Professional Documents
Culture Documents
MB-75JH/15
Dual-Output Amplifier
Installation Manual
SPLIT
JXP TDU
CONTROL MAN DRIVE UNIT
RTN
STATUS
OUT
3 MONITOR 4
-20 dB
SEE-* JXP RTN
RETURN IN FUSE
FUSE EQUALIZER STATUS
MONITOR OUTPUT
ASSEMBLED IN MEXICO OUTPUT PORT 3 & 4
AC
GROUND
SURGE
CAUTION
VOLTAGES IN EXCESS OF 150 VOLTS
MAY BE PRESENT UNDER COVER
DC VOLTAGE
ADJUST
ASSEMBLED IN MEXICO
Copyright © 1996 by General Instrument Corporation.
No part of this publication may be reproduced in any form or by any means or used to make any derivative work (such as translation,
transformation or adaptation) without written permission from General Instrument.
General Instrument reserves the right to revise this publication and to make changes in content from time to time without obligation on the part of
General Instrument to provide notification of such revision or change.
General Instrument provides this guide without warranty of any kind, either implied or expressed, including, but not limited, to the implied
warranties of merchantability and fitness for a particular purpose. General Instrument may make improvements or changes in the product(s)
described in this manual at any time.
Section 1 Introduction
Using This Manual ...................................................................................................... 1-1
Related Documentation .............................................................................................. 1-1
If You Need Help ......................................................................................................... 1-2
Calling for Repairs ...................................................................................................... 1-2
Section 2 Overview
Assemblies and Modules ........................................................................................... 2-2
Housing .................................................................................................................. 2-2
Model MPPS Power Pack ....................................................................................... 2-3
Forward Amplifier .................................................................................................... 2-5
Models MBD-SPLT and MBD-DC ............................................................................ 2-6
Return Signal Path .................................................................................................. 2-7
Forward Output Level Control ................................................................................. 2-7
Power Control Options ............................................................................................ 2-7
Amplifier Level Control ............................................................................................ 2-7
Optional Components and Accessories .................................................................... 2-8
Appendix A Specifications
Amplifier ....................................................................................................................... A-1
∗ .......................................................................................
Automatic Drive Unit, ADU/∗ A-2
Return Amplifier Kit, RA-Kit/40H ................................................................................. A-2
Return Amplifier Kit, RA-Kit/40L ................................................................................. A-2
Figures
Figure 2-1 MB-75*/15 mini-bridger block diagram ......................................................... 2-2
Figure 2-2 Block diagram of MPPS power pack ............................................................ 2-3
Figure 2-3 MPPS 60/90 power pack ............................................................................. 2-4
Figure 2-4 Location of the voltage range selector .......................................................... 2-5
Figure 2-5 Forward amplifier module ............................................................................ 2-6
Figure 2-6 Mini-Bridger amplifier module ...................................................................... 2-10
Figure 3-1 Tilt versus cable .......................................................................................... 3-3
Figure 3-2 Frequency versus cable slope ..................................................................... 3-5
Figure 3-3 Model MBD-DC output directional coupler ................................................... 3-6
Figure 3-4 Location of voltage selector ......................................................................... 3-7
Figure 3-5 ADU-* location ............................................................................................. 3-8
Figure 3-6 Typical test equipment and connections ...................................................... 3-10
Figure 3-7 TDU cable selector ...................................................................................... 3-11
Figure 3-8 MB-75* - MDR/10 board .............................................................................. 3-12
Figure 3-9 Effects of flatness controls on the MDR board ............................................. 3-13
Figure 3-10 Effects of flatness controls on the main board .............................................. 3-14
Figure 4-1 Pin connector .............................................................................................. 4-1
Figure 4-2 MB/15-HSG housing .................................................................................... 4-2
Tables
Table 2-1 Summary of optional components available with the MB-75*/15
mini-bridger ................................................................................................. 2-8
Table 3-1 Broadband cable simulator values ............................................................... 3-4
Table 3-2 Number of feet simulated ............................................................................ 3-5
Table 3-3 Gain reserves versus ambient temperature ................................................. 3-11
®
The General Instrument STARLINE Mini-Bridgers, models MB-75SH/15 and MB-75JH/15
dual amplifiers, are used in modern television distribution systems for amplification of
standard National Television System Committee (NTSC) television carriers as well as digital
channels. The MB-75SH/15 amplifies analog and digital signals carried in the bandpass
between 52 MHz and 750 MHz. The digital carriers have their relative amplitude set at the
headend and normally operate 10 dB below standard NTSC television channels. The
MB-75JH/15 amplifies conventional signals carried in the bandpass between 70 MHz and
