Professional Documents
Culture Documents
EuroCO
Front cover: Elderly peoples’ home,Tegelen, the Netherlands.
EuroCO is a natural louvred ventilator Wide range of applications - EuroCO Durable - EuroCO is manufactured from
that is available in a wide range of sizes, is classed as a dual purpose ventilator, tough, corrosion resistant aluminium,
louvre options and control options. It is providing both day to day and smoke alloy, grade 3005 in accordance with
suited to most industrial and commercial control ventilation. Polycarbonate and EN573-3, with stainless steel fixings.
buildings and can provide both day to day glass versions allow the entry of natural Louvres pivot on double nylon UV-
and smoke ventilation, as well as permit daylight. EuroCO is also often used as a resistant bearings.
the entry of natural daylight if fitted with termination piece for large ducted or air
glass or polycarbonate blades. handling systems. There are pneumatic, Quality of manufacture - EuroCO is
electronic or hand controls and a wide manufactured under the BS EN 9001
EuroCO can also be installed in the range of louvre types, accessories and quality standard. Each unit is given a
vertical either for low level air inlet or for finishes. functional test before despatch.
high level extract.
High performance - EuroCO is Low maintenance - EuroCO units have
Louvred ventilators are popular with aerodynamically efficient and has a high very low maintenance requirements.
Specifiers and Contractors because of the resistance to weather.
wide range of options available, and with Design service - Colt provides a pre-order
Building Operators and Owners because Proven performance - EuroCO has been design service. Please contact Colt for
of their simplicity and low maintenance. exhaustively tested and certified to EN more information relating to the
They are among the most cost-effective 12101-2: 2003 in accredited third party application, specification, installation or
kinds of natural ventilators. test laboratories. For further details, see servicing of EuroCO.
page 5.
7 Wulfren Centre,Wolverhampton.
1 2
4 5 6
7 8
3
OPTIONS
Single skin aluminium (with option of 24v dc or 230v ac OPV addressable Birdguards, insect guards, security guards
low-loss brush seals to minimise air electronic controls: failsafe open or or burglar guards are available as factory
leakage or dust entry when closed) close, or power to open and close. fitted options.
Insulated double skin aluminium Option of a thermal release mechanism
(with option of low-loss brush seals) to open the vent at a pre-defined Other accessories
Twin wall opaque or clear temperature (72, 93 or 141ºC)
polycarbonate, with rubber seals irrespective of the incoming control Optional accessories include fusible link
Single skin laminated or toughened signals. For more details, see page 10. shields, base extension plates, base covers
glass, with rubber seals and supports, sheeting closure pieces.
Pneumatic controls: failsafe open or
Flanges close, or double locking. Option of a Paint finishes
thermal release mechanism to open the
For installation of EuroCO into a facade, vent at a pre-defined temperature (68 EuroCO is available mill finish, polyester
whether this is into curtain walling, or 93 ºC). irrespective of the incoming powder coated to a RAL colour, or with a
glazing or prepared openings, a front- control signals. special finish such as PVF2.
flanged variant is available . The flange
position is variable, depending on how far Manual. Option of a thermal release
out from the building the ventilator is mechanism to open the vent at a pre-
allowed to protrude. defined temperature (72, 93 or 141ºC)
For fixing details, see pages 12 and 13. irrespective of the incoming
control signals.
4
Opposite: Sony, the Netherlands.
EuroCO has been successfully designed Opening against side Ventilator will open Pass
and tested by accredited third party test wind of 10 m/s in a strong wind
laboratories in accordance with EN
12101-2: 2003 according to the following Aerodynamic tests Ventilator will perform See tables on pages 8-9
parameters. as efficiently as specified.
Tested with the above
mentioned side wind
Wind suction load When closed the ventilator Varies according to louvre
has to withstand the negative type. EuroCO meets
(suction) pressure of the class. WL 1500 (1.5 kPa) with
louvre blades wider than
1.5m, and WL 3000
(3.0 kPa) with louvre
blades under 1.5m wide.
5
DIMENSIONS
EE== A 145
A + 145
DD == BB +
+ 23
23
CC == A
A++ 98
98
278
A
A
BB
6
LOUVRE TYPES, U VALUES & AIR PERMEABILITY
Louvre type A1. Single skin A2. Insulated double skin PC/PO.Twin wall opaque GR. Single skin Georgian
aluminium (with option aluminium (with option or clear polycarbonate wired laminated or toughened
of low-loss brush seals) of low-loss brush seals) with rubber seals glass, with rubber seals
For a low-loss ventlator air permeability varies between 130 and 230m2/h/m2 at 50 Pa, depending on ventilator size.
