AMPCO ARCHITECTURAL
FLUSH WOOD DOOR SPECIFICATIONS
SUBMITTAL SHEETS
FOR 7-PLY WOOD DOORS
Stiles: Bonded to the core except SHC. Mill option hardwood or match to face veneer.
End Rails: Bonded to the core except SHC. Mill option hardwood or structural composite
lumber (SCL).
Glass Openings (specify size, location, moulding type and glass thickness): ____________________________
_____________________________________________________________________________________________
Louvers (specify size, location, louver type and if metal, specify moulding type and louver thickness):
________________________________________________________________________________________________________
Prefit Clearances: Standard (For hinged doors: 1/8“ top, 1/2” bottom, singles 1/4” width, pairs 3/16”
width)
Edge Machining: Standard (For hinged doors: bevel lock edge 1/8“ in 2”, square hinge edge)
Ampco Products, Inc., 4840 NW 128 St. Rd., Opa Locka, FL 33054 TeL: 305.821.5700
AMPCO ARCHITECTURAL SHC Wood
FLUSH WOOD DOOR SPECIFICATIONS Hollow Core Wood Door
®
AWI: SHC
Frame Components:
Stiles: (before trim or prefit) 1 3/8”
one piece mill option kiln-dried
hardwood or to match face veneer
species. Not bonded to core.
Matching stile edges can be
provided.
Rails: (before trim or prefit) 1 ¼”
mill option kiln-dried hardwood or
structural composite lumber (SCL).
honeycomb core
Ampco Products, Inc., 4840 NW 128 St. Rd., Opa Locka, FL 33054 TeL: 305.821.5700
AMPCO ARCHITECTURAL PC/PC20 Wood
FLUSH WOOD DOOR SPECIFICATIONS Particle Board Core
®
AWI: PC – 7 OR FD 1/3
Quality Standards: Conforms to NWWDA Faces: 1/8” - 3 ply cross banded hardwood
Industry Standard I.S.-1, and Architectural face veneer, 1/30” face veneer prior to
Woodwork Institute section 1300-G-3 and sanding.
1300-G-4 for type PC7 or FD 1/3, and
ASTM E-152, Fire Test of Door Assemblies Adhesive: Type I or Type II bond, by
as performed by Warnock Hersey specification, between faces and core/frame
International. components. Formulated using no
formaldehyde.
Maximum Size:
Single Door: (unrated) 4/0 X 10/0 Assembly: 7 ply when using 3 ply
Single Door: (20 minute) 4/0 X 9/0, 3/0 X hardwood face feneer. Core and frame
10/0 components are bonded and uniformly
Pairs: (unrated) 4/0 X 10/0, 8/0 x 10/0 sanded to a thickness of 1 ½“ (± .015). For
Pairs: (20 minute) 4/0 X 9/0, 8/0 X 9/0 FD 1/3, core and frame components are
Double egress: 8/0 X 9/0 with concealed assembled to meet or exceed 20 minute
vertical rod exit devices. specifications.
Ampco Products, Inc., 4840 NW 128 St. Rd., Opa Locka, FL 33054 TeL: 305.821.5700
AMPCO ARCHITECTURAL SLC/SLC20 Wood
FLUSH WOOD DOOR SPECIFICATIONS Staved Lumber Core
®
AWI: SLC – 7 or FD 1/3
Ampco Products, Inc., 4840 NW 128 St. Rd., Opa Locka, FL 33054 TeL: 305.821.5700
AMPCO ARCHITECTURAL MC45 Wood
FLUSH WOOD DOOR SPECIFICATIONS C Label 45 Minute Fire Door
®
AWI: FD 3/4
Quality Standards: Conforms to NWWDA Assembly: 7 ply when using 3 ply hardwood
Industry Standard I.S.-1, and Architectural face veneer. Core and frame components are
Woodwork Institute section 1300-G-4 for bonded per Warnock Hersey manufacturing
Type FD ¾, ASTM E-152 fire test of door authorities and sanded to uniform thickness
assemblies as performed by Warnock of 1 ½ “ (±.015).
Hersey International.
Warranty: Lifetime from date of manufacture.
Maximum Size: Single Door: 4/0 X 10/0, For original installation only.
3/0 X 10/0 with transom.
Pairs: 8/0 X 9/0 Label Authority: Labeled and classified by
Double egress: 8/0 X 8/0 Warnock Hersey International as a 45 minute
Metal edge and astragal required on pairs. fire barrier in sizes as described above with
vision panels having aggregate areas of 1296
Thickness: 1 3/4“ (±1/16”) square inches either singularly or in
multiples.
Frame Components:
Stiles: (before trim or prefit) 1“ mill option Application Exception: Exterior application of
hardwood untreated or clear fir with a this product requires specification of Type I
minimum density of 28.75 pounds per cubic optional adhesives for construction of all door
feet (pcf) or other species having equal components including faces. This application
density. Bonded to the core. also requires additional architectural
Rails: (before trim or prefit) accessories and special finishes (see
Top: 1“ untreated hardwood or clear Architectural Accessories Details, Section V),
fir with a minimum of 28.75 pcf or and reduces the warranty period from lifetime
other species having an equal to two years.
density. Bonded to the core.
Bottom: 2“ hardwood with minimum
of 28.75 pcf or other species having
an equal density. Bonded to the core. *Fire labeled doors may not be refit in the
field if already factory prefit or machine sized.
Interior Blocking: In some applications the
addition of optional GP Firestop®
GP homogeneous mineral
composition may be required due to fire
rating and hardware specifications.
1” hardwood top rail
1” hardwood stiles
Hinges: 4½“ X 4½ ” X 0.134” minimum or
1/30” back veneer
per NFPA #80
1/16” cross banding
Core: Georgia Pacific homogenous mineral
core with minimum density of 26 pounds per
cubic foot. 1/30” face veneer
Ampco Products, Inc., 4840 NW 128 St. Rd., Opa Locka, FL 33054 TeL: 305.821.5700
AMPCO ARCHITECTURAL MC60 Wood
FLUSH WOOD DOOR SPECIFICATIONS B Label 60 Minute Fire Door
®
AWI: FD 1
Hinges: 4 ½“ x 4 ½” x 0.134”
minimum or per NFPA #80
1 1/2” hardwood
Core: 1/16“ thick lead sheet, full
width of core, sandwiched and boned 1/8” – 3 ply cross
to AB grade exterior plywood and banded hardwood face
veneer
securely fastened with lead bolts.