AMPCO ARCHITECTURAL
FLUSH WOOD DOOR SPECIFICATIONS

SUBMITTAL SHEETS
FOR 7-PLY WOOD DOORS

Ampco Products, Inc.


4840 NW 128 Street Road
Opa Locka, Florida 33054
Voice: 305.821.5700
Fax: 305.688.5160
www.ampco.com
opalocka@ampco.com
AMPCO ARCHITECTURAL SUBMITTAL SHEET
FLUSH WOOD DOOR SPECIFICATIONS FOR WOOD DOORS
®

Job Name: ________________________ Contract/Job Number: _____________


Submitted by: _________________________Date: _______ Sheet_____of_____
Revisions: ____________________Date: __________ By: _____________________
Revisions: ____________________Date: __________ By: _____________________

Door Types (enter quantity required):


SHC Wood 7 ply hollow core (A.W.I. SHC)
PC Wood PC20 Wood 7 ply particle board core (A.W.I. PC-7)
SLC Wood SLC20 Wood 7 ply staved lumber core (A.W.I. SLC-7)
MC45 Wood 9 ply 45 minute mineral core fire door, C label (A.W.I. FD ¾)
MC60 Wood 9 ply 60 minute mineral core fire door, B label (A.W.I. FD 1)
MC90 Wood 9 ply 90 minute mineral core fire door, B label (A.W.I. FD 1
1/2)
LL Wood 7 ply lead bonded to plywood core (A.W.I. LL)

Stiles: Bonded to the core except SHC. Mill option hardwood or match to face veneer.

End Rails: Bonded to the core except SHC. Mill option hardwood or structural composite
lumber (SCL).

Face Veneers (specify grade, cut and species): ___________________________________________________


_____________________________________________________________________________________________

Glass Openings (specify size, location, moulding type and glass thickness): ____________________________
_____________________________________________________________________________________________
Louvers (specify size, location, louver type and if metal, specify moulding type and louver thickness):
________________________________________________________________________________________________________

Prefit Clearances: Standard (For hinged doors: 1/8“ top, 1/2” bottom, singles 1/4” width, pairs 3/16”
width)

Other (please specify): _____________________________________________

Edge Machining: Standard (For hinged doors: bevel lock edge 1/8“ in 2”, square hinge edge)

Other (please specify): _____________________________________________

Packaging: Standard Individually polybagged Other:

Ampco Products, Inc., 4840 NW 128 St. Rd., Opa Locka, FL 33054 TeL: 305.821.5700
AMPCO ARCHITECTURAL SHC Wood
FLUSH WOOD DOOR SPECIFICATIONS Hollow Core Wood Door
®
AWI: SHC

Quality Standards: Conforms to Adhesive: Type II bond between


NWWDA Industry Standard I.S.-1, faces and core components.
and Architectural Woodwork Formulated using no formaldehyde.
Institute section 1300-G-6 for type
SHC.
Assembly: Frame components are
stapled together and core is
Maximum Size: dropped into position.
Single Door: 4/0 x 8/0
Pairs: 4/0 x 8/0 or 8/0 x 8/0
Warranty: Two years from date of
manufacture. For original
Thickness: 1 3/8” (± 1/16”) or 1 installation only.
3/4” (±1/16”)

Frame Components:
Stiles: (before trim or prefit) 1 3/8”
one piece mill option kiln-dried
hardwood or to match face veneer
species. Not bonded to core.
Matching stile edges can be
provided.
Rails: (before trim or prefit) 1 ¼”
mill option kiln-dried hardwood or
structural composite lumber (SCL).
honeycomb core

1 3/8” hardwood top


Interior Blocking: 2 5/8“ mill
1 3/8” hardwood
option wood lock blocks standard.
1/30” back veneer

1/16” cross banding

Core: Expanded corrugated


honeycomb core with maximum 5“
1/30” face veneer
cells.

