You are on page 1of 21

ASTARO-MIB DEFINITIONS ::= BEGIN

--
-- Astaro Notification Definition
--
-- .1.3.6.1.4.1.9789
-- .iso.org.dod.internet.private.enterprises.astaro
-- .1500 (.notification)
-- .0 (DEBUG)
-- .1 (INFO)
-- .2 (WARN)
-- .3 (CRIT)
-- .0 - .999 (<notificationID>)
-- .1501 (.notificationGroup)
--

IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
enterprises
FROM SNMPv2-SMI
NOTIFICATION-GROUP
FROM SNMPv2-CONF ;

--
-- top level
--

astaro MODULE-IDENTITY
LAST-UPDATED "201605060000Z"
ORGANIZATION "Sophos Ltd"
CONTACT-INFO
"Sophos Ltd.
The Pentagon
Abingdon Science Park
Abingdon OX14 3YP
United Kingdom

Phone: +44 (0)1235 559933


Email: customercare@sophos.com
www.sophos.com"
DESCRIPTION
"The MIB module for Notification Events

Copyright (C) 2009,2016 by Sophos Ltd."


REVISION "201605060000Z"
DESCRIPTION
"Change descriptors to conform to RFC 2578"
REVISION "200812170000Z"
DESCRIPTION
"Initial version"
::= { enterprises 9789 }

notification OBJECT IDENTIFIER ::= { astaro 1500 }


notificationGroup OBJECT IDENTIFIER ::= { astaro 1501 }

--
-- Notification severity
--

debug OBJECT IDENTIFIER ::= { notification 0 }


info OBJECT IDENTIFIER ::= { notification 1 }
warn OBJECT IDENTIFIER ::= { notification 2 }
crit OBJECT IDENTIFIER ::= { notification 3 }

--
-- Notifications
--
sophosUTMNotificationsBASE NOTIFICATION-GROUP
NOTIFICATIONS { sophosUTMNotificationCRIT025, sophosUTMNotificationCRIT026,
sophosUTMNotificationCRIT054, sophosUTMNotificationCRIT060,
sophosUTMNotificationCRIT065, sophosUTMNotificationINFO000,
sophosUTMNotificationINFO005, sophosUTMNotificationINFO006,
sophosUTMNotificationINFO007, sophosUTMNotificationINFO010,
sophosUTMNotificationINFO011, sophosUTMNotificationINFO020,
sophosUTMNotificationINFO021, sophosUTMNotificationINFO022,
sophosUTMNotificationINFO040, sophosUTMNotificationINFO050,
sophosUTMNotificationINFO051, sophosUTMNotificationINFO053,
sophosUTMNotificationINFO062, sophosUTMNotificationINFO063,
sophosUTMNotificationINFO065, sophosUTMNotificationINFO094,
sophosUTMNotificationINFO095, sophosUTMNotificationINFO601,
sophosUTMNotificationWARN005, sophosUTMNotificationWARN006,
sophosUTMNotificationWARN007, sophosUTMNotificationWARN025,
sophosUTMNotificationWARN030, sophosUTMNotificationWARN031,
sophosUTMNotificationWARN032, sophosUTMNotificationWARN033,
sophosUTMNotificationWARN040, sophosUTMNotificationWARN052,
sophosUTMNotificationWARN061, sophosUTMNotificationWARN070,
sophosUTMNotificationWARN094, sophosUTMNotificationWARN136,
sophosUTMNotificationWARN201, sophosUTMNotificationWARN531 }
STATUS current
DESCRIPTION
"Notification category Base System"
::= { notificationGroup 0 }

