Professional Documents
Culture Documents
OF CONCRETE
DEGREE OF
Masters of Technology
In
Structural Engineering
By
Jalandhar
Submitted to
Jalandhar
CERTIFICATE
Jalandhar
Date:
Jalandhar
ACKNOWLEDGEMENT
I extend my deep sense of gratitude and indebtedness to our guide Prof. Sanjeev Naval,
Jalandhar, for his kind attitude, invaluable guidance, keen interest, immense help, inspiration
I am g r a t e f u l t o him for giving a lot of freedom, encouragement and guidance, and the
Technology, Jalandhar, for providing all kind of possible help throughout for the completion
I am also thankful to the Technical Laboratory Staff of DAV institute of Engineering &
Technology, Jalandhar for helping me during the experimental work . It is a great pleasure for
understanding, unstinted support. Lastly, I thank all those who are involved directly or
CIVIL ENGINEERING
DAV , JALANDAHAR
ABSTRACT
To keep a high level of structural safety, durability and performance of the infrastructure in
each country, an efficient system for early and regular structural assessment is urgently
required. The quality assurance during and after the construction of new structures
and after reconstruction processes and the characterisation of material properties and damage
as a function of time and environmental influences is more and more becoming a serious
concern.
Non-destructive testing (NDT) methods have a large potential to be part of such a system.
NDT methods in general are widely used in several industry branches. Aircrafts, nuclear
facilities, chemical plants, electronic devices and other safety critical installations are tested
regularly with fast and reliable testing technologies. A variety of advanced NDT methods are
In recent years, innovative NDT methods, which can be used for the assessment of existing
structures, have become available for concrete structures, but are still not established for
regular inspections. Therefore, the objective of this project is to study the applicability,
The purpose of establishing standard procedures for nondestructive testing (NDT) of concrete
structures is to qualify and quantify the material properties of in-situ concrete without
intrusively examining the material properties. There are many techniques that are currently
being research for the NDT of materials today. This chapter focuses on the NDT methods
Structures are assemblies of load carrying members capable of safely transferring the
superimposed loads to the foundations. Their main and most looked after property is the
strength of the material that they are made of. Concrete, as we all know, is an integral
material used for construction purposes. Thus, strength of concrete used, is required to be
‘known’ before starting with any kind of analysis. In the recent past, various methods and
techniques, called as Non-Destructive Evaluation (NDE) techniques, are being used for
specimens without the destruction of neither the specimen nor the structure from which it is
taken. However, one problem that has been prevalent within the concrete industry for years is
that the true properties of an in-place specimen have never been tested without leaving a
certain degree of damage on the structure. For most cast-in-place concrete structures,
construction specifications require that test cylinders be cast for 28-day strength
determination.
Usually, representative test specimens are cast from the same concrete mix as the larger
structural elements. Unfortunately, test specimens are not an exact representation of in-situ
concrete, and may be affected by variations in specimen type, size, and curing procedures.
Keeping in view the development phase in construction around us, it is appropriate time to
highlight the shortcomings of destructive tests. The quality of construction can only be
The rebound hammer test is classified as a hardness test and is based on the principle that the
rebound of an elastic mass depends on the hardness of the surface against which the mass
impinges. The energy absorbed by the concrete is related to its strength. There is no unique
relation between hardness and strength of concrete but experimental data relationships can be
obtained from a given concrete. However, this relationship is dependent upon factors
which can be used as well for strength estimation of concrete structures. The direct
determination of the strength of concrete implies that concrete specimens must be loaded to
taken, shipped, and tested at laboratories. This procedure may result in the actual strength of
concrete, but may cause trouble and delay in evaluating existing structures.
Because of that, special techniques have been developed in which attempts were made to
measure some concrete properties other than strength, and then relate them to strength,
durability, or any other property. Some of these properties are hardness, resistance to
ultrasonic pulses to propagate through concrete. Concrete electrical properties, its ability to
absorb, scatter, and transmit X-rays and gamma rays, its response to nuclear activation, and
its acoustic emission allow us to estimate its moisture content, density, thickness, and its
cement content. However, the term “nondestructive” is given to any test that does not damage
or affect the structural behavior of the elements and also leaves the structure in an acceptable
monitor basic initial cracking of concrete structures and hence to introduce a threshold limit
for possible failure of the structures. Experiments using ultrasonic pulse velocity tester have
been carried out, under laboratory conditions, on various concrete specimens loaded in
compression up to failure.
