UYGULAMA 1

24V START
0V

I1.5 I1.4 I1.3 I1.2 I1,1 I1.0 I0.7 I0.6 I0.5 I0.4 I0.3 I0.2 I0.1 I0.0

CPU-224

Q1.1 Q1.0 Q0.7 Q0.6 Q0.5 Q0.4 Q0.3 Q0.2 Q0.1 Q0.0

24V LO

0V

Verilen PLC balantsna gre; START butonuna basldnda Q0.0 kn aktif yapan PLC programn yaznz.

CEVAP 1

UYGULAMA 2

STOP

Verilen PLC balantsna gre; STOP butonuna basldnda Q0.0 kn pasif yapan PLC programn yaznz.

CEVAP 2

UYGULAMA 3

START

Verilen PLC balantsna gre; I0.0 butonuna basldnda Q0.0 kn aktif yapan, I0.1 butonuna basldnda Q0.0 kn pasif yapan PLC programn yaznz.

STOP

CEVAP 3

UYGULAMA 4

S5

S4

S3

S2

S1

S0

L2

L1

LO

Verilen PLC balantsna gre; S0 aktif ve S1 pasif iken Q0.0 k aktif olsun S2 aktif ve S3 pasif iken Q0.1 k aktif olsun S4 aktif ve S6 pasif iken Q0.2 k aktif olsun PLC programn yaznz. (Aktif: Kontan konum deitirmesi Pasif: Kontan konum deitirmemesi)

CEVAP 4

UYGULAMA 5

L5

L4

L3

Verilen PLC balantsna gre; S0,S1 aktif ve S3,S4 pasif iken Q0.0 k aktif olsun S0 aktif ve S2, S3, S4, S5 pasif iken Q0.1 k aktif olsun S0, S1, S2 aktif ve S4 pasif iken Q0.2 k aktif olsun S3, S4, S5 aktif ve S0, S1, S2 pasif iken Q0.3 k aktif olsun S3 aktif ve S1, S2 pasif iken Q0.4 k aktif olsun S4, S1 aktif ve S2, S3 pasif iken Q0.5 k aktif olsun

CEVAP 5

UYGULAMA 6
DEVRE 1 DEVRE 2

Acil durdurma istenilen yerlerde kullanlan rleli kumanda devresi. ki input aktif yapldnda STOP ncelikli alr

Alarm devrelerinde kullanlan rleli kumanda devresi. START ncelikli alr.

Verilen Devre1 ve Devre2deki rleli kumandalarn PLC balantsn iziniz ve gerekli programlar yaznz.

CEVAP 6

START

Devre1 ve Devre2 rleli kumanda balantsnn PLC balant ekline evrilmesi (ikisi birlikte verilmitir)

STOP
L

UYGULAMA 7 Mhrlemenin balayaca bir bitlik adres yazlr Balang adresi dhil mhrlenecek adres adedi Resetlemenin balayaca bir bitlik adres yazlr Balang adresi dhil mhrlenecek adres adedi

S1

S0

Verilen PLC balantsna gre; S0 anahtarna basldnda Q0.0 set eden, S1 anahtarna basldnda Q0.0 reset eden PLC programn yaznz.

CEVAP 7

Program RESET arlkl olarak alr. END komutu okunduktan sonra tekrar batan balar.

UYGULAMA 8

Verilen PLC balantsna ve aada istenilenlere gre PLC programn yaznz: S0 anahtarna basldnda ilk 6 k set olsun (Q0.0 - Q0.1 - - Q0.5) S1 anahtarna basldnda ilk iki k reset olsun (Q0.0 - Q0.1) S2 anahtarna basldnda son k reset olsun (Q0.3 - Q0.4 Q0.5) S3 anahtarna basldnda tm set olan klar resetlensin (Q0.0-Q0.1-Q0.5)

CEVAP 8

UYGULAMA 9

START

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz; START butonuna basldnda L0 yanacak START butonuna baslmadnda L1 yanacak STOP butonuna basldnda L2 yanacak STOP butonuna baslmadnda L3 yanacak START butonuna bir defa basldnda L0 srekli yanacak.