750 MHz.
Section 1 Introduction. Provides a brief review of the function of the product in a distribution system.
Identifies the information contained in this manual, lists related documentation, and gives
the helpline telephone number.
Section 2 Overview. Provides a detailed description of the various components used in the amplifier.
It also provides instructions on proper installation of all options and subassemblies.
Section 3 Pre-installation Procedures. Describes methods of bench alignment, testing, and
configuration of the unit prior to installing it in the system.
Section 4 Field Installation. Describes the installation and field alignment procedures required to
place the unit into service.
Appendix A Specifications. Lists the applicable specifications for the amplifier and options.
This installation manual assumes that all channels are standard NTSC analog channels. Refer
to catalog specifications for further details pertaining to signal levels of digital channels above
550 MHz.
The asterisk (*) indicates that there are several versions or model numbers, and the
information applies to all models. When the information applies to a specific model, the full
model number is given.
Related Documentation
This installation manual is complete and you should not require any additional documentation
to install, test or operate the MB-75*/15 mini-bridgers.
GI Communications
c/o Fritz Company
1287 Fairway Drive
Nogales, AZ 85621
Attn: RSA #___________
The MB-75SH/15 and MB-75JH/15 mini-bridgers are dual output amplifiers having 15 amp ac
bypass capability. Both models are high gain, three-stage hybrid amplifiers designed to drive
both a limited cascade as well as a local distribution system. These amplifiers provide 110
channel capability. The MB-75SH/15 utilizes a forward bandpass of 52 to 750 MHz and a
return path of 5 to 40 MHz while models MB-75JH/15 uses a forward path of 70 to 750 MHz
and a return path of 5 to 55 MHz. The high gain feature — 35 dB operational — makes the
amplifiers suitable for drop-in replacement of trunk amplifiers that were originally spaced for
22 dB at 300 MHz. Use of the mini-bridgers eliminates the need for intermediate amplifiers
normally required to modify a “tree-and-branch” system into a “fiber-to-the-feeder”
architecture.
The attenuation of coaxial cable, as used in CATV systems, changes with variations in
temperature. The MB-75*/15 is equipped with a thermally-guided attenuation pad to ensure
constant gain of the hybrid ICs for all operating temperatures. An interstage Bode board,
which is an electrically controlled equalizer, receives its control input from the Automatic
Detection Unit (ADU) or Thermal Detection Unit (TDU) control boards, depending on which is
installed. The response of the Bode board is to compensate for coaxial cable attenuation caused
by temperature variations. If necessary, the Bode board can also be controlled manually by a
potentiometer, however, operating the MB-75*/15 permanently in the manual mode is not
recommended. The Bode equalizer, hybrid thermal compensation network, and the three-stage
design, permit the MB-75*/15 to maintain its distortion performance over wide temperature
ranges.
The basic amplifier is shipped in housing, model MB/15-HSG, and includes all necessary
components for a fully functional one-way amplifier, with the exception of the forward cable
equalizer, model EQ-750-*.
The block diagram in Figure 2-1 illustrates the functional interconnections of all stages in all
three amplifiers for MB-75*/15.
