PRODUCT DATA

Page 1
Section KLAUS Multiparking GmbH
Dimensions Hermann-Krum-Straße 2
Car data D-88319 Aitrach
Fon +49 (0 ) 75 65 5 08-0
Page 2 Fax +49 (0 ) 75 65 5 08-88

2000 kg 1 / 2600 kg
Width dim. info@multiparking.com
www.multiparking.com
without door 2

Garage without door (basement garage) Dimensions


Page 3
Width dim. 160 45 Free space All space requirements are minimum
with door finished dimensions.
Function Tolerances for space requirements + 03 . 3
Free space
Dimensions in cm.
EB (single platform) = 2 vehicles
50

Page 4

80
Approach DB (double platform) = 4 vehicles
Load plan Suitable for
6
Cutting through

Standard passenger cars:


Limousine, station wagon, SUV, van

Headroom according 12
Page 5
according to clearance and maximal

to local regulations
surface load.
Installation
Electrical

8
Standard Special 3
installation

Delimitation
width 190 cm 4 190 cm 4
weight max. 2000 kg max. 2600 kg
Page 6
100

Technical
data wheel load max. 500 kg max. 650 kg

Clearance profile
Page 7 160 30
To be perfor-
med by the

45

55
customer
Grounding

see table
7
Description
Water drainage 9 10

1-2% 1-2%
15° 13°

100 125
500 (520)

520 for vehicle up to 5.00 m = 16’4’’ long 50


(540 for vehicle up to 5.20 m 17’ long) 11
2072i-165 2072i-170 2072i-180 1 2072i-185 2072i-195

5
5
5

380 (350)
5

360 (340)
350 (335)
330 (325)
320
165

170
170

180
175

185
185

190
195

200
car height car height car height car height car height
height upper lower height upper lower height upper lower height upper lower height upper lower
320 150 150 330 155 155 350 165 165 360 170 170 380 180 180
(325) 150 155 (335) 150 165 (340) 150 170 (350) 150 180
2072i-205 2072i-215 2072i-220 2072i-230
5
5

5
5

420 (370)

430 (375)

450 (385)
400 (360)
205

210
215

220
220

225
230

235

car height car height car height car height


height upper lower height upper lower height upper lower height upper lower
MultiBase 2072i | Code number 587.29.630 | Version 11.2015

400 190 190 420 200 200 430 205 205 450 215 215
(360) 150 190 (370) 150 200 (375) 150 205 (385) 150 215

1 Standard type 8 In compliance with DIN EN 14010, 10 cm wide yellow-black


2 Special system: maximum load for extra charge markings compliant to ISO 3864 must be applied by the
(maximum load for EB up to 3000 kg per place for extra charge). customer to the edge of the pit in the entry area to mark the
danger zone (see „load plan“ page 4).
3 To follow the minimum finished dimensions, make sure
to consider the tolerances according to VOB, part C 9 Slope with drainage channel and sump.
(DIN 18330 and 18331) and the DIN 18202. 10 At the transition section between pit floor and walls no hollow
4 Car width for platform width 230 cm. If wider platforms mouldings/coves are possible. If hollow mouldings/coves are
are used it is also possible to park wider cars. required, the systems must be designed smaller or the pits
accordingly wider.
5 If a higher ceiling height is available higher cars can
be parked. 11 For convenient use of your parking space and due to the fact
that the cars keep becoming longer we recommend
For dividing walls: cutting through 10 x 10 cm. a pit length of 540 cm.
6
Potential equalization from foundation grounding connection Must be at least as high as the greatest car height + 5 cm.
7
to system (provided by the customer).
12
MultiBase 2072i | Code number 587.29.360 | Version 11.2015 Page 2 of 7
Page 1
Width dimensions for garage without door (basement garage)
Section
Dimensions Dividing walls
Car data
Single Platform (EB) Double Platform (DB) Single and Double Platform (EB + DB) – Example
Page 2
Width dim.
without door
EB DB EB DB

Page 3
Width dim. B1 B1 B1 Carriageway in
with door accordance with
Function usable platform width B1 usable platform width B1 usable platform width B1 local regulations
230 260 460 490 230 + 460 750
240 270 470 500 240 + 470 770
Page 4 250 280 480 510 250 + 480 790
Approach 260 290 490 520 250 + 500 810
Load plan 270 300 500 530 270 + 500 830
510 540 270 + 510 840
520 550 270 + 520 850
530 560 270 + 530 860
Page 5 540 570 270 + 540 870
Installation
Electrical
installation
Columns in pit
Single Platform (EB) Double Platform (DB) Single and Double Platform (EB + DB) – Example
Page 6
Technical
data
max.