STOP

CEVAP 9

UYGULAMA 10

START

STOP

S1 M2

S2

M1

S 1 I 0.2

S2

I 0.3

LER

GER

M1

M2

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz; START butonuna basldnda M1 motoru hemen alacak ve bant ileri olarak hareket etmeye balayacaktr. Para S1e dokunduunda bant duracak ve ters ynde hareket etmeye balayacaktr. Para S2ye dokunduunda tekrar durup ileri ynde almaya balayacaktr. Stop butonuna basldnda alma duracaktr

CEVAP 10

UYGULAMA 11

START

STOP

S4

S5

S2

S3

S6

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz; Bir fabrikada bir proses iin tane motor almaktadr. Start butonuna basldnda motor ayn anda almaya balayacaktr. Bu motorlarn her biri iin birer tane yedek motor bulunmaktadr. alan A motorlarnn termii attnda yedek B motorlar kendiliinden devreye girmelidir.

S7

M3B

M2B

M1B M3A

M2A

M1A

CEVAP 11

Devre 3

Q2.0

Devre 4

Q2.0

UYGULAMA 12
3~50Hz 380V L1 L2 L3

Yukarda ksa devreli asenkron motorun iki ynde altrlmasna ilikin g devresi verilmitir. Bu devrenin PLC balantsn iziniz ve PLC programn yaznz

CEVAP 12

Bu devrede S0 kuman da dmesi durdurma, F2F motor ar akm rlesi normalde kapal (NK) konta, S1 ve S2 motorun iki ayr ynde altrlmas iin kullanlan kumanda dmeleridir. ekildeki S0 durdurma dmesi ve F2F ar akm rlesinin normalde kapal kontaklar zerinden PLC I0.0 ve I0.1 girilerine balanmas daha gvenilir bir iletme zellii salamak iindir. Ayn amala K1 kontaktr bobini, PLC Q0.0 kna K2 kontaktrnn NK konta zerinden ve K1 kontaktr bobini PLC Q0.1 kna K1 kontaktrnn NK konta zerinden balanr. Bunun nedeni, herhangi bir nedenle K1 ve K2 kontaktrlerinin ayn anda devrede olmasn nlemektedir. Programn yazlmasnda, K1 ve K2 kontaktrlerine ilikin koullar ayr ayr gz nne alnr. K1 kontaktrnn almasna ilikin lojik ifadenin elde edilmesi iin gerekli koullar u ekilde ifade edilebilir: Eer, S0 durdurma dmesine baslmam ve F2F ar akm rlesi uyarlmam (motor ar yklenmemi) ve K2 kontaktr devrede deilse (motor dier ynde almyorsa), S1 balatma dmesine basldnda K1 kontaktr devreye girecek ve S1 dmesi brakldnda da devrede kalacaktr.

Bu PLC program bir sonraki ekildeki gibi de yazlabilir

UYGULAMA 13 ZAMANLAYICILAR 1.Timer On Delay (TON): Girie gelen sinyalle beraber saymaya balar ve giri 1 olduu srece saymaya devam eder. Ayarlanan sre sonunda zamanlayc biti 1 olur. Giri 0a dtnde kta 0 olur. 1ms 10ms 100ms T0, T32, T64, T96 T1-T4, T33-T36, T65-T68, T97-T100 T5-T31, T37-T63, T69-T95, T101-T255

RESETLEME SRES

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz; Start butonuna basldktan 8 sn sonra Q0.0 kn aktif olsun.

START

CEVAP 13

UYGULAMA 14
START

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz; 2 sn aralklarla Q0.0 flar yaptran program

CEVAP 14 Uygulama 14deki PLC programnn iki ekilde yazlmas aada verilmitir.

UYGULAMA 15

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz;

STOP

START

CEVAP 15

UYGULAMA 16

STOP L2 L1

LO

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz; adet lambann 1sn aralklarla flar eklinde yanmasn salayan program

START

CEVAP 16

UYGULAMA 17
FS3 FS2 FS1 START STOP

M2

M1

MO

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz; Yukarda verilen bant dzeneinde; Start butonuna basldnda M! Motoru hemen alacak Herhangi bir anda Stop butonuna basldnda program hemen duracak FS1 para algladktan 2 sn sonra M2 motoru alacak FS2 para algladktan 3 sn sonra M3 motoru alacak FS3 para alglar alglamaz program hemen duracak

CEVAP 17

UYGULAMA 18

Yanda ksa devreli asenkron motora Y/ yol verme g devresi verilmitir. Bir sonraki ekilde ise kontaktrl kontrol devresi verilmitir. Bu devrenin PLC balantsn iziniz ve PLC programn yaznz Y/ yol vermede, balatma butonuna basldnda motor nce Y balanarak devreye girer ve belirli bir sre sonra gen balanarak almasn srdrr.