Figure 2-1
MB-75*/15 mini-bridger block diagram
Housing
The purpose of the housing is to protect the electronics from the elements and serve as a
radiator to dissipate the internally generated heat. While the amplifiers are shipped with the
model MB/15-HSG, they can also be installed in an existing MB-HSG housing using an
upgrade kit, model MB-15A.
Both housings can be strand mounted by using the included clamp and bolt assemblies, or
surface mounted by using suitable auxiliary brackets. The housings can also be pedestal or
surface mounted using the two 1/4 × 20 threaded holes provided in the lower housing.
Each housing is equipped with a combination woven-wire/silicone-rubber gasket between the
body and the cover for efficient ground continuity, RF shielding, and weather protection. The
input and output ports are protected by factory inserted plastic cap plugs which are discarded
when the cable connectors are installed.
Figure 2-2
Block diagram of MPPS power pack
Figure 2-3 shows the MPPS 60/90 power pack installed in the upper half of the MB/15 -HSG.
Figure 2-3
MPPS 60/90 power pack
In the model MB-75*/15 mini-bridgers, an internal voltage selector also permits operation over
an input voltage range of 38 to 60 Vac or 55 Vac to 90 Vac. Units are shipped with the selector
set for 38 to 60 Vac. An explanation of how to change the setting of this selector to meet system
requirements is provided in Section 3, Pre-installation Procedures. The selector is illustrated
in Figure 2-4 and can be accessed after removal of the power pack cover.
Figure 2-4
Location of the voltage range selector
Forward Amplifier
The forward amplifier’s electronics consist of two parallel three-stage paths. The first two
stages are common to both paths. The preamplifier stage has been selected for its low noise
factor, while the output stage provides the desired power at low distortion. At the input of the
amplifier, there is a facility to install a cable equalizer, and a socket for a model JXP-*A
attenuator. Both the attenuator and equalizer are customer installed options.
Intermediate amplifier stages are comprised of several circuits. One interstage circuit is the
Bode equalizer, which is a voltage controlled device that receives its input from the manual
gain control in the standard configuration form. It may also receive its input from the ADU-*
or TDU-* board when either of these options are employed. A flatness control circuit follows
the Bode board and allows optimization of the frequency response. This MB-75-MDR/10 board
serves two functions: the first is to control flatness, and the second is to provide equalization
that produces 10 dB of tilt for the output of the amplifier. This tilt is equivalent to
approximately 13.5 dB of cable at 750 MHz.
An on-board temperature controlled attenuator complements the Bode equalizer in controlling
amplifier flatness during temperature fluctuations.
Figure 2-5 illustrates the amplifier module with the cover partially cut away to show the
location of major components.
Figure 2-5
Forward amplifier module
n The ADU board, an optional plug-in module, monitors the amplitude of the selected pilot
frequency. The pilot frequency is an available NTSC television channel not scrambled by
the sync suppression method. Any changes in amplitude are fed back to the Bode equalizer
which makes appropriate corrections.
n Although less accurate than the ADU, the optional TDU board compensates for anticipated
signal level changes by sensing housing temperature and signaling needed changes to the
Bode equalizer. A selector on the TDU permits you to select 10 dB, 20 dB, or 30 dB of cable
at 750 MHz for which the TDU compensates.
In the event the ADU or TDU board fails, it is possible to select manual control of the Bode
board. The MAN potentiometer, shown in Figure 2-6, is located on the main circuit board.
Manual gain control in normal operation is not recommended because signals vary and,
therefore, distortion performances change.
Table 2-1
Summary of optional components available with the MB-75*/15 mini-bridger
Figure 2-6 is provided to show the location of common accessories and components.
Figure 2-6
Mini-Bridger amplifier module
Prior to installation, the MB-75*/15 must be equipped with several required accessory items.
The required items are to be determined from the data in the system layout documentation.
The addition of the required components and bench testing prior to installation is highly
recommended. The pre-installation procedure ensures proper alignment of all components and
significantly simplifies the field installation and balancing process.
