series with the coil, v all shunt trip release devices are equipped with a red flag trip indicator; c MN undervoltage release v enables miniature circuit breakers to be tripped either when the voltage drops or by operation of the OFF push button of a remote device tripping between 70 and 35% Un, closing 85% Un, v prevents the mcb from being switched ON again if the undervoltage release supply is not present, c MN s undervoltage release, time delayed: v allows micro breaks 200 ms without effects, v all under voltage release are equipped with a red flag indicator.

MX + OF 2
220-415 V AC 110-130 V DC 48-130 V DC 48V AC 24 V AC and V DC 26946 26946 26947 26948

MX + OF
type width in mod. of 9 mm voltage cat. No.

MX + OF shunt trip release

instantaneous MN 2 time delayed 0.5 s MN 4

24 V AC and V DC 48 V AC 48 V DC 220-240 V AC

26948 26961 26962 26963

Comsumption of releases
type MX voltage (V AC or V DC) 415V AC 200-240 V AC 110-130 V AC 110-130 V DC 48 V AC or V DC 24 V AC or V DC 220-240 V AC 48 V AC 48 V DC 220-240 V AC pickup pickup pickup pickup pickup pickup hold hold hold hold (W or VA) 120 50 200 10 22 120 4.1 4.3 2.0 4.1

26946

MN SD alarm switch
type width in mod. of 9 mm cat. No.

MN

MN s

SD

26927

Remote indication
c SD alarm switch An indicating device which monitors the tripping of an mcb. This device offers the following: v a red flag trip indicator, v ability to reset without closing the mcb, v test function; c OF auxiliary switch v a changeover switch which acts as an indicating or control device to monitor the ON or OFF positions of an mcb; v ability to reset without closing the mcb, c breaking capacity of auxiliary contacts.
voltage (V AC or V DC) 415 V AC 240 V AC 130 V DC 48 V DC 24 V DC breaking capacity (A) 3 6 1 2 6

26927

SD OF auxiliary switch
type width in mod. of 9 mm cat. No.

OF

26924

c connection: screw clamp terminal for 1 cable 2.5mm2 (or 2 x 1.5mm2)


14 12 11

26924

OF

Merlin Gerin

21

circuit protection

electrical auxiliaries
for NC100
functions
Remote tripping and indication of NC100 circuit-breakers.

description

auxiliary combinations

- Mounted to the left of the circuit-breaker (SD and OF). - Mounted to the right of the circuit-breaker (MX + OF and MN).

+
SD fault indicating switch OF auxiliary contact

+
Circuit-breaker

+
MX + OF shunt trip release

or
MN undervoltage release

remote tripping
By means of an MX shunt trip or MN undervoltage release. MX + OF shunt trip release When energised, trips and opens the circuitbreaker with which it is associated: c fitted with a cut-off contact c fitted with an O + F contact that indicates the open or closed position of the circuit-breaker. MN undervoltage release When its supply voltage drops (between 70 and 35%) it trips and opens the circuitbreaker with which it is associated, and prevents reclosing of this circuit-breaker until its supply voltage is restored: c complies with IEC 947-2 and IEC 157-1 standards c use: v emergency stop via push button v safety feature on circuit supplying several machines preventing uncontrolled restarting of the motors. MN s time-delayed undervoltage release Undervoltage release controlling opening of the circuit-breaker with which it is associated. Allows a 0.5 second time delay on a short supply interruption or voltage drop. technical data c consumption of releases
type voltage (V CA or V CC) AC DC AC DC AC DC (W or VA)

remote indication
OF contact c this auxiliary contact installed to the left of the circuit-breaker indicates the open or closed position of the circuit-breaker. SD fault indicating switch c this auxiliary switch installed to the left of the circuit-breaker indicates the tripped on fault position of the circuit-breaker. c visualisation of the fault on the front panel by mechanical indicator lamp. technical data c breaking capacity of the auxiliary switches
voltage (V AC or DC) 415 V 240 V 130 V 48 V 24 V breaking capacity (A) AC AC DC DC DC 3 6 1 2 6

technical data common to the auxiliaries c connection: terminal pads for two 1.5 mm2 cables or one 2.5 mm2 cable.