max.

max.
EB EB DB DB EB DB EB DB
30

30

30
Page 7
max.

max.

max.
140

140

140
To be perfor-
med by the B2 B3 min. 20 B2 B3 min. 20 B2 B3 min. 20
customer
Carriageway in
accordance with
Description

usable platform width B2 B3 usable platform width B2 B3 usable platform width B2 B3 local regulations
230 255 245 460 485 475 230 + 460 745 735
240 265 255 470 495 485 240 + 470 765 755
250 275 265 480 505 495 250 + 480 785 775
260 285 275 490 515 505 250 + 500 805 795
270 295 285 500 525 515 270 + 500 825 815
510 535 525 270 + 510 835 825
520 545 535 270 + 520 845 835
530 555 545 270 + 530 855 845
540 565 555 270 + 540 865 855

Columns outside pit


Single Platform (EB) Double Platform (DB) Single and Double Platform (EB + DB) – Example

EB EB DB DB EB DB EB DB

B4 B5 min. 20 B4 B5 min. 20 B4 B5 min. 20


Carriageway in
accordance with
usable platform width B4 B5 usable platform width B4 B5 usable platform width B4 B5 local regulations
230 250 240 460 480 470 230 + 460 740 730
240 260 250 470 490 480 240 + 470 760 750
250 270 260 480 500 490 250 + 480 780 770
260 280 270 490 510 500 250 + 500 800 790
270 290 280 500 520 510 270 + 500 820 810
510 530 520 270 + 510 830 820
520 540 530 270 + 520 840 830
530 550 540 270 + 530 850 840
540 560 550 270 + 540 860 850

For parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm
for single platforms and 540 for double platforms. Problems may occur if smaller platform widths are used (depending on
car type, access and individual driving behaviour and capability).
For larger limousines and SUV wider driveways are necessary (in particular on the boxes on the sides due to the missing
manoeuvring radius).
MultiBase 2072i | Code number 587.29.360 | Version 11.2015 Page 3 of 7
Page 1
Garage with door Width dimensions for garage with door
Section
Dimensions
A1 13 Single platform (EB)
Free space for
roller shutter
Car data

Page 2
Width dim. EB EB EB
without door

80

A3 15
Page 3 B7 B7 B7 B8 B8
Width dim. B6 B6 B6
with door
Carriageway in accordance

Height
to door specifications
Function

Headroom according
with local regulations
A2 13
usable platform width door entrance width B6 B7 B8 u
Page 4 230 230 15 30
Approach 240 240 15 30
Load plan 250 250 15 30
260 260 15 30
270 270 15 30
Page 5 Double platform (DB)
Installation
Electrical
installation

DB DB DB
Page 6 Water drainage 14

15
Technical
data
1-2% 1-2%

A3
B7 B7 B7 B8 B8
A3 B6 B6 B6
50
13

Page 7 Carriageway in accordance


To be perfor- with local regulations
med by the
customer 13 Dimensions A1, A2 and A3 must be coordinated with the usable platform width door entrance width B6 B7 B8
Description door supplier (provided by the customer). 460 460 15 30
470 470 15 30
14 Slope with drainage channel and sump. 480 480 15 30
490 490 15 30
15 Seat-engaging surface (dimensions require coordination with 500 500 15 30
door supplier.) Allround door dimensions require coordination 510 510 15 30
between door supplier and local agency of KLAUS Multiparking. 520 520 15 30
530 530 15 30
540 540 15 30

For parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm
for single platforms and 540 for double platforms. Problems may occur if smaller platform widths are used (depending on
car type, access and individual driving behaviour and capability).
For larger limousines and SUV wider driveways are necessary (in particular on the boxes on the sides due to the missing
manoeuvring radius).

Function
System lifted System lowered
MultiBase 2072i | Code number 587.29.360 | Version 11.2015 Page 4 of 7
Page 1
Approach
Section
Dimensions
Car data

Page 2
Width dim.
without door

Page 3
Width dim. maximum maximum
with door descending ascending
Function slope 3 % slope 10 %

Page 4
Approach
The illustrated maximum approach angles must not be exceeded. Incorrect approach angles will cause serious
Load plan
maneouvring & positioning problems on the parking system for which the local agency of KLAUS Multiparking
accepts no responsibility.

