You are on page 1of 2

SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)

SAIC NUMBER DATE APPROVED QR NUMBER


SAUDI ARAMCO INSPECTION CHECKLIST
Cast-In-Place Concrete Formwork Inspection SAIC-Q-1012 18-May-05 CIVIL-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

Forms shall be substantial and sufficiently tight to prevent leakage of


mortar from the concrete. Contractor shall use sufficient nailing, bolting,
SAES-Q-001
A1 welding, shoring, whalers, form clamps and forming of adequate strength
Sec. 8.0
to contain the fluid concrete without noticeable deflection, leaning or
bulging. (ACI 347, Sec. 3.1.1 & 6.1.2)

Forms shall be properly braced or tied together to maintain position and


shape. Forms shall be built to resist the pressures to which they will be SAES-Q-001
A2
subjected and to limit deflections to a practicable minimum within the Sec. 8.0
specified tolerance. (ACI 318, Sec. 5.5.1 & 6.1.3)

Forms and their supports shall be designed so as not to damage SAES-Q-001


A3
previously placed structure(s). (ACI 318, Sec. 6.1.4) Sec. 8.0

Foundations for formwork on ground, such as blinding concrete,


SAES-Q-001
A4 compacted fill or grade, spread footings, piles or slabs shall be provided.
Sec. 8.0
(ACI 347, Sec. 2.7)
Formwork shall be anchored to the shores below so that movement of
SAES-Q-001
A5 any part of the formwork system will be prevented during concreting.
Sec. 8.0
(ACI 347, Sec. 3.6.1.3)
Safety signs and barricades shall be erected to keep unauthorized
SAES-Q-001
A6 personnel clear of areas in which erection, concrete placing, or formwork
Sec. 8.0
stripping is under way. (ACI 347, Sec. 3.1)

Lifting points, scaffolds, working platforms, guardrails or other fall SAES-Q-001


A7
protection devices shall be included. (ACI 347, Sec. 3.1) Sec. 8.0
Blockouts, inserts, sleeves, anchors, waterstops and other embedded
items shall be properly identified, positioned and secured in the forms to SAES-Q-001
A8
resist all forces while concrete is being placed and hardens. (ACI 347, Sec. 8.0
Sec. 3.2.4.2)
Shores shall be installed plumb and with adequate bearing and bracing. SAES-Q-001
A9
(ACI 347, Sec. 3.2.1.3) Sec. 8.0

The size of form ties and clamps shall be as specified in the IFC SAES-Q-001
A10
drawings. (ACI 347, Sec. 3.2.1.4) Sec. 8.0

Irregularities in formwork surfaces measured with a 1.5m straightedge


shall not exceed: 3mm for Class A surfaces exposed to public view;
SAES-Q-001
A11 6mm for Class B areas to be plastered; 13mm for Class C where
Sec. 8.0
appearance does not matter; 25mm for Class D permanently hidden
concrete surfaces. (ACI 347, Sec. 3.4, Table 3.1)

Forms shall be thoroughly cleaned of all dirt, mortar and foreign matter SAES-Q-001
A12
and coated with a release agent before each use. (ACI 347 Sec. 3.2.5.1) Sec. 8.0

Building materials, including concrete, shall not be dropped or piled on


SAES-Q-001
A13 the formwork in such a manner as to damage or overload it.
Sec. 8.0
(ACI 347, Sec. 3.2.6.2)

Page 1 of 2
SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Cast-In-Place Concrete Formwork Inspection SAIC-Q-1012 18-May-05 Civil
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

Runways and formwork shall not be supported on the reinforcing steel. SAES-Q-001
A14
(ACI 347, Sec. 3.2.6.2) Sec. 8.0

A plasticized sheet vapor barrier shall be placed beneath and around the
SAES-Q-001
A15 sides of concrete that is placed where bitumen or coal tar epoxy cannot
Sec. 11.3
be applied.

A plasticized sheet vapor barrier, minimum 0.15mm thick, shall be SAES-Q-001


A16
placed beneath slabs on grade except for exterior sidewalks. Sec. 11.2

Joints not specified on IFC Drawings shall be installed to maintain the


SAES-Q-001
A17 Architectural Finished appearance, shall have prior approval by the
Sec. 14.1
Saudi Aramco representative.

Paving or slab construction joints not specified on the drawings, shall be


SAES-Q-001
A18 located at column centerlines and at intermediate intervals so that each
Sec. 14.2
panel shall not be more than 55m2 in area.

Waterstops shall be provided in joints where watertight construction is


SAES-Q-001
A19 required; waterstops shall be as shown on IFC Drawings or as specified
Sec. 14.3
by Saudi Aramco.

Joint filler strips shall be made from cellulose fibers or cork securely
SAES-Q-001
A20 bound together by a suitable asphaltic binder, sponge rubber, or PVC
Sec. 14.5
and the type shall be as called out on the IFC Drawings.

Joint sealers shall be elastomeric, single or multi-component, non-sag,


SAES-Q-001
A21 paintable and have good resistance to occasional hydrocarbon and
Sec. 14.6
lubricating oil spills.

REMARKS:

REFERENCE DOCUMENTS:
1- SAES-Q-001 -- Criteria for Design and Construction of Concrete Structures, 29 October 2003

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED

Page 2 of 2