LITERATURE SURVEY
Compared with the development of nondestructive test (NDT) methods for steel structures,
the development of NDT methods for concrete has progressed at a slower pace, because
concrete is inherently more difficult to test than steel. Concrete is highly heterogeneous, it is
and it is often used in thick members. Thus, it has not been easy to transfer NDT technologies
developed for steel to the evaluation of concrete. In addition, there has been little interest
among those from the traditional NDT community (physicists, electrical engineers,
mechanical engineers) to develop test methods for concrete. Since the 1980s, however,
advances have occurred as a result of the microcomputer revolution and the development of
as applied to concrete. For some people, it is any test that does not alter the concrete. For
others, it is a test that does not impair the function of a structure, in which case the drilling of
cores is considered to be a NDT test. For still others, it is a test that does less damage to the
structure than does drilling of cores. This presentation deals with methods that either do not
alter the concrete or that result in only superficial local damage. In this presentation various
(2) those whose main purpose is to evaluate conditions other than strength—that is, to
evaluate integrity.
It will be shown that the most reliable tests for strength are those that result in superficial
local damage, and this presentation prefers the term in-place tests for this group. The integrity
methods for concrete. Emphasis is placed on the principles underlying the various methods so
Some of the first methods to evaluate the in-place strength of concrete were adaptations of
the Brinell hardness test for metals, which involves pushing a high-strength steel ball into the
test piece under a given force and measuring the area of the indentation. In the metals test, the
load is applied by a hydraulic loading system. Modifications were required to use this type of
test on a concrete structure. In 1934, Professor K. Gaede in Germany reported on the use of a
spring-driven impactor to supply the force to drive a steel ball into the concrete (Malhotra,
1976). A nonlinear, empirical relationship was obtained between cube compressive strength
pistol-shaped device in which a 4-mm ball was attached to a plunger (Malhotra, 1976). The
spring was compressed by turning a screw, a trigger released the compressed spring, and the
plunger was propelled toward the concrete. The diameter of the indentation produced by the
ball was measured with a magnifying glass and scale. In 1938, a landmark paper by D.G.
Skramtajev, of the Central Institute for Industrial Building Research in Moscow, summarized
14 different techniques for estimating the in-place strength of concrete, 10 of which were
The various NDT methods for testing concrete are listed below –
A. For strength estimation of concrete
(iii) Combined use of Ultrasonic Pulse Velocity tester and rebound hammer test
(v) Profometer
- response method
2.2(a) Strength determination by NDE methods:
Strength determination of concrete is important because its elastic behavior & service
behavior can be predicted from its strength characteristics. The conventional NDE methods
typically measure certain properties of concrete from which an estimate of its strength and
other characteristics can be made. Hence, they do not directly give the absolute values of
strength.
Global techniques: These techniques rely on global structural response for damage
identification. Their main drawback is that since they rely on global response, they are not
sensitive to localized damages. Thus, it is possible that some damages which may be present
Local techniques: These techniques employ localized structural analysis, for damaged
detection
Their main drawback is that accessories like probes and fixtures are
required to be physically carried around the test structure for data recording. Thus, it no
longer remains autonomous application of the technique. These techniques are often applied
at few selected locations, by the instincts/experience of the engineer coupled with visual
Visual inspection: The first stage in the evaluation of a concrete structure is to study the
condition of concrete, to note any defects in the concrete, to note the presence of cracking and
the cracking type (crack width, depth, spacing, density), the presence of rust marks on the
surface, the presence of voids and the presence of apparently poorly compacted areas etc.
The Surface hardness method: This is based on the principle that the strength of concrete is
proportional to its surface hardness. The calibration chart is valid for a particular type of
cement, aggregates used, moisture content, and the age of the specimen.
The penetration technique: This is basically a hardness test, which provides a quick means
of determining the relative strength of the concrete. The results of the test are influenced by
surface smoothness of concrete and the type and hardness of the aggregate used. Again, the
calibration chart is valid for a particular type of cement, aggregates used, moisture content,
and age of the specimen. The test may cause damage to the specimen which needs to be
repaired.
The pull-out test: A pullout test involves casting the enlarged end of a steel rod after setting
of concrete, to be tested and then measuring the force required to pull it out. The test
measures the direct shear strength of concrete. This in turn is correlated with the compressive
strength; thus a measurement of the in-place compressive strength is made. The test may
The rebound hammer test: The Schmidt rebound hammer is basically a surface hardness
test with little apparent theoretical relationship between the strength of concrete and the
rebound number of the hammer. Rebound hammers test the surface hardness of concrete,
which cannot be converted directly to compressive strength. The method basically measures
the modulus of elasticity of the near surface concrete. The principle is based on the
absorption of part of the stored elastic energy of the spring through plastic deformation of the
rock surface and the mechanical waves propagating through the stone while the remaining
elastic energy causes the actual rebound of the hammer. The distance travelled by the mass,
expressed as a percentage of the initial extension of the spring, is called the Rebound number.
