You are on page 1of 1

ERS 2500

Ethernet Routing Switch 2500 Series


Steps 7
Powering Up
9
d. The Nortel switch banner appears when you
connect to the switch through the Console port. Enter

Quick Install Guide


Ctrl+Y and type the following CLI commands:
• enable

7
7. Connect the AC power cord to the back of the
switch, and then plug the other end of the cord into an • install
AC power outlet. The CLI Quickstart welcome screen helps you to
Steps 4 6
enter the information requested at each prompt.
All documents referenced in this Quick
Installation Guide can be downloaded at
Mounting Options Reset
Status
PWR
25
Speed
Link/Act

PoE
26

4
1

6
3

8
5

10
7

9
11

13

15

17

CLI Quickstart welcome screem


12 19

14 21

23
16

18 25

20 27

22 29

www.nortel.com.

4
24 31

33
26
35
28

30 37

31 39

33 41

35 43

45
38
47
40

42

Welcome to the 2550T setup utility. You


Warning: You must use a power cord set approved for the
44

46

48

Steps 1 3 2500 Series switch and the power receptacle type in your country.
will be requested for information to initially

Before you start


configure for the switch. When finished the
information will be applied and stored in
4. If you are mounting the switch on the switch NVRAM. Once the basic parameters

8
8. Check the front-panel LEDs as the device

1
are configured, additional configuration can
a table or shelf, attach the rubber proceed using other management interfaces.
powers on to be sure the PWR LED is lit. If not,
feet to the device as indicated. Press ^C to abort at any time.
check that the power cable is plugged in correctly.
The in-band IP Address prompt line appears
1. Confirm that you have the tools and package Please provide the in-band IP Address[0.0.0.0]:
contents as follows: a. Set the device on a flat surface near an Front Panel 2526T-PWR with 12 PoE ports 10.127.232.30

Tools Required: AC power source, making sure there are at Speed


Link/Act
1 3 5 7 9 11 13 15 17 19 21 23
2526T-PWR The in-band sub-net mask prompt line appears
Please provide the in-band sub-net mask[0.0.0.0]:
least 2 inches (5.1 cm) of space on all sides
Up/28 25 26

Phillips #2 screwdriver
Down/27

Base

Status 255.255.255.0
for proper air flow and at least
PWR

Package Contents: PoE

The Default Gateway prompt line appears


5 inches (12.7 cm) at the back for power cord
2 4 6 8 10 12 14 16 18 20 22 24

Please provide the Default Gateway[0.0.0.0]:


b clearance. Front Panel 2550T-PWR with 24 PoE ports 10.127.232.1

5
2550T-PWR
The Read-Only Community String prompt line appears
Speed
Link/Act

c
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47

a Up/52

Down/51
49 50

Please provide the Read-Only Community


Base

Status

PWR String[**********]:******
d 25
Speed
Link/Act
25
Speed
Link/Act

26
1
PoE
2 4 6 8 10 12
PoE
14 16 18 20 22 24 26 28 30 31 33 35 38 40 42 44 46 48

The confirm Read-Only Community String prompt line appears


26 Status
1 3

5. If you are mounting the switch on a


PWR
3
Status 5 Reset 5
PWR 7 7
9
Reset 9
11
11
13
15 13

The 2500 Series switches begin switching data as soon as you


PoE
17
2 15
PoE 19
2 21 4 17
4 23
6 19
6 25
8 8 21
27
10 29 10 23
12 31 12
25

Please confirm the Read-Only Community


14 33
16 35 14 27
18 37 16 29

rack, attach the rack mount brackets


20 39
22 18 31
41
24 43 20 33
26 45 22 35
28 47
24 37
30
31 26 39

attach network devices and connect the switch to the power


33
35 28 41

38 30 43

String[**********]:******
40 31 45
42
33 47
44
46 35
48
38
40
42

a. Ethernet Routing Switch 2500 Series switch to each side of the device using the
44
46
48

supply. The Read-Write Community String prompt line appears


b. Rack and wall mounting hardware screws provided. Choose the Please provide the Read-Write Community
• Rack and wall mounting brackets (2) appropiate rack-mount for attaching

