Professional Documents
Culture Documents
Total 7530.2141
3rd Floor
Area Thickness/Length W. Density Pressure Weight
Slab 624.05 0.15 23.6 2209.137
Topping 624.05 0.05 22.6 705.1765
Beam 0.3 346 23.6 2449.68
Column 14.6 3 23.6 1033.68
Interior Wall 388.8 1 388.8
Exterior Wall 119.58 3.45 412.551
Glass Wall 68.8 0.02 25.1 34.5376
Stairs 4 1.5 23.6 141.6
Total 7375.1621
4th Floor
Area Thickness/Length W. Density Pressure Weight
Slab 624.05 0.15 23.6 2209.137
Topping 624.05 0.05 22.6 705.1765
Beam 0.3 346 23.6 2449.68
Column 14.6 3 23.6 1033.68
Interior Wall 388.8 1 388.8
Exterior Wall 119.58 3.45 412.551
Glass Wall 68.8 0.02 25.1 34.5376
Stairs 4 1.5 23.6 141.6
Total 7375.1621
Roof Top
Area Thickness/Length W. Density Pressure Weight
Slab 624.05 0.15 23.6 2209.137
Topping (Roof) 624.05 0.05 22.6 705.1765
Beam 0.3 346 23.6 2449.68
Column 14.6 1.5 23.6 516.84
Interior Wall 194.4 1 194.4
Exterior Wall 59.79 3.45 206.2755
Glass Wall 34.4 0.02 25.1 17.2688
Stairs 4 1.5 23.6 141.6
Total 6440.3778
Total W 28720.9161
Soil Profile
Nv Z Cv I Ct
Type
1 D 0.4 0.64 1 0.08
V (Base
hn T R W
Shear)
10.95 0.48156 8 28721 4771.31070991
V - Ft Fx
4610.47 1521
4610.47 1503.17
4610.47 1026
4610.47 560.315
- -