There are several factors other than concrete strength that influence rebound hammer test
results, including surface smoothness and finish, moisture content, coarse aggregate type, and
the presence of carbonation. Although rebound hammers can be used to estimate concrete
strength, the rebound numbers must be correlated with the compressive strength of molded
Ultra-sonic pulse velocity test: This test involves measuring the velocity of sound through
concrete for strength determination. Since, concrete is a multi-phase material, speed of sound
compacting, moisture content, and the amount of discontinuities present. This technique is
applied for measurements of composition (e.g. monitor the mixing materials during
homogeneity, elastic modulus and age, & to check presence of defects, crack depth and
thickness measurement. Generally, high pulse velocity readings in concrete are indicative of
concrete of good quality. The drawback is that this test requires large and expensive
transducers. In addition, ultrasonic waves cannot be induced at right angles to the surface;
Acoustic emission technique: This technique utilizes the elastic waves generated by plastic
deformations, moving dislocations, etc. for the analysis and detection of structural defects.
However, there can be multiple travel paths available from the source to the sensors. Also,
electrical interference or other mechanical noises hampers the quality of the emission signals.
Impact echo test: In this technique, a stress pulse is introduced at the surface of the structure,
and as the pulse propagates through the structure, it is reflected by cracks and dislocations.
Through the analysis of the reflected waves, the locations of the defects can be estimated.
The main drawback of this technique is that it is insensitive to small sized cracks.
3.
CONCRETE
The operation of rebound hammer is shown in the fig.1. When the plunger of rebound
hammer is pressed against the surface of concrete, a spring controlled mass with a constant
energy is made to hit concrete surface to rebound back. The extent of rebound, which is a
designated as Rebound Number (rebound index). A concrete with low strength and low
IS 13311 Part-II – 1992 and BS 6089-81 and BS: 1881: Part-204 explains the standard
procedure for test and correlation between concrete cube crushing and strength rebound
1. Cement type
2. Cement content
c) Member characteristics
1. Mass
2. Compaction
3. Surface type
4. Age, rate of hardening and curing type
5. Surface carbonation
6. Moisture condition
7. Stress state and temperature
oncrete strength will be valid only if they are all standardised for the concrete under test and
A) Strength Assessment
This test is conducted to assess the relative strength of concrete based on the hardness at or
near its exposed surface. Carrying of periodic calibration of rebound hammer using standard
anvil is desirable. However for new concrete construction, rebound hammer is calibrated on
concrete test cubes for a given source of constituent materials (i.e. cement, sand, stone
aggregates), this calibration data can be used with reasonable accuracy In arriving at
equivalent in-situ cube strength of relatively new concrete (not more than three months old
concrete. This calibration exercise may be carried out in a concrete lab by casting cubes of
designed mix and testing these under controlled condition with rebound hammer as well as
test to destruction in compression. Calibration graphs then can be drawn. Large number of
readings are desirable to reduce the affects of variability in readings due to various localized
as well as instrument factors. This method may give highly erroneous results for concrete
whose surface is exposed to atmosphere for longer periods say more than three months. This
is due to hardening of concrete surface due to carbonation, which may cause overestimation
as much as 50% for old structure. Hence strength assessment by rebound hammer test should
Comparative Hardness
Procedure
i) Before commencement of a test, the rebound hammer should be tested against the test
anvil, to get reliable results, for which the manufacturer of the rebound hammer indicates the
range of readings on the anvil suitable for different types of rebound hammer.
ii) Apply light pressure on the plunger – it will release it from the locked position and allow it
iii) Press the plunger against the surface of the concrete, keeping the instrument perpendicular
to the test surface. Apply a gradual increase in pressure until the hammer impacts. (Do not
touch the button while depressing the plunger. Press the button after impact, in case it is not
homogeneity and integrity of concrete. With this technique, following can be assessed:
2. Any discontinuity in cross section like cracks, cover concrete delamination etc.
produced by an electro-acoustical transducer, held in contact with one surface of the concrete
member under test and receiving the same by a similar transducer in contact with the surface
at the other end. With the path length L, (i.e. the distance between the two probes) and time
of travel T, the pulse velocity (V=L/T) is calculated (fig.2). Higher the elastic modulus,
density and integrity of the concrete, higher is the pulse velocity. The ultrasonic pulse
velocity depends on the density and elastic properties of the material being tested.