Faces: 1/8“- 3 ply crossbanded


1 1/4” hardwood
hardwood face veneer meeting bottom rail
AMPCO
AWI or NWWDA grading rules as
SHC WOOD
specified. Type II bond between

Ampco Products, Inc., 4840 NW 128 St. Rd., Opa Locka, FL 33054 TeL: 305.821.5700
AMPCO ARCHITECTURAL PC/PC20 Wood
FLUSH WOOD DOOR SPECIFICATIONS Particle Board Core
®
AWI: PC – 7 OR FD 1/3

Quality Standards: Conforms to NWWDA Faces: 1/8” - 3 ply cross banded hardwood
Industry Standard I.S.-1, and Architectural face veneer, 1/30” face veneer prior to
Woodwork Institute section 1300-G-3 and sanding.
1300-G-4 for type PC7 or FD 1/3, and
ASTM E-152, Fire Test of Door Assemblies Adhesive: Type I or Type II bond, by
as performed by Warnock Hersey specification, between faces and core/frame
International. components. Formulated using no
formaldehyde.
Maximum Size:
Single Door: (unrated) 4/0 X 10/0 Assembly: 7 ply when using 3 ply
Single Door: (20 minute) 4/0 X 9/0, 3/0 X hardwood face feneer. Core and frame
10/0 components are bonded and uniformly
Pairs: (unrated) 4/0 X 10/0, 8/0 x 10/0 sanded to a thickness of 1 ½“ (± .015). For
Pairs: (20 minute) 4/0 X 9/0, 8/0 X 9/0 FD 1/3, core and frame components are
Double egress: 8/0 X 9/0 with concealed assembled to meet or exceed 20 minute
vertical rod exit devices. specifications.

Thickness: 1 3/4” (± 1/16”) or 1 3/8” (± Warranty: Lifetime from date of


1/16”) manufacture. For original installation only.

Frame Components: Label Authority: For FD 1/3, labeled and


Stiles: (before trim or prefit) 1 3/8” mill classified by Warnock Hersey International
option kiln-dried hardwood or stiles to as a 20 minute fire/smoke barrier.
match face veneer species. Bonded to the Restrictions on machining and architectural
core. accessories or application are per that
Rails: (before trim or prefit) 1 1/4“ mill authority.
option kiln-dried hardwood or structural
composite lumber (SCL). Bonded to the *Fire labeled doors may not be refit in the
core. fi ld if l d f fi hi

Interior Blocking: In some applications,


the addition of optional solid wood particle board core

interior blocking may be required due to 1 1/4” hardwood top


fire rating and hardware specifications. 1 3/8” hardwood

Hinges: (20 minute) 4 ½“ x 4 ½” x 0.134”


minimum or per NFPA #80 1/8” – 3 ply cross
banded hardwood with
1/30” face veneer

Vision Panels: (20 minute) Maximum lite


size for 20 minute fire rating, no more 1/30” face

than 1296 sq in.

Core: Wood particleboard door core to


meet or exceed American National
Standard ANSI A208.1, for 1-LD-2 Door 1 1/4” hardwood
Core. Mat-formed particleboard with bottom rail
AMPCO
density approx. 28-32 pounds per cubic PC/PC20 WOOD
feet (pcf) to meet or exceed Commercial

Ampco Products, Inc., 4840 NW 128 St. Rd., Opa Locka, FL 33054 TeL: 305.821.5700
AMPCO ARCHITECTURAL SLC/SLC20 Wood
FLUSH WOOD DOOR SPECIFICATIONS Staved Lumber Core
®
AWI: SLC – 7 or FD 1/3

Quality Standards: Conforms to NWWDA core/frame components. Formulated using


Industry Standard I.S.-1, and Architectural no formaldehyde.
Woodwork Institute section 1300-G-3 and
1300-G-4 for types SLC-7 or FD 1/3, and Assembly: 7 ply when using 3 ply
ASTM E-152, Fire Test of Door Assemblies hardwood face veneer. Core and frame
as performed by Warnock Hersey components are bonded and uniformly
International. sanded to a thickness of 1 ½“ (±.015). For
FD 1/3, core and frame components are
Maximum Size: assembled to meet or exceed 20 minute
Single Door: (unrated) 4/0 x 10/0 specifications.
Single Door: (20 minute) 4/0 x 9/0, 3/0 X
10/0 Warranty: Lifetime from date of
Pairs: (unrated) 4/0 X 10/0, 8/0 X 10/0 manufacture. For original installation only.
Pairs: (20 minute) 4/0 x 9/0, 8/0 x 9/0
Double egress: 8/0 x 9/0 with concealed Label Authority: May be labeled and
vertical rod exit devices. classified by Warnock Hersey International
as a 20 minute fire/smoke barrier.
Thickness: 1 3/4” (± 1/16”) Restrictions on machining and architectural
accessories or application are per that
Frame Components: authority.
Stiles: (before trim or prefit) 1 3/8” mill
option kiln-dried hardwood or stiles to *Fire labeled doors may not be refit in the
match face veneer species. Bonded to the field if already factory prefit or machine
core. sized.
Rails: (before trim or prefit) 1 ¼“ mill
option kiln-dried hardwood. Bonded to
the core.

