Data sheet
APP Pumps
APP pumps
APP 0.6-1.0 / APP 1.5-3.5 /
APP (W) 5.1-10.2 / APP 11-13 /
APP 0.6-1.0 / APP 1.5-3.5 / APP (W) 5.1-10.2 /
APP 16-22 / APP 21-43
APP 11-13 / APP 16-22 / APP 21-43
ro-solutions.com
ro-solutions.com.
Data sheet APP 0.6-43 / APP (W) 5.1-10.2 pumps
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. Application examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.1 APP 0.6-1.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.2 APP 1.5-3.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.3 APP (W) 5.1-10.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.4 APP 11-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.5 APP 16-22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.6 APP 21-30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.7 APP 38-43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5. Flow at different rpm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.1 APP 0.6-1.0 flow curves measured at 80 barg ( 1160 psig ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.2 APP 1.5-3.5 flow curves at 80 barg (1160 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.3 APP (W) 5.1-10.2 flow curves at 80 barg (1160 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.4 APP 11-13 flow curves at 60 barg (870 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.5 APP 16-22 flow curves at 60 barg (870 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.6 APP 16-22 flow curves at 60 barg (870 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.7 APP 21-30 flow curves at 60 barg (870 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.8 APP 21-38 flow curves at 60 barg (870 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.9 APP 43 flow curves 60 barg (870 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6 Flushing valve curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.1 APP 0.6–1.0 integrated flushing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.2 APP 1.5–3.5 integrated flushing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.3 APP 5.1-10.2 Flushing valve not available . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.4 APP 11-13 integrated flushing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.5 APP 16–22 integrated flushing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.6 APP 21–43 integrated flushing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7. Motor requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.1 Calculation factor for APP 0.6-1.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.2 Calculation factor for APP 1.5-3.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.3 Calculation factor for APP (W) 5.1-10.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.4 Calculation factor for APP 11-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.5 Calculation factor for APP 16-22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.6 Calculation factor for APP 21-43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
8. Temperature and corrosion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
8.1 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
9. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
9.1 Filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
9.2 RO system with direct supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
10. Dimensions and connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
10.1 APP 0.6-1.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
10.2 APP 1.5-3.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
10.3 APP (W) 5.1-10.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
10.4 APP 11-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
10.5 APP 16-22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
10.6 APP 21-43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
11. Dimensions with motor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
11.1 APP 0.6-3.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
11.2 APP (W) 5.1-10.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
11.3 APP 11.0-13.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
11.4 APP 16.0-22.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
11.5 APP 21.0-38.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
11.6 APP 43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
12. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
12.1 Accessories for APP (W) 5.1–10.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
12.2 Accessories for APP 11–13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
12.3 Accessories for APP 16–22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
12.4 Accessories for APP 21–43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
13. Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
1. Introduction The Danfoss range of APP high-pressure pumps tional to the number of input shaft revolutions
is designed according to EN 809 for use in RO (rpm). Unlike centrifugal pumps, they produce
applications with low viscosity and corrosive the same flow at a given speed no matter what
fluids such as: the discharge pressure.
1: Shaft sealing
2: Port flange
3: Bleeding plug
4: Retainer plate
5: Piston/shoe
6: Valve plate
7: Swash plate
8: Cylinder barrel
9: Springs
10: Port plate
11: Flushing valve
(not available on
APP 5.1-10.2)
12: Housing
13: Tail stock screws
14: Drain plug
3. Application examples Danfoss APP pumps are built into a broad range • obile systems for humanitarian and
M
of RO desalination plants around the world: military organizations
• Onboard systems for ships and yachts
• ontainerized solutions for hotels, resorts
C • Offshore platforms for the oil and gas
and residences on islands and in coastal industry
regions • Municipal and regional waterworks
Media 3) °C 2 - 50 2 - 50 2 - 50
temperature °F 36 - 122 36 - 122 36 - 122
1)
For lower and higher pressure, please contact Danfoss.
5)
A-weighted sound pressure level at 1 m from the pump unit
2)
For speeds above 3000 rpm the pump must be boosted at a pressure surfaces (reference box) acc. to EN ISO 20361 section 6.2. The noise
of 2-5 barg (29- 72.5 psig). measurements are performed acc. to EN ISO 3744:2010 on a motor-
3)
Dependent on the NaCI concentration - see chapter 8. pump unit at max. pressure and speed.
