You are on page 1of 9

Patch Panels

135
Content Page Introduction

NPPA-Series - 96 Bantam (TT) Jacks .......................... 138 Patch Panels are central switching gears between audio equip- The mechanical size is designed to fit into 1U 19“ standard racks.
Configuration, Grounding, Wiring ............................ 139 ments. They are used to switch and route analog and digital All Neutrik Patch Panels offer various normalling possibilities
NPP-TB-Series - 48 B-Gauge Jacks ............................. 140 audio signals from and to equipments in recording or broadcast between top and bottom row.
Configuration, Grounding, Wiring ............................ 141 studios, OB vans, churches, theatres, stadiums, arenas, etc.
1/4" Patch Panel NYS Series .................................... 142 Neutrik® Patch Panels are available in a varety of jack types, wir- All Neutrik® Patch Panels are able to handle digital audio signals
Configuration, Grounding ........................................ 143 ing and grounding possibilities. acc. AES3, 48kHz sampling rate.
MA 96 and XPM 96 Bantam Patchbays ..................... 144 Common versions accommodating Bantam TT, 1/4“ A-gauge
MAJ 501 Bantam Jack Socket ................................... 145 and longframe B-gauge jacks on the front rows are available.
LF 48 B-Gauge Patchbays ......................................... 146
LFJ 501 B-Gauge Jack Socket ................................... 147
Technical Data ........................................................ 148 Audio Normalling
Operating Accessories, Labeling software ................... 148
Ordering Information ............................................... 149
Audio Normalling is usually used with audio patch panels and
Definitions, Abbreviations & Useful Information ........... 151 is a wiring pattern in which a circuit path is established from
one piece of audio equipment to another without the use of a
patch cord. This pattern is then considered to be the „normal“
circuit path that is desired most of the time. If a patch cord is
inserted, the normal circuit path is interrupted and rerouted to
a different circuit path.
Normalled patch panels are most commonly found in vertical
jack pairs: the top jack is designated as the source and the bot-
tom jack is the destination.

Normalling example: HALF NORMALLED BOTTOM ROW

This is the most common configuration, very often called HALF


NORMALLED. In this configuration internal normalling contacts
connect the top jack contact with the
corresponding bottom jack contact.
Inserting a plug in the bottom jack
will interrupt this internal normalling
connection, while inserting a patch
cord into the top jack doesn‘t inter-
rupt the circuit. (Can be used to moni-
tor the normalling circuit)
Other versions of normalling are Half
Normalled Top Row, Full Normalled, Parallel and Isolated.

136 look for the logo www.neutrik.com 137


" E a s y P a t c h " P a t c h P a n e l " E a s y P a t c h " P a t c h P a n e l

Design Criteria
®
or reconfigured quickly and without fuss even while the
NJ3TTA gold plated double contact jacks (2 x 48), featuring panel is ”on air”. The NJ3TTA jacks offer also two contact
drastically improved contact integrity and are available with points per terminal (TRS) with a special designed mechanism
a wide choice of wiring terminations. The unit is finished off for the normalling contact. Simply remove the front panel to
with a built in cable bar and two large channel ident strips reveal the easy access jack. Remove, replace or reconfigure
Robust front design Easy assembly Jack-pair IDC terminals Push terminals ELCO connectors for perfect management of the system. the jack and refix the panel.
The new generation of the Neutrik® ”Easy-Patch” is easily The ”Easy-Patch” is an innovative and compact patching
programmable for any one of five configurations (standard system (just 1U high) for 19" rack mounting. Robustly
is half normalled bottom row) and for the grounding system housed in a black coated steel shell and featuring precision
of your choice. Each individual pair of jacks can be changed aluminium fittings it is built to last.
N P PA - S e r i e s - 96 Bantam (TT) Jacks
Configuration

The standard version of the NPPA Panel is delivered bottom row For individual normalling single pre-configured jack-pairs
half normalled for each jack pair by default. Further patch ver- are offered.
sions are available with fully loaded jack-pairs as: NPPA-TT-IDC is equipped with jumper blocks for individual
switching configurations of each jack channel.
LFull Normalled
LHalf Normalled Note: Take care when handling digital signals. Do not use
LIsolated parallel configuration and avoid other parallel paths when
LParallel using half normalled configurations. Parallel paths may lead
to mismatching.
NPPA-TT-PT
Half Normalled Bottom Half Normalled Top Full Normalled Parallel Isolated
    
