The GE10 engine family is a 12 MW range Engine Characteristics
heavy-duty gas turbine, available in either
a single or a twin-shaft configuration.
It is the evolution of the field proven
GE10-1 The gas turbine is the well
proven GE10-1 Engine, a
heavy duty single shaft
engine that has accumulated
PGT10 and incorporates the latest in
aerodynamic design, and compact and
versatile package arrangements.
Gas Turbine a very large number of fired
hours, and has leveraged the
experience of the previous
The GE10 engine design has been highly PGT10.
refined based on the extensive experience The cases are horizontally
gained operating in all types of split and the rotor has a disk
architecture.
environments.
The combustion system
There are many units running under consists of a horizontally
conditions ranging from the cold of positioned single can; the
Alaska to the heat of the desert and the GE10-1 is available in both
humidity of the tropics. Diffusion Combustion System
Its efficiency and operational flexibility and DLN (Dry Low NOx)
make the GE10 a cost-effective choice versions and is able to burn a
wide range of liquid and gas
for all applications
fuels, including Low BTU gas
and hydrogen.
Fuel Gas System operation of the unit is Package Arrangement Axial Compressor Turbine Lubrication and Bearings
A typical gas fuel configuration supplied, including: The gas turbine enclosure The compressor is a high The single-shaft version is The on-base integrated
employs shutoff valves for • Unit control panel consists of a separate Performance, eleven-stage optimized for power lubrication system feeds the
safety reasons and metering structure and panels mounted axial flow design with a 15.5:1 generation applications. gas turbine, the speed
valves to control the machine • Motor control center on a base plate. Access doors pressure ratio derived from The turbine consists of three reduction gear and the driven
load and CO/NOx emissions. are included for normal GE Aircraft Engine transonic reaction stages. generator.
Depending on the level of DLN • VFD for gas turbine maintenance operations and flow aero design technology. In the first two-stages, the hot The lube oil tank is integral
performance requested, two starting inspections. The ventilation The rotational speed is 11000 gas parts are cooled by air with the gas turbine base
or three metering valves are • Generator control and system for internal cooling of rpm with a mass flow of 47 extracted from the axial plate. The main lube oil pump
needed in order to control gas protection panel the package consists of two kg/s. The antisurge margin compressor. is a VFD Type and a DC electric
injection in the various parts 100% axial fans. exceeds 25%. Advanced 3D The second and third stages motor driven pump is provided
of the combustion chamber. • DC panel & battery charger The enclosure includes fire & airfoils are used for vanes and have interlocked shrouds to for emergency backup.
gas detection systems and an blades, and the first three rows limit tip leakage and blade A stand-by pump identical to
• Batteries automatic CO2 type fire of stator blades are adjustable vibration. the main pump is available as
Unit Control Panel fighting system. to optimize operability. an option in order to allow
• On site monitoring system
The GE10 control system is The enclosure guarantees a The compressor rotor cold side continuous operation in the
standardized to assure a high The cab is provided with an sound pressure level lower (the fixed point of the gas Generator and Gearbox event of a main pump failure.
degree of integration air conditioning system, than 85 dBA at 1m. turbine) accommodates the The unit is equipped with: In the standard package
between the turbine and the normal and emergency For indoor applications, an 80 load flange.
• an open, air cooled four-pole configuration, the oil is cooled
generator. The system is lighting, a smoke detection dBA version is available upon This configuration guarantees
11kV generator (6.6kV CACA with an air cooler; a water
based on the GE Fanuc RX3i system and manual fire request. reduced flange movement
also available). cooler can be provided upon
PAC System platform with suppression bottles. The GE10-1 package is during gas turbine thermal customer request.
remote I/O modules. designed specifically for transients. • Jacking oil system The thrust and journal bearings
The Bently Nevada 1701 is power generation applications A patented GECC-1 aluminum • Anti-condensation heater are of the tilting pad type.
installed for the acquisition of Air Filter and is optimized to minimize ceramic coating is provided for
plant dimensions and to application in marine • Brushless excitation system
data from seismic probes and The air filtration system
for humming detection. The consists of a “pulse jet type” reduce maintenance cost and environments. • Seismic probes Starting System
control, monitoring and tuning filter house, an inlet duct and time. • Thermocouple for each In this package, the Electric
of unit parameters can be a silencer. The single lift architecture bearing and each phase Generator is provided with an
performed remotely. Remote The Pulse Jet system also minimizes the site installation Combustion System LCI VFD starting panel that
and commissioning lead time. and Emissions • Ventilation silencers
data acquisition does not provides an anti-icing allows it to be used as the gas
interfere with normal site function without any The integrated control cab The combustion system The gearbox is directly turbine starter. The panel
operations. additional hardware. eliminates civil works for the consists of a single, slot-cooled connected to the generator allows the generator to act as
Filter inspection and control room and site wiring combustion chamber assembly and the entire gear is a motor until the machine
replacement of filter activities. that permits easy maintenance supported by the generator reaches the self-sustaining
Control CAB cartridges are facilitated by of the hot gas path. casing without an external speed. At that point, the
An integrated control cab gangways and ladders that This combustion chamber is coupling. generator function is switched
containing all electrical are included as part of the Available Options able to burn a wide range of to generation mode to achieve
panels for control and scope of supply. • Dual Fuel DLN version fuels, from liquid distillates to synchronization as soon as a
(liquid + gas fuel) residuals, to all gaseous fuels, suitable rpm is reached.
• 6.6 kV IP55 CACA including low BTU gas. The
Electric Generator broad fuel capability of this
• 80 dBA sound pressure combustor is due to the
level package variable geometry design
• Indoor version patented by GE. A NOx level of
• H2O oil cooler 25 ppmvd @ 15% O2 is
• STD exhaust duct (12 m) guarantee over a wide load
• Lubrication stand-by pump range.
• Control cabinet located DLN Dual Fuel version (liquid +
alongside the unit gas fuel) is also available.
• Additional Pre-Engineered
BN1701 for complete
vibrational monitoring
5.4 m 12.6 m 6m
GE10 Gas Turbine Maintainability
SPECIFICATIONS GE10 maintenance can be The Global Services Portfolio • A Customer Care Center for
carried out either “on-site” or includes: a direct link to GE’s Oil &
Axial Compressor • 11-Stage Axial Flow at an authorized shop. Gas experts. Call any time
• 15.5:1 Pressure Ratio An engine exchange to get technical support or
• Comprehensive training by
maintenance approach can be information about products,
Combustion Chamber • Single Can Combustor highly qualified experts
adopted to maximize the unit offerings and orders.
• Pollution prevention: DLN Gas Available using a combination of
availability. traditional and modern
DLN Dual Fuel Available Enclosure doors, and flexible interactive training • An Inventory of GE Oil & Gas
Turbine piping and electrical connectors materials and tools capital parts available to
GE10-1 • 3-Stage HP Turbine 11000 rpm permit the engine to be easily supplemented by our satisfy emergency needs,
removed, and a back-up manufacturing, testing and
Nominal Rating - ISO At 15 °C, Sea Level, No External Pressure Losses, Relative Humidity including complete
engine quickly installed to repair facilities.
60%, Natural Gas Fuel with LHV = 32 to 44 MJ/Nm3 modules.
minimize the plant down time.
The engine is provided with
GE10-1 borescope holes for periodic • Remote Monitoring and • Qualified GE regional
inspection of the internals, and Diagnostics (RM&D) for service shops guaranteeing
ELECTRICAL OUTPUT (kW) .............................. 11250
the combustion chamber can accurate and continuous quality repairs and reducing
ELECTRICAL EFFICIENCY (%) .............................. 31.4 assessment of your
be disassembled without turnaround time.
EXHAUST FLOW (kg/sec) .............................. 47.5 removal of any of the engine equipment condition and for
EXHAUST TEMPERATURE (°C) .............................. 482 casings. GE gives the highest maintenance planning to
priority to engineering and maximize your plant output. • Contractual Service
field assistance and offers It is equivalent to having a Agreements to provide
GE10 Gas Turbine continuous technological team of experts in your maintenance services at a
Performance Curves improvements, tailored solutions plant 24 hours a day 7 days predetermined cost and on
and support for each machine. a week. a priority basis.
530,0 60,0
Effect of Compressor Inlet
Exhaust Temperature (°C)

