You are on page 1of 2

epro • System III CWB Concrete or CMU Wall Waterproofing

Excellent Strength & Flexibility • Seamless • Exceptional Adhesion • Extremely Durable • Redundant Protection

System Description Ecodrain

System III CWB is a field installed composite Soil

waterproofing system that is comprised of water-


based, polymer modified asphalt (PMA) membrane
Ecoshield-EB
overlaid with an HDPE and bentonite
geomembrane and covered by an HDPE core and
polypropylene fabric drainage composite which
provides excellent resistance to chemicals and root
damage with redundant water protection. Ecoline-S

System Components

Ecoline-S or R (Interior Course): A spray fluid Excellent Strength and Chemical Resistance - the
applied, water-based polymer modified asphalt result of the unique field installed composite system
(PMA) membrane. design utilizing HDPE.
Ecoshield-EB (Middle Course): A tough HDPE and
Seamless - The highly flexible spray or fluid applied
bentonite geomembrane.
membrane forms a monolithic barrier.
Ecodrain-E (Exterior Course): A HDPE core and
non-woven polypropylene fabric drainage Exceptional Adhesion - The sprayed or fluid applied
composite or Ecodrain-S: A polypropylene core and membrane bonds tenaciously to almost any
polypropylene fabric drainage composite. substrate in almost any condition including green
concrete or a damp substrate.
Additional Information:
Self Sealing - The bentonite layers seal at any
Specification Reference - Concrete/CMU Wall penetration of the system.
Specification
Detail Drawings - Reference all WP labeled details Redundant Protection - Multiple waterproofing
protection courses and drainage plane.
Installation Guidelines - Reference 1. Waterproofing
Membrane Installation (Vertical). 2. Ecoshield
Installation. 3. Ecodrain Installation.
OF DIFFE
Product Information - Reference: Ecoline-S, Ecoline- W
OR
LD RE
N
CE
A

R, Ecoshield-E, Ecodrain-E or Ecodrain-S product


brochures.
S
FO

ON
R

TI

W a te r p r oo f i n g Sys tems EA I
R

LW ND
ORLD CO

800-882-1896 • www.eproserv.com
rev. sys3cwb_012611
B B

epro • System III CWB Concrete & CM U Walls


Epro CWB Waterproofing System Testing
Composition - Ecoline-S / Ecoshield-EB / Ecodrain-E

Tensile Strength* ......................... ASTM D-412 .... 662 psi Chemical Permeation** .... ASTM F-739 Perm Rate Perm Rate
Elongation* .................................. ASTM D-412 .... 45% Ug/cm2 ml/day
Adhesion to Concrete*** .............. ASTM C-836 .... 11 lbf/in Chlorinated Solvent
Adhesion to Film .......................... ASTM C-836 .... 28.363 lbf/in Perchloroethylene ................................... 69.4 .......... 0.0008
Puncture Resistance .................... ASTM D-1709 .. 123 lb. Trichloroethylene .................................... 89.8 .......... 0.0012
Aromatic Hydrocarbon
Soil Burial* ................................... ASTM D-4068 Benzene .................... ............................ 59.3 .......... 0.0013
Weight change ..................... See Note 1 ...... 1.2% .......... passed
Tensile Strength ................... See Note 1 ...... 9.89% ........ passed Chemical Resistance** ...... ASTM D-543 Net change
Elongation ............................ See Note 1 ...... 2.2% .......... passed
Chlorinated Solvents ......... ASTM D-882 Mod. (Less 10% pass)
Heat Aging* ................................. ASTM D-4068 Perchloroethylene
Tensile Strength .................. See Note 1 ...... 8.6% .......... passed Weight ........................ ............................ 4.1%
Elongation .......................... See Note 1 ...... 8.9% .......... passed Tensile Strength ......... ............................ 6.5%
Tricholorethylene
Environmental Stress Cracking* .. ASTM D-1693 Weight ........................ ............................ 5.4%
Failure ................................ See Note 2 ...... 620 hrs. ..... passed Tensile Strength ......... ............................ 6.0%

Oil Resistance* .......................... ASTM D-543 & Aromatic Hydrocarbon


ASTM D-412 Benzene
Weight change ..................... See Note 1 ...... 7.6% .......... passed Weight ........................ ............................. 4.1%
Tensile Strength ................. See Note 1 ...... 1.1% .......... passed Tensile Strength ......... ............................ 4.4%
Elongation .......................... See Note 1 ...... 4.4% .......... passed
Gases
Methane Transmission* .............. ASTM D-1434 Hydrogen Sulfide
See Note 3 ...... 3.70xE-15... passed Weight ........................ ............................. 0.6%
Tensile Strength ......... ............................. 0.8%
* Tests performed by SGS / US Testing
** Tests performed by TRI Environmental
*** Tests performed by Momentum Technologies

Note 1: LA requires less than 10% LD


OF DIFFE
RE
OR N
Note 2: LA requires over 500 hrs. W
CE
A

Note 3: LA requires less than 3 ml per day


S
FO

ON
R

Wa te r p r oo f i n g Sys tems
TI

EA I
R

LW ND
O RL D C O

800-882-1896 • www.eproserv.com

rev.sys3cwb_110910