    
    
L Innovative and compact patching system (just 1U high) for 19“ rack mounting
L Robustly housed in a black coated steel shell 















L Features 2 x 48 long life gold plated TT size (bantam) Neutrik NJ3TTA double contact point TRS jacks
L Available in all common normalling configurations (default Half Normalled Bottom)
L Qualified for analog and digital signals according to AES3, 48 kHz sampling frequency Grounding
L Remove the front panel for quick changes of the NJ3TTA-** modules for reconfiguration or repair even when "on air"
The flexible grounding system provides the following versions:
L Includes two built in cable bars and two wide channel ID strips
L PatchLink Software for printing onto labeling strips is on Neutrik website (available for PC only) LIndividual: Each channel is individually grounded by its corresponding cable shield (default configuration).
LGroup: Selected channel grounds are connected via the ground bus on the PCB using solder bridges and track cuts to form a
group that is connected to one common cable shield.
LCentral: All channel grounds (individual top and bottom row) are connected via the ground bus on the PCB using solder

bridges and wired with only one cable shield.


LChassis-Common: The same as central grounding but with the addition of the common ground bus (top and / or bottom
Dimensional Drawing
rows) connected to the patch panel chassis by means of jumpers

      
         
     

W i r i n g Te r m i n a t i o n s

TT Patch Panels offer different choices of wiring:

LSpring loaded push terminals The spring loaded terminal blocks enable fast and easy wir-
#$   #$   %  "  


L56 pin Elco/Edac male connectors ing. No soldering and screwing necessary. Simply insert the
L90 pin Elco/Edac connectors stripped wire after pressing down the white key. Terminals
    
     
 
 

    
 
 
 " 
  
 !

!
    
    
 
  


    

 
 

L50 pin D-SUB connectors accommodate stranded wires up to AWG 20 (0.5 mm2) and
 

   
  



 

  
 
 

 

L25 pin D-SUB connectors solid wires up to AWG 18 (0.75 mm2). Push terminals are
 
 
 


""&&"

LIDC-Krone terminals gas tight connections.


LSolder lugs

For Pin assignment of ELCO / EDAC and D-SUB connectors please see drawings on www.neutrik.com

138 look for the logo www.neutrik.com 139


" E a s y P a t c h " P a t c h P a n e l " E a s y P a t c h " P a t c h P a n e l

Design Criteria

The TB Patch Panel is a very robust and compactly designed The NPP is easily programmable for six switching configura-
Patch Panel for 19" rack mount (19" x 1U) with galvanized tions and for changing the flexible grounding system. All
metal housing, a built-in cable bar on the rear for securing panels have the high quality long life gold plated Neutrik®
wires. There is a rear extension bar (NPP-S) available as an NJ6TB-V Jack for the BPO / MIL style plugs. We have two
option for some panel types. On the front side we have an variants of rear connection. The standard is equipped with
Individual colour Galvanized metal
attractive additional lettering facility for each channel pair with spring loaded terminals strips and an optional version offers
coding housing
a marking strip and individual snap-on colour coding plates. solder lugs.

NPP-TB-Series - 48 B-Gauge Jacks Configuration


Due to the jumper blocks capability provided, the switching The TB Panel is delivered in a full normalled configuration
configurations available per jack channel are: for each jack channel. A non-configurable half normalled
("-HN") bottom row version with solder lugs is also avail-
LHalf Normalled Bottom Row able.
LFull Normalled NOTE: Take care when handling digital signals. Do not use
LParallel Parallel configuration and avoid other parallel paths with
LIsolated Half / Double Normalled configurations. Parallel paths may
lead to mismatching.