9
String[**********]:*******
• Screws for attaching brackets to the the switch to your data or phone rack. Setting IP parameters using the console port The confirm Read-Write Community String prompt line appears
switch (8) a. Slide the switch into 25
Speed
Link/Act
and CLI Quickstart Please confirm the Read-Write Community
• Screws for attaching the switch to the
26

Status
1
3

String[**********]:*******
PWR

the rack. Insert and


Reset 5
7
9
11

9. To set IP parameters using the console port and CLI Quickstart,


PoE 13
2 15

4 17

6 19

8 21
23

equipment rack (2x4)


10
12
25
14 27

tighten the rack-mount


16 29
18 31

The Quick Start VLAN prompt line appears


20 33
22 35
24 37
26 39

perform the following tasks:


28 41
30 43
31 45
33 47

Choose the appropriate rack-mount


35

38

screws.
40

Please provide the Quick Start VLAN <1-4094> [1]:


42
44
46
48

screws for attaching the switch to your

6
The Basic Switch parameters configuration confirmation appears
data or phone rack. a. Connect a terminal to the console port of the switch. Basic switch parameters have now been configured and
c. Adhesive foot pads (4) Any terminal or PC with an appropriate terminal emulator can be saved.
d. AC power cord 6. If you are mounting the switch on a wall, position the brackets so that used as the management station. The Terminal emulation

10
the brackets are 90 degrees to the switch side and two-holeedge faces

2
settings table below lists the parameters that must be used with
the bottom of the switch. any terminal emulation software used to connect to the switch.
2. (Optional) Prepare the rack:
a. Provide 2.8 inches of vertical space for each Stacking ERS 2500 switches
switch in an EIA or IEC-standard 19-inch a. Attach the brackets to each side of
Speed
Link/Act

25
26

Status
1
3
PWR

Reset 5
7
9

the device.
11

(48.2-centimeter) equipment rack.


PoE 13
2 15

10. Rear ports support Stacking Mode operation


4 17

6 19

8 21

10 23
12
25
14 27
29

b. Bolt the rack to the floor and brace it, if necessary.


16
18 31 Up Base
Cascade 52
20 33
Port Select
Down

beginning in software release 4.1 and higher.


Unit
Cascade 51
35
Port
22
->
24
->
Stacking ne
37 Standalo
MODE:
26 39

28 41
30 43
31 45

c. Ground the rack to the same grounding electrode


33 47
35

Stacking capability is available through one of two


38
40
42
44
46
48
MAX

used by the power service in the area. The ground


2.9 A Hz
50-60 AC
100-240V
ACLINE

ways:
path must be permanent and must not exceed - Stacking License for ERS 2500 units with order
1 Ohm of resistance from the rack to the grounding codes AL2500xxx-E6
electrode. Nortel recommends using a filter or surge - Stack Pre-enabled ERS 2500 units with ordercodes
b. Secure the brackets
suppressor. To connect the terminal to the switch console port, you require a AL2515xxx-E6
to the wall using

3
appropriate screws and console cable and connector to match the male DTE connector For more information about rear port functionality,
3. When you install the switch into a network, wall anchors (not refer to the Ethernet Routing Switch 2500 Series
(DB-9) on the switch.
ensure you use the following required cables: provided).
• Category 3, 4, or 5 UTP cable with an RJ-45 connector (for b. Set the terminal protocol on the terminal or You are now ready to use the 2500 Series switch
Note: One 2500 Series switch weighs as much as
100 Mb/s operation) terminal emulation program to VT100 and in your network installation.
11.6 lbs (5.26 kg). Ensure you choose fasteners
• Category 5 UTP cable with an RJ-45 connector (for 100 VT100/ANSI.
appropriate for the weight of the unit. One person can lift
Mb/s operation) c. Connect to the switch using the terminal or
• Category 5 Four-Pair UTP cable with an RJ-45 connector and install the 2500 Series switch.
terminal emulation application.
(for 1000 BASE-T ports with 1000 Mb/s operation)
• Console Port Straight-through serial cable with DB-9 female
connector at one end
NN47215-300 (323170-B) Ver. 02.02

You might also like