AGING OF POLYURETHANE FOAM INSULATION IN
SIMULATED REFRIGERATOR PANELS — TWO-YEAR
RESULTS WITH THIRD-GENERATION BLOWING AGENTS
Kenneth E. Wilkes, W. Alex Gabbard, and cyclopentane. Tests with these third-generation blowing
Fred J. Weaver agents started in the fall of 1997 and are planned to continue
Oak Ridge National Laboratory J. Richard Booth
P.O. Box 2008 Department of Chemical Engineering
Oak Ridge, Tennessee 37831-6092 Tennessee Technological University
Cookeville, Tennessee 38505
ABSTRACT
Laboratory data are presented on the effect of constant- for the next few years. Results on full-thickness specimens
temperature aging on the apparent thermal conductivity of after aging at controlled temperatures for six months and for
polyurethane foam insulation for refrigerators and freezers. one year have been reported previously [3,4]. This paper
The foam specimens were blown with HCFC-141b and with presents results after two years of aging.
three of its potential replacements — HFC-134a, HFC-
245fa, and cyclopentane. Specimens were aged at constant SPECIMENS
temperatures of 90°F, 40°F, and -10°F. Thermal
conductivity measurements were made on two types of Two types of specimens are being studied. Specimens of
specimens: full-thickness simulated refrigerator panels one type were fabricated as panels that simulate the
containing foam enclosed between solid plastic sheets, and construction of a door or wall of a refrigerator. The panels
thin slices of core foam cut from similar panels. Results are are about two inches thick and have lateral dimensions of 24
presented for the first two years of a multi-year aging study. inches by 24 inches. The faces of the panels are bounded by
Preliminary comparisons of measured data with predictions solid sheets. For the previous study of second-generation
of a mathematical aging model are presented. blowing agents, the solid sheets consisted of 24 gauge (0.024
in. thick) steel on one side and 0.12 in. thick acrylonitrile-
INTRODUCTION butadiene-styrene (ABS) plastic on the other side [1,2]. For
the present study of third-generation blowing agents, 0.040
Polyurethane foam insulation currently used in in. thick plastic sheets were used on both faces, with separate
refrigerators and freezers in the United States is blown sets of panels being made with ABS and high-impact-
primarily with HCFC-141b. Because of its potential for polystyrene (HIPS) plastic. The thinner plastic was
depleting the ozone layer, the Montreal Protocol mandates considered to be more representative of current refrigerator
that domestic production of HCFC-141b cease by the end of production, and plastic was used on both sides to accelerate
2002, requiring that a replacement blowing agent be used the aging experiments by allowing gases to permeate
after that time. Since 1993, the Oak Ridge National through both sides of the panels. It was felt that the effect of
Laboratory has been cooperating with the Appliance a steel sheet on one side could be simulated using models
Research Consortium on studies of the aging characteristics that are being developed. The edges of the panels were
of polyurethane insulation foamed with various blowing sealed with aluminum foil tape to simulate the configuration
agents. The early studies were aimed at the replacement for in a refrigerator where there are no comparable cut exposed
CFC-11, and results of aging studies on simulated foam edges.
refrigerator panels blown with CFC-11, HCFC-141b, and a The panels were foamed with HCFC-141b (to provide the
blend of HCFC-142b and HCFC-22 have been reported base case), HFC-245fa, HFC-134a, and cyclopentane. At the
previously [1,2]. A long-term study is currently underway present time, the latter two blowing agents are the only
on aging of foam blown with HCFC-141b and several commercially available non-ozone-depleting replacements
potential replacements — HFC-134a, HFC-245fa, and for HCFC-141b, but committments have been made to
construct a plant to produce HFC-245fa. Commercial A.