Load plan
Page 5
Installation
Electrical
installation
F5 F6 F6 F5 F5 F6 F6 F5
F2 F2 F2 F2
Page 6
F3 F4 F4 F3 F3 F4 F4 F3
Technical
data
F6
F4

Page 7
H1

To be perfor-
med by the F5 F1 F1 F1 F1
customer
F3
Description
10

F2 F1 EB DB
Marking 17 Marking 17

290 180
7,5 7,5 7,5 7,5
520 (540) B1 16 B1
10

platform load F1 F2 F3 F4 F5 F6 18 Type H1


EB 2000 kg +28 +12 ±1 ±0,8 ±1,1 ±1,1 2072i-165 195
–1,5
+36 2072i-170 200
EB 2600 kg –1,9 +15 ±1,3 ±1 ±1,4 ±1,4
2072i-180 210
EB 3000 kg +42 +17 ±1,5 ±1,2 ±1,6 ±1,6
–2,1 2072i-185 215
DB 2000 kg +51 +20
–5,8 ±1,6 ±2,6 ±2 ±2 2072i-195 225
DB 2600 kg +67 +26 ±2,1 ±3,4 ±2,6 ±2,6 2072i-205 235
–7,4
2072i-215 245
2072i-220 250
2072i-230 260

Units are dowelled to the floor. Drilling depth: approx. 15 cm.


Floor and walls below the drive-in level are to be made of concrete (quality minimum C20/25)!
The dimensions for the points of support are rounded values. If the exact position is required, please contact
KLAUS Multiparking.

16 Dimension B1 see page 2


17 Marking compliant to ISO 3864 (colors used in this illustration are not ISO 3864 compliant)
18 All forces in kN
MultiBase 2072i | Code number 587.29.360 | Version 11.2015 Page 5 of 7
Page 1
Installation data – Free space for longitudinal and vertical ducts (e.g. ventilation)
Section
Dimensions
Car data B1+5 19 B1+2,5 B1+2,5 B1+5

Page 2
35 10 35 10 35 10 35 10
Width dim.
without door
Free space for vertical pipelines,
ventilation branch canals

30
Page 3
Width dim.
with door Approach level
Function

Page 4 20 20
Approach
Load plan

Free space for horizontal


Page 5
ducting

EB EB DB DB
Installation
Electrical
installation

Example for ventilation branch


Page 6 canal and/or vertical pipelines.
max.140

Technical
data

B2 19 B3 19 B2
Page 7 ≥20 ≥20
To be perfor-
med by the
Free space only applicable if vehicle is parked forwards = FRONT FIRST and driver’s door on the left side.
customer
Description

19 Dimensions B1, B2 and B3 see page 2

Electrical installation
Installation diagram Electrical data (to be performed by the customer)
1 No. Menge Description Position Frequency
1 1 Electricity meter in the supply
2 line
3 2 1 Main fuse:
3 x fuse 16 A (slow)) in the supply 1 per
or circuit breaker 3 x 16 A line 3,0 kW
4 (trigger characteristic K or C) unit
8 3 x fuse 20 A (slow)) in the supply 1 per
12 or circuit breaker 3 x 20 A line 5,2 kW
5 (trigger characteristic K or C) unit
13 Conduit EN 25 (M25) 3 1 Supply line 5 x 2,5 mm2 to main switch 1 per unit
(3 PH + N + PE) with marked wire
height: + 1.70 m and protective conductor
11
180

4 1 Lockable main switch defined at the 1 per unit


plan evaluation
Conduit EN 25 (M25) 5 1 Supply line 5 x 2,5 mm2 from main 1 per unit
9 10
120

height: + 1.10 m (3 PH + N + PE) with marked wire switch to unit


and protective conductor
0,00
6 every Foundation earth connector corner pit floor
10 m
7 1 Equipotential bonding in accordance 1 per
with DIN EN 60204 from foundation system
14 earth connector to the system

Electrical data (included in delivery of KLAUS Multiparking)


No. Description
8 Junction box unit
6 7
9 Wiring harness multiparking system
to the next
10 Connection cable (operating device)
system
11 Operating device
12 Control line 4 x 2,5 mm2 with marked wire and protective conductor
13 Hydraulic unit 3,0 kW/5,2 kW, three-phase current, 400 V / 50 Hz 20

14 Connection cable to the next system

20 Unit with 5,2 kW only for 2072i DB 2.6 to


MultiBase 2072i | Code number 587.29.360 | Version 11.2015 Page 6 of 7
Page 1
Technical data
Section
Dimensions Field of application CE Certification
By default, the system can only be used for a fixed number of The systems offered correspond to DIN EN 14010 and the
Car data

users. EC Machinery Directive 2006/42/EG.