sophosUTMNotificationsSELFMON NOTIFICATION-GROUP
NOTIFICATIONS { sophosUTMNotificationINFO105, sophosUTMNotificationINFO106,
sophosUTMNotificationINFO107, sophosUTMNotificationINFO108,
sophosUTMNotificationINFO109, sophosUTMNotificationINFO110,
sophosUTMNotificationINFO111, sophosUTMNotificationINFO112,
sophosUTMNotificationINFO114, sophosUTMNotificationINFO115,
sophosUTMNotificationINFO116, sophosUTMNotificationINFO117,
sophosUTMNotificationINFO118, sophosUTMNotificationINFO119,
sophosUTMNotificationINFO120, sophosUTMNotificationINFO121,
sophosUTMNotificationINFO122, sophosUTMNotificationINFO123,
sophosUTMNotificationINFO124, sophosUTMNotificationINFO125,
sophosUTMNotificationINFO126, sophosUTMNotificationINFO127,
sophosUTMNotificationINFO128, sophosUTMNotificationINFO129,
sophosUTMNotificationINFO130, sophosUTMNotificationINFO131,
sophosUTMNotificationINFO132, sophosUTMNotificationINFO133,
sophosUTMNotificationINFO134, sophosUTMNotificationINFO135,
sophosUTMNotificationINFO136, sophosUTMNotificationINFO138,
sophosUTMNotificationINFO139, sophosUTMNotificationINFO140,
sophosUTMNotificationINFO141, sophosUTMNotificationINFO142,
sophosUTMNotificationINFO143, sophosUTMNotificationINFO144,
sophosUTMNotificationINFO145, sophosUTMNotificationINFO146,
sophosUTMNotificationINFO147, sophosUTMNotificationINFO148,
sophosUTMNotificationINFO149, sophosUTMNotificationINFO150,
sophosUTMNotificationINFO152, sophosUTMNotificationINFO153,
sophosUTMNotificationINFO154, sophosUTMNotificationINFO163,
sophosUTMNotificationINFO164, sophosUTMNotificationINFO170,
sophosUTMNotificationINFO171, sophosUTMNotificationINFO172,
sophosUTMNotificationINFO173, sophosUTMNotificationINFO175,
sophosUTMNotificationINFO176, sophosUTMNotificationINFO177,
sophosUTMNotificationINFO178, sophosUTMNotificationINFO179,
sophosUTMNotificationINFO180, sophosUTMNotificationINFO181,
sophosUTMNotificationINFO182, sophosUTMNotificationINFO183,
sophosUTMNotificationINFO184, sophosUTMNotificationINFO185,
sophosUTMNotificationINFO186, sophosUTMNotificationINFO187,
sophosUTMNotificationINFO188, sophosUTMNotificationINFO189,
sophosUTMNotificationINFO190, sophosUTMNotificationINFO191,
sophosUTMNotificationINFO192, sophosUTMNotificationINFO193,
sophosUTMNotificationWARN129, sophosUTMNotificationWARN160,
sophosUTMNotificationWARN161, sophosUTMNotificationWARN162 }
STATUS current
DESCRIPTION
"Notification category Selfmonitor"
::= { notificationGroup 1 }

sophosUTMNotificationsUP2DATE NOTIFICATION-GROUP
NOTIFICATIONS { sophosUTMNotificationCRIT310, sophosUTMNotificationCRIT311,
sophosUTMNotificationINFO301, sophosUTMNotificationINFO302,
sophosUTMNotificationINFO306, sophosUTMNotificationINFO310,
sophosUTMNotificationINFO320, sophosUTMNotificationINFO321,
sophosUTMNotificationINFO322 }
STATUS current
DESCRIPTION
"Notification category Up2Date"
::= { notificationGroup 2 }

sophosUTMNotificationsREPORTING NOTIFICATION-GROUP
NOTIFICATIONS { sophosUTMNotificationCRIT712, sophosUTMNotificationINFO700,
sophosUTMNotificationINFO710, sophosUTMNotificationINFO720,
sophosUTMNotificationINFO721, sophosUTMNotificationINFO722,
sophosUTMNotificationINFO723, sophosUTMNotificationINFO724,
sophosUTMNotificationINFO725, sophosUTMNotificationINFO726,
sophosUTMNotificationINFO727, sophosUTMNotificationINFO728,
sophosUTMNotificationINFO729, sophosUTMNotificationWARN711,
sophosUTMNotificationWARN715, sophosUTMNotificationWARN726,
sophosUTMNotificationWARN727, sophosUTMNotificationWARN728,
sophosUTMNotificationWARN729 }
STATUS current
DESCRIPTION
"Notification category Logging / Reporting"
::= { notificationGroup 4 }