availability of HFC-245fa is expected in mid-2002. The
panels were fabricated by four foam suppliers (denoted here RESULTS AND DISCUSSION
as suppliers A, B, C, and D), with each supplier providing
panels with each of the four blowing agents. Core-Foam Specimens
To provide a characterization of the foam itself, specimens
were also made that consisted of core foam cut into 12 in. The thermal conductivity of freshly sliced foam at 75°F is
squares and sliced into thicknesses of about 0.4 and 1.5 shown in Table 1 for the two slice thicknesses. This shows
inches. A stack of four of the 0.4-in.-thick slices made up that the lowest thermal conductivity was found with HCFC-
one test specimen. 141b, followed by HFC-245fa (4% higher), cyclopentane
It should be noted that the foams made with the alternative (13% higher), and HFC-134a (21% higher). This relative
blowing agents may not yet be optimized for thermal ranking is the same as has been observed by Haworth [6].
performance. Visual observations of the sliced specimens Table 1 also shows that the thermal conductivity of thinner
showed a very uniform fine cellular structure with HCFC- slices was consistently 3 to 4% higher than that of the
141b but the presence of many larger bubbles interspersed thicker slices. This is at least partly due to the larger
within the fine cellular structure for the other blowing amount of damaged surface layers with the thinner slices
agents. where air immediately displaces the blowing agent in the cut
cells. While the data for the thicker slices are more
EXPERIMENTAL PROCEDURES representative of that in the full-thickness panels, the thinner
specimens age much more rapidly and are useful for
Thermal resistance measurements were made using heat- comparing potential differences in long-term performance
flow-meter-apparatuses (HFMAs) that conform to ASTM C with the different blowing agents.
518 [5]. Intervening layers of foam rubber were placed Figure 1 compares the aging characteristics of the thinner
between the panel specimens and the hot and cold plates of (0.4 in.-thick) slices with the four blowing agents for three
the apparatus to eliminate any undesirable air gaps between aging temperatures and for the two test temperatures. The
the specimens and the plates and also to protect the plates data were taken over a period of about two years. Since
from the rigid test panels. Thermocouples were taped numerous previous studies have shown that the aging of
directly to the faces of the panels so that the temperature unfaced foam scales with the square of the thickness (see [3]
differences across the test panels were measured directly. and ASTM C 1303 [7]), the data are plotted as thermal
Since the measurements gave the overall thermal resistance conductivity versus the aging time divided by the square of
of the center of the test panel, a small correction (< 1%) was the slice thickness. With this scaling, data obtained over a
made for the thermal resistance of the plastic sheets to obtain time period of two years on slices 0.4 in. thick are good
the apparent thermal conductivity of the foam insulation. predictors of the variation of the thermal conductivity of
Tests on the core foam specimens gave the apparent thermal unfaced 2 in.-thick specimens over a period of 50 years, well
conductivity directly. beyond the nominal refrigerator lifetime of 20 years.
The specimens were stored in closed, constant The curves in Figure 1 show several trends. For all
temperature, atmospheric pressure aging chambers between conditions, the curves show an initial rapid increase in
HFMA tests. Aging temperatures of 90°F, 40°F, and -10°F thermal conductivity which is attributed to diffusion of air
were used in order to span most of the range of conditions to components into the cells of the foam, followed by a more
which the foam would be exposed in a refrigerator gradual increase which is attributed to diffusion of the
application. Thermal tests were performed at 45°F and 75°F blowing agent out of the cells. Except for crossover of some
mean temperatures, using a temperature difference of 40°F. of the curves for HCFC-141b and HFC-245fa, the relative
Thermal measurements were made on the full-thickness ranking of blowing agents given in Table 1 is preserved
panels soon after their fabrication and then at six-month throughout the aging process. The time required for a given
intervals. Since the slices of core foam aged much more change in thermal conductivity with aging at 40°F is roughly
rapidly than the full-thickness panels, more frequent thermal twice as long as for aging at 90°F, while the time required
measurements were required. This limited the number of at -10°F is about 10 times as long as at 90°F. The curves for
core-foam specimens that could be studied, and core-foam tests at 45°F and 75°F mean temperatures show the same
measurements were concentrated on specimens from
Supplier
0.18 0.18
0.16 0.16
HCFC-141b HCFC-141b
0.14 HFC-134a 0.14 HFC-134a
HFC-245fa HFC-245fa
Cyclopentane Cyclopentane
0.12 0.12
0 2 4 6 8 10 12 14 0 2 4 6 8 10 12 14
0.22 0.22
Thermal Conductivity, Btu•in./h•ft²•°F
0.18 0.18
0.16 0.16
HCFC-141b
HCFC-141b
HFC-134a
0.14 0.14 HFC-134a
HFC-245fa
HFC-245fa
Cyclopentane
Cyclopentane
0.12 0.12
0 2 4 6 8 10 12 14 0 2 4 6 8 10 12 14
0.22 0.22
Thermal Conductivity, Btu•in./h•ft²•°F
0.20 0.20
0.18 0.18
0.16 0.16
HCFC-141b HCFC-141b
0.14 HFC-134a 0.14 HFC-134a
HFC-245fa HFC-245fa
Cyclopentane Cyclopentane
0.12 0.12
0 2 4 6 8 10 12 14 0 2 4 6 8 10 12 14
four different suppliers. For example, the panels blown with in Figure 3b as aging progresses.