Half Normalled Bottom Half Normalled Top Full Normalled Parallel Isolated Double Normalled

NPP-TB-HN NPP-TB + NPP-LB*

L Features 2 x24 Neutrik® NJ6TB-V long frame 1/4” TRS jacks according to BPO316/MIL-P-642/2
L Very robust and compact galvanized metal housing
L Compact, cost effective system qualified for both analog and digital signals acc. AES3, 48 kHz sampling frequency
L High quality long life gold plated Neutrik jacks
Grounding
L Easily programmable for any of 6 configurations with 4 grounding choices
L Rear terminations include solderless terminal blocks or solder lugs The flexible grounding system allows four possibilities to fit your needs:
(solder for non-programmable half-normalled versions only).
L Individual: Each channel ground is separately connected with the corresponding cable shield (default configuration).
L Center marking strip is removable; See Neutrik website to download PatchLink labeling software for PCs L Group: Some channel grounds are PCB connected by making soldering joints on the PCB and by cutting tracks
L Color coded tabs, dust cover and rear extension strain relief bars are optional accessories respectively to form a group that is connected to one common cable shield.
L Central: All channel grounds are PCB connected by making soldering joints and wired with only one cable shield.
L Chassis-Common: Same as central grounding with additional connection of the common ground to the Patch
Dimensional Drawing Panel chassis by means of a jumper.

W i r i n g Te r m i n a t i o n s

TB Patch Panels are available with:

NPP-S (Accessories) L Spring loaded push terminals (NPP-TB)


L Solder lugs (NPP-TB-HN)
NPP-S

The spring loaded terminal blocks are fast and easy to connect and disconnect the wires.
No soldering and screwing necessary. Simply insert the stripped wire after pressing down the white key.
Accommodates stranded wires up to AWG 20 (0.5 mm2) and solid wires up to AWG 18 (0.75 mm2).

140 look for the logo www.neutrik.com 141


N Y S S e r i e s N Y S S e r i e s

Design Criteria

The NYS-SPP-L1 is a economical and remarkable sleek The PCBs are held securely in place by being clamped
designed 1/4“ modular Patch Panel for 19“ rack mount (19“ between the front and the rear panel, this grants an easy
x 1U) with a reinforced metal housing. Each of it‘s 48 PCB reconfiguration of the Patch Panel without the danger of
wired balanced channels (24 front pairs and correspond- loosing any small parts (e.g. nuts). The grey jack serves as an
ing 24 rear pairs) can either be grounded separately or in easy and distinguishable normalling identification.
Ruggedized metal Imprinted grounding Module
groups of inividually chooseable channel numbers (detailed
housing instruction NYS-SPCR1
information see below).

1/4" Patch Panel Configuration

Standard configuration, when delivered, is Half Normalled grey jack will always isolate the top against the bottom row.
bottom row. The configuration can easily be changed by Alternative solution for send/return applications by use of
just flipping the individual PCB. Inserting a plug into the NYS-SPCR1 module (see accessories below).

The following configurations are available:


Half Normalled Split Isolated Split Print

vorne hinten vorne hinten vorne hinten vorne hinten NEW! Mit Schaltkontakten
A vorne   
A A A A A A A  A Mono - Send
hinten
Send - Return
B vorne (Stereo Buchse)
B B B  B B B B B Mono - Return
(Red Jack) 
NYS-SPP-L1
Vordere Buchse A zum Graue B Buchse für Signal Erlaubt 1 Output to feed 2 Inputs Oberer (A) und unterer (B) Lösung für Eingangsbuchsen von
"Mithören" Eingang Kanal getrennt NYS-SPCR1 Mischpulten, Teilungsprint statt speziell
angeschlossenem Y-Kabel.
L Individual grounding available for each channel separately
L Ruggedized metal housing Grounding
L Improved contact design minimises wear on mated plugs
The flexible grounding system, applicable for each channel separately by simply attaching the loose supplied grounding clips
L Economic and versatile designed 1/4" modular Patch Panel with 2 rows of jack sockets
to the grounding pad of the corresponding channel, offers the following alternatives:
L 48 balanced channels with fully PCB wired jack (24 vertical PC boards), 24 front pairs and corresponding 24 rear pairs L Individual (without grounding clip): Each channel ground (sleeve contact) is connected to the dedicated ground
L Jack PC card contains 4 balanced 1/4" jacks with non-tarnishing contacts, is held securely in place without the use of nuts - contact of the incoming 1/4” plug only. This is the standard configuration for delivery.
no little pieces to drop, break or lose L Chassis common c: The relevant channel grounds (sleeve contacts; top and bottom row) is connected to the
ground flat tab via grounding clip and chassis.
L Easy to change configuration by just flipping individual PC board L Chassis top d: The dedicated top channel ground (sleeve contact) is connected to the ground flat tab via grounding
L Normalling jack is coloured grey for easy identification clip and chassis.
L 4 designation strips included for front and rear panel
L Chassis bottom e: The dedicated bottom channel ground (sleeve contact) is connected to the ground flat tab via
grounding clip and chassis.

