Date
Vision
Objectives
Targets
3: Implementation Strategy
Narrative:
IDP-R2: Tenant Fit-Out Design & Construction Guide Project Reference Number ESB-DES-0000
Consultant to fill only shaded areas
IDPT Responsible Individuals Signature Role Date Revision
Documents / Approved
Submission Requirements Submitted Comments
Attachments Yes No
Narrative describing how the
mechanical design system meets the
26 Credit Requirements, including
description of mechanical ventilation
system
Documentation of an observational
study of local air quality including
27
photographs of surrounding sources of
pollutant emissions
Mechanical system drawings marked-
up to clearly show distances between
air intake points and exhaust air or
28
other discharge points and the
distances from the air exhaust points
to any defined public realm areas
Spreadsheet calculations of fresh air
29 ventilation rates based on the
ventilation rate procedure for all zones
Calculation Results
Document / Approved
Submission Requirements Submitted Comments
Attachment Yes No
Written commitment from the
building owner/developer that there
will be no smoking policy operated
within the building or common areas
30 for residential buildings or additionally
for school grounds by inclusion in
Contracts of Sale and Lease/Rent
Agreements that smoking will be
banned by future owners and tenants
Extracts from specifications and/or
drawings indicating the locations of
posted signage stating that the entire
31 building is a no smoking environment
and detailing the negative health
impacts of smoking installed in all
dedicated external smoking areas
Drawings indicating the location of
dedicated outside smoking areas and
facilities for collecting ash and
32
cigarette ends which clearly indicate
their distance from entrances,
operable windows and air intakes
For residential units, provide
specifications for weather-stripping of
33
doors and drawings that highlight
impermeable deck to deck partitioning
Calculation Results
Document / Approved
Submission Requirements Submitted Comments
Attachment Yes No
Narrative and drawings of the air
conditioning systems regardless of
whether water-based cooling towers are
34 present or not. The Narrative must explain
the approach to Legionella Management,
or confirm no water-based systems are
present
35 Narrative and drawings of the
project’s other water-based systems;
Relevant water based systems include but
are not limited to:
• Water systems incorporating a cooling
tower;
• Water systems incorporating an
evaporative condenser;
• Hot and cold water systems;
• Other plant and systems containing
water which is likely to exceed 20ºC and
which may release a spray or aerosol
during operation OR when being
maintained; Humidifiers; Air washers;
• Spa baths and Pools;
• Car / bus washes;
• Wet scrubbers; Fountains and
Calculation Results
=
Plan 2030 (Refer to planning approval)
Project Site
Urban Context
Connectivity
1.b: Maps
Shading Provisions
Playgrounds 90%
Other
Shading Systems
List of all Shading Elements for the Applicable Spaces (minimum SRI of 29)
SRI Value Achieved?
Shading Element Solar Reflectance Index (SRI)
Yes No
Narrative
Environmental Impact
assessment report including
17
protection and mitigation
strategies
Supporting calculations
Other:
Brief:
NS-R3: Natural Systems Design & Management Strategy Project Reference Number ESB-DES-0000
Consultant to fill only shaded areas
IDPT Responsible Individuals Signature Role Date Revision
=
ecological Consultant(s) Details (if different to the consultant details provided in NS-R1)
PW-R1: Min. Interior Water Use Reduction Project Reference Number ESV-DES-0000
Calculation Results
Demonstrate that easily accessible and clearly labeled water meters are provided and capable of monitoring the water
consumption of, at a minimum, the following exterior water uses (where present):
• Heat rejection;
• External hose bibs;
• Irrigation systems;
• Swimming pools; and
• Water features
All meters must have data logging capability and be connected to a central monitoring system so that information on
the exterior water consumption can be recorded
Calculation Results
Document / Approved
Submission Requirements Submitted Comments
Attachment Yes No
Energy Model Template summarizing
the dynamic energy simulation,
confirming that the minimum
requirements of this credit will be
achieved; this should cover the
followings but not limited to:
Lighting; Heating; Cooling; Heat
rejection; Pumps; Fans; Service water
heating; and Receptacle and process
44
loads
Demonstrate a minimum 12%
performance improvement compared
to the baseline building performance
demonstrated by the energy
simulation model as per the
methodology outlined within Appendix
G of Standard 90.1-2007.
Calculation Results
Document / Approved
Submission Requirements Submitted Comments
Attachment Yes No
45 o Brief narrative describing how the
requirements of the credit will be
achieved;
Demonstrate that easily accessible
and clearly labeled energy sub-
meters are provided which enable a
minimum of 90% of the estimated
annual energy consumption for
major end use energy consuming
plants, equipments and appliances
• Cooling
• Dehumidification
• Service water heating
• MCC fans
• MCC pumps
• Lighting
• Receptacles and process loads
• Other major energy consuming
plants (swimming pools, kitchens,
server room, lifts and escalators
for all building areas; landlord,
offices, retails, residential and
non residential areas
All onsite energy generating systems
must be separately metered
Separate meters must be provided
for all plant exceeding the sizes in
the table below:
Plant Description
Cooling installations comprising one or more units feeding a common distribution circuit
Motor control centers providing power to HVAC equipment
Final electrical distribution boards (power/lighting)
o Narrative Building Type; school,
multi-residential, office, retails,
mix use
Calculation Results
ADM | RE-R3: Ozone Impacts of Refrigerants & Fire Suppression Systems Page 1 of 2
1 Pearl Building Rating System - Design Rating
Calculation Results
ADM | RE-R3: Ozone Impacts of Refrigerants & Fire Suppression Systems Page 2 of 2
1 Pearl Building Rating System - Design Rating
Schedule of items to be
53 recycled/salvaged (complete
Design table below)
Measurement unit