HCFC-141b have pre-aging normalized conductivities at Figure 4 shows percentage increases in thermal
75°F that range from 0.95 to 1.04, but for a given supplier conductivity after two years of aging. The values were
obtained by averaging the percentage increases for the four included in the average). Also shown for comparison are the
suppliers (except for HFC-245fa with HIPS at -10°F, where percentage increases for 2 in.-thick core foam. The values
the anomalously high values for Supplier B were not at
Figure 2. Average normalized thermal conductivity for full-thickness panels before aging. Data are normalized with respect to
average for HCFC-141b tests at 75°F before aging.
1.30 1.20
Normalized Thermal Conductivity
Supplier A Supplier A
1.25 Supplier B 1.15 Supplier B
Supplier C Supplier C
1.20 Supplier D 1.10 Supplier D
1.15 1.05
1.10 1.00
1.05 0.95
1.00 0.90
0.95 0.85
0.90 0.80
HCFC-141b HFC-134a HFC-245fa Cyclopentane HCFC-141b HFC-134a HFC-245fa Cyclopentane
Aging
Blowing Temp., Tested at 75°F Tested at 45°F
Agent Liner °F Supplier A Supplier B Supplier C Supplier D Supplier A Supplier B Supplier C Supplier D
0 Yr. 1 Yr. 2 Yr. 0 Yr. 1 Yr. 2 Yr. 0 Yr. 1 Yr. 2 Yr. 0 Yr. 1 Yr. 2 Yr. 0 Yr. 1 Yr. 2 Yr. 0 Yr. 1 Yr. 2 Yr. 0 Yr. 1 Yr. 2 Yr. 0 Yr. 1 Yr. 2 Yr.
HCFC-141b ABS 90 1.01 1.06 1.13 0.95 1.00 1.06 1.03 1.09 1.17 1.04 1.09 1.16 0.94 0.97 1.03 0.90 0.92 0.99 0.93 0.98 1.05 0.95 0.99 1.06
HCFC-141b ABS 40 1.01 1.04 1.06 0.95 1.00 1.04 1.01 1.07 1.12 1.03 1.08 1.11 0.94 0.93 0.95 0.91 0.90 0.94 0.92 0.95 0.99 0.95 0.96 0.99
HCFC-141b ABS -10 1.01 1.02 1.03 0.95 0.96 0.97 1.02 1.06 1.06 1.04 1.05 1.06 0.94 0.93 0.93 0.89 0.88 0.88 0.93 0.93 0.93 0.95 0.94 0.94
HCFC-141b HIPS 90 1.01 1.13 1.21 0.95 1.06 1.13 1.01 1.18 1.25 1.02 1.19 1.26 0.94 1.04 1.11 0.90 0.99 1.06 0.93 1.07 1.13 0.94 1.10 1.16
HCFC-141b HIPS 40 1.00 1.06 1.11 0.95 1.01 1.06 1.01 1.13 1.18 1.03 1.11 1.20 0.94 0.97 1.01 0.90 0.92 0.97 0.93 1.02 1.06 0.94 1.02 1.09
HCFC-141b HIPS -10 1.01 1.03 1.03 0.95 0.95 0.97 1.01 1.07 1.08 1.02 1.05 1.07 0.94 0.94 0.95 0.90 0.88 0.88 0.93 0.96 0.96 0.94 0.95 0.96
