SAFETY STANDARDS ACCORDING TO EN 60335-1/EN 60335-2-15
ENCLOSURE
§ Damaged or broken parts of the enclosure, given adequate protection against accidental
contact with live parts, must be replaced.
§ Damaged plugs and/or supply cords must be replaced.
INTERNAL WIRING
§ Keep internal PVC wiring away from the hot surface of the heating elements
§ Wiring of the hotplate elements must be fixed into the grooves of the hotplate support.
§ Creepage distance and clearances between live parts and metal parts shall be not less than
3 mm
EARTH CONNECTION
Accessible metal parts, which may become live in the event of an insulation fault, shall be permanently
and reliable connected to an earthing terminal.
Check the correct operation of switches and heating elements by measuring the resistance of the
appliances, placing the switches in all possible positions.
THERMO-FUSE
TEST EQUIPMENT
It is recommended to check the appliance for electrical safety with a suitable appliance tester.
“Domestic coffeemakers”
April 2007
R
Double Tab
2a 2b
10
9
L N
12
11
3b 4 3a
2a 6
L
2b
N
4 5
47
59
48 62
60
63
49
61 64
50
51 53
52 54
55 65
56
57
66
69
70
71
67
72
73
68
benaming KB 741
R type Moccamaster
datum augustus 2002
getekend Insight illustr. controle
formaat A4 bladnr. 2
tek.nr.
AMERONGEN-HOLLAND
the coffeemaker makers.
59
47A
60
47 61 62
63
48
49 64
50
51 53
52 54
55
56
57
65
37
38
9 39
40
41
42
43
13
46 44
47
14
15 45
10
16
11 17
12 48 49
18 22
19
20 23
21
50
24
26A 25 51
55
56 52
26 58
57
27 59
28 60 53
29 61 54
30
31 55
32 benaming Coffeemaker
R KBG 40.100
type
datum april 2005
getekend DDCom controle
formaat A4 bladnr. 1 van 2
tek.nr.
62
63
65
66 64
67
68
69
benaming Coffeemaker
R KBG 40.100
type
datum april 2005
getekend DDCom controle
formaat A4 bladnr. 2 van 2
tek.nr.
the coffeemaker makers.
1 34
2
35
3
4
5 7 36
6 8
37
38
9 39
40
41
42
43
13
46 44
47
14
15 45
10
16
11 17
12 48 49
18 22
19
20 23
21
50
24
25 51
26A
55
26 52
56 58
57
27 59
28 60 53
29 61 54
30
31 55
32 benaming Coffeemaker
R KBG 40.080
type
datum april 2005
getekend DDCom controle
formaat A4 bladnr. 1 van 2
tek.nr.
62
63
64
67
68
69
65
70
71
66
benaming Coffeemaker
R KBG 40.080
type
datum april 2005
getekend DDCom controle
formaat A4 bladnr. 2 van 2
tek.nr.
the coffeemaker makers.
KB 40 electrical diagram
KB 40 electrical diagram
2
3
5 7
6 8
23
9
24
25
10
11
12
13
14
15
16
26
17
18
27
28
19 R
benaming Coffeemaker CD
type CD-010
datum april 2001
20 22 getekend Insight ill. controle
formaat A4 bladnr. 1
21 tek.nr.
AMERONGEN-HOLLAND
51
29A
52
29
53
54
55
56
30 57
31
32
33 34
35
58
36
37 36
38 32
33
36
39
40
41 50
42
49
48
47
43
46
45
44
benaming Coffeemaker CD
R type CD-010
datum april 2001
getekend Insight ill. controle
formaat A4 bladnr. 2
tek.nr.
AMERONGEN-HOLLAND
the coffeemaker makers.
2 27
3
4
28
5 7
6 8
29
9
10
11 22
12 30
13
23
14
15
16
19 31
32
33
24
17
34
35
25
18 benaming Moccamaster
a R type CDK-8
19 21 (blad 2)
datum januari 2007
20
getekend DDCom controle
formaat A4 bladnr. 1
tek.nr.
