MATERIALS fcu N/mm2 40 STATUS Legend


fyv N/mm2 460 VALID DESIGN
link Ø mm 10

DIMENSION A mm 300 E mm 150


B mm 500 F mm -50
G mm 125 H mm 100

LOADING Vt kN 2954 Veff = kN 3397.1


ult UDL kN/m2 16.10

SLAB h mm 525 dx mm 484 Asx mm2/m 5362


dy mm 455.5 Asy mm2/m 3908
ave d mm 469.75 ave As % 0.983

RESULTS Veff = 3397.1 kN vc = 0.7349 N/mm2 (Table 3.8)


At col. face, v max = 4.899 N/mm2 At 1.5d perimeter, v = 1.0886 N/mm2
At 3d perimeter, v = 0.5896 N/mm2

PROVIDE LINKS (single leg) .

Perimeter 1 15 T10 @ 240 234 from col face


Perimeter 2 21 T10 @ 295 587 from col face
Perimeter 3 29 T10 @ 300 940 from col face
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0 Plan
0 0 0
REINFORCED CONCRETE
Project Spreadsheets to BS 8110 COUNCIL
Client Advisory Group Made by Date Page
Location Column B2 EDGE rmw 08-Dec-2021 32
PUNCHING SHEAR to BS8110:1997 COLUMN Checked Revision Job No
Originated from RCC13.xls v2.2 on CD © 1999-2003 BCA for RCC chg - R68

MATERIALS fcu N/mm2 40 STATUS Legend


fyv N/mm2 460 VALID DESIGN
link Ø mm 8

DIMENSIONS A mm 250 E mm 350


B mm 200 F mm -75
D mm 200 G mm 150
H mm 150

LOADING Vt kN 1012.1 0 0 1399


ult UDL kN/m2 16.10

SLAB h mm 525 dx mm 490 Asx mm2/m 2010


dy mm 470 Asy mm2/m 1340
ave d mm 480 ave As % 0.348

RESULTS Veff = 1416.9 kN vc = 0.5198 N/mm2 (Table 3.8)


At col. face, v max = 3.277 N/mm2 At 1.5d perimeter, v = 0.8025 N/mm2
At 3d perimeter, v = 0.4343 N/mm2

PROVIDE LINKS (single leg) .

Perimeter 1 13 T8 @ 165 240 from col face


Perimeter 2 19 T8 @ 180 600 from col face
Perimeter 3 24 T8 @ 200 960 from col face
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0 Plan
0 0 0
REINFORCED CONCRETE
Project Spreadsheets to BS 8110 COUNCIL
Client Advisory Group Made by Date Page
Location Columns A1, D1, A5 & D5 CORNER rmw 08-Dec-2021 33
PUNCHING SHEAR to BS8110:1997 COLUMN Checked Revision Job No
Originated from RCC13.xls v2.2 on CD © 1999-2003 BCA for RCC chg - R68

MATERIALS fcu N/mm2 40 STATUS Legend


fyv N/mm2 460 VALID DESIGN
link Ø mm 8

DIMENSIONS A mm 400 E mm -50


B mm 250 F mm -250
C mm 0 G mm 100
D mm 0 H mm 100

LOADING Vt kN 272.0 0 0 350


ult UDL kN/m2 16.10

SLAB h mm 250 dx mm 215 Asx mm2/m 2010


dy mm 195 Asy mm2/m 2010
ave d mm 205 ave As % 0.983

RESULTS Veff = 340.0 kN vc = 0.8686 N/mm2 (Table 3.8)


At hole face, vmax = 2.745 N/mm2 At 1.5d perimeter, v = 1.6585 N/mm2
At 4.5d perimeter, v = 0.7741 N/mm2

PROVIDE LINKS (single leg) .