HFC-134a ABS 90 1.21 1.26 1.33 1.17 1.23 1.28 1.17 1.25 1.31 1.18 1.25 1.31 1.09 1.13 1.20 1.07 1.11 1.17 1.06 1.12 1.18 1.08 1.13 1.19
HFC-134a ABS 40 1.20 1.23 1.28 1.14 1.19 1.21 1.17 1.24 1.27 1.19 1.23 1.26 1.09 1.10 1.13 1.04 1.05 1.07 1.07 1.10 1.12 1.08 1.10 1.12
HFC-134a ABS -10 1.21 1.22 1.24 1.16 1.18 1.18 1.18 1.22 1.22 1.18 1.22 1.23 1.09 1.09 1.10 1.05 1.06 1.06 1.07 1.09 1.07 1.08 1.10 1.09
HFC-134a HIPS 90 1.20 1.33 1.40 1.15 1.28 1.33 1.19 1.33 1.39 1.17 1.30 1.37 1.09 1.21 1.27 1.04 1.16 1.22 1.08 1.20 1.27 1.07 1.19 1.24
HFC-134a HIPS 40 1.21 1.27 1.32 1.14 1.20 1.25 1.18 1.27 1.30 1.18 1.24 1.28 1.09 1.13 1.18 1.04 1.07 1.13 1.08 1.13 1.16 1.08 1.11 1.14
HFC-134a HIPS -10 1.21 1.23 1.26 1.17 1.21 1.21 1.19 1.24 1.25 1.19 1.22 1.23 1.09 1.10 1.12 1.07 1.08 1.08 1.07 1.10 1.11 1.08 1.09 1.09
HFC-245fa ABS 90 1.06 1.10 1.14 1.04 1.07 1.12 1.07 1.12 1.18 1.09 1.13 1.18 0.97 0.98 1.04 0.95 0.96 1.01 0.97 1.00 1.06 0.99 1.02 1.06
HFC-245fa ABS 40 1.05 1.08 1.11 1.07 1.11 1.18 1.07 1.11 1.13 1.09 1.13 1.15 0.96 0.96 0.99 0.96 0.97 1.07 0.97 0.97 0.99 0.99 1.00 1.01
HFC-245fa ABS -10 1.06 1.06 1.08 1.04 1.06 1.12 1.07 1.10 1.07 1.09 1.12 1.12 0.96 0.96 0.97 0.94 0.94 0.99 0.96 0.97 0.94 0.99 1.00 0.99
HFC-245fa HIPS 90 1.05 1.15 1.18 1.05 1.13 1.18 1.08 1.18 1.24 1.08 1.18 1.23 0.96 1.04 1.08 0.94 1.01 1.07 0.97 1.07 1.12 0.98 1.07 1.12
HFC-245fa HIPS 40 1.06 1.11 1.15 1.05 1.09 1.14 1.08 1.14 1.17 1.08 1.15 1.18 0.97 0.99 1.03 0.95 0.96 1.01 0.97 1.01 1.03 0.99 1.03 1.05
HFC-245fa HIPS -10 1.05 1.08 1.08 1.08 1.31 1.40 1.07 1.11 1.12 1.09 1.11 1.12 0.96 0.97 0.97 0.98 1.20 1.28 0.97 0.99 1.00 0.98 1.00 1.00
Cyclopentane ABS 90 1.16 1.22 1.30 1.18 1.22 1.29 1.14 1.22 1.28 1.11 1.18 1.27 1.07 1.13 1.22 1.10 1.16 1.22 1.07 1.17 1.22 1.04 1.11 1.19
Cyclopentane ABS 40 1.16 1.19 1.24 1.18 1.21 1.23 1.14 1.21 1.23 1.12 1.16 1.19 1.06 1.07 1.11 1.10 1.12 1.14 1.07 1.11 1.14 1.04 1.05 1.08
Cyclopentane ABS -10 1.16 1.17 1.18 1.18 1.20 1.21 1.14 1.20 1.19 1.12 1.14 1.14 1.06 1.05 1.06 1.10 1.10 1.11 1.07 1.10 1.09 1.05 1.04 1.04
Cyclopentane HIPS 90 1.17 1.33 1.39 1.18 1.30 1.36 1.16 1.32 1.37 1.11 1.28 1.35 1.09 1.25 1.31 1.12 1.25 1.30 1.10 1.27 1.31 1.02 1.22 1.28