Page 2 If different users use the system – only on the upper parking
Width dim. spaces – (e.g. short-time parkers in office buildings or hotels) Sound insulation
the Multiparking system needs to be adjusted. If required, According to DIN 4109 (Sound insulation in buildings), para. 4,
without door

would you please contact us. annotation 4, KLAUS Multiparkers are part of the building services
Units (garage systems).
Page 3
Width dim. Low-noise power units mounted to rubber-bonded-to metal Normal sound insulation:
with door mountings are installed. Nevertheless we recommend that
Function parking system’s garage be built separately from the dwelling. DIN 4109, para. 4, Sound insulation against noises from building
services.
Available documents
Table 4 in para. 4.1 contains the permissible sound level values
Page 4 – wall recess plans emitted from building services for personal living and working
Approach – maintenance offer/contract areas. According to line 2 the maximum sound level in personal
Load plan – declaration of conformity living andworking areas must not exceed 30 dB (A).
– test sheet on airborne and slid-borne sound Noises created by users are not subject to the requirements
Environmental conditions (see table 4 , DIN 4109).
Page 5
Environmental conditions for the area of multiparking systems: The following measures are to be taken to comply with this value:
Installation
Electrical Temperature range –10 to +40° C. Relative humidity 50% at a – Sound protection package according to offer/order
installation maximum outside temperature of +40° C. (KLAUS Multiparking GmbH)
If lifting or lowering times are specified, they refer to an – Minimum sound insulation of building R’w = 57 dB
environmental temperature of +10° C and with the system set (to be provided by customer)
Page 6
up directly next to the hydraulic unit. At lower temperatures or
Technical
data
with longer hydraulic lines, these times increase. Increased sound insulation (special agreement):
Building application documents Draft DIN 4109-10, Information on planning and execution,
proposals for increased sound insulation.
According to LBO and GaVo (garage regulations) the Multiparking
Page 7 systems are subject to approval. We will provide the required Agreement: Maximum sound level in personal living and working
To be perfor- building application documents. areas 25 dB (A). Noises created by users are not subject to the
med by the
requirements (see table 4, DIN 4109).
customer
Care
Description The following measures are to be taken to comply with this value:
To avoid damages resulting from corrosion, make sure to follow
our cleaning and care instructions and to provide good ventilation – Sound protection package according to offer/order
of your garage. (KLAUS Multiparking GmbH)
– Minimum sound insulation of building R’w = 62 dB
Corrosion protection (to be provided by customer)
See separate sheet regarding corrosion protection.
Note: User noises are noises created by individual users in our
Railings Multiparking systems. These can be noises from accessing the
If the permissible drop opening is exceeded, railings are to be platforms, slamming of vehicle doors, motor and brake noises.
mounted on the systems. If there are traffic routes next to or
behind the installations, railings compliant to DIN EN ISO 13857
must be installed by the customer. Railings must also be in place
during construction.
MultiBase 2072i | Code number 587.29.360 | Version 11.2015 Page 7 of 7
Page 1
To be performed by the customer
Section
Dimensions Safety fences Wall cuttings
Any constraints that may be necessary according to DIN EN ISO Any necessary wall cuttings according to page 1.
Car data

