TOP Refer to Refer to Refer to 422) Refer to Refer to Refer to Refer to Refer to Refer to CPM2C - CIF11 RS422) 2
C200H - LK202V1 C200H/C200HS C200H 201 V1 - LK C500/C1000H/ C500 - LK201 - V1 C2000H/C500 C500 - LK203 C50/C120/C500 - LK201 C120 - V1 /C1000H/C2000 H/C120F/C500F - LK202 C120 - V1 CPM1 - CIF01 CPM1A/CPM2A (block Type) CPM1 - CIF11 CPM2C - CIF01 CPM2C (Card Type)
diagram(RS 422) diagram(RS 232C) diagram(RS -232C/ cable cable cable cable cable cable
diagram(RS 232C) diagram(RS 422) diagram(RS 232C ) diagram(RS 422) diagram( RS232C ) diagram( RS -232C/ ALL TOP
Caution
Be cautious that Communication Unit of C200H/C200HS differs from other in connector pin spec. (Refer connection diagram (2),(4))
(2) RS-232C (SYSMAC-C200 TOP (for 9/15 Pin Connector) This is connection diagram for SYSMAC-C C200. Comm. Link Module(9Pin) 1 2 3 4 5 6 7 8 9 FG SD RD RTS CTS +5V DR ER SG
3
(3) RS-422 (SYSMAC-C TOP (for 5Pin Terminal Block or 15Pin Connector ) This is connection diagram for SYSMAC-C PLCs except C200. Comm. Link Module(9Pin) TOP (5Pin Terminal Block/15pin) 1 2 3 4 5 6 7 8 9 SDB SDA RDB FG SG RDA 1/11 2/12 3/13 4/14 5/15 RDA RDB SDA SDB SG
This is connection diagram for SYSMAC-C PLC C200. Comm. Link Module(9Pin) TOP (5Pin Terminal Block/15Pin) 1 2 3 4 5 6 7 8 9 RDA RDB SDB SDA SG 1/11 2/12 3/13 4/14 5/15 RDA RDB SDA SDB SG
3) Command Level Setting Set by SW4. Recommend 2. Switch 0 1 2 3 4 5 6 7 8 9 A B C Command Level Level 1 available Level 1,2 available Level 1,2,3 available Disable setting Level 1 available Level 1,2 available Level 1,2,3 available Disable setting Level 1 available Level 1,2 available Level 1,2,3 available Disable setting Level 1 available odd even JIS 8bit 1 Stop bit odd Parity even Etc. ASCII 7bit 2 Stop bit
D E F
ON
Terminator Exist
Mode 1:1
None
1:N
REF.
(2) C500-LK201-V1 Dip Switch Setup IO port RS422 RS422 RS232 RS232 8 7 6 5 4 3 SW1 2 1 ON 8 7 6 5 4 SW2 3 2 1 ON Setting Switch Status ON 0 OFF OFF Station Num. Setting OFF OFF OFF Not Used Not Used Power On PLC Mode Baud Rate Run 300 OFF Baud Rate Setting ON OFF ON Not Used Mode Command Level CMD Level setting 1:1 1 OFF OFF 1 ON OFF 1:N 1,2 OFF ON 1,2,3 ON ON 600 ON OFF OFF ON Stop 1200 2400 4800 9600 OFF OFF OFF ON ON ON ON OFF OFF ON ON OFF ON OFF ON OFF 1920 0 OFF OFF ON OFF 1 ON OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF 30 OFF ON ON ON ON 31 ON ON ON ON ON
Sync.
REF.
REF.
(3) C500-LK203 Dip Switch Setting 5V Supply ON OFF In/Out Port RS422 RS232 Sync. Internal External Terminator None Exist CTS 0V External ON ON 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1
SW1
SW2
Setting Item Assign Station Num. 0 OFF OFF Station Num. Setting OFF OFF OFF Parity & Code Transmission Code Parity Power On PLC Mode
Set Switch Status ON 1 ON OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF 30 OFF ON ON ON ON 31 ON ON ON ON ON
Setting Item Assign Baud Rate 300 OFF Baud Rate Setting ON OFF ON Select System Mode Command Level Command Level Setting 1:1 1 OFF OFF
Set Switch Status ON 600 ON OFF OFF ON 1200 OFF OFF OFF ON OFF 2400 4800 9600 ON ON ON OFF 1:N 1 ON OFF 1,2 OFF ON 1,2,3 ON ON OFF ON ON OFF ON OFF ON OFF 1920 0 OFF OFF ON OFF
System#0
System#1
REF.