Perimeter 1 6 T8 @ 140 102 from col face


Perimeter 2 8 T8 @ 125 256 from col face
Perimeter 3 5 T8 @ 275 410 from col face
Perimeter 4 6 T8 @ 265 564 from col face
Perimeter 5 7 T8 @ 265 717.5 from col face
0 0 0
0 0 0
0 0 0 Plan
0 0 0
REINFORCED CONCRETE
Project Spreadsheets to BS 8110 COUNCIL
Client Advisory Group Made by Date Page
Location An example RE-ENTRANT rmw 08-Dec-2021 34
PUNCHING SHEAR to BS8110:1997 CORNER Checked Revision Job No
Originated from RCC13.xls v2.2 on CD © 1999-2003 BCA for RCC chg - R68

MATERIALS fcu N/mm2 40 STATUS Legend


fyv N/mm2 460 VALID DESIGN
link Ø mm 8

DIMENSION A mm 400 E mm -125


B mm 300 F mm 175
C mm 0 G mm 100
D mm 0 H mm 100

LOADING Vt kN 478.0 Veff = kN 591.6


ult UDL kN/m2 16.10

SLAB h mm 250 dx mm 215 Asx mm2/m 1340


dy mm 195 Asy mm2/m 1340
ave d mm 205 ave As % 0.655

RESULTS Veff = 591.6 kN vc = 0.7588 N/mm2 (Table 3.8)


At col. face, v max = 2.053 N/mm2 At 1.5d perimeter, v = 0.9214 N/mm2
At 2.25d perimeter, v = 0.7015 N/mm2

PROVIDE LINKS (single leg) .

Perimeter 1 6 T8 @ 285 102 from col face


Perimeter 2 9 T8 @ 295 256 from col face
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0 Plan
0 0 0
Project Spreadsheets to BS 8110

Location ECBP Typical Floor Column B3 INTERNAL COLUMN


PUNCHING SHEAR to BS8110:1997 Made by rmw Job No R68
Originated from RCC13.xls v2.2 on CD © 1999-2003 BC Date 8-Dec-21

DETAILED CALCULATIONS
Veff/Vt 1.1500 (enhancement factor) link leg area 78.5
Hole deduction ? YES
CRITICAL PERIMETERS ENCLOSED AREAS
Per No a Internal deduct Final m Per No Internal
1 704.625 7237 712 6525 1 3.263
2 1056.9375 10055.5 1006 9050 2 6.310
3 1409.25 12874 1299 11575 3 10.349
4 1761.5625 15692.5 1593 14100 4 15.381
5 2113.875 18511 1887 16624 5 21.406
6 2466.1875 21329.5 2180 19149 6 28.424
7 2818.5 24148 2474 21674 7 36.435
8 3170.8125 26966.5 2767 24199 8 45.440
Hole face 0 1600 125 1475 Hole face 0.150
Col face 0 1600 125 1475 Col face 0.150

LINK REQUIREMENTS within


Per No v Asv Total No Location Band?
1 1.0886 2799 35.63 1.50 d 0
2 0.7716 3881 49.42 2.25 d 0
3 0.5896 4964 0.00 3.00 d 0
4 0.4699 6047 0.00 0.00 d 0
5 0.3843 7130 0.00 0.00 d 0
6 0.3191 8213 0.00 0.00 d 0
7 0.2674 9296 0.00 0.00 d 0
8 0.2248 10379 0.00 0.00 d 0
Hole face 4.8989
Col face 4.8989

LINK PERIMETERS
Per No a Internal deduct Final m No Spacing
1 234.875 3479 321 3158 15 240
2 587.1875 6297.5 614 5683 21 295
3 939.5 9116 908 8208 29 300
4 1291.8125 11934.5 1202 10733 18 670
5 1644.125 14753 1495 13258 21 695
6 1996.4375 17571.5 1789 15783 25 685
7 2348.75 20390 2082 18308 28 700
8 2701.0625 23208.5 2376 20833 32 690
9 3053.375 26027 2669 23358 36 685
Project Spreadsheets to BS 8110

Location Column B2 EDGE COLUMN


PUNCHING SHEAR to BS8110:1997 Made by rmw Job No R68
Originated from RCC13.xls v2.2 on CD © 1999-2003 BCA for Date 8-Dec-21

