You are on page 1of 2

Remote Terminal Unit-5/03 Processor

with Modbus Slave on Channel 0


3250-L532M
The ProSoft RTU-5/03 processor, aimed strategically at
the SCADA marketplace, is a Rockwell Automation SLC
5/03 processor that has been modified to include the
Modbus Slave protocol developed in Channel 0.
Features and Benefits
The full SLC command set functionality is available, and
Remote Terminal Unit-5/03 Processor with the unit is programmed with standard ladder
Modbus Slave on Channel 0 programming tools (RS Logix and APS). The Modbus
3250-L532M Slave protocol is enabled with the simple addition and
setup of an Integer file at N100. This file configures the
• Oil & gas Channel 0 Modbus driver and allows user control over
• Pipeline the operation of the port. In addition, extensive
• Off-shore platforms diagnostic data is returned from the driver to the integer
• Water/ waste water file, allowing access to troubleshooting data.
• Power utility and mining
After the Modbus protocol is activated, a Modbus host
How to Contact Us: Sales and Support can read and write data from all the common Modbus
data types (binary in and out, analog in, and holding
All ProSoft Technology products are backed with
registers). In addition, support has been provided for the
unlimited technical support. Contact our worldwide
transfer of floating-point data, which optionally uses the
Technical Support team directly by phone or email:
'Enron' addressing range. A host can also access the
Asia Pacific processor status file S2 to remotely monitor the health of
+603.7724.2080, asiapc@prosoft-technology.com the unit or to do such things as set the real time clock.
Languages spoken include: Chinese, Japanese, English
General Specifications
Europe – Middle East – Africa The ProSoft Technology, Inc. RTU-5/03 processor
+33 (0) 5.34.36.87.20, support.EMEA@prosoft- solution includes the following features:
technology.com
Languages spoken include: French, English • Channel 0 port supports Modbus Slave protocol
• Modbus read and write of binary, integer, and
North America floating-point data types
+1.661.716.5100, support@prosoft-technology.com • Modbus Master can read from or write to the
Languages spoken include: English, Spanish
processor Status File (S2)
Latin America (Sales only) • RS-232C handshaking for SCADA radio/modem
+1.281.298.9109, latinam@prosoft-technology.com applications
Languages spoken include: Spanish, English • Satellite and Packet Radio support with a
configurable Inter-Character Timeout
Brasil • Channel 0 Modbus Port configuration through entry
+55-11.5084.5178, eduardo@prosoft-technology.com of configuration values in Modbus Configuration and
Languages spoken include: Portuguese, English
Diagnostic File (N100) in ladder logic:
o Slave Addr : 1 to 127 (0 is broadcast)
o Parity : None, odd, or even
o Stop Bit : 1 or 2
o Baud Rate : 300 to 19,200
o RTS Send Delay: 0 to 2500 ms
o RTS Off Delay : 0 to 2500 ms
o Pre-Send Delay : 0 to 2500 ms
o Inter-character : 0 to 2500 ms
Functional Specifications Additional Products
The RTU-5/03 incorporates the Allen-Bradley SLC-5/03 ProSoft Technology offers a full complement of
technology. As such, it has all the standard features of hardware and software solutions for a wide variety of
the SLC 5/03, including: industrial communication platforms.
• DF1 programming support (uses standard ladder Visit our web site at http://www.prosoft-technology.com
logic tools for programming on Channel 0) for a complete list of products.
• Auto switch between DF1 and Modbus on Channel 0
• DH-485 network access and programming on
Channel 1 Ordering Information
• Up to 1024 inputs plus 1024 outputs To order this product, please use the following:
• 16K (3250-L532M) word memory configurations 3250-L532M Remote Terminal Unit
• Floating-point math support SLC 5/03 Processor
• On-line programming with Modbus Slave on Channel 0
• Run-time editing To place an order, please contact your local ProSoft
• Built-in key switch Technology distributor. For a list of ProSoft distributors
• Built-in real-time clock and calendar near you, go to http://www.prosoft-technology.com
Modbus Slave Specifications Distributors:
Place your order by email or fax to:
• Modbus protocol modes:
o RTU (binary) with CRC-16 error checking North American / Latin American / Asia Pacific
o ASCII with LRC error checking (7 and 8 bit) orders@prosoft-technology.com,
• Supported Modbus function codes: fax to +1 661.716.5101
o 1: read output status Europe
o 2: read input status europe@prosoft-technology.com,
o 3: read multiple data registers fax to +33 (0) 5.61.78.40.52
o 4: read input registers Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.

o 5: force single coil (latch/unlatch) January 19, 2007

o 6: write single data register


o 8: loop back test, test 0 only
o 15: multiple coil latch/unlatch
o 16: Write multiple data registers
• Supports broadcast commands form the Master

Specification Description
Backplane Current Load 500 mA @ 5 Vdc
175 mA @ 24 Vdc
Operating Temperature 0°C to 60°C (32°F to 140°F)
Storage Temperature –40°C to 85°C (–40°F to 185°F)
Shock 30 g operational
50 g non-operational
Relative Humidity 5% to 95% (with no condensation)
Vibration 5 g from 10 to 150 Hz
LED indicators RUN FORCE
FLT DH485
BATT MODBUS (RS232)
Processor Ports Connectors and Usage
Channel 1 RJ45 jack
(DH485 Port) Used for SLC Programming and
DH485 Communication
Channel 0 DB-9 Male
(RS232C Port) Used for SLC Programming and
DF1 or Modbus Communication

You might also like