Dimensional Drawing
Rear view detail:
Ground flat tab to be used with
FASTON receptacle or to solder
®

the wire.

grounding clip (slide onto the print)

142 look for the logo www.neutrik.com 143


B a n t a m P a t c h P a n e l s B a n t a m P a t c h P a n e l s

Standard 4.4mm Long frame jack Die-cast frame Tinned tags


bantam jack socket

MA 96 and XPM 96 Bantam Patchbays MAJ 501 Bantam Jack Socket

L Robust designed patchbay to accept standard 4.4 mm Bantam jack connectors (acc. MIL-D-642/13) L 5-point Bantam jack socket (Tip, Ring, Sleeve, Tip Normal, Ring Normal)
L Fitted with 96 Rean die-cast jack sockets L Rigid nickel plated die-cast frame, featuring considerable frame strength eliminating physical distortion when plug is inserted
L Constructed from rigid aluminium extrusion which includes 2 integral slots for designation strips L Nickel-silver spring contacts, palladium plated switch contacts
L 96 channels grouped in two row 12 x 8 stereo jacks L Tinned tags for easy soldering
L XPM96 features traditional 2 row, 4 x 24 stereo jacks
L Available in 4 colours: black, silver, red or blue
L Suitable for audio, broadcast, data and industrial applications XPM96

Dimensional Drawing Termination End Elevations Plan Elevations Circuit Detail

144 look for the logo www.neutrik.com 145


L o n g f r a m e B - G a u g e P a t c h P a n e l s L o n g f r a m e B - G a u g e P a t c h P a n e l s

B-Gauge patchbay 48 way longframe Solder lugs

LF 48 B-Gauge Patchbays LFJ 501 B-Gauge Jack Socket

L 48 way Longframe B-Gauge patchbay L 5-point B-Gauge jack socket


L Accepts both European BPO 316 and US MIL-P-642/2 style phono plugs L Nickel-silver spring contacts
L 2 rows of 24 LF501 jack connectors L Palladium plated switch contacts
L Jack designed from rigid nickel-plated die-cast aluminium with nickel-silver spring contacts L Durable die-cast body with bright nickel plated nose
L Available in 4 colours: black, silver, red or blue L Termination solder lugs
L Reliable support for connecting looms by steel lacing bar

