You are on page 1of 4

PREDIMENSIONAMIENTO DE COLUMNAS

El sistema constructivo es aporticado


ANTEPENULTIMO NIVEL (Primer Nivel)
NOMENCLATURA At NUMERO DE Ata Ag SECCION PROPUESTA
TIPO K
COLUMNA (m²) NIVELES (m²) (cm²) (cm²)

A1 C4 7.590 2 15.180 0.00280 425.04 21 x 21


A3 C2 12.670 2 25.340 0.00200 506.80 23 x 23
A5 C2 10.360 2 20.720 0.00200 414.40 20 x 20
A7 C2 7.910 2 15.820 0.00200 316.40 18 x 18
B1 C4 7.520 2 15.040 0.00280 421.12 21 x 21
B3 C1 18.500 2 37.000 0.00110 407.00 20 x 20
B5 C1 15.350 2 30.700 0.00110 337.70 18 x 18
B7 C2 12.060 2 24.120 0.00200 482.40 22 x 22
C4 C1 12.580 2 25.160 0.00110 276.76 17 x 17
C7 C2 9.530 2 19.060 0.00200 381.20 20 x 20
D1 C3 16.000 2 32.000 0.00160 512.00 23 x 23
D4 C1 11.060 2 22.120 0.00110 243.32 16 x 16
D7 C2 8.050 2 16.100 0.00200 322.00 18 x 18
E7 C2 4.000 2 8.000 0.00200 160.00 13 x 13
F6 C2 8.500 2 17.000 0.00200 340.00 18 x 18
G1 C2 7.540 2 15.080 0.00200 301.60 17 x 17
G1 C2 14.220 2 28.440 0.00200 568.80 24 x 24
G4 C2 12.400 2 24.800 0.00200 496.00 22 x 22

Luz mas frecuente del portico principal = 6.40 1° NIVEL


MENSIONAMIENTO DE COLUMNAS

SECCION
RECOMENDADA (cm²)

25 x 25
25 x 25
25 x 25
25 x 25
25 x 25
25 x 25
25 x 25
25 x 25
25 x 25
25 x 25
25 x 25
25 x 25
25 x 25
25 x 25
25 x 25
25 x 25
25 x 25
25 x 25
PREDIMENSIONAMIENTO DE VIGAS

PRIMER NIVEL
VIGAS PRINCIPALES
TRAMO DE LUZ LIBRE SOBRECARGA PERALTE PERALTE ANCHO ANCHO DE ANCHO VIGA
ALFA
VIGA (m) (kg/m²) (m) REDONDEADO TRIBUTARIO VIGA REDONDEADO

A1 - B1 6.05 400 11.4 0.53 0.60 3.90 0.2 0.30


A2 - C2 6.05 400 11.4 0.53 0.60 3.90 0.2 0.30
A3 - C3 6.05 400 11.4 0.53 0.60 3.90 0.2 0.30
A4 - C4 6.05 400 11.4 0.53 0.60 3.90 0.2 0.30
A5 - C5 4.90 400 11.4 0.43 0.60 3.90 0.2 0.30
A6 - C6 4.90 400 11.4 0.43 0.60 3.90 0.2 0.30
A7 - C7 4.90 400 11.4 0.43 0.60 3.90 0.2 0.30

SEGUNDO NIVEL
VIGAS PRINCIPALES
TRAMO DE LUZ LIBRE SOBRECARGA PERALTE PERALTE ANCHO ANCHO DE ANCHO VIGA
ALFA
VIGA (m) (kg/m²) (m) REDONDEADO TRIBUTARIO VIGA REDONDEADO

A1 - C1 6.40 150 11.4 0.56 0.60 3.90 0.2 0.30


A2 - C2 6.40 150 11.4 0.56 0.60 3.90 0.2 0.30
A3 - C3 6.40 150 11.4 0.56 0.60 3.90 0.2 0.30
A4 - C4 6.40 150 11.4 0.56 0.60 3.90 0.2 0.30
A5 - C5 6.40 150 11.4 0.56 0.60 3.90 0.2 0.30
A6 - C6 6.40 150 11.4 0.56 0.60 3.90 0.2 0.30
A7 - C7 6.40 150 11.4 0.56 0.60 3.90 0.2 0.30

VIGAS SECUNDARIAS
TRAMO DE LUZ LIBRE PERALTE PERALTE ANCHO VIGA ANCHO VIGA
VIGA (m) (m) REDONDEADO (m) (m) REDONDEADO

A1 - A2 4.00 0.29 0.3 0.15 0.25


A2 - A3 4.00 0.29 0.3 0.15 0.25
A3 - A4 4.00 0.29 0.3 0.15 0.25
A4 - A5 4.00 0.29 0.3 0.15 0.25
A5 - A6 4.00 0.29 0.3 0.15 0.25
A6 - A7 4.00 0.29 0.3 0.15 0.25
PREDIMENSIONAMIENTO DE LOSA MACIZA

La losa para la primera planta sera maciza reforzada en una direccion

Lado mayor del paño 6.10 ml


Lado menor del paño 4.00 ml
Perimetro del paño 20.20 ml
Espesor de la losa maciza 0.112 mts
Espesor redondeado 0.10 mts

PREDIMENSIONAMIENTO DE LOSA ALIGERADA

El segundo nivel y demas niveles tendran una losa aligerada

Longitud de luz en el sentido del techado 4.00 ml


Espesor de la losa 0.16 mts
Espesor de la losa aligerada 0.20 mts