Design of Baseplate and Anchor Bolts at Support

Reactions taken from Supports

P= 25 KN
M= 1.9 KN-m

150
P
M

150
Area of Baseplate = 22500 mm²

Thickness of Baseplate = 16 mm

f'c of concrete pedestal = 21 MPa


Fy = 248 MPa

Check for Bearing @ Pedestal

P ± Mc I = 42187500 mm4
ƒ=
A I

ƒ= -1.111 3.38
ƒ max= 2.27 MPa
ƒ min= -4.49 MPa

ƒ1 = (2.22) MPa
ƒ2 = 6.76 MPa < 0.35f'c 7.35 mpA

Check Required no. of Bolts


(2.22) C

Tmax = 12.50 KN

T 6.76

using ø 20 A-307 Anchor bolts


Abolt = 314.16 mm²

FT = 137.90 MPa

TØ20 = 43.32 KN

12.50
n=
43.32

n= 0.29

say 2 bolts

Check Embedment of Achorage Check thickness of Plate

  Allowable Load Stress of Concrete due to pullout

T / bolt = 6.25 KN
10.14 f'c
 D

 2.32 MPa

 P
p D Le

Le = 42.81 mm
L = 87.81 mm

say L = 200 mm M= 0.23 KN-m

fb = 0.66 Fy
fb = 163.68 MPa

t= 6M
fb b
t= 7.01 mm

say t = 16 mm
area = 22500
I= 42187500