Though pulse velocity is related with crushing strength of concrete, yet no statistical
a) Path length
20mm size aggregate is used or less than 150mm for 40mm size aggregate. Pulse velocity
will not be influenced by the shape of the specimen, provided its least lateral dimension (i.e.
its dimension measured at right angles to the pulse path) is not less than the wavelength of the
pulse vibrations. For pulse of 50Hz frequency, this corresponds to a least lateral dimension of
about 80mm. the velocity of pulses in steel bar is generally higher than they are in concrete.
For this reason pulse velocity measurements made in the vicinity of reinforcing steel may be
high and not representative of the concrete. The influence of the reinforcement is generally
small if the bars runs in a direction at right angles to the pulse path and the quantity of steel is
small in relation to the path length. The moisture content of the concrete can have a small but
significant influence on the pulse velocity. In general, the velocity is increased with increased
moisture content, the influence being more marked for lower quality concrete.
Fig.1: Method of propagating and receiving pulses
structure provides a reliable method of assessing the homogeneity of the concrete. The size of
the grid chosen will depend on the size of the structure and the amount of variability
encountered.
Table: 1 – General Guidelines for Concrete Quality based on UPV
Table 1 shows the guidelines for qualitative assessment of concrete based on UPV test
member, the pulse velocity can be combined with rebound number. Table 2 shows the
guidelines for identification of corrosion prone locations by combining the results of pulse
Table:2 – Identification of Corrosion Prone Location based on Pulse Velocity and Hammer
Readings
rebound number
2 Medium range UPV values, Surface delamination, low quality of surface
Detection of Defects
When ultrasonic pulse travelling through concrete meets a concrete-air interface, there is a
negligible transmission of energy across this interface so that any air filled crack or void
lying directly between the transducers will obstruct the direct beam of ultrasonic when the
void has a projected area larger than the area of transducer faces. The first pulse to arrive at
the receiving transducer will have been directed around the periphery of the defect and the
An estimate of the depth of a crack visible at the surface can be obtained by the transit times
across the crack for two different arrangements of the transducers placed on the surface. One
suitable arrangement is one in which the transmitting and receiving transducers are placed on
opposite sides of the crack and distant from it. Two values of X are chosen, one being twice
that of the other, and the transmit times corresponding to these are measured. An equation
may be derived by assuming that the plane of the crack is perpendicular to the concrete
surface and that the concrete in the vicinity of the crack is of reasonably uniform quality. It is
important that the distance X be measured accurately and that very good coupling is
developed between the transducers and the concrete surface. The method is valid provided
i) Preparing for use: Before switching on the ‘V’ meter, the transducers should be connected
b) an external battery or
ii) Set reference: A reference bar is provided to check the instrument zero. The pulse time
for the bar is engraved on it. Apply a smear of grease to the transducer faces before placing it
on the opposite ends of the bar. Adjust the ‘SET REF’ control until the reference bar transit
iii) Range selection: For maximum accuracy, it is recommended that the 0.1 microsecond
iv) Pulse velocity: Having determined the most suitable test points on the material to be
tested, make careful measurement of the path length ‘L’. Apply coolant to the surfaces of the
transducers and press it hard onto the surface of the material. Do not move the transducers
while a reading is being taken, as this can generate noise signals and errors in measurements.
Continue holding the transducers onto the surface of the material until a consistent reading
appears on the display, which is the time in microsecond for the ultrasonic pulse to travel the
distance ‘L’. The mean value of the display readings should be taken when the units digit
v) Separation of transducer leads: It is advisable to prevent the two transducer leads from
coming into close contact with each other when the transit time measurements are being
taken. If this is not done, the receiver lead might pick-up unwanted signals from the
transmitter lead and this would result in an incorrect display of the transit time.
The necessity to provide adequate cover thickness to control corrosion needs no emphasis. A
cover thickness survey is useful to determine existing cover thickness in a specified location,
where a damage has been identified and elsewhere, for comparison on the same structure.
