he main function of an underground located in similar climatic regions can
ventilation system is to provide a be used as examples and benchmarks,
safe, comfortable working environ- such as uranium mines located in the
ment in all accessible areas of a mine. Russian and Canadian Arctic, although
This means that: each operation should be treated on
• Contaminants including explosive an individual basis.”
fumes (containing nitrous oxide and
carbon monoxide), airborne dust, and KEY COMPONENTS
naturally occurring gases such as Primary ventilation systems have three key
methane, carbon dioxide, hydrogen components: all underground workings,
sulphide and radon are diluted to safe including the main adit or decline, capital
levels by airflows of sufficient quantity development, main shaft, stopes and
and quality; production areas; specific ventilation
• Sufficient oxygen is supplied to workers workings such as ventilation shafts, raises important to have in the warehouse. In a
underground; and drives; and the ventilation equipment, metals mine this may mean continuing
• Air temperature, speed of movement including the main fan required to circulate operations; however, in a gassy situation
and humidity remain between the legal air through the primary circuit. In addition, such as a coal mine it may mean keeping
maximum and minimum levels, and at a ventilation controls such as walls, airlocks, explosive gases from building to
comfortable level as far as is practicable. stoppings, air crossings and regulators dangerous levels.”
Ventilation regulations and associated can be added to improve the function and Secondary ventilation is used in
“Ventilation legal levels for contaminants, temperature, control of the primary ventilation system. development headings and production
regulations air speed and oxygen vary from country to Primary ventilation fans are generally in areas at the end of drives. Fresh air is
country. These are mainly dependent on: continuous operation to keep a constant brought to the working area from the
and asso- which commodities have historically been flow of air moving underground. Coal primary ventilation system by an auxiliary
ciated legal mined; the general labour legislation; past mines are always ventilated by parallel fan, via vent ducting, and flows back in the
levels for accidents; the level of scientific knowledge primary vent circuits as methane can build drive. Secondary ventilation fans are
regarding pollutants and to what degree up in the air if too many workplaces are turned off during blasting in each heading
contaminants, this knowledge has been translated into ventilated by the same flow. Uranium to prevent damage to the vent bag, and
temperature, legislation; and the legislative, political mines need to have single-pass flow therefore need to be located in a safe
and social environment of the country. through ventilation systems to remove location, which is ventilated by the primary
air speed The circumstances in which it is radon gas as quickly as possible as system. Extra components such as ancillary
and oxygen comfortable for personnel to the daughter products of control systems for dust suppression,
vary from work are subjective, and radon, which are formed gas drainage, refrigeration and heating
vary strongly between within a short time, are systems can be added to ventilation
country to region and country. more dangerous than systems with specific requirements.
country” The main aims should radon itself. Mr Fuykschot comments: “Primary
be the prevention of Daniel Stinette, surface fans range from 200kW to 1MW,
fatigue, overheating, senior ventilation while auxiliary fans range from around
and under-cooling, engineer at Mine 25-200kW. Each fan type has a specific fan
which could Ventilation Services, curve, which describes the relationship
negatively affect says: “The type of between pressure rise and volume flow
health and safety. fans used varies, rate for a constant impeller speed (rpm).
Conditions should be depending on the Similarly, the relationship between
reasonably comfortable as system parameters, and can pressure loss and volume flow rate is
far as can practicably be include combinations of the most commonly used system
arranged. As the layout of a mine is vane-axial, centrifugal and mixed-flow characteristic. Ideally, the duty point is
constantly changing, the effectiveness of fans from 5-3,000kW, arranged in parallel close to the peak efficiency of the fan.”
the ventilation system will vary over time. or series on the surface or underground. To determine the size of key ventilation
Jurgen Fuykschot, senior mining Primary and booster fan arrangement system components, SRK recommends
engineer at SRK Consulting (UK), explains: varies, according to a variety of system modelling the system using specific
“Engineers designing a mine should parameters, and should be optimised programs such as Ventsim, VnetPC and
always be aware of the local mining through the use of modelling software.” VUMA to simulate the ventilation network
legislation and regulations with regard to Rob Pope, vice-president of Jet Air, and optimise the design. By combining
ventilation. Awareness of international explains: “Generally, if one larger fan can the mining schedule with the ventilation
At Sao Bento best practice standards and available meet the performance level required, design, capital expenditure can be planned.
mine in Brazil, equipment may lead to better or more two smaller fans will be chosen instead. Programs such as Ventsim and ClimSIM
Cogmacoustic efficient mine designs, especially when If one fan experiences a failure, at least can also run thermodynamic modelling to
installed a single specific mining regulations are non-existing 50% of the ventilation is operable until determine the size of heating or cooling
stage fan with or outdated and can possibly be changed. repairs are made. If a fan is a critical part installations, where required.