MX

pick-up 240 pick-up 200 holding 4,1 holding 4,1 holding 4,1 holding 4,1

MN

MN s

22

Merlin Gerin

circuit protection

electrical auxiliaries
for NC100
catalogue numbers
type control voltage (V AC) (V DC) catalogue number width in mod. of 9 mm

MX + OF shunt trip release


220415 110220 2448 110125 2448 27136 27137 27138 2 2 2

C2 C1

12

14

27136

MN undervoltage release
instantaneous
D1 D2 u<

220240

220240

27140

time-delayed s 27140
D1 D2 u<

220240

220240

27143

OF auxiliary contact
27132 1

11

12

14

27132

SD fault indicating switch


27135 1

91

92

94

27135

additional information

dimensions: page 31

Merlin Gerin

23

residual current protection

instantaneous RCCB/ELCB, selective RCCB/ELCB


30 mA to 300 mA instantaneous 300 mA s selective
functions
The residual current circuit breakers combine the following functions: - control - automatic breaking of a circuit if an insulation fault occurs between the phase The residual current release is an electromechanical device operating without any auxiliary source of supply. common technical data c in the presence of devices containing rectifying units (diodes, thyristors, triacs), use an A class instantaneous residual current circuit breaker guaranteeing tripping in the presence of a dc component . c provides protection against nuisance tripping due to transient overvoltages (lightning, switchgear switching on the network, etc.). Level of immunity: 250A peak as in 8/20 ms periodical wave c power circuit: v operational voltage: - 240 415 V AC, +10, -20 %, 50 Hz v operational current: up to 100 A v disconnection with positive contact indication v increased short-circuit current withstand v number of operating cycles (O-C): 20 000 c release: v instantaneous or selective release: fixed sensitivities for all ratings c manual operating mechanism: handle c indication: v mechanical: the residual current fault is shown on the front face by a mechanical indicator v electrical: by the SD indication auxiliary

protected against nuisance tripping


and earth that is greater than or equal to 10,30,300 mA. The residual current circuit breakers are used in the residential, tertiary and industrial sectors. c environment: v tropicalisation: treatment 2 (relative humidity 95% at 55 C) v weight (g)
type 2P 230 4P 450

description

v connection - tunnel terminals for 35 mm2 flexible cables or 50 mm2 for rigid cables c complies with the standards: IEC 1008 and EN 61-008. Rccb 2P 4080 A and 4 P 4063 A are approved by SIRIM.

instantaneous RCCB/ELCB
technical data c instantaneous release

selective RCCB/ELCB s

technical data v selective release allowing total vertical discrimination where the 30 mA residual current devices are placed downstream.

catalogue numbers

type

voltage (V AC)

rating (A)

sensitivity (mA)

catalogue number

width in mod. of 9 mm

ID residual current switches AC class


2P 240 40 30 100 300 30 100 300 300s 30 100 300 30 100 300 300s 16204 16205 16206 16208 16209 16210 16246 16212 16213 16214 16216 16217 16218 16248 4 4 4 4 4 4 4 4 4 4 4 4 4 4

N T R N

63

80
2

100 16206

24

Merlin Gerin

residual current protection

instantaneous RCCB/ELCB, selective RCCB/ELCB


30 mA to 300 mA instantaneous 300 mA s selective
catalogue numbers
type voltage (V AC) rating (A) sensitivity (mA) catalogue number width in mod. of 9 mm

RCCB/ELCB residual current circuit breakers AC class (continued)


4P 415 40 30 100 300 30 100 300 300s 30 300 300s 16254 16255 16256 16258 16259 16260 16265 16261 16263 16266 8 8 8 8 8 8 8 8 8 8

N T R N

63

80
2 4 6

16260

additional information

electrical auxiliaries: page 26 dimensions: page 31

Merlin Gerin

25

residual current protection

electrical auxiliaries
for RCCB/ELCB
functions
These electrical auxiliaries are used for remote indication or tripping of the residual current circuit breakers.

description

auxiliary combinations

They are mounted on the lefthand side of the residual current circuit breaker within a 54 mm width.