The cover thickness can be measured non-destructively using commercially known cover
meters. The cover meters are also used to identify the location and diameter of rebar:
used to measure the cover thickness and rebar size. Table 1 shows how the cover reading are
concrete prone
2 Required cover thickness and bad quality Corrosion prone
concrete cover
3 Very less cover thickness yet good quality Corrosion prone
cover concrete
Corrosion being an electrochemical phenomenon, the electrode potential of steel wire with
A schematic survey on well-defined grid points gives useful information on the presence or
probability of corrosion activity. The same grid points are used for other measurements,
namely, rebound hammer and UPV could be used for making the data more meaningful. The
The measurement consists of giving an electrical connection to the rebar and observing the
voltage difference between the bar and a reference electrode in contact with concrete surface.
(Fig. 1. (a)) Generally the voltage potential becomes more and more negative as the corrosion
becomes more and more active. However less negative potential values may also indicate the
The general guidelines for identifying the probability of corrosion based on half cell potential
measurements of chloride content of the concretes and its variation with depth and also the
However, a systematic “potential mapping survey” is considered to be more useful for on-site
identification of the Corrosion State of rebars. This will facilitate setting out potential profile
or potential contour. A typical potential contour is shown in fig.1 (b) and (c). initially when
potential surveying was introduced as per ASTM C 876, each reading was interpreted in
isolation and the numerical value was directly correlated to the fegree of corrosion.
Subsequently, this approach was realised to be erroneous because non-corroded steel can
exhibit a wide range of potential values. It is now realised that potential values should be
assessed not in isolation but as a group and the inter relationship of the potentials within a
group should form the basis of interpretation. Analysis of potential contour will generally
consist of indenfying the locatins with accumulated potential lines indicating to the corroding
areas beneath.
(b) Shaded Mapping
· Locating at a glance, the anodic areas identified by the gathering of isopotential lines having
It is necessary to realise certain important parameters (listed below) which influence the
1. The potentials of rebar measured on the surface of, or within concrete may not be a
2. The physical i.e. moisture content and chemical state of concrete i.e. presence of
3. The ohmic drop due to electrical resistance of the concrete also can induce variations
4. With increased concrete cover, the potential values at the concrete surface over
1. Resistivity Measurement
Resistivity Mapping:
The electrical rsistance of concrete plays an important role in determining the quality of
concre from the point of view ‘corrosion susceptibility potential’ at any specific location.
For general monitoritng, a resistivity check is important because long-term corrosion can be
anticipated in concrete structures where accurately measured values are below 10000 ohm-
cm. further if resistivity values fall below 5000 ohm-cm, corrosion must be anticipated at a
much earlier period (possibly within 5 years) in the life of a structure. Table 2 indicates the
general guidelines of resistivity values based on which areas having probable corrosion risk
The principle of resistivity testing in concrete is similar to that adopted in soil testing.
However when applied in concrete, a few drawbacks should be realised. The method
essentially consists of using a 4-probe technique in which a known current is applied between
two outer probes 100 mm apart and the voltage drop between the inner two elements at
50mm spacing is read off allowing for a direct evaluation of resistance, R. Using a
The following drawbacks are important to note while analysing and interpreting the
resistivity values:
The value obtained represents only the average evaluation over the depth regulated by
the chosen probe spacing and not that of concrete at steel interface.
corroding assumes larger importance since the laboratory results are not directly applicable to
field conditions. Another form of the polarization method has been developed and is known
as Linear Polarisation Resistance (LPR) method for the on-site study of corrosion rates of
experimentally observed assumption that for a simple model corroding system, the
polarization curve for few milivolts around the corrosion potential obeys a quasi-linear
From this slope, the corrosion rate can be determined using stern-Geary equation
Where B is a constant which is a function of the Tafel slopes and ba, bc and determined from
The value of B usually lies between 13 and 52 mV depending on the passive and active
corroding system. For on-site measurements, the testing system consists of a potentiostat,
counter electrode, reference electrode and the reinforcement as working electrode. This
A typical plot of linear polarization curve is shown in fig.4.It is necessary that for
measurements in concrete, the potentiostat should have electronic ohmic compensation (IR
drop) or otherwise, the valies to be obtained by calculation or separate experiments.
situ Test)
- Thickness of cover concrete
- Reinforcement diameter
- Reinforcement spacing
2 Half Cell Method (in-situ Non-destructive method for
b) Air
5 Initial surface absorption (Lab An indicator of surface permeability
Test)
Half cell potential measurement method is used for finding out the status of corrosion
powder actuated driver, hardened alloy of probe, loaded cartridges, a depth gauge and other
accessories. In this technique a gunpowder actuated driver is used to fire a hardened alloy
probe into the concrete. During testing, it is the exposed length of probe which is measured
terms of depth of penetration as the fundamental relation is between concrete strength and
penetration depth.