Cyclopentane HIPS 40 1.15 1.24 1.31 1.18 1.24 1.27 1.15 1.26 1.31 1.12 1.23 1.27 1.06 1.13 1.20 1.11 1.16 1.19 1.09 1.19 1.23 1.05 1.14 1.19
Cyclopentane HIPS -10 1.16 1.19 1.21 1.17 1.19 1.20 1.15 1.21 1.23 1.12 1.16 1.18 1.07 1.07 1.11 1.11 1.11 1.11 1.09 1.14 1.15 1.05 1.07 1.09
1.5 1.5
HCFC-141b HCFC-141b
HFC-134a HFC-134a
Normalized Thermal Conductivity
1.3 1.3
1.2 1.2
1.1 1.1
1.0 1.0
0 0.5 1 1.5 2 2.5 0 0.5 1 1.5 2 2.5
1.5 1.5
HCFC-141b HCFC-141b
HFC-134a HFC-134a
Normalized Thermal Conducitivity
1.3 1.3
1.2 1.2
1.1 1.1
1.0 1.0
0 0.5 1 1.5 2 2.5 0 0.5 1 1.5 2 2.5
Figure 3. Aging of foam in full-thickness panels blown with third-generation blowing agents by Supplier A. Tested at 75°F.
two years and 20 years of aging were obtained by scaling the refrigerator will have a plastic sheet, while the other surface
results for 1.5 in.-thick and 0.4 in.-thick core-foam will have an impermeable steel sheet. This effect is
specimens, respectively. The results show that the plastic estimated in the section on modeling.
sheets significantly reduce the rate of aging, with ABS being
more effective than HIPS. The difference between ABS and COMPARISON OF DATA WITH MODEL RESULTS
HIPS may be explained by the relative gas permeances of the
two plastics, as will be shown in the section on modeling. Since aging data on the full-thickness panels are being
Figure 4 also shows that decreasing temperature produces collected on a real-time basis, there is a need for a model
large decreases in the rate of aging, with the changes at 40°F that can predict long-term aging behavior. A one-
being about one-half as large as at 90°F and with the dimensional model for isothermal aging of foam panels with
changes at -10°F being very small. This is in agreement semi-permeable surface sheets has been developed, and is
with the effect of temperature observed on core foam, and being validated against the measured aging data.
also in agreement with the effect of temperature on the Preliminary results from the model are presented here.
permeance of the plastic sheets and for coefficients of
diffusion of gases through the foam, as will be shown in the Description of Model
section on modeling.