Dimensional Drawing LFJ 501 Plan Elevations

Circuit Detail

146 look for the logo www.neutrik.com 147


T e c h n i c a l D a t a O r d e r i n g I n f o r m a t i o n

Spec i fi c ati o n s NPPA NPP-TB NYS MA 96 and LF 48 Part Number Description


Series Series Series XPM 96 Series

Electrical N P PA S e r i e s Configuration* Wiring Grounding


Contact resistance: < 20 m7 < 10 m7 < 10 m7 < 24 m7 < 20 m7 NPPA-TT-PT** 2 x 48 jacks half normalled bottom 288 push terminals individual
Switch contact resistance: < 25 m7 < 15 m7 < 10 m7 < 26 m7 < 15 m7 NPPA-TT-PT-FN** 2 x 48 jacks full normalled 288 push terminals individual
Insulation resistance: > 1 G7 @ 500 V dc z z z z z NPPA-TT-PT-HNT** 2 x 48 jacks half normalled top row 288 push terminals individual
Dielectric strength: > 500 V ac z z z z z NPPA-TT-PT-I** 2 x 48 jacks isolated 288 push terminals individual
> 1`000 V dc z z z - - NPPA-TT-PT-P** 2 x 48 jacks parallel 288 push terminals individual
Frequency range: DC to > 50 MHz z z z z z NPPA-TT-S** 2 x 48 jacks half normalled bottom 288 solder terminals individual
Channel separation: > 100 dB @ 10 kHz, 600 7 terminated z z z z z NPPA-TT-S-FN** 2 x 48 jacks full normalled 288 solder terminals individual
> 40 dB @ 6 MHz, 110 7 terminated z z z z z NPPA-TT-S-HNT** 2 x 48 jacks half normalled top row 288 solder terminals individual
AES / EBU Signals (digital) suitable: z z z z z NPPA-TT-S-I** 2 x 48 jacks isolated 288 solder terminals individual
Handles Phantom Power: z z z z z NPPA-TT-S-P** 2 x 48 jacks parallel 288 solder terminals individual
NPPA-TT-PT-PH 2 x 48 jacks half normalled bottom 288 Phoenix push terminals individual
Mechanical NPPA-TT-SD50 2 x 48 jacks half normalled bottom 4 x 50 pole D-SUB groups of 12 channels
NPPA-TT-SD25 2 x 48 jacks half normalled bottom 12 x 25 pole D-SUB groups of 12 channels
Life time: > 20`000 cycles - - - z z NPPA-TT-E56 2 x 48 jacks half normalled bottom 6 x 56 pole ELCO male connectors individual
> 10`000 cycles - - z - - NPPA-TT48-E56 2 x 24 jacks half normalled bottom 3 x 56 pole ELCO male connectors individual
> 5`000 cycles z z - - - NPPA-TT-E90 2 x 48 jacks half normalled bottom 4 x 90 pole ELCO male connectors individual
Insertion force: < 25 N - - - z z NPPA-TT-IDC 2 x 48 jacks programmable by jumpers 288 IDC terminals (KRONE-Type) individual
< 20 N - - z - - * fully loaded jack pairs only, to built patch panels with mixed configuration use pre-config jackpairs
< 10 N z z - - - ** in case of need added normalling bars can be used to reconfigure up to 4 jackpairs
Withdrawal force: > 10 N z z z z z
>8N z z - - - Pre-configured Jack-Pairs
Dimensions: 482 x 44 mm (19" x 1U) z z z z z
Depth : 178 mm (7") 140 mm (5.5") 64 mm (2.52") 110 mm (4.33") 115 mm (4.53") NJ3TTA-4-HNB blocks of 2 channels half normalled bottom row cover ident color: clear
Dimension Patch Box: 168 x 77 x 77 mm (6.0 x 3 x 3") NJ3TTA-4-HNT blocks of 2 channels half normalled top row cover ident color: yellow
Temperature range: - 30°C to + 80°C z z z z z NJ3TTA-4-FN blocks of 2 channels full normalled cover ident color: green
Mating plug: 4.4 mm (0.173") B-Gauge 1/4" plug A-Gauge 1/4" plug 4.4 mm (0.173") Longframe NJ3TTA-4-P blocks of 2 channels parallel cover ident color: red
Bantam plug acc. EIA RS-453 Bantam plug B-Gauge plug NJ3TTA-4-I blocks of 2 channels isolated cover ident color: orange
according MIL-P-642/13 BPO316/MIL-P-642/2 TEC60603-11 MIL-P-642/13 BPO316/MIL-P-642/2
Grounding wiring flat tab for 3/16" - - z - - Accessories
FASTON® (4.8 x 0.8 mm)
NPPA-S Strain Relief bar
NKTT* Patch cords with NP3TT-1 plugs. Available in black, blue, green, red and yellow. Lenght: 30, 40, 60, 90, 120 cm
Material