The probe shown in fig.1 has a diameter of 6.3mm, length of 73mm and conical point at the
tip. The rear of the probe is threaded and screwed into a probe-driving head, which is
12.6mm in diameter and fits snugly along with a rubber washer into the bore of the driver. As
the probe penetrates into the concrete, test results are actually not affected by local surface
conditions such as texture and moisture content. However damage in the form of cracking
may be cause to slender members. A minimum edge distance and member thickness of
150mm is required. It is important to leave 50mm distance from the reinforcement present in
the member since the presence of reinforcing bars within the zone of influence of penetrating
A pin penetration test device (PNR Tester) which requires less energy than the Windsor
recommended for testing concrete having strength above 28 N/sq.mm. in this a spring-loaded
device, having energy of about 1.3% of that of Windsor probe, us used to drive 3.56mm
diameter, a pointed hardened steel pin into the concrete. The penetration of pin creates a
small indentation (or hole) on the surface of concrete. The pin is removed from the hole, the
hole is cleaned with an air jet and the hole depth is measured with a suitable depth gauge.
Each time a new pin is required as the pin gets blunted after use.
The strength properties of both mortar and stone aggregate influence the penetration depth of
the probe in a concrete, which is contrastingly different than cube crushing strength, wherein
the mortar strength predominantly governs the strength. Thus the type of stone aggregate has
a strong effect on the relation of concrete strength versus depth of penetration as given in
fig.3.
Fig.3: Effect of aggregate type on relationship between concrete strength and depth of probe
penetration
For two samples of concrete with equal cube crushing strength, penetration depth would be
more in the sample with softer aggregate than the one with harder aggregates. Correlation of
from laboratory test on specific concrete with particular type of aggregates. Aggregate
hardness is determined from standard samples provided along with the instrument. Aggregate
size in the mix also influence the scatter of individual probe readings. This technique offers a
means of determining relative strength of concrete in the same structure or relative strength of
different structures. Because of the nature of equipment it can not and should not be expected
to yield absolute values of strength. This test is not operator independent although verticality
of bolt relative to the surface is obviously important and safety device in the driver prevents,
if alignment is poor.
test equipment designed to a specific geometry will produce results (pull-out forces) that
measuring the force required to pull a steel disc or ring, embedded in fresh concrete, against a
circular counter pressure placed on the concrete surface concentric with the disc/ring.
For hardened concrete, an expandable steel ring is used instead. This ring expands to fit a
specially drilled hole and routed recessin the concrete. The first method, shown in figure 1
using the cast steel disc is called LOK test. The second method shown in fig.2 using
expandable ring is called CAPO test (i.e. Cut and Pull out Test). The diameter of both the
disc and ring is 25mm. the distance to the concrete surface is also 25mm. the inner diameter
The relationship between the pullout force Fu in kN and compressive strength Fc in MPa is
given in fig.3.
Fig.3: Typical Pull out Force Calibration Chart
By measuring the pull-out force of a cast-in disc or expanded ring, the compressive strength
of in-situ concrete can be determined from the relationship in fig.4 to a great degree of
confidence.
Fig.4: Pull off force compressive strength relationship
The pullout test produces a well defined in the concrete and measure a static strength
As the insert is pulled out, a roughly cone shaped fragment of the concrete is extracted. The
calibration curves, prepared based on laboratory and field tests conducted on concrete cubes
and pull out samples cast with various grades of concrete. In the test assembly, the
embedment depth and insert head diameter have to be equal with inner diameter of the
reaction ring could vary between 2 to 2.4 times the diameter of the insert head. The apex of
the conic frustum defined by the insert-head diameter and the inside diameter of the reaction
ring can vary between 54 degree and 70 degree. The compressive strength can be considered
as proportional to the ultimate pullout force. The reliability of the test is reported as good.
Since the embedment depths of the commercially available metallic inserts is of the order of
25 to 30mm, the test results cover a small portion of the near surface concrete located
adjacent to the fractured surface and below the reaction ring. Thus due to the inherent
pullout tests has been found to be in the range of 7 to 10% which is better than that of
standard cube/cylinder compression test. It is superior to rebound hammer and Windsor probe
test because of greater depth of concrete volume tested. This is not affected by type of cement
and aggregate characteristics. However this test is not recommended for aggregates beyond
size of 38mm. the major limitation of this test is that it requires special care at the time of
placement of inserts to minimize air void below the disc besides a pre-planned usage.