sophosUTMNotificationsIPS NOTIFICATION-GROUP
NOTIFICATIONS { sophosUTMNotificationCRIT850, sophosUTMNotificationCRIT852,
sophosUTMNotificationCRIT861, sophosUTMNotificationINFO850,
sophosUTMNotificationINFO852, sophosUTMNotificationWARN850,
sophosUTMNotificationWARN852, sophosUTMNotificationWARN856 }
STATUS current
DESCRIPTION
"Notification category Intrusion Prevention"
::= { notificationGroup 5 }
sophosUTMNotificationsHA NOTIFICATION-GROUP
NOTIFICATIONS { sophosUTMNotificationCRIT027, sophosUTMNotificationCRIT028,
sophosUTMNotificationCRIT080, sophosUTMNotificationCRIT081,
sophosUTMNotificationCRIT082, sophosUTMNotificationCRIT090,
sophosUTMNotificationCRIT091, sophosUTMNotificationCRIT092,
sophosUTMNotificationINFO080, sophosUTMNotificationINFO081,
sophosUTMNotificationINFO083, sophosUTMNotificationINFO090,
sophosUTMNotificationINFO091, sophosUTMNotificationINFO092,
sophosUTMNotificationINFO093, sophosUTMNotificationWARN080,
sophosUTMNotificationWARN090 }
STATUS current
DESCRIPTION
"Notification category HA / Cluster"
::= { notificationGroup 6 }

sophosUTMNotificationsEPP NOTIFICATION-GROUP
NOTIFICATIONS { sophosUTMNotificationWARN501 }
STATUS current
DESCRIPTION
"Notification category Endpoint"
::= { notificationGroup 7 }

sophosUTMNotificationCRIT025 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"License usage: EXCEEDING 100% OF USER COUNT on Sophos UTM"
::= { crit 25 }

sophosUTMNotificationCRIT026 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"License usage: EXCEEDING 110% OF USER COUNT on Sophos UTM"
::= { crit 26 }

sophosUTMNotificationCRIT027 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"License usage: No valid HA license"
::= { crit 27 }

sophosUTMNotificationCRIT028 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"License usage: No valid Cluster license"
::= { crit 28 }

sophosUTMNotificationCRIT054 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"UPS power critical, system shutting down"
::= { crit 54 }

sophosUTMNotificationCRIT060 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Raid degraded: harddisk replacement needed"
::= { crit 60 }

sophosUTMNotificationCRIT065 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"IPv6 Renumbering failed"
::= { crit 65 }

sophosUTMNotificationCRIT080 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"HA System: There is no slave node, please check your HA System"
::= { crit 80 }

sophosUTMNotificationCRIT081 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"HA System: Your installed system versions differ, please check your HA
System"
::= { crit 81 }

sophosUTMNotificationCRIT082 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"HA System: Some interfaces are unplugged, please check your HA System"
::= { crit 82 }

sophosUTMNotificationCRIT090 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Cluster: One or more nodes are dead, please check your Cluster"
::= { crit 90 }

sophosUTMNotificationCRIT091 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Cluster: Your installed system versions differ, please check your
Cluster"
::= { crit 91 }

sophosUTMNotificationCRIT092 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Cluster: Some interfaces are unplugged, please check your Cluster"
::= { crit 92 }

sophosUTMNotificationCRIT310 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Up2Date prefetch failed"
::= { crit 310 }

sophosUTMNotificationCRIT311 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Firmware Up2Date installation failed"
::= { crit 311 }

sophosUTMNotificationCRIT712 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"System shut down due to full log file partition"
::= { crit 712 }

sophosUTMNotificationCRIT850 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Intrusion Prevention Alert"
::= { crit 850 }

sophosUTMNotificationCRIT852 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Intrusion Prevention Alert (Packet dropped)"
::= { crit 852 }

sophosUTMNotificationCRIT861 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Advanced Threat Protection Alert"
::= { crit 861 }

sophosUTMNotificationINFO000 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"System was restarted"
::= { info 0 }

sophosUTMNotificationINFO005 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Successful WebAdmin login"
::= { info 5 }

sophosUTMNotificationINFO006 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Successful SSH login"
::= { info 6 }

sophosUTMNotificationINFO007 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Successful console login"
::= { info 7 }

sophosUTMNotificationINFO010 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Configuration Auto Backup"
::= { info 10 }