4)
Category 2, Zone 1 or Category 3, Zone 2.
6)
Max. area covered with recommended motor configuration
(excl. of space to service pump)
Media 3) °C 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50
temperature °F 36 - 122 36 - 122 36 - 122 36 - 122 36 - 122 36 - 122
Ambient °C 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50
temperature °F 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122
kg 8.6 8.6 8.6 8.6 8.6 8.6
Weight (dry)
lb 17 17 17 17 17 17
Sound
dB(A) 77 77 77 81 81 81
pressure level5)
1)
For lower and higher pressure, please contact Danfoss. 5)
A-weighted sound pressure level at 1 m from the pump unit
2)
For speeds above 3000 rpm the pump must be boosted at a pressure surfaces (reference box) acc. to EN ISO 20361 section 6.2. The noise
of 2-5 barg (29- 72.5 psig). measurements are performed acc. to EN ISO 3744:2010 on a motor-
3)
Dependent on the NaCI concentration - see chapter 8. pump unit at max. pressure and speed.
4)
Category 2, Zone 1 or Category 3, Zone 2. 6)
Max. area covered with recommended motor configuration
(excl. of space to service pump)
Media 3) °C 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50
temperature °F 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122
Ambient °C 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50
temperature °F 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122
kg 30 30 30 30 30
Weight (dry)
lb 66 66 66 66 66
Sound pressure
dB(A) 78 78 78 78 78
level5)
Media 2) °C 2 - 50 2 - 50 2 - 50 2 - 50
temperature °F 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122
Ambient °C 0 - 50 0 - 50 0 - 50 0 - 50
temperature °F 32 - 122 32 - 122 32 - 122 32 - 122
kg 78 78 78 78
Weight (dry)
lb 172 172 172 172
Sound pressure
dB(A) 85 85 85 85
level4)
1)
For lower and higher pressure, please contact Danfoss. 4)
A-weighted sound pressure level at 1 m from the pump unit
2)
Dependent on the NaCI concentration - see chapter 8. surfaces (reference box) acc. to EN ISO 20361 section 6.2. The noise
3)
Category 2, Zone 1 or Category 3, Zone 2. measurements are performed acc. to EN ISO 3744:2010 on a motor-
pump unit at max. pressure and speed.
5)
Max. area covered with recommended motor configuration
(excl. of space to service pump)
Pump size APP 16/1200 APP 16/1500 APP 17/1200 APP 17/1500 APP 19/1200 APP 19/1500 APP 22/1200 APP 22/1500
Code number APP 180B3254 180B3250 180B3255 180B3251 180B3256 180B3252 180B3257 180B3253
Code number APP ATEX 3)
180B3264 180B3260 180B3265 180B3261 180B3266 180B3262 180B3267 180B3263
Geometric cm³/rev. 234.6 188.3 253.3 197.5 272.3 219.7 310.6 253.3
displacement in³/rev. 14.32 11.49 15.46 12.05 16.62 13.41 18.95 15.46
Pressure
Max. outlet 1) barg 80 70 80 70 80 70 80 70
pressure
continuous psig 1160 1015 1160 1015 1160 1015 1160 1015
Inlet pressure barg 2-5 2-5 2-5 2-5 2-5 2-5 2-5 2-5
continuous psig 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5
Media 2) °C 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50
temperature °F 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122
Ambient °C 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50
temperature °F 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122
kg 78 78 78 78 78 78 78 78
Weight (dry)
lb 172 172 172 172 172 172 172 172
Sound pressure
dB(A) 84 84 84 84 84 84 84 84
level4)
Footprint with m² 0.54 0.58 0.59 0.59 0.76 0.76 0.80 0.80
IEc motor5) foot² 5.81 6.26 6.35 6.35 8.18 8.18 8.61 8.61
Typical motor size
Max. speed at
kW 37.0 37.0 45.0 55.0
max. pressure
1200 rpm at
HP 60.0 60.0 75.0 75.0
max. pressure
Torque at max. Nm 316 223 343 234 372 263 426 305
outlet pressure lbf-ft 233 165 253 173 275 194 314 225
1)
For lower and higher pressure, please contact Danfoss. 4)
A-weighted sound pressure level at 1 m from the pump unit
2)
Dependent on the NaCI concentration - see chapter 8. surfaces (reference box) acc. to EN ISO 20361 section 6.2. The noise
3)
Category 2, Zone 1 or Category 3, Zone 2. measurements are performed acc. to EN ISO 3744:2010 on a motor-
pump unit at max. pressure and speed.