2. Ascertain the strength of concrete for carrying out post tensioning operations.
3. Determine the time of removal of forms and shores based on actual in-situ strength of
the structure.
Here item No.(i) only are of relevance for residual strength assessment of old and distressed
structures. It can be also used for testing repaired concrete sections. These tests are divided
a) Embedding an insert into the fresh concrete while casting and then pulling out with a jack
(LOK test – LOK meaning ‘punch’) after hardening after a specified period.
b) Insert fixed into a hole drilled into the hardened concrete and then pulling out with a jack
(CAPO test- cut and pull out test). This second method offers greater flexibility for
conducting in-situ tests on hardened concrete of existing structures and is explained above in
detail.
After the concrete has fractured by this test, the holes left in the surface are first cleaned of
the dust by a blower. It is then primed with epoxy glue and the hole is filled with a polymer-
3.6 RADIOGRAPHY:
This technique enables to take a photograph showing details of the inside of a concrete
member. It is used to determine the location and size of reinforcement, to check for the
existence of voids and areas of poor compaction in concrete where other NDE tests methods
are not suitable, such as massive old concrete structural members when being assessed for
structural safety. It is also used for checking for voids in the grouting in prestressing ducts.
of concrete.
This method uses sources of gamma rays for concrete upto about 500 mm thick and above
this thickness, the standard recommends the use of high energy X-rays.
Due to the inherent danger of using gamma rays and high energy X-rays, the use of this
method is confined to investigation which justify the cost of the special precautions which
have to be taken.
Impact – echo Test:
Most often non – destructive evaluation technique based on use of transient stress waves, has
been used for detecting flaws in many different types of structures including plate like
structures such a bridge decks, slabs and walls beams and columns, layered structures and
hollow cylindrical structures. To detect hidden damage and determine the extent of damage
The dynamic characteristics of structures depend on its stiffness and mass. Frequency of a
dynamic testing of a structure before and after repairs will give an idea of the deterioration of
structures and effectiveness of the repairs. The different techniques available for dynamic
1. Frequency Shift: The method is base on the comparison of the natural frequency of
the damaged structure with the undamaged structure. In the absence of the knowledge
theoretical computations. Care should be taken for the non-structural member on the
frequency. The frequency being a global property of a structure, this method can not
2. Mode – Shape Change: The change in mode shape is more sensitive to damage than
the frequency. The damage location using mode shape can be done without prior
can be synthesized using the frequency and mode shape in various modes. The
structure can indicate the damage. The same comparison before and after the repairs
In addition to the above mentioned techniques a few techniques are available for
continuous /periodic health monitoring of a structure. The problem with dynamic testing is
the absence of the knowledge of the undamaged structure. However, the testing can be very
useful in assessing the effectiveness of repairs, as the testing can be done before and after the
repairs.
The conventional testing of control cubes can be at the best indicate the potential quality of
concrete assuming that the composition is same as that going into the structure. Two more
steps compaction & curing, can be different from cubes & the structure. So the use of NDT
can give a better understanding of the quality of concrete in its final position.
Another great advantage is possibility of repeating the NDT in case of any doubt. This is not
These methods are basically applicable to both metals as well as nonmetals. However in
general emphasis in the case of metals is on locating the local defects or discontinuities, in
case of concrete on the other hand , the emphasis is on estimating the gross properties or
quality of concrete . This is because the concrete is always full of features that can be called
as defects.
From the basic of structure of the material it can be expected that any change in one property
should affect all others properties as well .This is the main reason why indirect tests are
useful. In other words, it is desirable to determine the quality of the entire volume of concrete
in terms of the property required for the end use, strength in general. This is not just possible
using conventional destructive tests. With NDT, it is possible to cover the entire volume with
appropriate tests.
When estimating , say strength from any of the NDT methods, the question of accuracy is
always raised .With a proper correlation , it may be possible to get the results well, within
15% .In difficult situations also, it would still be possible to estimate the results within about
25% accuracy.
CONCLUSION
Considerable engineering judgment is needed to properly evaluate a measurement.
Misinterpretation is possible when poor contact is made. For example, in some cases it may
not be possible to identify severely corroded reinforcing bar in poor quality concrete.
However, it is possible to identify poor quality concrete which could be the cause of
reinforcing bar problems. The poor quality concrete allows the ingress of moisture and
oxygen to the reinforcing bars, and hence corrosion occurs. Presently the system is limited to
penetration depths of 1 ft. Research is ongoing to develop a system that can penetrate to a
depth of 10 ft or more.