AMERONGEN-HOLLAND
64
36A
65
36
66
67
68
69
37 70
38
39
40 41
42
71
43
44
45
a 42
(blad 1)
20
43
46
47 53
48 54
49 55
56
57
50
58
59
60
61
51
62
63
52 R
benaming Moccamaster
type CDK-8
datum januari 2007
getekend DDCom controle
formaat A4 bladnr. 2
tek.nr.
AMERONGEN-HOLLAND
the coffeemaker makers.
2
28
3
5 29
7
6 8
30
9
10
11 23
12 31
13
24
14
15
16
17 32
21
33
25 34
18 35
36
26
benaming Moccamaster
R type CDK-10
21
tek.nr.
AMERONGEN-HOLLAND
65
37A
66
37
67
68
69
70
38 71
39
40
41 42
43
72
44
45
46
a 43
(blad 1)
21
44
47
48 54
49 55
50 56
57
58
51
59
60
61
62
52
63
64
53 R
benaming Moccamaster
type CDK-10
datum januari 2007
getekend DDCom controle
formaat A4 bladnr. 2
tek.nr.
AMERONGEN-HOLLAND
the coffeemaker makers.
24
25
26
benaming RC1 cf
R type
datum september 2001
getekend Insight ill. controle
formaat A4 bladnr. 1
tek.nr.
AMERONGEN-HOLLAND
R
24
25
26
benaming RC2 cf
R type
datum september 2001
getekend Insight ill. controle
formaat A4 bladnr. 1
tek.nr.
AMERONGEN-HOLLAND
R
3
4
5
8 6
9
10
11 7
12
13
14
15
16 10
17 11
18 21
19
20 22
22 14
23 12
25
26
22
27
24
28
37
29
30 36
35
34
31
32
33
benaming Rechaud CD
R type
datum april 2001
getekend Insight ill. controle
formaat A4 bladnr. 1
tek.nr.
AMERONGEN-HOLLAND
R
service announcement
Thermostat 46200 and thermo-fuse 43510 are replaced
by thermostat/thermofuse combination code number 46265,
starting with production code 0601
Reason:
In the old situation the thermostat and thermo-fuse are located on different position,
temperature rising on both position are not equal.
Result: the thermostat protects the heating element depending on the temperature at the location
of the thermostat.
The temperature on the thermo-fuse is totally different and can reach peak temperature
close or even over the trip temperature of the thermo-fuse.
Improvement:
In the situation with the new thermostat in combination with the thermo-fuse, the temperature of
both thermostat and thermo-fuse is the same, so the thermostat is not only protecting the boiler
but in fact also the thermo-fuse.
The trip-temperature of the thermo-fuse is 260°C and the trip-temperature of the thermostat is 145°C
the difference in trip-temperature is necessary to handle overshoots in temperature.
The thermo-fuse will trip only in case the thermostat fails.
Machines with the new boilers can be identified by the " /A " added to the type number on the
machine label
Example: type 741.65 will be chanced into 741.65/A, when the new boiler with the
thermostat/thermo-fuse combination is installed.
Mod.nr. 004
Amerongen Date: November 2001
service announcement
Replacing old type boiling element by a new boiling element
The old type boiling element, with a seperated thermostat and thermo-fuse unit, can be replaced
by the new type boiling element with thermostat/thermo-fuse combination,
simply by connecting 2 wires code 40450 to thermo-fuse section of the combination as indicated in the figure
1310W
240V
Mod.nr. 005
Amerongen Date: January 2002
fig. 1 fig. 2
Instruction:
Remove old element and fixation parts fig. 1 and replace new PTC element according to fig. 2
E
A red
41720 blue
blue
B D
E A
red C
D
41748 blue
blue
cut D
blue wire
this wire must be used to
connect the boiler and the boiler
float switch
A black brown
blue
D B
E 41233 C
E
A red
41720 red
blue
B D
C
C
E B
D red
41747 red
boiler blue
A black brown
blue
D B
E 41234 C
E F
A red
41720 blue
blue
B D
A black brown
blue
D B
41239 C
F
E
D E
A red
blue
blue 41720
B C
A black brown
blue
C B
41235
E
D
D B
C red
41747 blue
blue
boiler A
A black brown
blue
C B
D 41236
E B
red C
D
41748 red
blue
cut A
blue wire
this wire must be used to
connect the boiler and the boiler
float switch
A black brown
blue
D B
E 41233 C
KB 742
typ: rated power old hotplate elem. new hotplate elem.