5)
Max. area covered with recommended motor configuration
(excl. of space to service pump)
Pump size APP 21/1200 APP 21/1500 APP 24/1200 APP 24/1500 APP 26/1200 APP 26/1500 APP 30/1200 APP 30/1500
Code number APP 180B3051 180B3052 180B3054 180B3055 180B3056 180B3057 180B3060 180B3062
Code number APP ATEX 3)
180B3151 On request 180B3154 180B3155 On request On request On request On request
Geometric cm³/rev. 308.5 256 362 282 389 308.5 444 362
displacement in³/rev. 18.83 15.62 22.09 17.21 23.74 18.83 27.09 22.09
Pressure
Max. outlet 1) barg 80 80 80 80 80 80 80 80
pressure
continuous psig 1160 1160 1160 1160 1160 1160 1160 1160
Inlet pressure barg 2-5 2-5 2-5 2-5 2-5 2-5 2-5 2-5
continuous psig 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5
Media 2) °C 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50
temperature °F 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122
Ambient °C 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50
temperature °F 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122
kg 105 105 105 105 105 105 105 105
Weight (dry)
lb 231 231 231 231 231 231 231 231
Sound pressure
dB(A) 85 85 85 85 85 85 85 85
level4)
Footprint with m² 0.76 0.76 0.80 0.80 0.83 0.83 0.83 0.83
IEC motor5) foot² 8.18 8.18 8.61 8.61 8.93 8.93 8.93 8.93
Typical motor size
Max. speed at
kW 55.0 75.0 55.0 75.0 75.0 75.0 90.0 90.0
max. pressure
1200 rpm at
HP 75.0 100.0 100.0 125.0
max. pressure
Torque at max. Nm 418 355 490 388 527 426 608 498.68
outlet pressure lbf-ft 308 262 361 286 389 314 449 367.81
1)
For lower and higher pressure, please contact Danfoss. 4)
A-weighted sound pressure level at 1 m from the pump unit
2)
Dependent on the NaCI concentration - see chapter 8. surfaces (reference box) acc. to EN ISO 20361 section 6.2. The noise
3)
Category 2, Zone 1 or Category 3, Zone 2. measurements are performed acc. to EN ISO 3744:2010 on a motor-
pump unit at max. pressure and speed.
5)
Max. area covered with recommended motor configuration
(excl. of space to service pump)
Media 2) °C 2 - 50 2 - 50
temperature °F 35.6 - 122 35.6 - 122
1)
For lower and higher pressure, please contact Danfoss.
4)
A-weighted sound pressure level at 1 m from the pump unit
2)
Dependent on the NaCI concentration - see chapter 8. surfaces (reference box) acc. to EN ISO 20361 section 6.2. The noise
3)
Category 2, Zone 1 or Category 3, Zone 2. measurements are performed acc. to EN ISO 3744:2010 on a motor-
pump unit at max. pressure and speed.
5)
Max. area covered with recommended motor configuration
(excl. of space to service pump)
5. Flow at different rpm If the flow required and the rotation speed (rpm) of the Furthermore, these diagrams shows that the
pump is known, it is easy to select the pump fitting the flow can be changed by changing the rotation
application best by using the diagrams below. speed of the pump. The flow/rpm ratio is