The data presented for the test panels should not be The model is similar to those described in the literature for
interpreted directly as quantitative indications of the changes diffusion of gases through foam [e.g, 8]. However, we have
that would be expected in the walls and doors of added the effects of partial condensation of blowing agent
refrigerators. This is because only one surface in a within the foam cells. The transient distribution of a gas
40 40
ABS, 2 years ABS, 2 years
35 HIPS, 2 years HIPS, 2 years
35
Core, 2 years Core, 2 years
Core, 20 years Core, 20 years
30 30
Percent Increase
Percent Increase
25 25
20 20
15 15
10 10
5 5
0 0
HCFC-141b HFC-134a HFC-245fa Cyclopentane HCFC-141b HFC-134a HFC-245fa Cyclopentane
(a) Aged at 90°F; tested at 75°F (b) Aged at 90°F; tested at 45°F
40 40
ABS, 2 years ABS, 2 years
HIPS, 2 years HIPS, 2 years
35 35
Core, 2 years Core, 2 years
Core, 20 years Core, 20 years
30 30
Percent Increase
25 Percent Increase 25
20 20
15 15
10 10
5 5
0 0
HCFC-141b HFC-134a HFC-245fa Cyclopentane HCFC-141b HFC-134a HFC-245fa Cyclopentane
(c) Aged at 40°F; tested at 75°F (d) Aged at 40°F; tested at 45°F
35 35
ABS, 2 years ABS, 2 years
HIPS, 2 years HIPS, 2 years
30 30
Core, 2 years Core, 2 years
Core, 20 years Core, 20 years
25 25
Percent Increase
Percent Increase
20 20
15 15
10 10
5 5
0 0
HCFC-141b HFC-134a HFC-245fa Cyclopentane HCFC-141b HFC-134a HFC-245fa Cyclopentane
-5 -5
(e) Aged at -10°F; tested at 75°F (f) Aged at -10°F; tested at 45°F
and yi are the thermal conductivity and mole fraction of the
Mc M2c ith gas, and Aij is given by the Lindsay-Bromley equation,
' D (1)
Mt Mx 2 2
1/2
Sij Sij
0.75 1 % 1 %
1 µi Mj T T (4)
where c is the concentration of gas in moles per unit volume, Aij ' 1 %
4 µj Mi Sj Si
D is the effective diffusion coefficient which is taken to be a 1 % 1 %
constant, t is time, and x is distance. The gas concentration T T
(c) and pressure (P) are related through the ideal gas law, c
= P/RT, where R is the gas constant, and T is the absolute
temperature. The foam is produced at relatively high where µ i, Mi, and S i are the dynamic viscosity, molecular
temperatures, but the panels are being aged at lower weight, and Sutherland constant for the ith gas, and T is the
temperatures, where a fraction of the blowing agent can be absolute temperature. Also, Si = 1.5 T bi, where T bi is the
in a condensed state. In this case, it is assumed that the normal boiling point of the ith gas, and Sij = (SiSj)½ for non-
liquid is immobile and the only mechanism for transport of polar gases. Gas properties needed for specimens blown
the blowing agent is by vapor diffusion. The vapor pressure with HCFC-141b are given in Table 3.
curve provides an upper limit on the gas pressure, and a The total apparent thermal conductivity, k, at a plane
mass balance is added to track the distribution of liquid and within the specimen is then calculated from the equation
vapor phases of the blowing agent. given by Glicksman [15] as
The initial conditions for Equation 1 are that the
k ' k sol % k rad % * k gas ' k0 % *k gas (5)
concentrations of oxygen and nitrogen are zero, while the
concentrations of carbon dioxide and blowing agent are
uniform, with values that are provided by the foam supplier.
Boundary conditions for Equation 1 are given by application where ksol represents conduction through the solid polymer
of Fick’s first law of diffusion: cell walls and struts, k rad represents radiation through the
foam, * is the void fraction (taken to be about 0.97), and kgas
Mc
& D ' K (c0 & c) (2) is the thermal conductivity of the gas mixture. Glicksman
Mx gives formulae for estimating the values of ksol and k rad;
however, for the purposes of this study, their sum is
estimated from the measured thermal data. The average
where K is the permeance of a surface sheet (K = 4 for bare thermal conductivity of the specimen is then calculated from
cut foam, 0 for solid metal surface, and intermediate values an integral over the thickness (L) of the specimen,
for plastic sheets on the surface), c0 is the concentration of &1
L
gas in the space surrounding the panel, and c and the
L m k(x)
1 1
derivative are evaluated at the interface between the foam k avg ' dx (6)
and the surface sheet. The model has been formulated to 0
j y j A ij
N
i'1 (3) a gravimetric method that was developed by Booth [17].
j'1
Data that have been obtained to date are given in Table 5.
The large differences among the gases should be noted with
both the permeances and diffusion coefficients being ordered
where kgas is the thermal conductivity of the gas mixture, kgi as CO2 > O2 > N2. Values of these two parameters at
temperatures other than those at which values were for example,
measured were estimated from the Arrhenius equation, as,
Table 3. Gas Properties for Calculation of Thermal Conductivity of Gas Mixture at 75°F
Thermal
Conductivity, Viscosity, Molecular Weight Normal Boiling
Gas Btu•in./h•ft²•°F centipoise* Point, K
Table 4. Permeances of Gases through 0.040-in.-thick ABS and HIPS Plastic Sheets
HIPS ABS
Gas
40°F 90°F 40°F 90°F
A
above, the model used only two other adjustable parameters.
