Professional Documents
Culture Documents
Configuration Directives:
XY Coordinate Calculations:
S1 S2 PIPE
Note: The thickness required was less than the Code Minimum, therefore
the Code Minimum value of 1.5000 mm. per UG-16 will be used.
SA-312 TP316L, Min Metal Temp without impact per UHA-51: -320 °F
Please note that Nozzle, Shell, Head, Flange, etc MAWPs are all considered
when determining the hydrotest pressure for those test types that are based
on the MAWP of the vessel.
Minimum 1.000
Minimum 4981.949
S1 S2 PIPE
Note:
The shipping total has been modified because some items have
been specified as being installed in the shop.
Weight Summary
Note:
The Corroded Weight and thickness are used in the Horizontal
Vessel Analysis (Ope Case) and Earthquake Load Calculations.
Surface
From To Area
m²
30 40 0.24827
Total 0.248 m²
Weights:
Fabricated - Bare W/O Removable Internals 8.9 kg.
Shop Test - Fabricated + Water ( Full ) 9.5 kg.
Shipping - Fab. + Rem. Intls.+ Shipping App. 8.9 kg.
Erected - Fab. + Rem. Intls.+ Insul. (etc) 8.9 kg.
Empty - Fab. + Intls. + Details + Wghts. 8.9 kg.
Operating - Empty + Operating Liquid (No CA) 8.9 kg.
Field Test - Empty Weight + Water (Full) 9.5 kg.