When variation in properties of concrete affect the test results, (especially in opposite
directions), the use of one method alone would not be sufficient to study and evaluate the
required property. Therefore, the use of more than one method yields more reliable results.
For example, the increase in moisture content of concrete increases the ultrasonic pulse
velocity but decreases the rebound number . Hence, using both methods together will reduce
the errors produced by using one method alone to evaluate concrete. Attempts have been
done to relate rebound number and ultrasonic pulse velocity to concrete strength.
The Schmidt hammer provides an inexpensive, simple and quick method of obtaining an
indication of concrete strength, but accuracy of ±15 to ±20 per cent is possible only for
specimens cast cured and tested under conditions for which calibration curves have been
established. The results are affected by factors such as smoothness of surface, size and shape
of specimen, moisture condition of the concrete, type of cement and coarse aggregate, and
The pulse velocity method is an ideal tool for establishing whether concrete is uniform. It can
Usually, if large differences in pulse velocity are found within a structure for no apparent
reason, there is strong reason to presume that defective or deteriorated concrete is present.
Fairly good correlation can be obtained between cube compressive strength and pulse
velocity. These relations enable the strength of structural concrete to be predicted within ±20
per cent, provided the types of aggregate and mix proportions are constant.
In summary, ultrasonic pulse velocity tests have a great potential for concrete control,
particularly for establishing uniformity and detecting cracks or defects. Its use for predicting
strength is much more limited, owing to the large number of variables affecting the relation
The deviation between actual results and predicted results may be attributed to the fact that
samples from existing structures are cores and the crushing compressive cube strength was
were not accurate and representative when compared to the cubes used to construct the plots.
The use of the combined methods produces results that lie close to the true values when
compared with other methods. The method can be extended to test existing structures by
Unlike other work, the research ended with two simple chart that requires no previous
knowledge of the constituents of the tested concrete. The method presented is simple, quick,
reliable, and covers wide ranges of concrete strengths. The method can be easily applied to
concrete specimens as well as existing concrete structures. The final results were compared
with previous ones from literature and also with actual results obtained from samples
REFERENCES
Rebound hammer.
concrete structures.
8. Civil Engineering Construction Review, August 1998 Edition ( Non Destructive Testing of
Concrete ).
Christiane Maierhofer Federal Institute for Materials Research and Testing (BAM), D-12205
Berlin, Germany .
11. The use of USPV to anticipate failure in concrete under compression Hisham Y. Qasrawi
International
3. ASTM C 805-85, Test for Rebound Number of Hardened Concrete, ASTM, USA (1993).
4. BS 1881: Part 202, 1986: Recommendations for Surface Hardness Tests by the Rebound
6. T. Akashi and S. Amasaki, Study of the stress waves in the plunger of a rebound hammer
at the time of impact. In: V.M. Malhotra, Editor, In situ/Nondestructive Testing of Concrete,
Hardened Concrete, FHWA Public Roads 30 (1958), pp. 45–50 Washington, DC, No. 2,
June.
267, U.S. Army Engineer Waterways Experiment Station, Vicksburg, MS (1958) June.
11. G. Teodoru, The use of simultaneous nondestructive tests to predict the compressive
strength of concrete. In: H.S. Lew, Editor, Nondestructive Testing vol. 1, ACI, Detroit (1988),
13. ASTM C 597-83 (Reapproved 1991), Test for Pulse Velocity Through Concrete, ASTM,
USA(1991).
14. BS 1881: Part 203: 1986: Measurement of Velocity of Ultrasonic Pulses in Concrete,
BSI,UK (1986).
15. A. Nilsen and P. Aitcin, Static modulus of elasticity of high strength concrete from pulse
16. R. Philleo, Comparison of results of three methods for determining Young's modulus of
17. M. Sharma and B. Gupta, Sonic modulus as related to strength and static modulus of high
18. ACI 318-95, Building Code Requirements for Structural Concrete (ACI 318-95) and
19. E. Whitehurst, Soniscope tests concrete structures. J Am Concr Inst 47 (1951), pp. 433–
444 Feb..
20. R. Jones and E. Gatfield. Testing Concrete by an Ultrasonic Pulse Technique, DSIR Road
Research Tech. Paper No. 34, HMSO, London (1955).
21. C. Yun, K. Choi, S. Kim and Y. Song, Comparative evaluation of nondestructive test
methods for in-place strength determination. In: H.S. Lew, Editor, Nondestructive Testing,