16 blades “Mines producing the same commodity of the operation, a spare fan or parts are To ensure all these components are in
time if their inhalation is not prevented. the most common being the planning of Two-fan mine
Mr Stinette explains: “Varying ore types egress routes and/or refuge locations in ventilation system,
and mining methods dictate the type of the event of an underground fire. exhausting out
ventilation system required. For example, Dariusz Holod, ventilation expert at of a vent raise
gassy coal mines would require significant Stantec Mining, says: “The most common
attention to the dilution and removal of emergency factored into mine design is
methane. Equally, coal mines, which are underground fire. Ventilation system
susceptible to spontaneous combustion, designs will include escape-ways, fire
would require a different approach. In doors or even the reversal of ventilation
metal mines, the difference in ventilation fans. There is mine fire-evaluation
systems for a small, narrow-vein and software that can be used specifically for
high-grade deposit and a large-scale and ventilation design at coal mines.”
highly mechanised operation can differ in Geographical location, surface climate,
both scope and size.” virgin rock temperature, thermal gradient
Mr Fuykschot says: “The final ventilation and depth of mine will determine the need
system should be designed to operate at for additional heating or cooling. Heating
the maximum expected capacity of the is generally undertaken on the intake air to
mine, with enough spare capacity to prevent ice forming in shafts and ensure
account for factors such as leakage, comfortable working conditions. However,
place, have the correct capacity, run blockage by machinery and expected gas heating may lead to lower geotechnical Jet Air fan
properly and are adequately maintained, inflows. The ventilation system capacity is stability of the surrounding rock at mounted in a
continuous monitoring systems can check ideally linked to the life-of-mine plan to operations located in permafrost. bulk head
that fan operation, gas content, air speed prevent under and excess design capacity.
and temperature are at the correct levels. Under-capacity can lead to unhealthy and Fan types
Dedicated ventilation personnel are a unsafe situations, and may cut or limit
legal requirement in most countries when production levels. Excess design capacity Axial: high-volume, low-pressure fans either directly driven
designing and maintaining ventilation after the maximum production capacity is by the motor shaft (motor inside the tube body) or remotely
systems for mines, and it is important that reached leads to unnecessary operational driven using belts (motor outside the tube body). Volume is
management adopts a good ethos costs such as power and maintenance.” adjusted by setting the pitch of the adjustable blades on the
towards staff safety. The type, size, work location and rotor and, in some cases, motor speed can be tailored to
mobility of mining machinery must also adjust volume and pressure.
SYSTEM DESIGN be considered during the design phase. Centrifugal: low-volume, high-pressure fans consisting of a
Ideally, ventilation engineers would be This is directly related to production multi-bladed, squirrel-cage wheel in which the leading edge
involved from the early mine-design stage levels, and all machinery, particularly of the fan blades curve towards the direction of rotation.
to prevent the need for costly correction diesel-driven equipment, requires sufficient These have low space requirements, low tip speeds and are
later on, which could affect production if ventilation to work at optimum levels. If relatively quiet.
the capacity of the ventilation system is insufficient ventilation is provided, areas of
under-designed. the mine could potentially be shut down.
When designing mines and suitable The mining method itself – whether it is
ventilation systems it is important to take mechanised or uses blasting – the amount
into account the commodity or product of explosive used per tonne, and the
being mined. Requirements will vary widely amount of broken material and dust
as some mines will experience higher generated also need to be considered.
levels of potentially toxic or explosive With regard to mine layout, the
gases released during the mining process capital access method – ie decline,
or generate more dust than others. adits or shaft – need to be
Coal mining releases methane, which designed with production and
can build up to potentially explosive levels ventilation requirements in mind
if it is not properly regulated. Coal mines as changing the size of a shaft
are often extremely dusty due to the nature after development is very costly
of extraction. This dust is susceptible to and will halt production. Vertical
spontaneous combustion and can cause and lateral expansion will also
numerous respiratory conditions such as influence the number and size of
black lung during prolonged exposure. extra ventilation openings, such
Uranium mines produce high levels of as raises and drives, required.
radon, which builds up in confined spaces, Mines with decline access are
exposing workers to background radiation generally located closer to the
and it can cause diseases such as radon surface than those accessible via
poisoning or lung cancer. shafts. Increased (relatively cheaper)
Operations that extract sulphide-type access to the surface environment will
ores often produce hydrogen sulphide in have a big impact on ventilation system
large quantities, which can cause oxygen design and infrastructure requirements.
deprivation and sulphide dust explosions. Near-surface mines typically require less
Fibrous materials such as asbestos, the (or zero) cooling than deeper ones.
particles of which are released into the air Various emergency scenarios will need
during mining, can cause fibrosis over to be factored into the ventilation design,
Fan
The fan duty for fan power and size calculation.”
point and its Mr Holod adds: “In most cases, newly
curve illustrate designed cooling systems are located on
fan performance Fan curve the surface. It is also common to design
when confronted Fan duty point ventilation and cooling systems as part of
Mine resistance
with the total a mine expansion when new ventilation
mine resistance shafts or raises are added. Some existing
Pressure (Pa)