Housing: Steel Steel Steel anodised Al anodised Al NPP-TB Series Configuration Wiring
Front panel: anodised Al Pocan B 3225 Steel anodised Al anodised Al
NPP-TB 2 x 24 TB (BP0316/MIL-P-642/2) jacks programmable for all commonly used configurations push terminals
Lacing bar: Brass Steel N/A coated steel coated steel
NPP-TB-HN 2 x 24 TB (BP0316/MIL-P-642/2) jacks half Normalled Bottom Row solder tags
Jack housing: PA 66 blend PA 6.6 30% GR ABS diecast alloy diecast Al
Jack contacts: CuSn6 CuSn6 CuSn6 Ni-Silver Ni-Silver
Tribor® plated Au plated tin plated (CuNi18Zn20) (CuNi18Zn20) Accessories
Switch contacts: Au plated Au plated Bronze, tin plated Palladium plated Palladium plated
NPP-LB-** Channel identification and status plates, pack of 100 per color, 9 different colors
Grounding clip: - - CuSn6, SnCu plated - -
NPP-C Metal dust cover
NPP-S A second rear extention bar for fix the very large cables.
NKTB* Patch cord with NP3TB plugs. Available in black and red. Length: 30, 40, 60, 90 cm
Operating Accessories
**: 0 - Black, 1- Brown, 2 - Red, 3 - Orange, 4 - Yellow, 5 - Green, 6 - Blue, 7 - Violet, 8 - Grey, 9 - White; Must be ordered in multiples of 100.

Labeling software:
NYS SPPL
Patchlabel is a program to Label Patch Panel designation strips.
Free Download of Patch Label Program (ZIP - 347 KB) on the Web "www.neutrik.com" section NYS-SPP-L1 1/4" Patch Panel, 2 x 24 channels, configuration half normalled, isolated, split
"Patch Panels". NYS-SPCR1 Send / Return module (Split Print)

148 look for the logo www.neutrik.com 149


O r d e r i n g I n f o r m a t i o n Definitions, Abbreviations & Useful Information

Part Number Description


Definitions, Abbreviations & Useful Information

MA96 and XPM-96 ELEMENTS MEASUREMENT LEGEND

MA96-1A 96 way, Red front panel - grouped 12 x 8 Ag Silver N Newton


MA96-1D 96 way, Blue front panel - grouped 12 x 8 Al Aluminium 7 Ohm
MA96-1O 96 way, Black front panel - grouped 12 x 8 Au Gold µ Micro
MA96-1S 96 way, Silver front panel - grouped 12 x 8 Co Cobalt OD Outside Diameter
XPM-96SS 96 way, Silver front panel - grouped 4 x 24 Cr Chromium m Meter(s)
XPM-96SO 96 way, Black front panel - grouped 4 x 24
Cu Copper k Kilo
Ni Nickel
Bantam Jack Socket P Phosphorus ENGLISH TO METRIC CONVERSIONS
MAJ-501 Standard Solder Tag Pb Lead
Pd Palladium 1/8 inch 3.175 millimeters (mm)
Sn Tin 1/4 inch 6.35 millimeters (mm)
LF48 Longframe B-Gauge Patchbays Zn Zinc 1 inch 25.4 millimeters (mm)
2.54 centimeters (cm)
LF48-1A 48 way, Red front panel ALLOYS, PLASTICS, POLYMERS 1 foot 30.48 centimeters (cm)
LF48-1D 48 way, Blue front panel 0.3048 meter (m)
LF48-1O 48 way, Black front panel Brass (Alloy) CuZn39Pb3 6 feet 1.828 meters (m)
LF48-1S 48 way, Silver front panel Bronze (Alloy) CuSn6 50 feet 15.24 meters (m)
LFJ-501 Longframe B-Gauge jack socket, standard solder tag Ck 67 Carbon Steel 100 feet 30.48 meters (m)
EPDM Ethylene Propylene 1000 feet 304.8 meters (m)
GR Glass Reinforced
PA Polyamid(e) METRIC TO ENGLISH CONVERSIONS
PBTP Polybutylene Terephthalate
POM Polyacetal 1 centimeter 0.3937 inches
PTFE PolyTetraFluoroEthylene (TEFLON) 1 meter 39.37 inches
PUR Polyurethane 3.281 feet
10 meters 32.808 feet
50 meters 164.041 feet
100 meters 328.084 feet

OTHER ABBREVIATIONS

UL® Underwriters Laboratories


IP Rating Ingress Protection rating for objects and water ACC IEC529/EN60529
IEC International Electrotechnical Commission is the international standards and conformity
assessment body for all fields of electrotechnology
UL Recognized Component Mark
AWG American Wire Gauge

150 look for the logo www.neutrik.com 151

You might also like