520,0
Temperature on Exhaust 510,0
Exhaust Flow (kg/sec) 50,0

Temperature and Exhaust Flow 500,0 40,0


490,0
Base Load with zero inlet and 480,0
30,0

zero exhaust pressure drops 470,0 20,0

at Sea Level, 60% RH - 460,0


10,0
450,0
Natural Gas 440,0 0,0
-15 0 15 30 45 -15 0 15 30 45
Tamb (°C) Tamb (°C)

16000,0 13000,0
Effect of Compressor Inlet 14000,0
Heat Rate (kJ/kWh)

12500,0
Generator Output (kW)

Temperature on Output and 12000,0


12000,0

Heat Rate 10000,0


11500,0
8000,0
Base Load with zero inlet and 6000,0
11000,0

zero exhaust pressure drops 4000,0


10500,0

at Sea Level, 60% RH - 2000,0 10000,0

Natural Gas 0,0


-15 0 15 30 45
9500,0
-15 0 15 30 45
Tamb (°C) Tamb (°C)

29,0

Nominal Steam Production 27,0 Saturated Steam


25,0 200°C
Steam Flow (t/hr)

Capability in Cogeneration and 23,0


260°C
300°C
355°C
Combined Cycle 21,0
19,0
17,0
15,0
13,0
11,0
5 10 15 20 25 30 35 40 45
Steam Pressure (bar abs.)