&
D ' D0 e RT (7) These are the coefficient of diffusion for HCFC-141b, and
the sum of the radiative and solid contributions to the
thermal conductivity (k0 in Eq. 5). For aging of the thinner
slices at 90°F, the model predicted that diffusion of all gases
Values of D0 and A were evaluated from the data at two except HCFC-141b had been completed by about 300 days.
temperatures. After this, the slight increase in thermal conductivity is due
to loss of the blowing agent. By a trial and error process, a
Comparison of Model with Data diffusion coefficient of about 2.5 × 10-10 cm²/s was found to
provide a good match for the data. For other temperatures,
Figure 5 shows a comparison of model predictions with the ratio of diffusion coefficients for the blowing agent and
measured thermal data for the thinner slices of core foam nitrogen was assumed to be the same as at 90°F. This
blown with HCFC-141b. In addition to the parameters given assumption is not critical, since the importance of diffusion
0.20
time period are needed for a more thorough assessment of
ABS; -10°F
Refrigerator Panels - One-Year Results with Third-
10
90°F generation Blowing Agents,” The Earth Technologies
Forum, pp. 303-313.
5
40°F
5. C 518, “Standard Test Method for Steady-State Heat Flux
0 -10°F
Measurements and Thermal Transmission Properties by
Means of the Heat Flow Meter Apparatus,” in 1999 Annual
-5 Book of ASTM Standards. West Conshohocken, PA:
0 0.5 1 1.5 2 2.5 American Society for Testing and Materials, Vol. 04.06, pp.
Time, years
(a)
171-183.
between the model and the full-thickness data. Comparisons 6. Haworth, G. J. 1996. “Next Generation Insulation Foam
on more panels, and over a longer time period are needed for Blowing Agents for Refrigerators/Freezers,” Proceedings,
47th International Appliance Technical Conference, pp. C. Hilyard and A. Cunningham, eds. London: Chapman &
271-282. Hall, pp. 153-186.
7. C 1303, “Standard Test Method for Estimating the Long- 9. Reid, R. C. and T. K. Sherwood. 1966. The Properties
Term Change in the Thermal Resistance of Unfaced Rigid of Gases and Liquids, 2nd Ed. New York: McGraw-Hill,
Closed Cell Plastic Foam by Slicing and Scaling Under pp. 483-484.
Controlled Laboratory Conditions,” in 1999 Annual Book of
ASTM Standards. West Conshohocken, PA: American 10. ASHRAE Handbook-Fundamentals. 1997. Atlanta:
Society for Testing and Materials, Vol. 04.06, pp. 719-726. American Society of Heating, Refrigerating, and Air-
Conditioning Engineers, pp. 19.75-19.79.
8. Hoogendoorn, C. J. 1994. “Thermal Ageing,” in Low
Density Cellular Plastics: Physical Basis of Behaviour, N.
11. Eckert, E. R. G. and R. M. Drake, Jr. 1959. Heat and Corning and, since 1987, at the Oak Ridge National
Mass Transfer. New York: McGraw-Hill, p. 506. Laboratory. He holds a B.S. in Mechanical Engineering
from Duke University, an M.S. in
12. Shankland, I. R., D. J. Williams, M. C. Bogdan, and P. Mechanical Engineering from Purdue University, and a
B. Logsdon. 1998. “Next Generation Blowing Agents for Ph.D. in Condensed Matter Physics from The Ohio State
Thermal Insulating Foams,” in 60 Years of Polyurethanes, University. He is a registered professional engineer and is
J. E. Kresta, E. W. Eldred, eds. Lancaster, PA: Technomic active in ASTM Committee C 16 on Thermal Insulation.
Publishing Co., Inc., .p.86.
BIOGRAPHIES
Kenneth E. Wilkes
Fred J. Weaver
J. Richard Booth