You are on page 1of 3

Configuring actuate 8.0 reporting toll in MXES.

1) Don’t install actuate in program files directory. Install in c or d


drive.
2) Create a Maxadmin user with administrative privileges.
3) At the time of maximo installation specify volume names
instead of local host. And make sure of specifying correct
name.

If you get the following error while importing follow the steps
specified in the document.

"Specified user name or password is incorrect or this user does not


have administrator privilege."

1) The following configuration files contain your Actuate server name


and volume information. The references to the name of your server
and volume should be consistent from one file to another. If they do
not match you may receive the error noted above. Please check the
following files and ensure that the values for the iServer and volume
are correct and consistent.
-
<MAXIMOROOT>\applications\maximo\properties\maximo.pr
operties (if changed, rebuild maximo.ear)
- <MAXIMOROOT>\applications\activeportal\WEB-
INF\web.xml (if changed, rebuild acweb.ear)
- Actuate8\iServer\etc\acserverconfig.xml (if changed, restart
the Actuate Process Management Daemon service - PMD)
- Actuate8\iServer\etc\acpmdconfig.xml (if changed, restart
the Actuate Process Management Daemon service - PMD)

2) This issue can occur if Maximo is unable to bind to port 1099 upon
startup. This is the default port for binding but if another process is
using this port, Maximo will bind to an alternate port. Since the RSSE
component (Report Server Security Extensions) also has reference to
this port, the port will need to be changed to match that to which
Maximo is binding. To correct this issue, we will hardcode another
unused port for binding.

- In the
<MAXIMOROOT>\applications\maximo\properties\maximo.properti
es file, you will see the following:
mxe.rmi.port=0

On the line below this entry, add another line as follows :


mxe.registry.port=9898

This is how it should appear when finished:


mxe.rmi.port=0
mxe.registry.port=9898

*The port can be any available port on the system - 9898 is just for
example purposes. To check which ports are available, do a netstat a
and see which ports are being used. Use a port that does not appear
in this list.

- In the Actuate8\iServer\etc\rsse_maximo.properties, change the


maximo.port value to match the registry port specified in the
maximo.properties file.
For example,
#Rmi registry port for maximo. Default is 1099 if left
blank.
maximo.port=9898

- Once the changes have been made to each file, you will need to
rebuild the maximo ear file and restart the webserver.
- Restart the Actuate PMD service

- Wait for 1 minute after the PMD starts and then access the acadmin
via http://servername:8900/acadmin. In the dropdown, select the
volume and try logging in as your maxadmin user. If the error
persists, continue to the next step.

3) Another reason for this error could be that the businessobjects.jar


file for Maximo is out of sync with the actuatebo.jar file for Actuate.
This can happen if Maximo was updated to a new patch level but a
new jar file wasn't updated on the actuate server.

To determine if this is a problem, perform the following:


- Stop the Actuate Process Management Daemon (PMD) service
under Control Panel.
- Navigate to the
C:\Actuate8\iServer\servletcontainer\webapps\acrsse\WEB-
INF\lib directory. Move the actuatebo.jar to another folder outside of
this directory. (do not simply rename this file).
- Navigate to the MAXIMO\deployment\default folder and open the
maximo.ear file with winzip. Locate the businessobjects.jar and
extract it to the actuate folder listed above - in place of the
actuatebo.jar
- Restart the PMD
- Wait for 1 minute after the PMD starts and then access the acadmin
via http://servername:8900/acadmin. In the dropdown, select the
volume and try logging in as your maxadmin user. If the error
persists, continue to the next step.

4) Another reason why this error can occur is if the RSSE component
is using cached information. To eliminate this issue, it is
recommended to "refresh" the RSSE Service by following the
following steps:

- Stop the Actuate PMD process.


- Navigate to the Actuate8\iServer\etc folder and open the
acserverconfig.xml file with notepad. Locate the following line:
EnableRSSEService="true"
Change this value to false and save the file
- Go up one directory level to the iServer folder and delete the encyc
folder
- Restart the Actuate PMD Service
- Login to the Actuate acadmin via System Administration. Click the
System Volumes link and then click the volume name listed. Under
the Open Security tab, select the radio button to enable as a
webservice. Click OK and logout.
- Stop the PMD again
- In the Actuate 8\iServer directory, delete the new encyc folder that
was created ( this is created with each restart)
- Restart the PMD.
- Wait for 1 minute after the PMD starts and then access the acadmin
via http://servername:8900/acadmin. In the dropdown, select the
volume and try logging in as your maxadmin user

You might also like