SW2
ON SW3 12345678
Setting Item Assign Station Num. 0 OFF OFF Station Num. Setting OFF OFF OFF Not Used Not Used Power On PLC Mode Run Assign Baud Rate 300 OFF Baud Rate Setting ON OFF ON Not Used Mode Command Level Command Level Setting 1:1
Set Switch Status ON 1 ON OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF 30 OFF ON ON ON ON 31 ON ON ON ON ON
Stop 600 ON OFF OFF ON 1200 2400 4800 9600 OFF OFF OFF ON ON ON ON OFF OFF ON ON OFF 1:N 1 OFF OFF 1 ON OFF 1,2 OFF ON 1,2,3 ON ON ON OFF ON OFF 1920 0 OFF OFF ON OFF
C120-LK201-V1
Set Switch Status CTS Always ON ON OFF External CTS OFF ON External Sync. OFF ON OFF ON
Sync. Type
Setting Item Terminator Exist ON OFF ON OFF ON OFF Not Used Not Used
Caution
During communication, Mode of PLC must be MONITOR Otherwise, . Writeto PLC is not available. If Data Memory(DM6600) is set to 0101h, PLC Mode is MONITOR . DM6600 is available to be changed in only PROGRAM mode.
11
(5) C200HW -COM06 Setup This is setting for OMRON C200 PLC. Settings use internal DM area. (Refer PLC manual in detail.) Default Settings are RS232C, 9600, 7bit, 2bit, even. Caution During communication, Mode of PLC must be MONITOR Otherwise, . Writeto PLC is not available. This is how to use communication unit for RS-422. Following dip switch is located inner of C200HW -COM06. 2 SW1 SW2 ON RS422/RS485 in case of 2-wire type SW1 : Set 2 SW1 : Set 4 SW2 : Set 1 SW2 : Set ON RS422/RS485 in case of 4-wire type 1 4
In case interfacing to TOP by RS-422, set 4-wire type. (Refer PLC manual for RS-422 settings.)
12
(2) TOP Serial Setup Serial Settings are as follows. ??Serial Baud Rate : Same as controller setting. s ??Serial Data Bit : Same as controller setting. s ??Serial Stop Bit : Same as controller setting. s ??Serial Parity Bit : Same as controller setting. s ??Serial Signal Level : Same as controller setting. s ??Controller Station No. at Comm. Diagnosis(0~31) s : Same as controller setting s
13
TOP
CPM1-CIF01
Refer
to
cable
CPM1-CIF11 CPM2CCIF01
CPM2C CPM2CCIF11
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
14
TOP(5Pin Terminal/15Pin)
1/11 2/12 3/13 4/14 5/15 RDA RDB SDA SDB SG
15
(2) TOP Serial Setup Serial Settings are as follows. ??Serial Baud Rate : Same as controller setting. s ??Serial Data Bit : Same as controller setting. s ??Serial Stop Bit : Same as controller setting. s ??Serial Parity Bit : Same as controller setting. s ??Serial Signal Level : Same as controller setting. s ??Controller Station No. at Comm. Diagnosis(0~31) s : Same as controller setting s
16
50,120(F),500(F) 0~31 0~31 0~127 0~127 Refer following List. None 0~63
200H(S),
0~255 (0~511:200HS)
Input A T C D
(3) SYSMAC CS1 Series Dev Index Register Task Flag(TK) Data Register Timer(CV) Counter(CV) Data Memory Internal AUX. Relay Channel I/O Hold Relay Special Auxiliary Relay Exp. Data Memory(E0~EC) Exp. Data Memory(Current Bank) CV : Current Value Addr IR TK DR T C D W CIO H A E0~EC EM CS1 0~15 0~30 0~15 0~4095 0~4095 00000~32767 0~511 0~6143 0~511 0~959 0~32767 0~32767
18