You are on page 1of 1

4

4" 3"

1'-8"

1'-8"
SEE COLUMN SCHEDULE

5'-0"

5'-0"
2'-1"

20Ø @ 5" C/C (Bottom)


SECTION 4-4
20Ø @ 5" C/C (Bottom)

PLAN OF PILE CAP - PC4


CC 1:3:6

1'-8"

1'-8"
20mmØ @ 5"c/c
20mmØ @ 5"c/c

2'-2" 3'-10" 1'-8" 44"

4
16mmØ @ 5"c/c
Column size as per Column Schedule

12 mmØ Face bar@7" C/C

5
4" 3"
SEE WALL SCHEDULE

1'-8"

10'-2"
20mmØ @ 5"c/c
20mmØ @ 5"c/c

SECTION 5-5
16mmØ @ 5"c/c

20Ø @ 5" C/C (Bottom)

PLAN OF PILE CAP - PC5 20Ø @ 5" C/C (Bottom)


CC 1:3:6
Wall size as per Column Schedule .

1'-8"

2'-1" 5'-2" 2'-1" 44"


SEE WALL SCHEDULE

12mmØ Face bar@ 7" C/C

PROPOSED INFRASTRUCTURE BUILDER'S & MANAGEMENT DRAWING TITLES SHEET NO


"ROSE HAVEN PLACE" S.M. Kamal & Gon. L#04, H/F#04, RD#02, BL#C, Engr. Md. Waliul Islam Engr. Shekh Muhsen Uddin Ahmed Engr. Md. Bazlur Rahman
(G+9)TEN STORIED KAFRUL, MIRPUR-13, DHAKA. (AMIEB-19931) (AMIEB-19932) (MIEB- 33082)
S/12
OWNER

Structural Engineer. Structural Engineer. Structural Engineer. PILE CAP REBAR


PROJECT
CONSULTANT
DESIGN BY

RESIDENTIAL BLDG AT
CHECK BY

Cell:01515670988,01765588050 B.Sc Engg.(Civil), DUET B.Sc Engg.(Civil), DUET B.Sc Engg.(Civil), DUET
CHONDRIMA MODEL E-mail: ibminfo4u@gmail.com DETAILS-2 JB No: 018_18
DATE: APR-2019
TOWN, DHAKA. PC4 & PC5

You might also like