To install selected options in the amplifier, unplug the power cord from the amplifier module by
applying a pulling force while depressing the locking tab of the connector. Loosen the screws
holding the cover in place and remove the cover. Component locations are now accessible.
Forward Equalizer
Cable equalizers are selected to compensate for cable attenuation versus frequency coupled
with their use in achieving proper output tilt. The amplifier comes equipped with a model
MB-75SH-MDR/10 interstage equalizer and flatness board which compensates for 13.5 dB of
cable at 750 MHz. Any additional cable loss beyond 13.5 dB must be compensated for by
selecting and installing the appropriate cable equalizer, model EQ-750-*. Equalizers are
available in 2 dB increments from 2 to 22 dB.
In instances when there is less than 13.5 dB of cable connected to the input of the amplifier, a
flat interstage board with flatness controls is an available option. Since the equalizer selection
process depends on specific circumstances, the following two examples illustrate some of the
options.
Example 1:
The amplifier is to be installed in a location that includes 20 dB of cable (at 750 MHz) between
its input and the preceding amplifier. Only cable loss should be considered, and any flat loss
due to splitters or other passive devices must be excluded. The internal equalizer, model
MB-75SH-MDR/10 , compensates for 13.5 dB of cable. This cable length must be subtracted
from the 20 dB of this example (20 − 13.5 = 6.5). The EQ-750-6 is the proper equalizer in this
case. With this equalizer installed, the amplifier reproduces the output tilt of the last upstream
amplifier.
Example 2:
The MB-75*/15 amplifier is to be used in a link following a fiber node. The fiber receiver’s
output is flat and connects to the input of the amplifier through 18 dB of cable plus passive
loss. Determine which is the proper equalizer to achieve the 10 dB output tilt from the
amplifier.
In this instance, the equalizer value can be calculated by using the following method:
where:
From established references and manufacturer’s catalogs, note that at an operating frequency
of 750 MHz, 18 dB of cable produces approximately 4.4 dB of loss at 54 MHz. This suggests
that the channel 2 signal input to the MB-75*/15 amplifier is 13.6 dB greater (18 − 4.4 = 13.6)
at channel 2 than at 750 MHz. Our example assumes that the high-end frequency level into
the amplifier is +12 dBmV.
Substituting this information into the above equation gives:
The slope of the required equalizer is 13.6 dB. This can be translated into an equivalent cable
value by either consulting Figure 3-1, or by using the appropriate multiplier. The multiplier in
this case is 1.37 dB (13.6 × 1.37 = 18.6). Therefore, the correct equalizer is the EQ-750-18, the
closest available equalizer value.
Multipliers to convert tilt to cable equivalent are:
The final choice of equalizer could vary somewhat when the amplifier is installed. This is due
to a number of independent variables including errors in cable attenuation, slope in passive
devices, and others.
In cases where the calculated equalizer value makes two choices possible, the lower value is to
be preferred.
Figure 3-1 graphically represents the relationship between dB of cable and dB of tilt.
Figure 3-1
Tilt versus cable
Table 3-1
Broadband cable simulator values
BCS-75- 1 2 3 4 5 6 7 8 9 10
50 MHz loss (typical) -1.0 -1.0 -1.0 -1.0 -1.0 -1.0 -1.0 -1.0 -1.0 -1.0
Figure 3-2
Frequency versus cable slope
The following table shows the number of feet of P III+ type cable that is simulated by the
BCS-75-*. For example, if you are using a BCS-75-3 cable simulator, you are simulating the
equivalent of 265 feet of P III+ 750 cable.