7
WEIGHTS
Width code
The controls options affect the weight of Length 06 10 12 15 18 22
the ventilator. code
10 8.5 16.3 19.8 28.0 37.3 40.8
Add 5kg for OPV electronic controls, 13 10.5 19.3 22.8 31.5 41.8 45.8
2.8kg for pneumatic controls and 1kg for 14 10.5 19.3 22.8 31.5 41.8 45.8
manual controls. 15 12.5 22.3 25.8 35.0 46.3 50.8
18 14.5 25.3 28.8 38.5 50.8 55.8
22 17.5 29.8 33.3 43.8 57.5 63.3
25 19.5 32.8 36.3 47.3 62.0 68.3
27 21.5 35.8 39.3 50.8 66.5 73.3
29 22.5 37.3 40.8 52.5 68.8 75.8
30 23.5 38.8 42.3 54.3 71.0 78.3
32 25.5 41.8 45.3 57.8 75.5 83.3
36 28.5 46.3 49.8 63.0 82.3 90.8
38 29.5 47.8 51.3 65.0 84.5 93.7
8
B = Coefficient Cv AERODYNAMIC PERFORMANCE
Width code continued
Length 06 10 12 15 18 22
code
10 0.70 0.65 0.65 0.65 0.65 0.65
13 0.70 0.65 0.65 0.65 0.65 0.65
14 0.70 0.65 0.65 0.65 0.65 0.65
15 0.70 0.65 0.65 0.65 0.65 0.65
18 0.70 0.65 0.65 0.65 0.65 0.65
22 0.70 0.65 0.65 0.65 0.65 0.65
25 0.70 0.65 0.65 0.65 0.65 0.65
27 0.70 0.65 0.65 0.65 0.65 0.65
29 0.70 0.65 0.65 0.65 0.65 0.65
30 0.70 0.65 0.65 0.65 0.65 0.65
32 0.70 0.65 0.65 0.65 0.65 0.65
36 0.70 0.65 0.65 0.65 0.65 0.65
38 0.70 0.65 0.65 0.65 0.65 0.65
9
EN OPV CONTROLS
Colt recommends use of 24v dc or 230v The EN OPV system includes a battery temperature (generally either 72, 94 or
ac OPV electronic controls. EN OPV backup unit offering two independent 141OC), if no fire override signal has
revolutionises the control and operation of power sources to operate a ventilator, in received, the ventilator will failsafe to its
smoke control systems, enabling all accordance with the latest EN standards. open position.
addressable equipment to be integrated This unit ensures that if there is a power
within a complete intelligent electronic failure the ventilator will remain shut for a Please see the EN OPV leaflet for more
control system, enabling any alterations to pre-programmed duration, thereby details.
the scheme to be accommodated by reducing the prospect of water ingress,
simple changes in the software, and unless there is a fire signal, whereupon the
allowing monitoring and fault-diagnostics. ventilator will revert to its failsafe position
(normally open). After that time has
The user can operate the system manually elapsed, the ventilator will default to the
at the control panel keypad and can open position.
amend the daily parameters such as the
temperature settings and operating times. As an additional precaution, once the air
adjacent to the ventilator reaches a pre-set
10
EuroCO Rain Sensing
Ventilator Head
Breakglass
Apollo® comms line
* VENT STATUS
VENT FAULT
Open / Close
Configure
OPERATING INSTRUCTIONS
CONTROL FAULT This panel is for the day to day control of
ventilators. Use the arrow keys to choose
from the menu the function required.
Press the SELECT key to carry out this
TS
function. To return back through the menu
Temperature Sensor
FIRE SIGNAL press the CANCEL key. Use the diagram
below to guide you.
MAIN STRUCTURE
SUPPLY HEALTHY
Main Menu
monitors the 7
4
8
5
9
6
Vent Status
Open
Open / Close
Close
Configure
S/W Channel
health of the 1
*
2
1
3
//
All Zone Individual
Time Control
Set Points
Colt system
Colt International Ltd,
LAMP ALARM New Lane, Havant, Hampshire,
TEST SILENCE RESET PO9 2LY.
Tel: (01705) 451111
AUTO AUTO
AUTO
AUTO AUTO
AUTO AUTO
AUTO AUTO
Mains in
AUTO AUTO
AUTO AUTO
AUTO
Fireman’s
overide panel
11
.
FIXING DETAILS
N2 N3 N7
ROOF SHEETING
INTO GLAZING
N5
N1 - D N1 - U N1 - 16 N1 - 24
12
1 Ma On Shan Indoor Games Hall, Hong Kong.
4 Microsoft, Reading.
1 2
4 5
TYPICAL FIXING DETAIL
INTO BRICKWORK
(front flanged version shown)
13
Above: Hong Kong International Exhibition Centre.
SPECIFICATION
14
1 CCM Prague, Czech Republic.
4 Ratiopharm,Vienna.
1 2 3
5 6
15
THE COLT PACKAGE SERVICE AND MAINTENANCE
Colt International offers the following Other reasons to choose Colt: Maintenance of a smoke control system
services: is essential. Regular maintenance
Colt Smoke Control systems are suited protects your investment and brings
Scheme design of all types of Smoke to both commercial and industrial peace of mind that the system will
and Heat Exhaust Ventilation Systems buildings, and may be adapted to suit operate effectively in an emergency.
(SHEVS) most architectural requirements.
Scheme design of pressurisation The British Standard BS 5588-12
systems Over the years Colt has funded a large recommends that smoke control systems
Scheme design of smoke containment proportion of the research into smoke should be serviced at least once a year
systems control, and its representatives and tested weekly.
Provision of performance specifications maintain an unparalleled level of
Project management technical expertise. Colt offers a comprehensive range of
Supply, installation, commissioning maintenance packages incorporating the
and maintenance of systems, including Colt's in-house research and maintenance and repair of all building
all necessary controls, which will be development capability ensures that services equipment including non
designed to interface with others' Colt smoke control systems are Colt products.
control systems. designed, tested and updated by Colt
to meet or exceed relevant legislation
and standards.
“Colt” and the Colt logo are registered trademarks of Colt International
“People feel better in Colt conditions” Architectural Solutions Colt International Limited
www.coltgroup.com
terna
In t Climate Control
io
Colt
nal
Smoke Control
6
1
3
0
9