Interior Blocking: None required.

Hinges: (20 minute) 4 ½“ x 4 ½” x 0.134”


minimum or per NFPA #80 wood block core

1 1/4” hardwood top


Vision Panels: (20 minute) Maximum lite 1 3/8” hardwood
size for 20 minute fire rating, no more
1/30” back veneer
than 1296 sq in.
1/16” cross banding

Core: Staved lumber core with maximum


2 ½“ width low density wood blocks
bonded together. Manufactured to 1/30” face veneer
NWWDA 1.S-1 sections 3.2.1, 3.2.11 for
Solid Wood Block Core.

Faces: 1/8” - 3 ply cross banded


hardwood face veneer meeting AWI or 1 1/4” hardwood
NWWDA grading rules as specified. Type bottom rail
AMPCO
II bond between plys as specified. 1/30” SLC/SLC20 WOOD
face prior to sanding.

Ampco Products, Inc., 4840 NW 128 St. Rd., Opa Locka, FL 33054 TeL: 305.821.5700
AMPCO ARCHITECTURAL MC45 Wood
FLUSH WOOD DOOR SPECIFICATIONS C Label 45 Minute Fire Door
®
AWI: FD 3/4

Quality Standards: Conforms to NWWDA Assembly: 7 ply when using 3 ply hardwood
Industry Standard I.S.-1, and Architectural face veneer. Core and frame components are
Woodwork Institute section 1300-G-4 for bonded per Warnock Hersey manufacturing
Type FD ¾, ASTM E-152 fire test of door authorities and sanded to uniform thickness
assemblies as performed by Warnock of 1 ½ “ (±.015).
Hersey International.
Warranty: Lifetime from date of manufacture.
Maximum Size: Single Door: 4/0 X 10/0, For original installation only.
3/0 X 10/0 with transom.
Pairs: 8/0 X 9/0 Label Authority: Labeled and classified by
Double egress: 8/0 X 8/0 Warnock Hersey International as a 45 minute
Metal edge and astragal required on pairs. fire barrier in sizes as described above with
vision panels having aggregate areas of 1296
Thickness: 1 3/4“ (±1/16”) square inches either singularly or in
multiples.
Frame Components:
Stiles: (before trim or prefit) 1“ mill option Application Exception: Exterior application of
hardwood untreated or clear fir with a this product requires specification of Type I
minimum density of 28.75 pounds per cubic optional adhesives for construction of all door
feet (pcf) or other species having equal components including faces. This application
density. Bonded to the core. also requires additional architectural
Rails: (before trim or prefit) accessories and special finishes (see
Top: 1“ untreated hardwood or clear Architectural Accessories Details, Section V),
fir with a minimum of 28.75 pcf or and reduces the warranty period from lifetime
other species having an equal to two years.
density. Bonded to the core.
Bottom: 2“ hardwood with minimum
of 28.75 pcf or other species having
an equal density. Bonded to the core. *Fire labeled doors may not be refit in the
field if already factory prefit or machine sized.
Interior Blocking: In some applications the
addition of optional GP Firestop®
GP homogeneous mineral
composition may be required due to fire
rating and hardware specifications.
1” hardwood top rail
1” hardwood stiles
Hinges: 4½“ X 4½ ” X 0.134” minimum or
1/30” back veneer
per NFPA #80
1/16” cross banding
Core: Georgia Pacific homogenous mineral
core with minimum density of 26 pounds per
cubic foot. 1/30” face veneer