742.05 1320W/230V 41700 right 41215 HP 05
742.06 left 41216 HP 05
A
41700
RIGHT
B
B
41215 right hotplate
C
C
A
41700
LEFT
B
C
A
B
41216 left hotplate
KB 742
742.20 1440W/240V 41700 right 41217 HP 05
742.25 41700 left 41216 HP 05
742.30 1570W/230V 41700 right 41217 HP 05
742.35 41700 left 41216 HP 05
A
41700
RIGHT
B
B
41217 right hotplate
C
C
A
41700
LEFT
B
C
A
B
41216 left hotplate
KB 743
typ: rated power old hotplate elem. new hotplate elem.
743.01 2060-2550W/230V 41720 41240 HP 07
743.02
E
A red
41720 blue
blue
B D
A black brown
blue
D B
41240 C
E
KB 743
typ: rated power old hotplate elem. new hotplate elem.
743.05 2060-2550W/230V 41720 41237 HP 07
E
A red
41720 blue
blue
B D
A black brown
blue
D B
41237 C
E
KB 744
typ: rated power old hotplate elem. new hotplate elem.
744.01 2060-2550W/230V 41721 41238 HP 07
744.02
744.05 2550W/230V 41721 41238 HP 07
744.06
744.11 3040W/230V 41721 41238 HP 07
744.12
A red
41720 blue
blue
B C
A black brown
blue
C B
41238
RC-1
typ: rated power old hotplate elem. new hotplate elem.
60W/230V 41702 41214 HP 05
80W/230V 41710 41214 HP 05
73W/230V 41810 41214 HP 05
C
A
C
A
B
41214
RC-2 LEFT
typ: rated power old hotplate elem. new hotplate elem.
60W/230V 41702 left 41214 HP 05 left
80W/230V 41710 ,, 41214 HP 05 ,,
73W/230V 41810 ,, 41214 HP 05 ,,
C
A
C
A
B
41214
RC-2 RIGHT
typ: rated power old hotplate elem. new hotplate elem.
60W/230V 41702 right 41213 HP 05 right
80W/230V 41710 ,, 41213 HP 05 ,,
73W/230V 41810 ,, 41213 HP 05 ,,
C
A
C
A
B
41213
KB 851
typ: rated power old hotplate elem. new hotplate elem.
1260W/230V 41701 41211 HP 05
C
A
C
A
B
41211
KB 851
typ: rated power old hotplate elem. new hotplate elem.
1260W/230V 41701 41212 HP 05
1375W/240V 41701 41212 HP 05
C
A
C
A
B
41212
service announcement
The illuminated switch code: 43048, 43044, 43058 (black, white, brown) will be replaced
by illuminated switch: 43035, 43036, 43037 (black, white, brown).
Reason:
After recieving complains about broken switches, we found a replacement for the old switch.
The new switch, Arcolectric type C6003, is splashproof, rated 16(4)A 250V T125
ATTENTION:
The illuminated lens of the new switch must be in the opposite direction as the old switch.
Electrical connections are similar.
ATTENTION:
The illuminated lens of the new switch must be in the opposite direction as the old switch.
Type: 851
Type: RC 1 and RC 2
Attention: Old switch 43018 and 43048 will be replaced by new switch 43035
43048 43035
43018 43035
Reason:
In the old situation the thermostat and thermo-fuse are located on different position,
temperature rising on both position are not equal.
Result: the thermostat protects the heating element depending on the temperature at the location
of the thermostat.
The temperature on the thermo-fuse is totally different and can reach peak temperature
close or even over the trip temperature of the thermo-fuse.
Mod.nr. 011
TECHNIVORM BV Date: April 2004
Amerongen
service announcement
Replacement for switch 43002 in CD-010
The switch 43002 is replaced by switch 43004
Reason:
New switch with illuminated actuators to improve the indication of the switch.