CEVAP 18

K2 ve k3 kontaktrlerinin ayn anda devrede olmamas iin K2 kontaktr bobin devresine K3 kontaktr NK konta ve K3 kontaktr bobin devresine K2 kontaktr NK konta seri olarak balanmtr. Durdurma butonu S0 ve ar akm rlesi F2F durdurma ilevini yerine getirdiinden PLC girilerine normalde kapal kontaklar zerinden balanmtr.

UYGULAMA 19

Motor stator sarglar ebekeye balanmadan nce rotor devresindeki direnler maksimum deerde tutulur. Motor yol almaya baladktan sonra direnler kademeli olarak ksa devre edilir. Bylece, maksimum yol alma momenti ile motorun hzlanmas salanrken yol alma akm snrlandrlm olur.

CEVAP 19

UYGULAMA 20 ZAMANLAYICILAR 2.Retentive On Delay Timer (TONR): Girie gelen sinyalle beraber saymaya balar ve giri 1 olduu srece saymaya devam eder. Giri 0 olursa ierik ve bit sfrlanmaz. Mevcut deerini korur. erik ve biti sfrlamann tek yolu reset sinyalidir. 1ms T0, T64 10ms T1-T4, T65-T68 100ms T5-T31, T69-T95
KOUL SRE=8sn

SRE

Preset Time

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz; Start butonuna 2 sn aralklarla baslmaktadr Q0.0 knn 8 sn start butonu aktif olduunda kn deitirmesini salayan program. Stop a basldnda Q0.0 pasif olsun

CEVAP 20

UYGULAMA 21 SAYICILAR 1. Yukar Sayan Sayc (CTU): Sayc ierii belirtilen karlatrma deerine ulatnda ilgili biti 1 olur. Snrsz sayda sayc vardr. Sayc ierii >=PV ise Sayc biti =1 olur.

Her ykselen kenarda sayc ieriini 1 arttrr Sayc ieriini ve bitini sfrlar Karlatrma deeri

0~255 aras adres verilebilir

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz; Start butonuna 3 defa basldnda (3 ykselen kenar) Q0.0 aktif olsun Stop butonuna basldnda saycy resetlensin.

CEVAP 21

UYGULAMA 22 SAYICILAR 2. Aa-Yukar Sayan Sayc (CTUD): PV deerine ulaldnda CTUD biti 1 olur. CTUD karlatrma deerini (-) olarak da yapar. PV deerine gelene kadar CTUD biti 1 olur. PV deerini getiinde bit deeri 0 olur. CTUD ierii -32767 ile +32767 aralnda deiir. Her ykselen kenar geldiinde deeri bir azalr veya bir artar.

Her ykselen kenarda sayc ieriini 1 arttrr Sayc ieriini ve bitini sfrlar Sayc ieriini ve bitini sfrlar Karlatrma deeri

0~255 aras adres verilebilir

PRESET VALUE

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz; I0.0 ykselen kenar geldiinde C5i bir arttran, I0.1 ykselen kenar geldiinde C5i bir azaltan; sayc deeri 5e ulatnda Q0.0 aktif yapan I0.2 reset geldiinde sayc deeri sfrlansn

CEVAP 22

UYGULAMA 23 KARILATIRMA ELEMANLARI

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz;

Birinci ykselen kenarda 1 olacak, ikinci ykselen kenarda 0 olacak.

CEVAP 23

ZEL EVRM BTLER

UYGULAMA 24

L5

L4

L3

L2

L1

L0

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz;

CEVAP 25

UYGULAMA 26

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz;

CEVAP 26

UYGULAMA 27

FOTOSEL

STOP B1 B0

M4

M3

M2

FOTOSEL

B1 B0 M2 M3 M4

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz; Start butonuna basldnda B0 ve B1 bant motorlar hemen alr Bant zerinden geen rnler fotosel yardmyla saylmaktadr. Geen rn says 2 olduunda M2, 4 olduunda M3 ve 6 olduunda M4 alacaktr. Geen rn says 8 olduunda ise btn motorlar durmal ve saya resetlenmelidir.

CEVAP 27

UYGULAMA 28

STOP

FS-2

FS-1 P1

M1

FS-1 FS-2

P1

M1

Verilen PLC balantsna gre aadaki artlar salayan PLC program yaznz; Pinpon toplar onar onar paketlenecektir

CEVAP 28