+
<

+
max. 54 mm
>

OF auxiliary switch SD fault indicating switch

MX shunt trip release MN undervoltage release

OFS auxiliary switch

residual current circuit breaker

remote tripping
A MX or MN release can be used for this purpose. Tripping is shown by a red indicator on the front face. MX + OF shunt trip release trips and opens its associated circuit-breaker when energised: c equipped with a self-breaking switch c equipped with a switch (terminals 12 and 14) to indicate whether the circuit-breaker is opened or closed when the coil is energised. MN undervoltage release trips and opens its associated circuit-breaker when the supply voltage drops (between 70 and 35%) and prevents reclosing until the supply voltage is restored: c complies with standards IEC 947-2 c use: v push button emergency stop v safety on the supply circuits of several machines by disabling uncontrolled restart of all motors. MN time delayed undervoltage release s This undervoltage release controls the opening of its associated residual current switch. It allows a 0.5 second time delay on short supply interruptions or voltage drops characteristics c consumption of releases
type voltage (V AC or DC) 415 V AC 220...240 V AC 110...130 V AC DC 48 V AC DC 24 V AC DC 220...240 V AC 48 V AC DC 220...240 V AC (W or VA) inrush inrush inrush inrush inrush inrush inrush inrush hold hold hold hold 120 50 200 10 22 22 120 120 4.1 4.3 2,0 4.1

remote indication
OFS switch c use of the OFS switch is compulsory for adding the MN, MX, SD and OF functions. c fixed on the lefthand side of the residual current switch, it indicates whether the switch is open or closed. OF switch c fixed on the lefthand side of the residual current switch, it indicates whether the switch is open or closed. SD fault indicating switch c this auxiliary switch installed to the left of the circuit-breaker indicates the tripped on fault position of the circuit-breaker. c visualisation of the fault on the front panel by mechanical indicator lamp. characteristics c breaking capacity of the auxiliary switches
voltage (V AC or DC) 415 V 240 V 130 V 48 V 24 V breaking capacity (A) AC AC DC DC DC 3 6 1 2 6

common auxiliary characteristics c connection by pad terminals for 2 cables 1.5 mm2 or 1 cable 2.5 mm2. operation simulation A test button on the front face of the OF switches is used to simulate the OF functions without using the residual current circuit breaker.

MX

MN

MNs

26

Merlin Gerin

residual current protection

electrical auxiliaries
for RCCB/ELCB
catalogue numbers
type control voltage (V AC) (V DC) catalogue number width in mod. of 9 mm

MX + OF shunt trip release


220...415 48...130 24 110...130 48 24 26946 26947 26948 2 2 2

MN undervoltage release
26946 instantaneous 220...240 48 48 26960 26961 26962 2 2 2

time delayed s

220...240

26963

26960

OFS auxiliary switch


26923 1

14 12 11

26923

SD fault indicating switch


26927 1

92 94 91

26927

OF auxiliary switch
26924 1

14 12 11

26924

additional information

dimensions: page 31

Merlin Gerin

27

additional information

discrimination

upstream: C60a, N, H, L, C Curve downstream: C60a, N, H, L


upstream downstream C60a, N, H, L C curve In (A) discrimination limit rating Ir (A) (A) 1 2 3 4 6 10 16 20 25 32 C60a, N, H, L C curve 2 3 15 23 4 30 6 45 10 75 16 120 20 150 25 188 32 240 40 300 50 375 63 473

28

Merlin Gerin

additional information

discrimination

upstream: Merlin Gerin multi 9 downstream: Merlin Gerin multi 9


upstream downstream
In (A) rating Ir C60a curve C NS100N/H/L Trip unit TM-D 16 25 0.19 0.3 0.3 NS160N/H/L trip unit TM-D 80 100 T T T T T T T T T T T T T T T T T T T T T T T T T T T 2.5

32 0.4 0.4 0.4

40 0.5 0.5 0.5 0.5

50 0.5 0.5 0.5 0.5

63 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5

80 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63

100 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

125 T T T T T T T T T T T T T T 2.5

160 T T T T T T T T T T T T T T 2.5 2.5 2.5 T T T T T T T T T T T T T T

10
16 20 25 32 40 10 16 20 25 32 40 50 63 63 80 100 16 20 25 32 40 50 63 16 20 25 32 40 50 63