ATTENTION:
The new switch has a fixed wire (white) with connected-on bent tab to allow the connection
of two receptacles on one connection point.
All connection points of the new switch must be insulated! (Insulation sleeve code 46085)
5. Remove the blue wire, connected to the block terminal, from the float switch.
6. Join this bue wire together with the fixed"white" wire from the new switch
service announcement
Screw M4 x 6, 71017
Amerongen
service announcement
Boiling element 45148, 1450W/230V, will be replaced by boiling element 45149 1450W/230V
Boiling element 45150, 1310W/240V, will be replaced by boiling element 45163 1310W/240V
Reason:
Standardization of boiling elements and the introduction of new models in the "CD" series.
Difference:
The positon of the cold water inlet tube has been changed.
Benefits:
Reduction of spare-parts
Attention:
To replace the old type boiling element 45148 and 45150, it is necessary to replace the wire
connecting the float-switch and the thermostat/thermo-fuse by wire 40414 (lenght 200mm)
14 50W
230V
Wiring Boiler 45149 and 45163 Wiring boiler 45113 for "CD" type,
for "CD" type 1400W/120 V
tek.nr. EV KM/DOS
.
the coffeemaker makers.
KM 4 electrical diagram
tek.nr. EV DOS
.
the coffeemaker makers.
“Professional coffeemakers”
April 2007
1
8
4 9
5 6 11
2A
7
2B
14 4
15
17 23
14
15
20
19
16
18
27
26 18
19
benaming Aquaserver
R type Manual
datum 02-10-2002
getekend Insight ill. controle
formaat A4 bladnr. 1
tek.nr.
AMERONGEN-HOLLAND
39 35
36
42
33
32
31
41
43
34
44
45
44
52
74
51
46
47
54 48
56 57 62
67 67 69
71 63
50 67
55 58
65
66
53 72
64
73
60
59
65 47
benaming Aquaserver
R type Manual
datum 02-10-2002
getekend Insight ill. controle
formaat A4 bladnr. 3
tek.nr.
AMERONGEN-HOLLAND
R
24
28
8 22
4 9
5 6 11
2A
7
2B 12 13 10
14 4
15
17 23
14 30
15
20 29
30
9
23
9 25
3
21
16
8
27
26 18
19
benaming Aquaserver
R type Autofill
datum 02-10-2002
getekend Insight ill. controle
formaat A4 bladnr. 1
tek.nr.
AMERONGEN-HOLLAND
113
76 114
77
77 112
76
111
115
81 88
116
80 134
79 93
107
76
78 92
123 128
76 66
84
85 121 84
82 84
83 71 91 9
133 15 125
14
125 127 94
106
40 90
3 132 95 122 104
120
86 95 102
117 129
89 97
103
130
87 131
119
99
101
100
benaming Aquaserver
R type Autofill
datum 02-10-2002
getekend Insight ill. controle
formaat A4 bladnr. 2
tek.nr.
AMERONGEN-HOLLAND
39 35
36
42
33
32
31
41
43
34
44
45
44
52
74
51
46
47
59
54 48
56 57 62
67 67 69
63 61
71
50 67
55 58
65
66
53 72
64 70
73
60
59
65 47
benaming Aquaserver
R type Autofill
datum 02-10-2002
getekend Insight ill. controle
formaat A4 bladnr. 3
tek.nr.
AMERONGEN-HOLLAND
R
12
13
2
3
5
4 6
14
15 7
3
16 4
10
11
9
8 8
53
20
34 29
30
31
32 54 60
33
32 55
37 56 62
44
38 35 54
26 63
37 57
38
37
43
44
45
39
48
38
50 37
38
benaming Moccafour
R type Manual
datum 02-10-2002
getekend Insight ill. controle
formaat A4 bladnr. 1
tek.nr.
AMERONGEN-HOLLAND
10
72
73
98 70
71
97
82
100
83
84
89
85
88
91
86
96 87
93
31
99
benaming Moccafour
R type Manual
datum 02-10-2002
getekend Insight ill. controle
formaat A4 bladnr. 2
tek.nr.
