You are on page 1of 1

201

10
200 2235
CLEAR
NEW PARAPET
GIRL'S WASHROOM
W1 EX PARAPET
UPPER 225

NEW PARAPET
EX LANDING

1780
EX 10
201

EX
10

100
6 TYP
9
4

250
9
EX HR EX 2% SLOPE DN
W3 1

550
NEW BB
A-4
2

1245+/-
200

NEW

INSIDE
7 5

1830
8 UPPER
MODIFIED LANDING ELEVATOR LANDING
200 12
100
16 EX ROOF

W3

4 2% SLOPE DN

14 RISERS DN
195 +/- 1070 670 +/-

NEW PARAPET
W3
DOOR OPENING
1930 610

16 OPEN

CLEAR
1750
ELEVATOR SHAFT
AA
001 NEW PARAPET
A-4
CC
1 A-4 1

EX PARAPET
W3
10
1

4
HR
3
2540 TYP
PARTIAL ROOF PLAN
14 RISERS DN

CLEAR

11 11 11 11
EX RADIATOR

13
1525

NEW

PROJECT NORTH
NEW LANDING
202
W E

ELEVATOR LANDING
EX 100 14
S
PROJECT TITLE

DD NEW
15 Central School
A-5
Elevator
PARTIAL SECOND FLOOR PLAN NEW
811 Stanley Street
Nelson, BC
NOTES
PROJECT STATUS
1. NEW REINF. CONC. BLOCK WALLS. REFER TO STRUCTURAL .

2. CUT NEW ENTRY THROUGH EX WALL. (TO BE SITE DETERMINED .) ISSUED FOR TENDER: May. 01, 2018
3. NEW BRICK VENEER W/ AIR SPACE & RIGID INSULATION. REFER TO DETAILS, PAGE A-5.
4. CONTINUE CONC. BLOCK TO ADJOIN EX. REFER TO STRUCTURAL . SHEET TITLE

5. NEW 1600 WIDE x 1800 TALL GLASS BLOCK WINDOW.

6. CONSTRUCTION START DIMENSION TAKEN FROM EXISTING EXTERIOR BRICK FACE.


CONFIRM ALL DIMENSIONS ON SITE.
Partial Second Floor &
7. EXTEND MODIFIED ST. LANDING. REFER TO STRUCTURAL .
ELEVATOR SHAFT
Roof Plans
001
8. DEMOLISH EX STAIR & RAMP INDICATED BY DASH LINES. REFER TO SECTION C-C,
DRAWING A-5 & STRUCTURAL DRAWINGS .
9. REMOVE EX WINDOW & INFILL WITH WALL PATCH. MATCH ADJACENT SURFACES
USING SAME MATERIALS .
DRAWN BY MS FILE 1646 A-3
10. REMOVE PORTION OF EX PARAPET WALL INDICATED BY DASHED LINES
AND REBUILD AS PER DETAILS, DRAWING A-5. SCALE 1:25 • DATE PLOTTED •
11. SALVAGE & MODIFY EX ST. HANDRAIL TO SUIT NEW CONDITIONS . PAINT.
PROJECT NUMBER 1646 May. 01, 2018
12. NEW TORCH-DOWN MEMBRANE .

13. EX RADIATOR TO BE REMOVED. REFER TO MECHANICAL . SHEET NO.


14. NEW 610 x 1220 ACOUSTIC TILE T-BAR GRID SUSPENDED CEILING.
(REFER TO ELECTRICAL.)

15. 305 x 1220 LUMINAIRE . (REFER TO ELECTRICAL .) REFLECTED CEILING PLAN


16. EXPOSED WALL CAVITY REQUIRED FOR ELEVATOR INSTALLATION BY MANUFACTURER .
(TYPICAL ELEVATOR LANDINGS FOR
REFER TO SHOP DRAWINGS. GENERAL CONTRACTOR TO FINISH ALL REINF. CONC. WALL,
FLOOR & CEILING PENETRATIONS ADJOINING ROUGH OPENING ONCE ELEVATOR INSTALLATION
IS COMPLETED. CONTROL BOX LOCATION ADJACENT TO ELEVATOR DOOR COORDINATED
BY ELEVATOR MANUFACTURER .
MAIN & UPPER FLOOR) A-3

Copyright reserved. This drawing, as an instrument of service, is the property of FAIRBANK ARCHITECTS LTD. and may not be reproduced without their permission and unless the reproduction carries their name. All designs and other information shown on this drawing are for use on the specified project only and shall not be used without the written permission of FAIRBANK ARCHITECTS LTD.

You might also like