C60N curve C

0.19

0.3 0.3

0.4 0.4 0.4

0.5 0.5 0.5 0.5

0.5 0.5 0.5 0.5

C120N/H curve C NC100L

0.4 0.4

0.5 0.5

0.5 0.5 0.5

0.5 0.5 0.5 0.5 0.5

0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63

NC100LH curve C

0.4 0.4

0.5 0.5

0.5 0.5 0.5

0.5 0.5 0.5 0.5

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

T T T T T T T T T T T T

T T T T T T T T T T T T T T

T T T T T T T T T T T T T T

Using the tables Two circuit breakers offer total discrimination when the corresponding box in the discrimination table is shaded or contains the letter T. When discrimination is partial for the combination, the corresponding box indicates the maximum value of the fault current for which discrimination is provided. For fault currents above this value, the two circuit breakers trip simultaneously.

Merlin Gerin

29

additional information

cascading
230/240 V network
upstream: Merlin Gerin multi 9 downstream: Merlin Gerin multi 9
upstream cb rated breaking capacity kA rms downstream cb C60a C60N C60a 10 C60N 20 C60H 30 C60H 20 C120N 30 NC100L 50 NC100LH 100

rated breaking capacity 20

30 30

20

30 30

50 50

100 100

upstream: Merlin Gerin Compact downstream: Merlin Gerin multi 9


upstream cb rated breaking capacity kA rms downstream cb C60a C60N C120N C120H NS100N 85 NS100H 100 NS100L 150 NS160N 85 NS160H 100 NS160L 150 NS250N 85 NS250H 100 NS250L 100

rated breaking capacity 30 80 80 40 100 100 40 50 70 40 50 70

30 40 40 40

40 60 50 50

40 60 70 70

30 40 40 40

40 60 50 50

40 60 70 70

cascading
400/415 V network
upstream: Merlin Gerin multi 9 downstream: Merlin Gerin multi 9
upstream cb rated breaking capacity kA rms downstream cb C60a C60N C60N 10 C60H 15 C60H 10 C120N 15 NC100L 25 NC100LH 50

rated breaking capacity 10 15 15

10

15 15

25 25

50 50

upstream: Merlin Gerin Compact downstream: Merlin Gerin multi 9


upstream cb rated breaking capacity kA rms downstream cb C60a C60N C120N C120H NS100N 36 NS100H 70 NS100L 150 NS160N 36 NS160H 70 NS160L 150 NS250N 36 NS250H 70 NS250L 150

rated breaking capacity 15 20 20 25 30 30 25 25 25 25 25 25

15 25 25 25

20 30 25 25

20 30 25 25

15 25 25 25

20 30 25 25

20 30 25 25

30

Merlin Gerin

dimensions
multi 9
C60
circuit breakers
4P 3P+N 3P 2P 1P+N 1P

C120
circuit breakers
4P 3P+N 3P 2P 1P

Auxiliaries for C60, C120, ID/RCCB

OF, SD, OF+SD/OF

OF, SD, OF+SD/OF

MX, MN, MN S , MSU

MX+OF, MNx

MX, MN, MN S , MSU, MX+OF, MNx

NC100
circuit breakers
4P 3P 2P 1P

Auxiliaries

RCCB

Auxiliaries

Merlin Gerin

31

MULTI 9 Consumer Unit Mini Pragma Din-Kit Semi-equipped Consumer Unit


Mini Pragma Din-Kit Semi-equipped Consumer Unit comprising :- one enclosure - one incoming fuse-switch / circuit breaker / isolator - one earth leakage circuit breaker ONE complete consumer unit = ONE Mini Pragma Din-Kit plus Outgoing Domae MCBs Ease of selection Robust design for all building requirements Resistant to impacts, scratches, humidity as it is made of insulating, self-extinguishing material (compliant to IEC 529 : IP40 and IEC 695-2-1 casing : 650C / 30s)