AMERONGEN-HOLLAND
101
12
13
14 102
17
16 120
5
31
32 6
33 113
32 114
115
111
109
119
116
117
129 118
128
29
95
124
56
126
95
127
56
121 45
124
114
95
113
benaming Moccafour
R
8 type Manual
datum 02-10-2002
getekend Insight ill. controle
formaat A4 bladnr. 3
tek.nr.
AMERONGEN-HOLLAND
R
13 1
14
15 2
3
5
16
21 4 6
22 7
23 3
24 4
4 10
26 11
27
28 9
8 8
53
20
34 29
30 60
31
32 62
54
36 33
32 55
37 56 63
44
38 35 54
36 26
37 57
38
37
43
44
45
39
48
38
50 37
38
benaming Moccafour
R type Autofill
datum 02-10-2002
getekend Insight ill. controle
formaat A4 bladnr. 1
tek.nr.
AMERONGEN-HOLLAND
66
67
10
72
68
73
69
98 70
71
77
78
104 78
97 27
79
82
80
100
83
84
89
85
88
91
86
96 87
93
31
99
benaming Moccafour
R type Autofill
datum 02-10-2002
getekend Insight ill. controle
formaat A4 bladnr. 2
tek.nr.
AMERONGEN-HOLLAND
103
101 104
105 112
12
13
106
107
108
14 102
17 104
16 120
5 110
31
6
32
33 113
32 114
115
111
109
119
116
117
129 118
128
29
121
95 122 122
124
56
126
95
127
56
45 123
124 95
114
95
125
113
benaming Moccafour
R
8 type Autofill
datum 02-10-2002
getekend Insight ill. controle
formaat A4 bladnr. 3
tek.nr.
AMERONGEN-HOLLAND
R
benaming Moccaking
R type
datum 21 - 06 - 02
getekend controle
formaat A4 bladnr. 1
tek.nr. EV 0011 MK-1
AMERONGEN-HOLLAND
benaming Moccaking
R type
datum 21 - 06 - 02
getekend controle
formaat A4 bladnr. 2
tek.nr. EV 0011 MK-2
AMERONGEN-HOLLAND
benaming Moccaking
R type
datum 21-06-02
getekend controle
formaat A4 bladnr. 3
tek.nr. EV 0011 MK-3
AMERONGEN-HOLLAND
6
125
103
benaming Moccaking
R type
datum 21-06-02
getekend controle
formaat A4 bladnr. 4
tek.nr. EV 0011 MK-4
AMERONGEN-HOLLAND
R
21
39
26
benaming Moccaserver
63 R type
datum 21-06-02
getekend controle
64 formaat A4 bladnr. 1
tek.nr. EV 0011 MS-1
AMERONGEN-HOLLAND
benaming Moccaserver
R type
datum 21-06-02
getekend controle
formaat A4 bladnr. 2
tek.nr. EV 0011 MS-2
AMERONGEN-HOLLAND
37
105
39
benaming Moccaserver
R type
datum 21-06-02
getekend controle
formaat A4 bladnr. 3
tek.nr. EV 0011 MS-3
AMERONGEN-HOLLAND
R
double tab
93
E
A
B
blue
brown
105
C
E
65b
65a
58
brown
brown
F
B
17
brown
G
white
65b
58
A
100
17
65a
105
93
N
L
16
7
17
20
18 21
1 19
18 22
46 23
9
8
10
11 24
13
47 12 25
14
31
48 30
50 34
49 44
45
benaming Moccastar
R type
datum 02-10-2002
getekend Insight ill. controle
formaat A4 bladnr. 1
tek.nr.
AMERONGEN-HOLLAND
51
52 60
62
53
61
54
63
55
64
45
80
59
44 65
45
66
68
67
69
70
72 71
35
73 36
38 37
41 38
76
77 39
74
78
79 75
75
benaming Moccastar
R type
datum 02-10-2002
getekend Insight ill. controle
formaat A4 bladnr. 2
tek.nr.