constant, and the “required” flow can be
obtained by changing the rotation speed to a
corresponding value. Thus, the required rpm
can be determined as:
m1.4
3
/h
1.3
1.4 APP 1.0
1.2
1.3
1.1 APP 1.0
1.2
1.0 APP 0.8
1.1
0.9
1.0 APP 0.8
0.8 APP 0.6
0.9
0.7
0.8 APP 0.6
0.6
0.7
0.5
0.6
0.4
0.5
0.3
0.4
0.2
0.3
0.1
0.2 rpm
0
0.1
50 50
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
0
00 00
00 00
00 00
rpm
70
90
34 34
0
19 19
29 29
21 21
25 25
31 31
33 33
13 13
15 15
27 27
11 11
17 17
23 23
0
0
70
90
gpm
5.5
gpm APP 1.0
5.0
5.5 APP 1.0
4.5
5.0 APP 0.8
4.0
4.5
APP 0.8
3.5
4.0 APP 0.6
3.0
3.5 APP 0.6
2.5
3.0
2.0
2.5
1.5
2.0
1.0
1.5
0.5
1.0
0 rpm
0.5
00 00
0
00
00
00
00 00
00 00
00
00
00
00
00
00
00
rpm
70
90
11 11
17
23
29
13 13
15 15
19
21
25
27
31
33
34
0
0
00
00
00
00
00
00
00
00
00
00
70
90
17
23
29
19
21
25
27
31
33
34
m3/h
4.5
m3/h
4.0
4.5
APP 3.5 APP 3.0
3.5
4.0
3.0 APP 3.5 APP 3.0
3.5
APP 2.5
2.5
3.0 APP 2.2
APP 2.5 APP
2.0
2.5 APP 1.8
2.2
APP 1.5
1.5
2.0 APP 1.8
APP 1.5
1.0
1.5
0.5
1.0
0
0.5 rpm
00
0
00
00
00
00
00
00
00
00
00
00
00
50
70
90
11
17
23
29
13
15
19
21
25
27
31
33
34
0 rpm
0
00
0
00
00
00
00
00
00
00
00
00
00
00
50
70
90
11
17
23
29
13
15
19
21
25
27
31
33
34
gpm
18.0
gpm
16.0
18.0 APP 3.0
APP 3.5
14.0
16.0
APP 3.5 APP 3.0
12.0
14.0 APP 2.5 APP 2.2
10.0
12.0
APP 2.5 APP 1.8
2.2
8.0 APP 1.5
10.0
APP 1.8
6.0
8.0 APP 1.5
4.0
6.0
2.0
4.0
0 rpm
2.0
0
00
0
00
00
00
00
00
00
00
00
00
00
00
50
70
90
11
17
23
29
rpm
13
15
19
21
25
27
31
33
34
0
00
0
00
00
00
00
00
00
00
00
00
00
00
50
70
90
11
17
23
29
13
15
19
21
25
27
31
33
34
m3/h
11.0
m3/h APP (W)10.2
10.0
11.0
9.0 APP (W)10.2
10.0
APP (W) 8.2
8.0
9.0
7.0 APP (W) 7.2
APP (W) 8.2
8.0 APP (W) 6.5
6.0
7.0 APP (W) 7.2
5.0 APP (W) 5.1
6.5
6.0
4.0
5.0 APP (W) 5.1
3.0
4.0
2.0
3.0
1.0
2.0
0 rpm
1.0
00
00
0
00
00
00
00
00
00
00
70
80
90
11
14
17
10
12
13
15
16
18
0 rpm
00
00
0
00
00
00
00
00
00
00
70
80
90
11
14
17
10
12
13
15
16
18
gpm
gpm
45.0 APP (W) 10.2
40.0
45.0 APP (W) 10.2
APP (W) 8.2
35.0
40.0
APP
APP (W)
(W) 7.2
8.2
30.0
35.0
APP (W) 6.5
25.0 APP (W) 7.2
30.0
APP (W)
APP (W) 5.1
6.5
20.0
25.0
APP (W) 5.1
15.0
20.0
10.0
15.0
5.0
10.0 rpm
00
00
0
00
00
00
00
00
00
00
70
80
90
11
14
17
10
12
13
15
16
18
5.0 rpm
00
00
0
00
00
00
00
00
00
00
70
80
90
11
14
17
10
12
13
15
16
18
m3/h
15.0
m3/h
14.0 APP 13/1500
15.0 APP 13/1200
13.0
14.0 APP 13/1500
12.0 APP 13/1200
13.0 APP 11/1200 APP 11/1500
11.0
12.0
10.0 APP 11/1200 APP 11/1500
11.0
9.0
10.0
8.0
9.0
7.0
8.0
6.0
7.0
5.0
6.0
4.0 rpm
5.0
00 000
0
00 100
00 200
00 300
00 400
00 500
70
80
90
4.0 rpm
1
1
0
0
70
80
90
10
11
12
13
14
15
gpm
65.0
gpm
60.0
65.0 APP 13/1500
APP 13/1200
55.0
60.0 APP 13/1500
APP 13/1200
50.0
55.0 APP 11/1200 APP 11/1500
45.0
50.0 APP 11/1200 APP 11/1500
40.0
45.0
35.0
40.0
30.0
35.0
25.0
30.0
20.0
25.0 rpm
0
00 000
