Professional Documents
Culture Documents
With over 25 years experience in the medical device field, our legacy products include a wide range of
different stopcocks, manifolds and needleless devices in order to improve health care worker safety.
Elcam Medical has Standard, High Pressure, High Flow (Large bore) and custom stopcocks. These are
strengthened by our new products - Swabbable (Closed) Stopcock, Marvelous (Minimal Residual Volume)
Stopcock, Antimicrobial Stopcocks , Disposable Pressure Transducer (DPT) and Flush Device. Elcam has
entered the interventional space with the Y-Click device for PTCA procedures and the H-Flow Y-Click
hemostatic valve for angiography. Finally, the new and innovative Flexi-Q product line for drug
delivery that is soon to be commercially available. Flexi-Q will be available in both a prefilled
version and for drugs in vials.
H-Flow Valve
Haskal™
Torque Device
Elcam Medical Elcam Medical INC. MedNet GmbH Elcam China Office
BarAm 13860 2 University Plaza, Suite 620 Borkstrasse 10 Room 3309, Jinhai Mansion
Israel Hackensack, NJ 07601 Muenster Germany 48163 No. 89 of Anshun Road, 0483
Tel: 972-4-698-8120/1/2 Tel: +1 201 4571120 Tel: +49 (0) 251 32266 0 Sanghai, PRC. Zip: 200051
Fax: 972-4-698-0777 Fax: +1 201 4571125 Fax: +49 (0) 251 32266 22 Tel: +86 2162829965
sales@elcam.co.il info@elcam-medical.com info@medneteurope.com Fax: +86 21 62829967 ISO 13485
www.elcam-medical.com www.elcam-medical.com www.medneteurope.com johnliu02@126.com ISO 9001
DPT
Haskal™ Guidewire MEDIUM PRESSURE
Torque Device STOPCOCK
Side mounted, Easy-to-Use Torque Device Withstands 500 psi
Elcam’s Y-Click connector provides an easy-to- Angiographic catheters require hemostatic flow Elcam Medical’s High Pressure Stopcocks are suitable Elcam Medical DPT is indicated for pressure sensing
use hemostatic device for both diagnostic and control devices for safe handling of guidewires and for Cath-Lab applications and were designed to during clinically invasive procedures without interfering
interventional procedures. This ergonomically flushing with heparin and saline in order to avoid withstand 1200 PSI pressure. Our High Pressure with the patient’s blood flow and/or blood pressure.
designed device significantly reduces the blood in-catheter clotting and potential emboli. Elcam’s Stopcocks are available in 1 way and 3 way By hydraulic connection the pressure is transferred to
loss during interventional procedures. Among H-Flow Valve is a luer activated self-sealing device configurations with rotating High Pressure adapters or the sensing unit, which converts it to an electrical signal.
the Y-click’s most unique advantages are its self- which allows convenient placement and positioning of standard swivel luer lock nut.
closing mechanism and semi-open position, as well common guidewires and micro catheters through an
as its one-handed operation. angiographic catheter with no leakage.It withstands
repeated high pressure injections up to 1200 psi.