AMERONGEN-HOLLAND
R
INTERNAL WIRING:
090 White, 400mm ................................................................................................... 40050
091 Brown, 380mm .................................................................................................. 40060
092 Assembly wiring MS 051/B, 380mm (40060) + 380mm (40060)
093 Assembly wiring MS 051/B, 380mm (40060) + 380mm (40060)
094 Brown, 380mm .................................................................................................. 40064
095 Blue, 100mm ..................................................................................................... 40425
096 Blue, 400mm ..................................................................................................... 40420
N
L
INTERNAL WIRING:
080 Signal lamp (ORANGE), assembly MS 075 ...............................................................
Signal lamp (RED), assembly MS 076 .......................................................................
091 Brown, 125mm .................................................................................................. 40002
092 Brown, 200mm .................................................................................................. 40022
093 Blue, 100mm ..................................................................................................... 40425
094 Blue, 400mm ..................................................................................................... 40420
095 Brown, 200mm .................................................................................................. 40022
096 Brown, 380mm .................................................................................................. 40064
82
benaming Thermoking
R type met stootstrip
datum 08 - 11 - 00
getekend controle
formaat A4 bladnr. 4
tek.nr. EV 0011 TK-4
AMERONGEN-HOLLAND
R
INTERNAL WIRING:
090 White, 400mm ................................................................................................... 40050
091 Brown, 380mm .................................................................................................. 40060
092 Assembly wiring TK 010/A, 380mm (40060) + 125mm (40002)
093 Assembly wiring TK 010/A, 380mm (40060) + 600mm (40080)
094 Brown, 540mm .................................................................................................. 40075
095 Blue, 100mm ..................................................................................................... 40425
096 Blue, 400mm ..................................................................................................... 40420
N
L
42b
37
blue
3
26
orange
green
grey
white
purple
14
31
red
blue
42a
81
red
80
brown
blue
N
42b
37
29
14
42a
81
80
42b
orange
37
29
blue
26
orange
3
green
grey
white
purple
14
31
red
blue
42a
81
red
80
brown
blue
N
2
7
8 3
18
9
5
6
19
25 20
21
26
40
28
29
30 41
33
31 36 42
37
38
32
39
34
35 41
54
55
63
64
65
49
66
52
56
67
97 68 57
69
98 70 58 81
69 82
60 83
80
99 61 59
91
84
92 85
100 93 86
94 87
95 88
96 89
90
102
114
103
113
105
106
104
128 110
129 111 107
130
131
132 108
112 109
133
121 117
134
135 118
136 119
137
122 120
123
138
124
125
127
81b
80
blue
blue
99
81a
orange
61
red
26
blue
brown
N
L
28
81b
80
29
99
81a
61
26
N
L
2
7
8 3
10
11
12
13
18 5
6
14
25 19 15
20 16
26
21 17
27 40
28
29
30 41
33
31 36 42
37
38
32
39
34
35 41
46 53
54
47
55
63
48
64
65
49
66
71
72 76
74
52 75
73
56
67
97 68 57
69
98 50 70 58 81
69 82
51 60 83
80
99 61 59
91
84
85
100 93 86
94 87
95 88
96 89
90
102
114
103
113
105
106
104
128 110
129 111 107
130
131
132 108
112 109
133
116
121 117
134
135 118
136 119
137 115
122 120
123
138
124
125
127 126
28
white
white
81b
80
blue
blue
black
29
81a
129
black
27
73
orange
autofill
2
system
N
61
PCB
115
1
A
C
sensor wires 40460
26
red
brown
blue
N
L
service announcement
Modification of older machines by means of extra wires 40420 and 40425 according to diagram.
Mod.nr. 001
Amerongen Date: October 2000
service announcement
Boiling element 2200W/240V code: 45200 - 45201
Boiling element 2200W/230V code: 45205 - 45206
Boiling element 3000W/240V code: 45220
Thermostat 46200 and thermo-fuse 43540 are replaced by thermostat/thermofuse combination
46260, starting with production code 0003000.
Modification of older machines by means of extra wires 40420 and 40425 according to diagram.