00 100
0
00 200
00 300
00 400
00 500
70
80
90
20.0 rpm
1
1
0
0
70
80
90
10
11
12
13
14
15
m3/h
22.0 APP 22/1200
m 3
/h
20.0
22.0 19/1200
APP 22/1200
18.0 APP 17/1200
20.0 APP 16/1200
16.0 APP 19/1200
18.0 APP 17/1200
14.0 APP 16/1200
16.0
12.0
14.0
10.0
12.0
8.0
10.0
6.0 rpm
8.0
00
00
00
0
0
70
80
90
12
10
11
6.0 rpm
00
gpm
00
00
0
0
70
80
90
12
10
11
APP 22/1200
90.0
gpm
80.0 APP 22/1200
19/1200
90.0
APP 17/1200
70.0 APP
APP 16/1200
19/1200
80.0
APP 17/1200
60.0 APP 16/1200
70.0
50.0
60.0
40.0
50.0
30.0 rpm
40.0
00
00
00
0
0
70
80
90
12
10
11
30.0 rpm
00
00
00
0
0
70
80
90
12
10
11
m3/h
m 3
/h
22.0 APP 22/1500
22.0 APP 22/1500
20.0
20.0 APP 19/1500
18.0 APP 19/1500
18.0 APP 17/1500
16.0 16/1500
APP 17/1500
16.0 APP 16/1500
14.0
14.0
12.0
12.0
10.0
10.0
8.0
8.0
6.0 rpm
6.0 rpm
00 00
00 00
0 0
0 0
0 0
00 00
00 00
00 00
00 00
70 70
80 80
90 90
11 11
14 14
10 10
12 12
13 13
15 15
gpm
gpm APP 22/1500
90.0 APP 22/1500
90.0
APP 19/1500
80.0
APP 19/1500
80.0
APP 17/1500
70.0 16/1500
APP 17/1500
70.0 APP 16/1500
60.0
60.0
50.0
50.0
40.0
40.0
30.0 rpm
30.0 rpm
00 00
00 00
0 0
0 0
0 0
00 00
00 00
00 00
00 00
70 70
80 80
90 90
11 11
14 14
10 10
12 12
13 13
15 15
m3/h
32.0
APP 30/1200
m3/h
30.0
32.0
28.0 APP 30/1200
30.0 APP 26/1200
26.0
28.0 APP 24/1200
24.0 APP 26/1200
26.0
APP 24/1200
22.0 APP 21/1200
24.0
20.0
22.0 APP 21/1200
18.0
20.0
16.0
18.0
14.0
16.0
12.0 rpm
14.0
00
00
00
0
0
70
80
90
11
12
10
12.0 rpm
00
00
00
0
0
70
80
90
11
12
10
gpm
140.0
gpm APP 30/1200
130.0
140.0
120.0 APP 30/1200
130.0 APP 26/1200
110.0 APP 24/1200
120.0 APP 26/1200
100.0
110.0 APP 24/1200
APP 21/1200
90.0
100.0
80.0 APP 21/1200
90.0
70.0
80.0
60.0
70.0
50.0 rpm
60.0
00
00
00
0
0
70
80
90
11
12
10
50.0 rpm
00
00
00
0
0
70
80
90
11
12
10
m3/h
40.0 APP 38/1500
m37.5
3
/h
40.0 APP 38/1500
35.0
37.5
32.5 APP 30/1500
35.0
30.0
32.5 APP 30/1500
27.5 APP 26/1500
30.0
25.0 APP 24/1500
27.5 APP
22.5 APP26/1500
21/1500
25.0 APP 24/1500
20.0
22.5 APP 21/1500
17.5
20.0
15.0
17.5
12.5
15.0
10.0 rpm
12.5
00
00
00
00
00
00
0
0
70
80
11
12
15
10
13
14
10.0 rpm
00
00
00
00
00
00
0
0
70
80
11
12
15
10
13
14
gpm
170.0 APP 38/1500
gpm
160.0
170.0 APP 38/1500
150.0
160.0
140.0 APP 30/1500
150.0
130.0
140.0 APP 30/1500
120.0
APP 26/1500
130.0
110.0 APP 24/1500
120.0
100.0 APP26/1500
21/1500
APP
110.0 APP 24/1500
90.0
100.0
80.0 APP 21/1500
90.0
70.0
80.0
60.0
70.0
50.0
60.0 rpm
40.0
50.0
00
00
00
00
00
00
0
0
70
80
90
12
15
10
11
13
14
40.0 rpm
00
00
00
00
00
00
0
0
70
80
90
12
15
10
11
13
14
m3/h
45.0
m3
/h APP 43/1700
42.5
45.0 APP 43/1700
40.0
42.5
37.5
40.0
35.0
37.5
32.5
35.0
30.0
32.5
27.5
30.0
25.0
27.5
22.5
25.0
20.0
22.5
17.5
20.0
15.0
17.5
12.5
15.0
rpm
10.0
12.5
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
0
0
0
rpm
80 80
90 90
70 70
10.0
11 11
12 12
13 13
14 14
15 15
16 16
17 17
10 10
0
0
0
gpm
200.0
gpm APP 43/1700
