Drain Trap
for Air Conditioning Unit
[ International
Patent Pending ]
Caring about indoor air quality
The consideration
at the invisible place.
The development and manufacture of all our products conform to Japanese laws,
ordinances, and regulations.
Large
Air Conditioner
Movement of air
Sewage pipe
Floatball air backflow prevention valve is extremely effective, even when the sealing water has evaporated
When the C trap is installed in the drainage pipe of a small air conditioner…
Main installations : Small air conditioners such as fan coil units, room Prevents the backflow of air/ingress of insects into
units for building multiple air conditioners, and floor the air conditioner
installed package air conditioners (Internal static
pressure: 0~500pa)
Main installation location : Above the ceiling, inside the pipe shaft etc
Installation method : Incorporated into plumbing
Connection diameters : 25A, 30A, 40A, 50A
< International Patent Pending >
Floatballtype drain trap for
medium/large air conditioners
Features
There are basically 2 types of A Trap, the <Suction Type> and < Pressurized Type>, and you can select the type
required according to the type of air conditioner (negative pressure/positive pressure) used.
In particular, if you need to implement countermeasures against condensation, we recommend you select the <heat
insulation type>, which is the A trap unit that has been fitted with insulating material.
<Plan View>
Air conditioner base
Mortar
Concrete slab
Construction/Performance
Suction Type <S Type / SW Type> Performance Curve (For suction type <S Type>) *1)
Relationship between negative pressure from various water quantities and h
The two checking functions of the nonreturn valve (h: Height from bottom of main unit to air conditioner drain pan)
(special floatball) and float valve operate to prevent (mm)
odors and insects from entering the room, even if the 280
sealing water has evaporated. 260 (Water quantity)
240 10L/min
5L/min
220
h 200
Air Conditioner 180
Drain Pan
160
140
120
Trap
100
More than h
0 196 392 588 784 980 1176 1372 1568 1764 (Pa)
0 20 40 60 80 100 120 140 160 180 (mmAq)
Internal static pressure
70
Bottom of A trap
Nonreturn valve Float valve
(Special floatball)
*When installing the suction type <S Type>, find the h dimension from the performance curve that corresponds to the
internal static pressure of the air conditioner, and install it at a height greater than h.
*1) When finding the h dimension for the suction insulated type <SW>, add 10mm to the value obtained from the graph.
Air Conditioner
Pressurized Type Drain Pan
<P Type / PW Type>
Positive pressure in the air conditioner up to
an equivalent of 1,470pa (150mmAq) is
supported, preventing blowback.
More than 180mm
*2)
*2)
When starting operation of the air conditioner,
170
always fill the main unit to the flow outlet side section
top with water. Filling with water causes a water seal
to form, preventing air from flowing out.
Bottom of A trap
A Trap External Dimensions
Both the A Trap and C trap are designed to effectively prevent infestations of mice,
insects, and pathogens, bad odors, and the transmission of airborne infections via air
conditioner drainage pipes, and are constructed for easy maintenance.
F.A.Q.
A A
A A
.
H e a d Office: 3915 HonjoNishi, Kitaku, Osakashi, 5310073
TEL:(06) 63760810 FAX:(06) 63760819
To k y o Office: TEL:(03) 32060811 FAX:(03) 32066762
Nagoya Office: TEL:(0568) 516803 FAX:(0568) 516714
www.kondohfr p.co.jp
*Prices may be changed without prior notice.
*The specifications and external appearance of the product may be altered
This pamphlet was printed using vegetablebased soybean oil without prior notice for improvement purposes.
ink that is kind to the environment. May 2009