You are on page 1of 2

EuroPower Diesel Generator Sets

Powered by Mitsubishi

DESCRIPTION MITSUBISHI ENGINE

EuroPower generator sets offer a wide • World renowned brand in the line of
range of Prime & Standby Power ratings engine, produced from Mitsubishi
suitable for residential, commercial & • Heavy duty & durable 4-stroke water
industrial applications. cooled industrial engine
• Fuel injection pump.
All our equipment is guaranteed under • Multi-cylinder In-line or Vee
warranty against manufacture defects for arrangement
a period of 12 months or 1500 operating • Naturally aspirated or Turbocharged
hours from date of initial start-up, or 18 • With replaceable air, oil & fuel filters,
months from date of shipment, whichever starter motor, charging alternator
is earlier. 12/24V. DC electrical system

SCOPE OF SUPPLY ALTERNATOR


• Heavy duty steel channel base frame • Type: 4-pole, rotating field
• Vibration-damping supports between • Brushless, self exciting, self
engine/alternator & base frame regulating
• Set mounted tropicalised radiator • Voltage regulator: Solid state
with protection guards • Single bearing type
• Lead-acid starting batteries • Self ventilated, screen protected
• Industrial type silencer & stainless • Voltage regulation -1% at any fixed
steel flexible exhaust bellow load
• Set mounted auto-start control panel • Power factor: 0.8 @ 3P, 4W

EuroPower Technology Pte Ltd


71 Tech Park Crescent, Tuas Tech Park,
Singapore 638072 Tel: +65 6863 9091 Fax: +65 68636282
Email:info@europower.com.sg Website: www.europower.com.sg
EuroPower Diesel Generator Sets
Powered by Mitsubishi

Small Mitsubishi (50Hz)

Prime Standby Engine Alternator


Model Ramakrs
kw kva kw kva Mitsubishi Marathon
Single Phase,230V,
EPMIT7 4.9 6.1 5.4 6.8 L3E GM-5-4
1.0PF
Single Phase,230V,
EPMIT10 7.3 9.1 8 10.0 S3L2 GM-8-4
1.0PF
Single Phase,230V,
EPMIT15 10.9 13.6 12 15.0 S4L2 GM-12-4
1.0PF
EPMIT23 16.4 20.5 18 22.5 S4Q2 GM-16-4 Three Phase,400V,0.8PF
EPMIT33 24.1 30.1 26.5 33.1 S4S GM-24-4 Three Phase,400V,0.8PF
EPMIT44 31.8 39.8 35 43.8 S4S-DT GM-32-4 Three Phase,400V,0.8PF
EPMIT50 36.4 45.5 40 50.0 S4K MP-40-4 Three Phase,400V,0.8PF
EPMIT65 47.3 59.1 52 65.0 S4K-T MP-48-4 Three Phase,400V,0.8PF
EPMIT75 54.5 68.2 60 75.0 S6K MP-58-4 Three Phase,400V,0.8PF
EPMIT100 72.7 90.9 80 100.0 S6K-T MP-75-4 Three Phase,400V,0.8PF

Mitsubishi (50Hz, 3Ph, 400V, 0.8PF)

Prime Standby Engine Alternator


Model
kw kva kw kva Mitsubishi Stamford Marathon Engga
EPMIT663 480 600 530 663 S6R-PTA HCI544E MP-480-4A EG355L-500N
EPMIT750 540 675 600 750 S6R2-PTA HCI544F MX-560-4 EG355L-560N
EPMIT825 600 750 660 825 S6R2-PTAA LV634B MX-600-4 EG355L-600N
EPMIT850 620 775 680 850 S12A2-PTA LV634C MX-630-4 EG400S-640N
EPMIT1163 840 1050 930 1163 S12H-PTA LV634F MX-850-4 EG400L-900N
EG400L-
EPMIT1375 1000 1250 1100 1375 S12R-PTA LV634G MX-1030-4
1000N
EG400L-
EPMIT1500 1100 1375 1200 1500 S12R-PTA2 PI734B MX-1240-4
1200N
S12R- EG400L-
EPMIT1650 1200 1500 1320 1650 PI734C MX-1240-4
PTAA2 1200N
EG400L-
EPMIT1875 1360 1700 1500 1875 S16R-PTA PI734D MX-1350-4
1350N
EG500M-
EPMIT2063 1500 1875 1650 2063 S16R-PTA2 PI734E MX-1540-4
1600N
S16R- EG500L-
EPMIT2250 1630 2038 1800 2250 PI734F MX-1800-4
PTAA2 1800N

EuroPower
Ratings based on ISO3046, BS5514, DIN 6271, ±5% tolerance. Standard reference conditions: air inlet temperature 27°C. altitude 100m asl, fuel weight 0.85 kg/l, fuel consumption @ 75% prime load. Prime rating: Continuous running at variable load. No limit to
the annual hours of operations. 10% overload capability for 1 hour in any 12 hours. Standby rating: Emergency power at variable load in the event of utility power failure. No overload is permitted.
*Deration may be necessary at certain voltages.
Due to continually improved products, we reserve the right to make changes in model, technical specifications, colour, etc without prior notice.