Table 3-2
Number of feet simulated
BCS-75- 1 2 3 4 5 6 7 8 9 10
P III+ Feet
500 61 122 183 244 305 366 427 488 549 610
625 74 147 221 294 368 441 515 588 662 735
750 88 177 265 354 442 531 619 708 796 885
875 101 202 303 404 505 606 707 808 909 1010
1000 106 213 319 426 532 638 745 851 957 1064
dB of cable @450 MHz 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 8.9 9.9
dB of cable @550 MHz 1.1 2.2 3.3 4.4 5.5 6.7 7.8 8.9 10.0 11.1
dB of cable @750 MHz 1.3 2.6 4.0 5.3 6.6 7.9 9.2 10.5 11.9 13.2
dB of cable @860 MHz 1.4 2.9 4.3 5.7 7.1 8.6 10.0 11.4 12.8 14.3
Output Passives
The MBD-JMP jumper furnished with the amplifier allows the user to select either port 3 or
port 4 as the second output port. However, if it is desired to provide signal output to both
ports, 3 and 4, then the proper output splitter must be installed. Installation of the MBD-SPLT
splitter provides equal output at ports 3 and 4. If unequal outputs are desired, use of the
MBD-DC, a 10 dB directional coupler, is required. It can be installed to provide a high level
output at either port 3 or 4 and a 10 dB lower level at the other port. The tap port, and
therefore the lower level, is indicated by the arrow on the MBD-DC circuit board and is shown
in Figure 3-3.
Figure 3-3
Model MBD-DC output directional coupler
Figure 3-4
Location of voltage selector
The MB-75*/15 is shipped with the jumper (J2) in the LO (60 V) position. To switch to the HI
(90 V) position, remove the jumper and insert it over the center and upper pins.
Figure 3-5
ADU-* location
When inserting the board, care should be exercised to assure proper mating of the pins on the
ADU-* board with the socket on the main circuit board. The pins are keyed with the socket to
permit entry in only one position. The ADU-* is enabled by placing the drive-control select
jumper in the DRIVE UNIT position. Automatic level control can be disabled at any time by
placing the drive-control select jumper in the MAN position.
The ADU-*, as supplied, is tuned to the channel which is to be used as the pilot frequency.
This channel must be present on the system continuously and can be modulated or
unmodulated. Retuning the ADU-* to an alternate frequency is not practical.
Two-Way Option
Two-way service can be implemented by installing the return amplifier kit, model RA-Kit/40*.
The return amplifier kit consists of a hybrid gain block, a selection of jumpers, and SEE-* cable
equalizers. These items are installed in the module in the locations shown in Figure 3-5.
Special care must be used when installing the hybrid gain block to ensure that all pins are
straight and aligned with the appropriate sockets on the circuit board. Heat sink compound
can be used between the hybrid flange and the housing to facilitate thermal conductivity. Use
of the heat sink compound is not mandatory, and is therefore not furnished with the kit.
Secure the hybrid gain block to the circuit board using the furnished screws.
Two return equalizers are supplied in the kit. They are models SEE-40-7 and SEE-55-4.4.
Input signal measurement can be made by installing an F/JXP adapter in the three-pin JXP
pad facility. The F/JXP adapter is also used for inserting a sweep signal into the return
amplifier path for test and alignment of the return system. It should be noted that the return
path is interrupted while the F/JXP is installed. The JXP pad or jumper should be replaced
after measurements or tests are completed. The status monitor output connector can be used
as an input test point rather than the JXP pad facility.
Output signal measurements can be made through the RTN OUT test point. This test point
signal level will be 20 dB below the actual level.
Figure 3-6
Typical test equipment and connections
Simulate the field location of the unit under test by applying the sweep signal through the
equivalent cable loss on the bench. For example, if the amplifier will be installed in a location
that includes 20 dB of cable between the previous amplifier and the unit under test, sweep
through a length of cable that exhibits the same 20 dB loss at 750 MHz.
Check that the proper equalizer and all other options have been installed. Usually the proper
equalizer can be calculated by subtracting the value of the interstage equalizer (13.5 dB) from
the cable loss preceding the amplifier. Referring to the example of the previous paragraph, the
proper equalizer should be 6 dB (20 − 13.5 = 6.5).
Figure 3-7
TDU cable selector
The single control on the TDU is a gain control and is marked TDU on the module cover. This
control is used to adjust the output level when using the TDU.