DETAILED CALCULATIONS
Veff/Vt 1.4000 (enhancement factor) link leg area 50.3
Hole deduction ? YES
CRITICAL PERIMETERS ENCLOSED AREAS
Per No a Internal Choose m deduct Final m Per No Edge D
1 720 6660 3930 362 3568 1 1.893
2 1080 9540 5370 516 4854 2 3.567
3 1440 12420 6810 635 6175 3 5.759
4 1800 15300 8250 713 7538 4 8.470
5 2160 18180 9690 790 8900 5 11.699
6 2520 21060 11130 867 10263 6 15.447
7 2880 23940 12570 944 11626 7 19.713
8 3240 26820 14010 1021 12989 8 24.497
Hole face 225 2700 1950 150 1800 Hole face 0.438
Col face 0 900 0 900 Col face 0.050

LINK REQUIREMENTS within


Per No v Asv Total No Location Band?
1 0.8025 1564 31.11 1.50 d 1
2 0.5737 2127 42.32 2.25 d 1
3 0.4343 2706 0.00 3.00 d 0
4 0.3389 3303 0.00 0.00 d 0
5 0.2699 3901 0.00 0.00 d 0
6 0.2169 4498 0.00 0.00 d 0
7 0.1743 5095 0.00 0.00 d 0
8 0.1387 5693 0.00 0.00 d 0
Hole face 1.6286
Col face 3.2773

LINK PERIMETERS
Per No a Internal Choose m deduct Final m No Spacing
1 240 2820 2010 156 1853.571 13 165
2 600 5700 3450 311 3139.286 19 180
3 960 8580 4890 465 4425 24 200
4 1320 11460 6330 610 5720.357 10 715
5 1680 14340 7770 687 7083.214 12 705
6 2040 17220 9210 764 8446.071 14 700
7 2400 20100 10650 841 9808.929 16 700
8 2760 22980 12090 918 11171.79 18 695
9 3120 25860 13530 995 12534.64 20 695
Project Spreadsheets to BS 8110

Location Columns A1, D1, A5 & D5 CORNER COLUMN


PUNCHING SHEAR to BS8110:1997 Made by rmw Job No R68
Originated from RCC13.xls v2.2 on CD © 1999-2003 BCA for RCC Date 8-Dec-21

DETAILED CALCULATIONS
Veff/Vt 1.2500 (enhancement factor) link leg area 50.3
Hole deduction ? YES
CRITICAL PERIMETERS
Per No a Internal Edge C Edge D Corner Choose m deduct Final m
1 307.5 3760 2280 2130 1265 1265 288 977
2 461.25 4990 2895 2745 1572.5 1572.5 391 1182
3 615 6220 3510 3360 1880 1880 447 1433
4 768.75 7450 4125 3975 2187.5 2187.5 498 1690
5 922.5 8680 4740 4590 2495 2495 549 1946
6 1076.25 9910 5355 5205 2802.5 2802.5 600 2202
7 1230 11140 5970 5820 3110 3110 652 2458
8 1383.75 12370 6585 6435 3417.5 3417.5 703 2715
Hole face 25 1500 1150 1000 700 700 100 600
Col face 0 650 650 0 650

ENCLOSED AREAS LINK REQUIREMENTS within


Per No Corner Per No v Asv Total No LocationBand?
1 0.394 1 1.659 668 13.3 1.50 d 1
2 0.613 2 1.353 268 5.3 2.25 d 1
3 0.878 3 1.097 268 5.3 3.00 d 1
4 1.191 4 0.912 316 6.3 3.75 d 1
5 1.551 5 0.774 364 0.0 4.50 d 0
6 1.958 6 0.666 412 0.0 0.00 d 0
7 2.412 7 0.578 460 0.0 0.00 d 0
8 2.914 8 0.506 508 0.0 0.00 d 0
Hole face 0.117 Hole face 2.745
Col face 0.100 Col face 2.536

LINK PERIMETERS
Per No a Internal Edge C Edge D Corner Choose m deduct Final m No Spacing
1 102.5 2120 1460 1310 855 855 152 703 6 140
2 256.25 3350 2075 1925 1162.5 1162.5 254 908 8 125
3 410 4580 2690 2540 1470 1470 357 1113 5 275
4 563.75 5810 3305 3155 1777.5 1777.5 430 1348 6 265
5 717.5 7040 3920 3770 2085 2085 481 1604 7 265
6 871.25 8270 4535 4385 2392.5 2392.5 532 1860 8 265
7 1025 9500 5150 5000 2700 2700 583 2117 8 300
8 1178.75 10730 5765 5615 3007.5 3007.5 635 2373 9 295
9 1332.5 11960 6380 6230 3315 3315 686 2629 10 290
Project Spreadsheets to BS 8110