13857 in order to provide protection for the park pits for pathways
Electrical supply to the main switch / Foundation earth connector
Page 2 directly in front, next to or behind the unit. This is also valid during
Width dim. construction. Railings for the system are included in the series Suitable electrical supply to the main switch and the control wire
without door
delivery when necessary. line must be provided by the customer during installation. The
functionality can be monitored on site by our fitters together with
Numbering of parking spaces the electrician. If this cannot be done during installation for some
Page 3 Consecutive numbering of parking spaces. reason for which the customer is responsible, the customer must
Width dim. commission an electrician at their own expense and risk.
with door Building services In accordance with DIN EN 60204 (Safety of Machinery. Electrical
Any required lighting, ventilation, fire extinguishing and fire alarm
Function
Equipment), grounding of the steel structure is necessary, provided
systems as well as clarification and compliance with the relevant by the customer (distance between grounding max. 10 m).
Page 4 regulatory requirements. Operating device
Approach
Drainage Cable conduits and recesses for operating device (for double wing
Load plan
doors: please contact the local agency of KLAUS Multiparking).
For the front area of the pit we recommend a drainage channel,
which you connect to a floor drain system or sump (50 x 50 x 20 cm). Operating device exposed Operating device concealed
The drainage channel may be inclined to the side, however not the 120 above
Page 5
pit floor itself (longitudinal incline is available). For reasons of 110 above
Installation carriageway carriageway
Electrical
environmental protection we recommend to paint the pit floor, and level level
installation to provide oil and petrol separators in the connections to the public

15
sewage network.
= = = =

7
Page 6 Strip footings
Technical
If due to structural conditions strip footings must be effected, the

20
data
customer shall provide an accessible platform reaching to the top
of the said strip footings to enable and facilitate themounting work.
Conduit EN 25 (M25) 9 9

9
Page 7 Marking
To be perfor- According to DIN EN 14010, a warning that identifies this If the following are not included in the quotation, they will
med by the danger area must be placed in the entrance area that conforms also have to be provided / paid for by the customer:
customer
to ISO 3864. This must be done according to EN 92/58/EWG
Description
for systems with a pit (platforms within the pit) 10 cm from the – Mounting of contactor and terminal box to the wall valve,
edge of the pit. complete wiring of all elements in accordance with the circuit
diagram
– Costs for final technical approval by an authorized body
– Main switch
– Control line from main switch to hydraulic unit

Description Single platform (EB) and Double platform (DB)


General description Platforms consisting of:
Multiparking system providing independent parking spaces for – Platform base sections
2 cars (EB), 2 x 2 cars (DB), one on top of the other each. – Adjustable wheel stops
Dimensions are in accordance with the underlying dimensions of – Canted access plates
parking pit, height and width. – Side members
– Central side member [only DB]
The parking bays are accessed horizontally (installation deviation – Cross members [DB long and short cross members]
± 1% for correct drainage of platforms). – Safety railings – along the upper and lower platform (if required)
Due to the special lifting and bearing construction lifting of the doors – Screws, nuts, washers, distance tubes, etc.
is not restricted. Hydraulic system consisting of:
Vehicles are positioned on each parking space using wheel stops on – Hydraulic cylinder
the right side (adjust according to operating instructions). – Solenoid valves
Operation via operating device with hold-to-run-device using – Safety valves
master keys. – Hydraulic conduits
The operating elements are usually mounted either in front of the – Screwed joints
column or on the outside of the door frame. – High-pressure hoses
– Installation material
Operating instructions are attached to each operator's stand.
Electric system consisting of:
For garages with doors at the front of the parking system the special
dimensional requirements have to be taken into account. – Operating device (Emergency Stop, lock, 1 master key per
parking space)
Multiparking system consisting of: – Control unit with wiring harness and sensors
– 2 steel pillars (mounted on the floor) Hydraulic unit consisting of:
– 2 sliding platforms (mounted to the steel pillars with
sliding bearings) – Hydraulic power unit (low-noise, installed onto a console with a
– 2 platforms rubber-bonded-to-metal mounting)
– 1 electro-hydraulic synchronization control system (to ensure – Hydraulic oil reservoir
synchronous operation of the hydraulic cylinders while – Oil filling
lowering and lifting the platform) – Internal geared wheel pump
– 2 hydraulic cylinders – Pump holder
– 2 rigid supports (connect the platforms) – Clutch
– 2 chains and pocket wheels – 3-phase-AC-motor
– 2 automatic hydraulic safety valves (prevents accidental – Junction box unit with contactor, motor protection switch and
lowering of the platform while accessing the platform) control fuse
– Dowels, screws, connecting elements, bolts, etc. – Test manometer
– The platforms and parking spaces are end-to-end – Pressure relief valve
accessible for parking! – Hydraulic hoses (which reduce noise transmission onto the
hydraulic pipe)

We reserve the right to change this specification without further notice


KLAUS Multiparking reserves the right in the course of technical progress to use newer or other technologies, systems, processes,
procedures or standards in the fulfillment of their obligations other than those originally offered provided the customer derives no
disadvantage from their so doing.