Number of Ways (Enclosure) 12

Din-Kit Reference DK12FS33E410

Incoming Rating 32

Contents 12-way Mini Pragma Enclosure X1 SFT 32A 1P+N Fuse Switch X1 Domae ELCB 40A 2P 100mA X1 12-way Mini Pragma Enclosure X1 Domae 1P+N 40A MCB 4.5kA X1 Domae ELCB 40A 2P 100mA X1 12-way Mini Pragma Enclosure X1 Isolator 2P 63A X1 Domae ELCB 40A 2P 100mA X1 12-way Mini Pragma Enclosure X1 Domae 1P+N 63A MCB 4.5kA X1 Domae ELCB 63A 2P 100mA X1 12-way Mini Pragma Enclosure X1 Isolator 2P 63A X1 Domae ELCB 63A 2P 100mA X1 18-way Mini Pragma Enclosure X1 SFT 32A 1P+N Fuse Switch X1 Domae ELCB 40A 2P 100mA X1 18-way Mini Pragma Enclosure X1 2P 40A MCB 4.5kA X1 Domae ELCB 40A 2P 100mA X1 18-way Mini Pragma Enclosure X1 Isolator 2P 63A X1 Domae ELCB 40A 2P 100mA X1 18-way Mini Pragma Enclosure X1 Domae 1P+N 63A MCB 4.5kA X1 Domae ELCB 63A 2P 100mA X1 18-way Mini Pragma Enclosure X1 Isolator 2P 63A X1 Domae ELCB 63A 2P 100mA X1 24-way Mini Pragma Enclosure X1 Domae 1P+N 63A MCB 4.5kA X1 Domae ELCB 63A 2P 100mA X1 24-way Mini Pragma Enclosure X1 Isolator 2P 63A X1 Domae ELCB 63A 2P 100mA X1

Available Ways for Outgoing Domae 1P MCBs 9

12

DK12MA42E410

40

12

DK12IS62E410

40

12

DK12MA62E610

63

12

DK12IS62E610

63

18

DK18FS33E410

32

15

18

DK18MA42E410

40

14

18

DK18IS62E410

40

14

18

DK18MA62E610

63

14

18

DK18IS62E610

63

14

24

DK24MA62E610

63

20

24

DK24IS62E610

63

20

Note : For other combination, please consult us.


32
Merlin Gerin

Merlin Gerin

Mini

Pragma
Din Kit
Take full advantage of Merlin Gerin's experience and know-how. Discover Mini Pragma Din Kit a new range of semi equipped consumer units comprising, in a single catalogue number, of: one enclosure (12 / 18 / 24 / 36-way) one incoming circuit-breaker or isolator one earth leakage circuit breaker You can expect: ease of selection a robust design for all building requirements resistant to impacts, scratches, humidity as it is made of insulating, self-extinguishing material (compliant to IEC 529:IP40 and IEC 695-2-1 casing: 650C / 30s) surface mounted with a sealable front face Merlin Gerin Mini Pragma Din Kit, an offer for everyday comfort!

Semi equipped consumer unit

Schneider Electric Industries (M) Sdn Bhd (378576-M)


Shah Alam (HQ) No. 11, Jalan U1/19, Seksyen U1, Hicom-Glenmarie Industrial Park, Shah Alam 40150, Selangor, Malaysia Tel : (603) 7883 6333 Fax : (603) 7883 6188 Customer Care: 1-800-880-877 Email : care@my.schneider-electric.com Website : www.schneider-electric.com.my Johor Bahru Branch Tel : (607) 351 3801 Fax : (607) 351 4113 Ipoh Branch Tel : (605) 527 1375 Fax : (605) 527 1375 Prai Branch Tel : (604) 398 3981 / 2 Fax : (604) 398 3984 Kota Kinabalu Branch Tel : (6088) 237 012 Fax : (6088) 216 900 Kuching Branch Tel : (6082) 368 428 Fax : (6082) 361 855
As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication.

Design, production, illustrations: Schneider Electric Industries (M) Sdn Bhd Printed in Malaysia

Services Hotline Tel : (603) 7883 6238 (24 Hrs)

SEIMC60C04

12-2007