Location An example RE-ENTRANT CORNER COLUMN


PUNCHING SHEAR to BS8110:1997 Made by rmw Job No R68
Originated from RCC13.xls v2.2 on CD © 1999-2003 BCA for R Date 8-Dec-21

DETAILED CALCULATIONS
Veff/Vt 1.2377 (enhancement factor) link leg area 50.3
Hole deduction ? YES
CRITICAL PERIMETERS ENCLOSED AREAS
Per No a Internal Corner deduct Final m Per No Internal Corner
1 307.5 3860 3245 158 3087 1 0.929 0.430
2 461.25 5090 4167.5 144 4023 2 1.617 0.656
3 615 6320 5090 130 4960 3 2.494 0.929
4 768.75 7550 6012.5 116 5896 4 3.560 1.249
5 922.5 8780 6935 103 6833 5 4.816 1.617
6 1076.25 10010 7857.5 89 7769 6 6.260 2.032
7 1230 11240 8780 75 8705 7 7.894 2.494
8 1383.75 12470 9702.5 61 9642 8 9.716 3.003
Hole face 25 1600 1550 109 1441 Hole face 0.158 0.138
Col face 0 1400 0 1400 Col face 0.120

LINK REQUIREMENTS within


Per No v Asv Total No Location Band?
1 0.9214 578 11.49 1.50 d 0
2 0.7015 753 0.00 2.25 d 0
3 0.5637 928 0.00 0.00 d 0
4 0.4689 1104 0.00 0.00 d 0
5 0.3994 1279 0.00 0.00 d 0
6 0.3460 1454 0.00 0.00 d 0
7 0.3037 1629 0.00 0.00 d 0
8 0.2690 1805 0.00 0.00 d 0
Hole face 1.9935
Col face 2.0530

LINK PERIMETERS
Per No a Internal Corner deduct Final m No Spacing
1 102.5 2220 1315 157 1158 6 285
2 256.25 3450 2237.5 163 2074 9 295
3 410 4680 3160 149 3011 12 300
4 563.75 5910 4082.5 135 3947 15 300
5 717.5 7140 5005 121 4884 18 305
6 871.25 8370 5927.5 107 5820 21 305
7 1025 9600 6850 93 6757 24 305
8 1178.75 10830 7772.5 79 7693 28 295
9 1332.5 12060 8695 65 8630 31 295
Disclaimer
All advice or information from the British Cement Association and/or Reinforced
Concrete Council is intended for those who will evaluate the significance and limitations
of its contents and take responsibility for its use and application. No liability (including
that for negligence) for any loss resulting from such advice or information is accepted by
the BCA, RCC or their subcontractors, suppliers or advisors. Users should note that all
BCA software and publications are subject to revision from time to time and should
therefore ensure that they are in possession of the latest version.

This spreadsheet should be used in compliance with the accompanying publication


'Spreadsheets for concrete design to BS 8110 and EC2' available from British Cement
Association, Telford Avenue, Crowthorne, Berkshire RG45 6YS.

Status of spreadsheet This spreadsheet is shareware. It may be distributed


Public release version. freely, but may not be used for commercial purposes until
the user has registered with the RCC.
Revision history RCC13 Punching Shear
Date Version Action Size (kB)
21-Jan-03 RCC13 v2.2 DETR logo replaced by DTI. 402
3-Dec-02 RCC13 v2.1 Fix for error when no holes. 421
11-Oct-02 RCC13 v2.0 Version 2 enhancements 421
27-Feb-02 RCC13 V1.3 Column face perimeter changed on "detail" sheets. 404
Improved routine for perimeter reduction due to
15-Feb-02 RCC13 V1.2 407
adjacent holes.
17-Aug-00 RCC13 v1.1 Red warning if INTERNAL:M14 negative. 310
First public release.
3-Aug-99 RCC13 v1.0 309
Includes b version comments
Size (kB)