Professional Documents
Culture Documents
2
Area of footing required = P X 1.10 / SBC = 26.04 m
Area of footing L = 8.000 m
B = 3.500 m
CALCULATION OF CENTERIOD
8.000
1.525 4.950 1.525
1.375
1.375
2.475 2.475
Therefore, 491
Provide Y12 @ 125 mm c/c as main reinforcement. 491
Provide Y10 @ 150 mm c/c as distribution reinforcement. 491
BEAM DESIGN
Column R1-C' Column R1-G'
8.000
1.525 4.950 1.525
BMD
kN - m
612 612
802 1302
SFD
kN
1302 802
i. M = 612 kN - m b 750 mm
k = 1.84 D 900 mm
Pt = 0.47 d 815 mm
Ast = 2873 mm2
Bar dia = 25 mm Column width = 375 mm
No. of Bars 5.9 Stirups bar area = 79 mm2
Therefore, Provide 6Y 25
Provide NO EXTRA To get Beam Shear Reinforcement :
8000
1525 4950 1525
Provide 6Y 25
Provide 6Y 25 EXTRA
900
BEAM B1 = 750X900
Provide 6Y 25
Provide 6L Y10 @ 100 - 150 - 100 mm c/c. Provide 6Y 25 EXTRA
750
Provide NO EXTRA
225 Provide 6Y 25
900
675
3500