Apply power to the unit and check the output of the power supply. The voltage at the power
supply test point should be +24 Vdc ±0.2 V.
Connect a signal level meter to the output test point. Reduce the level of the highest frequency
channel by the gain reserves listed in Table 3-1 using the manual level control.
For example, if the measured carrier is at 550 MHz and the ambient temperature is 70°F,
reduce the level by 3 dB as shown in Table 3-3.
Table 3-3
Gain reserves versus ambient temperature
Flatness
The output of the amplifier at this point should be flat, i.e., the low end signal level (channel 2)
is equal to the high end frequency signal level. Peak-to-valley response variations can be
corrected by adjustment of the MDR board and trimmer capacitors C22 and C140 on the main
board. (Refer to Figure 3-5 on page 3-8 for the location of these two controls.) If the response
exhibits tilt, an improper equalizer has been installed and should be replaced. Less gain at the
low end frequencies indicates that the next lower value equalizer may be required, while loss of
gain at the high frequencies indicates that the next higher value of equalizer needs to be
installed.
Figure 3-8 shows the location of the controls, while Figures 3-9 and 3-10 show the approximate
effects on the frequency response of the amplifier. The changes in response, as they are shown,
were obtained by comparison against a normalized trace to emphasize the effect of the various
controls.
To test the flatness:
Figure 3-8
MB-75* - MDR/10 board
4 Check the gain at 750 MHz after optimum flatness is achieved and ensure that it’s greater
than or equal to the specified operational gain.
5 Adjust the slope control, R3, fully clockwise and ensure the maximum gain obtained meets
or exceeds the minimum full gain specification at 750 MHz. Set the cable program to
calculate the cable needed for a flat response. Check against the flatness specification.
6 Adjust the slope control, R3, for -8 dB below the minimum full gain level at 750 MHz. Set
the cable program to calculate the cable for a flat response. Check against the flatness
specification.
7 Adjust the slope control, R3, fully clockwise and then reduce the gain until the specified
operational gain at 750 MHz is obtained.
Figures 3-9 and 3-10 show the approximate effects on the frequency response of the amplifier.
Figure 3-9
Effects of flatness controls on the MDR board
Figure 3-10
Effects of flatness controls on the main board
Operational Gain
After the required flatness has been obtained, the operational gain of the unit can be measured.
Refer to Appendix A, Specifications, for proper operational gain values. The amplifier’s gain is
the measured gain plus the sum of all losses, including the power combiner and cable.
Operational gain must meet advertised specifications. If it does not, re-check the gain reserves
and re-check the loss associated with all external components, such as cable, test cables, and
the power combiner.
1 Double-check the tightness of cover screws and module hold-down bolts. Check the
condition of the RF and weather gasket. If needed, apply a light coat of silicone grease.
2 Fold the module handles and close the housing with care to avoid pinching the power cable
between the MPPS power pack and the module.
Mechanical Installation
The conventional method of installation is to suspend the unit by clamping it to the strand
installed for the support of the coax cable. Two factory equipped strand clamps are provided
for this purpose and can be positioned on either side of the housing to permit convenient curb
side entry.
An alternative method is to mount the housing on a pedestal. Mounting brackets are provided
as part of the pedestal. In the model MB/15-HSG housing, two threaded holes spaced
7.7 inches apart are provided on the rear of the unit for this purpose.
Housing Connections
Connections to the MB/15-HSG housing are made using standard housing entry port
connectors. Pin-type connectors with a nominal center conductor diameter of 0.067 inches are
required. The pin length of the center conductor is 1.50 inches minimum and 1.65 inches
maximum as measured from the seating plane of the connector. Figure 4-1 illustrates a typical
pin-type connector.
Figure 4-1
Pin connector
Powering-up
Apply power to the unit and allow a period of time for warm up. Both the ac and the B+
voltage should be checked at this time. When J2 is set at the LOW position, the ac input must
be above 38 volts. When J2 is set at the HIGH position, the ac input must be above 55 volts.