190.0
200.0
180.0 APP 43/1700
190.0
170.0
180.0
160.0
170.0
150.0
160.0
140.0
150.0
130.0
140.0
120.0
130.0
110.0
120.0
90.0
110.0
80.0
90.0
50.0
80.0
60.0
50.0
40.0 rpm
60.0
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
0
0
0
rpm
80 80
90 90
70 70
40.0
11 11
12 12
13 13
14 14
15 15
16 16
17 17
10 10
0
0
0
6 Flushing valve curves All pumps except APP (W) 5.1 - 10.2 are supplied
with an integrated flushing valve that allows the
fluid to flow from inlet to the outlet, when the
pump is not running.
Pressure [barg]
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0 Flow [l/min]
0
10
12
14
16
18
6.2 APP 1.5–3.5 integrated flushing valve
Pressure [barg]
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0 Flow [l/min]
0
10
12
14
16
18
Pressure [barg]
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0 Flow [l/min]
0
20
40
60
80
0
10
12
14
16
18
6.5 APP 16–22 integrated flushing valve
Pressure [barg]
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0 Flow [l/min]
0
50
0
45
10
15
20
25
30
35
40
Pressure [barg]
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0 Flow [l/min]
0
0
10
20
30
40
50
60
7. Motor requirements The power requirements can be determined using one of the following guiding equations:
1 hp = 0.75 kW
1 gpm = 3.79 l/min
1 m3/h = 4.40 gpm
1 kW = 1.34 hp
1 l/min = 0.26 gpm
1 gpm = 0.23 m3/h
7.1 Calculation factor for APP 0.6-1.0 7.5 Calculation factor for APP 16-22
50
316L
40
30
20 -
100 1000 10 000 100 000 CI
ppm
160 1600 16000 160000 NaCI
ppm
9. Installation See example below on how to mount the pump If alternative mounting is required. please
and connect it to an electric motor or combus- contact your Danfoss sales representative for
tion engine (special coupling). further information.
A: Pump
B: Bell housing
C: Flexible coupling
D: Motor shaft
E: Motor
A
B
C D E
A mm B mm C mm D mm E mm F mm G mm H mm
Pump IEC Electric motor
(inch) (inch) (inch) (inch) (inch) (inch) (inch) (inch)
200 245 90 140 100 265 100 131
APP 0.6 1.5 kW, IEC 90S-2
(7.87) (9.64) (3.54) (5.51) (3.94) (10.43) (3.94) (5.16)
200 245 90 140 125 290 100 131
APP 0.8 2.2 kW, IEC 90L-2
(7.87) (9.64) (3.54) (5.51) (4.92) (11.42) (3.94) (5.16)
250 260 100 160 140 325 120 131
APP 1.0 3.0 kW, IEC 100L-2
(9.84) (10.23) (3.94) (6.30) (5.51) (12.80) (4.72) (5.16)
250 260 100 160 140 325 120 166
APP 1.5 3.0 kW, IEC 100L-2
(9.84) (10.23) (3.94) (6.30) (5.51) (12.80) (4.72) (6.54)
250 290 112 190 140 340 120 166
APP 1.8 4.0 kW, IEC 112M-2
(9.84) (11.42) (4.41) (7.48) (5.51) (13.39) (4.72) (6.54)
300 338 132 216 140 403 144 166
APP 2.2 5.5 kW, IEC 132S1-2
(11.81) (13.31) (5.20) (8.50) (5.51) (15.87) (5.67) (6.54)
300 338 132 216 178 403 144 166
APP 2.5 7.5 kW, IEC 132S2-2
(11.81) (13.31) (5.20) (8.50) (7.01) (15.87) (5.67) (6.54)
350 422 160 254 210 505 188 166
APP 3.0 11 kW, IEC 160M1-2
