You are on page 1of 3

NEPLAN - Electricity

Available modules for MS-Windows XP, 2000, NT

50 100 300
Modules Code nodes nodes nodes unlimited remarks
Graphical Database Editor GR
Load Flow LF
Short Circuit SC
Motor Starting MS LF required
Overcurrent Protection (Selectivity Analysis) OCP
Distance Protection DP LF+SC required
Arc Flash Calculation ARC SC required
Harmonic Analysis HA
Optimal Separation Points and Network re-supply OSP LF required
Load Profile Time Simulation LP LF required
Optimization of Distribution Networks ODN OSP required
Optimal Capacitor Placement CP LF required
Feeder Reinforcement (economic Cable Sizing) FR LF required
Current Transformer Saturation CT SC required
Cable Thermal Analysis TA SC required
Network Reduction NR LF+SC required
Optimal Power Flow OPF
NEPLAN Transient Stability (Dynamic Analysis) DA LF required

NEPLAN Small Signal Stability (Eigenvalue Analysis) SSS LF required

Simpow Phasor Mode (Transient Stability) S1 LF required

Simpow Instantaneous value Mode (EMT S2 S1 required


Simulation)
Simpow DSL for Primary Components S3 S1 and S6
required
Simpow Linear Analysis, phasor mode S4 S1 required

Simpow Linear Analysis, instantaneous value mode S5 S2 and S4


required
Simpow DSL Basic and commands S6 S1 required

Voltage Stability (Eigenvalue Analysis) VS LF required


Available Transfer Capability Analysis (ATC) ATC LF required
DACF Analysis (level 1) DACF LF benötigt
Cable Sizing (requires modules LF+SC+OCP) CS LF+SC+OCP
Connection request acc. to VSE/VEÖ and VDEW AG
Investment Analysis IA
Fault Finding FF LF+SC required
SQL Database Driver ODBC
SQL Database Converter CON
Interface to SCADA and GIS systems GIS
PSS – Import/Export PSS
UCTE Interface UCTE
Reliability Analysis RA LF required
Optimal Maintenance Planning OMP

The graphical database editor is required for all calculation modules

BCP Busarello + Cott + Partner AG www.neplan.ch, bcp@neplan.ch 08.12.2005


NEPLAN - Electricity

50 100 300
Packages Code nodes nodes nodes unlimited

Base Package BASE


(GR + LF + SC)
Protection Package PROT
(BASE + DP + OCP)
Industrial Package IND
(BASE + MS + OCP)
Distribution Package DIST
(BASE + OSP + LP + CP)
Transmission Package TRANS
(BASE + OPF + S1 + VS + S4)
Dynamic analysis Package DYN
GR, LF,S1, S2, S4, S5
Developers Package DEV
GR, LF, S1, S2, S3, S4, S5, S6

BCP Busarello + Cott + Partner AG www.neplan.ch, bcp@neplan.ch 08.12.2005


NEPLAN – Gas, Water, District Heating
Available modules for MS-Windows XP, 2000, NT

50 100 300
Modules Code nodes nodes nodes unlimited

Gas GA
(Graphical Database Editor +Gas Pipeline Calculation)
Water WA
(Graphical Database Editor + Water Pipeline Calculation)
District heating FW
(Graphical Database Editor + District heating pipeline
Calculation)
Length Profiles for Gas and Water LP
Water - Time Simulation for Gas and Water TS
Firewater-Plan FIREW
Database Driver (ODBC) ODBC
Interface to SCADA and GIS systems GIS

50 100 300
Packages Code nodes nodes nodes unlimited

Gas Advanced Package AGA


(GA + LP)
Water Advanced Package AWA
(WA + LP + TS)
Gas + Water Base Package BGW
(GA + WA)
Gas + Water Advanced Package AGW
(GA + WA + LP + TS)

BCP Busarello + Cott + Partner AG www.neplan.ch, bcp@neplan.ch 08.12.2005

You might also like