These voltages can be checked at the input connector center conductor with a true rms
voltmeter. The B+ voltage is required to be 24 Vdc ±0.2 volts. The housing should be closed
and torqued to protect the amplifier until final adjustments are made. Refer to Figure 4-2
below for the bolt tightening sequence and torque specifications.
Figure 4-2
MB/15-HSG housing
amplifier with 10 dB of output tilt can be checked through a 13.5 dB length of cable and the
resulting measurement will be flat. Figure 3-1 in Section 3, Pre-installation Procedures,
provides a comparison of cable loss versus slope for three different operating frequencies.
Open the housing and check the ac and dc voltages to assure that both are within the required
limits. The ac voltage should be above 38 Vac when J2 is set at the LOW position and be
between 55 and 90 Vac with J2 set at the HIGH position. The dc voltage should be 24 V ±0.2
volts.
revert to manual gain control. The “reserves” in the manual or automatic control modes
confirm that the amplifier is operating within its dynamic window of gain control.
To adjust the automatic gain control:
1 Connect the signal level meter to the output test point and tune the meter to the high end
active channel; for example, tune to 745.25 MHz for a 750 MHz system.
2 Turn the level control on the main board, denoted as ADU on the cover, to maximum (fully
clockwise). The measured level should be the operating level plus gain reserves for the
present temperature as shown in Table 3-1 in Section 3, Pre-installation Procedures. If the
level is greater, install a model JXP-*A input pad to achieve the required level to within 0.5
dB. For example, the operating level of the amplifier is +44 dBmV at 750 MHz. The
measured level is +49 dBmV, and the ambient temperature is 70° F. Table 3-1 shows that 4
dB of reserve is required at the present temperature. Using the calculation 49 – (44 + 4) =
1, the use of a 1 dB pad is indicated.
The pad selected should be installed at the input of the amplifier, and is located in the
upper left near the forward cable equalizer.
3 Adjust the ADU level control to achieve the desired output level (+44 dBmV in our
example). The ADU/* board controls the output of the amplifier for pilot levels from +39 to
+50 dBmV.
4 Measure the output tilt. The procedure for adjusting the tilt is exactly as described on the
previous page under the heading Thermal Gain Control.
1 Check all module cover screws as well as module retaining screws for proper tightness.
2 Close the housing with care to avoid pinching the cord between the power pack and the
amplifier module.
3 Tighten the housing closure bolts in the sequence and to the torque specifications
illustrated in Figure 4-2 for the model MB/15-HSG housing.
The specifications listed below apply to the MB-75*/15 amplifier as used without the return
amplifier or automatic control board options.
Amplifier
Passband
MB-75SH/15 52 to 750 MHz
MB-75JH/15 70 to 750 MHz
Minimum Full Gain at 750 MHz 39 dB
Operational Gain at 750 MHz 35 dB
Flatness ±0.75 dB
Gain Control Range 8 dB
Noise Figure
at 52 MHz 13 dB
at 750 MHz 11.5 dB
Return Loss 14 dB
Test Points
Input 20 dB ±1.0 dB
Output 20 dB ±1.0 dB
dc Supply 1310 mA at 24 Vdc
Power Consumption 44.0 W
ac Current
at 90 Vac 0.55 amps
at 75 Vac 0.63 amps
at 60 Vac 0.78 amps
at 53 Vac 0.89 amps
at 45 Vac 1.06 amps
at 38 Vac 1.30 amps
ac Bypass Current 15 amps maximum
Dimensions, MB/15-HSG 15.4” (L) x 5.5” (W) x 9.6” (H)
Operating Temperature –40° to +60° C
∗
Automatic Drive Unit, ADU/∗
Pilot Channel See current catalog
Pilot Channel Selectivity -11 dB, ±6 MHz from center frequency
Minimum MB-75*/15 Output at Pilot Frequency +36 dBmV
ALC Stiffness ±0.3 output change for ±3.0 dB input change
Power Requirement 24 Vdc, 70 mA