(13.78) (17.40) (6.30) (10.0) (8.27) (19.88) (7.40) (6.54)
350 422 160 254 210 505 188 166
APP 3.5 11 kW, IEC 160M1-2
(13.78) (17.40 (6.30) (10.0) (8.27) (19.88) (7.40) (6.54)
A mm B mm C mm D mm E mm F mm
Pump IEC Electric motor
(inch) (inch) (inch) (inch) (inch) (inch)
350 437 160 254 210 498
APP 5.1 11 kW, HUC2 160 M-4
(13.78) (17.20) (6.30) (10.0) (8.27) (19.61)
350 437 160 254 254 542
APP 6.5 15 kW, HUC2 160 L-4
(13.78) (17.20) (6.30) (10.0) (10.0) (21.34)
350 437 160 254 254 542
APP 7.2 15 kW, HUC2 160 L-4
(13.78) (17.20) (6.30) (10.0) (10.0) (21.34)
350 473 180 279 241 578
APP 8.2 18.5 kW, HUC2 180 M-4
(13.78) (18.62) (7.09) (10.98) (9.49) (22.76)
350 473 180 279 279 616
APP 10.2 22 kW, HUC2 180 L-4
(13.78) (18.62) (7.09) (10.98) (10.98) (24.25)
400 513 200 318 305 659
APP 10.2 30 kW, HUC2 200 L-4
(15.75) (20.20) (7.87) (12.52) (12.01) (25.94)
A mm B mm C mm D mm E mm F mm G mm
Pump IEC Electric motor
(inch) (inch) (inch) (inch) (inch) (inch) (inch)
350 473 180 279 241 578 204
APP 11 22 kW, IEC 180L-4
(13.78) (18.62) (7.09) (10.98) (9.49) (22.76) (8.03)
400 513 200 318 305 659 204
APP 11 30 kW, IEC 200L-4
(15.75) (20.20) (7.87) (12.52) (12.01) (25.94) (8.03)
450 561 225 356 286 667 234
APP 13 37 kW, IEC 225S-4
(17.72) (22.09) (8.86) (14.02) (11.26) (26.26) (9.21)
A mm B mm C mm D mm E mm F mm
G mm
Pump (inch) (inch) (inch) (inch) (inch) (inch) IEC Electric motor
(inch)
[P] [HD] [H] [A] [B]) [LB]
450 560 225 356 286 675 262
APP 16 37 kW, IEC 225 S4
(17.72) (22.05) (8.86) (14.02) (11.26) (26.57) (10.31)
450 560 225 356 311 705 262
APP 17 45 kW, IEC 225 M4
(17.72) (22.05) (8.86) (14.02) (12.24) (27.76) (10.31)
550 615 250 406 349 775 265
APP 19 55 kW, IEC 250 M4
(21.63) (24.22) (9.84) (15.98) (13.74) (30.51) (10.43)
550 680 280 457 368 835 265
APP 22 75 kW, IEC 280 S4
(21.63) (26.77) (11.02) (17.99) (14.48) (32.87) (10.43)
A mm B mm C mm D mm E mm F mm
Pump IEC Electric motor
(inch) (inch) (inch) (inch) (inch) (inch)
550 635 250 406 349 770
APP 21-24 55 kW, IEC 250 M-4
(21.65) (25.0) (9.84) (15.98) (13.74) (30.31)
550 693 280 457 368 845
APP 24-26 75 kW, IEC 280 S-4
(21.65) (27.28) (11.02) (17.99) (14.49) (33.27)
550 693 280 457 419 895
APP 26-38 90 kW, IEC 280 M-4
(21.65) (27.28) (11.02) (17.99) (16.50) (35.24)
11.6 APP 43
A mm B mm C mm D mm E mm F mm
Pump IEC Electric motor
(inch) (inch) (inch) (inch) (inch) (inch)
660 861 315 508 406 1038
APP 43 110 kW, IEC 315 S-4
(25.98) (33.90) (12.40) (20.00) (15.98) (40.87)
Due to the design and dimensions of an APP 43 If this dampening flange for some reason is
pump, bell housing and IEC motor, a dampening deselected, an extension for the non-return
flange on the bell housing is standard when an valve may be needed in order to mount the pipe
IEC 315 motor is selected. or hose with Victaulic clamps. For details and
relevant accessories, please contact Danfoss.