Faces: 1/8“- 3 ply cross banded hardwood


face veneer meeting AWI or NWWDA
grading rules as specified. Type II bond
between plys as specified.
2” hardwood bottom
rail
Adhesive: Type I or Type II bond, by AMPCO
specification, between faces and core/frame MC45 WOOD
components Formulated using no

Ampco Products, Inc., 4840 NW 128 St. Rd., Opa Locka, FL 33054 TeL: 305.821.5700
AMPCO ARCHITECTURAL MC60 Wood
FLUSH WOOD DOOR SPECIFICATIONS B Label 60 Minute Fire Door
®
AWI: FD 1

Quality Standards: Conforms to NWWDA Assembly: 7 ply when using 3 ply


Industry Standard I.S.-1, and Architectural hardwood face veneer. Core and frame
Woodwork Institute section 1300-G-4 for component are bonded per Warnock
type FD 1, and ASTM E-152, Fire Test of Hersey manufacturing authorities and
Door Assemblies as performed by sanded to a uniform thickness of 1 1/2” (+
Warnock Hersey International. .015”).

Maximum Size: Single Door: 4/0x10/0, Warranty: Lifetime from date of


3/0 x 10/0 with transom. manufacture. For original installation only.
Pairs: 8/0 x 9/0
Double egress: 8/0 x 8/0. Double egress is Label Authority: Labeled and classified by
larger with intumescent material. Warnock Hersey International as a 60
Metal edge and astragal required for all minute fire barrier in sizes as described
pairs. above.

Thickness: 1 3/4” (+ 1/16”) Application Exception: Exterior application


of this product requires specification of Type
Frame Components: I optional adhesives for construction of all
Stiles: (before trim or prefit) 3/4” Georgia door components including faces. This
Pacific mineral composition laminated to application also requires additional
5/8” untreated hardwood, clear fir. architectural accessories and special
Bonded to the core. finishes (see Architectural Accessories
Rails: (before trim or prefit) Details, section V), and reduces the
Top: 1” firestop composition. warranty period from lifetime to two years.
Bonded to core.
Bottom: Two 1” pieces of Georgia *Fire labeled doors may not be refit in the
Pacific mineral composition field if already factory prefit or machine
laminated together. Bonded to sized.
core.

Interior Blocking: In some applications,


GP homogeneous mineral
the addition of optional solid Georgia
Pacific firestop composition may be 1” firestop composition
required due to fire rating and hardware 3/4” composition
laminated to 5/8”
specifications. Contains no asbestos. hardwood stiles

Vision Panels: Maximum Lite size for 60 1/16” cross banding


minute fire rating - 100 sq in.
1/30” face veneer
Core: Georgia Pacific gypsum type
mineral substance with minimum density
of 26 pounds per cubic foot.

Faces: 1/8“- 3ply plywood meeting AWI


or NWWDA grading rules as specified. 2” firestop composi-
Type II bond between plys as specified. tion
AMPCO
MC60 WOOD
Adhesive: Type I or Type II bond, by
specification, between faces and
Ampco Products, Inc., 4840 NW 128 St. Rd., Opa Locka, FL 33054 TeL: 305.821.5700
AMPCO ARCHITECTURAL MC90 Wood
FLUSH WOOD DOOR SPECIFICATIONS B Label 90 Minute Fire Door
®
AWI: FD 1 1/2

Quality Standards: Conforms to NWWDA Warranty: Lifetime from date of manufacture.


Industry Standard I.S.-1 and Architectural For original installation only.
Woodwork Institute section 1300-G-4 for type
FD 1 1/2, and ASTM E-152, Fire Test of Door Label Authority: Labeled and classified by
Assemblies as performed by Warnock Hersey Warnock Hersey International as a 90 minute
International. fire barrier in sizes as described above with
vision panels having aggregate areas of 100
Maximum Size: square inches either singularly or in multiples,
Single Door: 4/0 x 10/0, 3/0 x 10/0 with or fusible link louvers having aggregate areas
transom (3/0 x 3/0 maximum transom). Must of 576 square inches either singularly or in
be installed with steel frame transom bar. multiples.
Pairs: 8/0 x 9/0. Metal edge and astragal
required for all pairs. Application Exception: Exterior application of this
Double egress: 8/0 X 8/0 with surface vertical product requires specification of Type I optional
rod exit device or concealed vertical rods. adhesives for construction of all door
components including faces.This application also
Thickness: 1 ¾” (± 1/16”) requires additional architectural accessories and
special finishes (see Architectural Accessories
Frame Components: Details, Section V), and reduces the warranty
Stiles: (before trim or prefit) 3/8” untreated period from lifetime to two years.
hardwood or clear fir laminated to 1” Georgia
Pacific mineral composition or firestop *Fire labeled doors may not be refit in the field
composition. Bonded to the core. if already factory prefit or machine sized.
Rails: (before trim or prefit)
Top: 1” firestop composition. Bonded to
core.
Bottom: Two 1” pieces of Georgia
Pacific mineral composition laminated
together. Bonded to core.

