3. Size Transformer
Zone 1 2 3 4
Thermostat Load
Transformer
Floating Control must exceed:
Zone Valve Load
Action (VA) Load (VA)
Total Zone Load + + + + + 2 VA
Strip wires
1/2 inch (13 mm).
Installed wires are
not removable.
Boil (black) 12-18 AWG
Sensor with rear Sensor with bottom Sensor mounted Boil System Pump
entry wiring entry wiring onto 2" x 4"
electrical box (black)
DHW DHW Pump
Pipe Sensors
Retaining Clip
(red)
Universal Pump Power L
Sensor 082
N L
to pump grounds
N LG
Sensor Well
115 V (ac)
Made in Canada tN2 tN2 tN2 tN2 tN2 tN2 tN2 tN2
Zone 1 Zone 2 Zone 3 Zone 4
Outdoor
Sensor Boiler Supply
Sensor 082
Com Boil Out Com DHW
070
Sensors - No Power
tekmarNet ®4
Stage 2 Mod dc/mA Boil Exp.
C
tN4 C
tN4 Boil
Expansion Expansion to
tN4
Wiring Centers,
DHW Tank Timers, or
—
Modulating
Sensor 082 Boiler User Switch
+
+
Setpoint
Call
Stage 1
Call
DHW Call
from DHW R L
Tank Aquastat C N
(optional)
Zone Valves
24 V (ac) Transformer 009
8. Install Cover
Menu
Item
House Co
ntrol 402
Symbols
CALLS WWSD
Calls Displays any call for heat the control is WWSD Displays when the system is in Warm
receiving. Weather Shut Down.
PUMPS
°F°C °F, °C, %, HOURS, MINUTES, SECOND
Pumps Displays any pump currently operating.
minhr Units of measurement for current number.
sec%
UNOCCUPIED
Zones ZONES
Indicates that a User Switch or Timer has
1234 Displays if an on-board zone is operating.
put the system into UnOccupied.
BOILER
WARNING
Indicates that the boiler should be
Displays if an error exists on the system.
heating.
ENERGY SAVING INDICATOR MIN / MAX
Saving Displays when the system is saving MINMAX Displays when an operating temperature
energy. See the Saving Indicator section. reaches a minimum or maximum value.
ACCESS LEVEL
INST (Installer) Selects the Access Level of the control, which determines the Menu items
available. USER provides the most limited level of access and shows
or USER
the fewest possible items.
Default = INST
When set to USER, all thermostats are locked and the number of
thermostat settings available are reduced.
Press menu button until the Adjust Menu is displayed. Press item
button to locate the desired setting.
BOILER TYPE
EMS2, The type of boiler connected to the control.
EMS1, 1STG = single one-stage on-off boiler
4-20 2STG = single two-stage on-off boiler
0-10, Installer 0-10 = 0-10 V (dc) modulating boiler
2STG, 4-20 = 4-20 mA modulating boiler
1STG EMS1 = tekmar boiler staging controls
Default = 1STG EMS2 = Viessmann modulating boilers with
OpenTherm
BOILER DESIGN
The supply water temperature required for the boiler
zones to heat the building on the typical coldest day
VIEW
70 to 200°F of the year. Recommendations:
(21.0 to 93.5°C) High mass radiant floor = 120°F (50°C)
Installer Low mass radiant floor = 140°F (60°C)
Default = 180°F
(82.0°C) Fancoil or air handling unit = 190°F (90°C)
Copper fin-tube convector = 180°F (80°C)
Radiators = 160°F (70°C)
Low profile baseboard = 150°F (65°C)
tekmar Control Systems Ltd., Canada, tekmar Control Systems, Inc., U.S.A. Head Office: 5100 Silver Star Road,
Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarcontrols.com
Product design, software and literature are Copyright © 2010 by: All specifications are subject to change without notice.
tekmar Control Systems Ltd. and tekmar Control Systems, Inc.
4 of 4 Printed in Canada. Q 400 - 09/10.