Mod.nr. 001A
Amerongen Date: March 2000
service announcement
Old containers can be replaced without any problems, "O"- ring (pos. E) and nut PG 21 (pos. F) are
no longer required.
fig. 1 fig. 2
Instruction:
Remove old element and fixation parts fig. 1 and replace new PTC element according to fig. 2
black brown
blue
B 41260
B
41265
B
41266
A
41270
B
B
41265
B
41265
B
41266
B
41265
B
41265
B
41265
B
41266
service announcement
Attention:
When the old sensor must be replaced it is neccassary to change also the printed circuit board
48010 or 48015
The new sensor has a bigger diameter and another sealing, so the hotwatercontainer must be
modified or replaced by a new type 11068/A
Instruction :
1. Remove the nut (2), the old sensor (4) and the
rubber sealing ring (3) from the container
2. Increase the diameter of the fixing hole to 12 mm
by drilling a bigger hole, or replace the container (1)
by a new type 11068/A
3. Insert the new rubber grommet (5) in the fixing hole.
4. Push the new sensor (6) through the grommet
into the container
5. Connect the wires in the block terminal
6. Replace the old PCB 48010 or 48015
by a new PCB 48010/A or 48015/A
Mod.nr. 008
TECHNIVORM BV Date; June 2004
Amerongen
service announcement
The illuminated switch code: 43048 (black) for:
TSIIXE, Moccaserver, Moccastar Thermo, will be replaced
by illuminated switch: 43035 (black) .
Reason:
After recieving complains about broken switches, we found a replacement for the old switch.
The new switch 43035, Arcolectric type C6003, is splashproof, rated 16(4)A 250V T125
Approvals: European ENEC 15, UL file E45221, CSA file LR10990
ATTENTION:
The illuminated lens of the new switch must be in the opposite direction as the old switch.
Electrical connections are similar.
ATTENTION:
The illuminated lens of the new switch must be in the opposite direction as the old switch.
Electrical connections are similar.
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
CONTENTS:
Discription: page
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
Discharge valve
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
Inner tank
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
- Switch of the machine by means of the main switch, drain the machine by pressing the refresh button “R”.
- Disconnect the machine from the power supply and remove the old outlet valve.
- Remove breather tube from the old valve and insert the tube in the new valve.
- Install the new valve and turn the regulator screw fully clockwise.
- Check the drain hose, ensure that the hose is not flattened or bent.
- Connect the machine to the power supply, and switch on the machine.
- Select the quantity of the new valve and press the start button “S”.
Switch the machine “OFF” after 1 min. by means of the main switch.
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
TIMER/TEMPERATURE ADJUSTMENTS
Adjustment water delivery time
Adjustment is made on the printed circuit board TEC 100 by means of potentiometer P1
Temperature adjustment
Temperature is adjusted at 96°C
Temperature can be adjusted between 92°C and 98°C by means of the knob on the housing of the
printed circuit board.
• Replace knob (screw up) and turn point in the position 96°C
• When the brewing is finished, the water temperature is adjusted by means of P3 at 96°C
• When the brewing is finished and the water reaches 92°C, P2 must be adjusted until relay M2 is
switched off.
• Remove the knob in the position 92°C, replace the cover of the housing and fixed the knob in the
position 92°C
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
Time adjustment is made by potentiometer P1 on the printed circuit board “TEC 110”, behind the
control panel.
• As soon as the machine is producing steam in the jug (bucket), the pressure sensor is turned
counter clockwise until the machine is switched off
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
thethe
coffeemaker
coffeemaker
makers.
makers.
AMERONGEN
AMERONGEN
- HOLLAND
- HOLLAND
service announcement
Attention:
When the old sensor must be replaced it is neccassary to change also the printed circuit board 48000
The new sensor has a bigger diameter and another sealing, so the hotwatercontainer must be modified
Instruction :
1. Remove the nut (2), the old sensor (4) and the
rubber sealing ring (3) from the container
2. Increase the diameter of the fixing hole to 12 mm
by drilling a bigger hole
3. Insert the new rubber grommet (5) in the fixing hole.
4. Push the new sensor (6) through the grommet
into the container
5. Connect the wires in the block terminal
6. Replace the old PCB 48000 by 48000/A
Mod.nr. 009