Interior Blocking: In some applications, the


addition of optional solid Georgia Pacific
Firestop® composition may be required due to
fire rating and hardware specifications.
GP homogeneous mineral

Hinges: 4 ½“ x 4 ½” x 0.134” minimum or per


1” firestop composition
NFPA #80 1” composition laminated
to 3/8” hardwood stiles
1/30” back veneer
Core: Georgia Pacific homogenous gypsum
type mineral substance with minimum density
1/16” cross banding
of 26 pounds per cubic foot.

Faces: 1/8” - 3 ply plywood meeting AWI or 1/30” face veneer


NWWDA grading rules as specified. Type II
bond between plys as specified.

Adhesive: Type I or Type II bond, by


specification, between faces and core/frame
components. Formulated using no
formaldehyde. 2” firestop composi-
tion
AMPCO
Assembly: 7 ply when using 3 ply hardwood
MC90 WOOD
face veneer. Core and frame component are
bonded per Warnock Hersey manufacturing
Ampco Products, Inc., 4840 NW 128 St. Rd., Opa Locka, FL 33054 TeL: 305.821.5700
AMPCO ARCHITECTURAL LL Wood
FLUSH WOOD DOOR SPECIFICATIONS Lead Lined
®
AWI: LL

Quality Standards: Conforms to Assembly: 7 ply when using 3 ply


NWWDA Industry Standard I.S.-1, and hardwood face feneer. Core and frame
Architectural Woodwork Institute components are bonded and uniformly
section 1300-G-3 and 1300-G-4 for sanded to a thickness of 1 ½“ (± .015).
type PC7 or FD 1/3, and ASTM E-152, Core and frame components are
Fire Test of Door Assemblies as assembled to meet or exceed 20 minute
performed by Warnock Hersey specifications.
International.
Warranty: Lifetime from date of
Maximum Size: manufacture. For original installation
Single Door: 4/0 X 7/0 only.

Thickness: 1 3/4” (± 1/16”) Label Authority: Labeled and classified


by Warnock Hersey International as a
Frame Components: 20 minute fire/smoke barrier.
Stiles: (before trim or prefit) 1 3/8” Restrictions on machining and
mill option kiln-dried hardwood or architectural accessories or application
stiles to match face veneer species. are per that authority..
Bonded to the core.
Rails: (before trim or prefit) 1 1/4“ mill *Fire labeled doors may not be refit in
option kiln-dried hardwood. Bonded the field if already factory prefit or
to the core. machine sized.

Interior Blocking: Not applicable.

Hinges: 4 ½“ x 4 ½” x 0.134”
minimum or per NFPA #80

Vision Panels: Maximum lite size 20 lead bonded to plywood

minute, no more than 1296 sq in. 1 1/2” hardwood top

1 1/2” hardwood
Core: 1/16“ thick lead sheet, full
width of core, sandwiched and boned 1/8” – 3 ply cross
to AB grade exterior plywood and banded hardwood face
veneer
securely fastened with lead bolts.

Faces and Edges: 1/8”- 3 ply cross 1/30” face


banded hardwood face veneer, 1/30”
face veneer prior to sanding.

Adhesive: Type I or Type II bond, by


1 1/2” hardwood
specification, between faces and bottom rail AMPCO
core/frame components. Formulated LL WOOD
using no formaldehyde
Ampco Products, Inc., 4840 NW 128 St. Rd., Opa Locka, FL 33054 TeL: 305.821.5700