sophosUTMNotificationINFO011 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Configuration Backup File"
::= { info 11 }

sophosUTMNotificationINFO020 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"License expiry: a feature will expire"
::= { info 20 }

sophosUTMNotificationINFO021 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"License expiry: a feature expires today"
::= { info 21 }

sophosUTMNotificationINFO022 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"License expiry: a feature expired"
::= { info 22 }

sophosUTMNotificationINFO040 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Remote Configuration Manager - System Information"
::= { info 40 }

sophosUTMNotificationINFO050 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"UPS device connected"
::= { info 50 }

sophosUTMNotificationINFO051 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"UPS device disconnected"
::= { info 51 }

sophosUTMNotificationINFO053 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"UPS power restored"
::= { info 53 }

sophosUTMNotificationINFO062 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Raid rebuild process started"
::= { info 62 }

sophosUTMNotificationINFO063 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Raid rebuild process finished"
::= { info 63 }

sophosUTMNotificationINFO065 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"IPv6 Renumbering successful"
::= { info 65 }

sophosUTMNotificationINFO080 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"HA node is now Master"
::= { info 80 }

sophosUTMNotificationINFO081 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"HA node is now Slave"
::= { info 81 }

sophosUTMNotificationINFO083 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"HA System is active and fully functional"
::= { info 83 }

sophosUTMNotificationINFO090 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Cluster node is now Master"
::= { info 90 }

sophosUTMNotificationINFO091 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Cluster node is now Slave"
::= { info 91 }

sophosUTMNotificationINFO092 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Cluster node is now Worker"
::= { info 92 }

sophosUTMNotificationINFO093 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Cluster is active and fully functional"
::= { info 93 }

sophosUTMNotificationINFO094 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Upgrade: download successful"
::= { info 94 }

sophosUTMNotificationINFO095 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"RED Unlock code"
::= { info 95 }

sophosUTMNotificationINFO105 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"User Authenticator not running - restarted"
::= { info 105 }

sophosUTMNotificationINFO106 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Cron Task Scheduler not running - restarted"
::= { info 106 }

sophosUTMNotificationINFO107 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"WebAdmin webserver not running - restarted"
::= { info 107 }

sophosUTMNotificationINFO108 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Ssh server not running - restarted"
::= { info 108 }

sophosUTMNotificationINFO109 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Dhcp client not running - restarted"
::= { info 109 }

sophosUTMNotificationINFO110 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Configuration daemon not running - restarted"
::= { info 110 }

sophosUTMNotificationINFO111 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Syslog server not running - restarted"
::= { info 111 }

sophosUTMNotificationINFO112 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Middleware not running - restarted"
::= { info 112 }

sophosUTMNotificationINFO114 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Ulogd not running - restarted"
::= { info 114 }

sophosUTMNotificationINFO115 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Snort not running - restarted"
::= { info 115 }

sophosUTMNotificationINFO116 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Snmpd daemon not running - restarted"
::= { info 116 }
sophosUTMNotificationINFO117 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Pop3 proxy not running - restarted"
::= { info 117 }

sophosUTMNotificationINFO118 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Ftp proxy not running - restarted"
::= { info 118 }

sophosUTMNotificationINFO119 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Named not running - restarted"
::= { info 119 }

sophosUTMNotificationINFO120 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Sockd not running - restarted"
::= { info 120 }

sophosUTMNotificationINFO121 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Identd not running - restarted"
::= { info 121 }

sophosUTMNotificationINFO122 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Dhcpd not running - restarted"
::= { info 122 }

sophosUTMNotificationINFO123 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"IRQd not running - restarted"
::= { info 123 }

sophosUTMNotificationINFO124 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Ufod not running - restarted"
::= { info 124 }

sophosUTMNotificationINFO125 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Smtpd not running - restarted"
::= { info 125 }

sophosUTMNotificationINFO126 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Dyndns not running - restarted"
::= { info 126 }
sophosUTMNotificationINFO127 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Spam filter not running - restarted"
::= { info 127 }

sophosUTMNotificationINFO128 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Pptpd not running - restarted"
::= { info 128 }

sophosUTMNotificationINFO129 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"IPv6 Watchdog not running - restarted"
::= { info 129 }

sophosUTMNotificationINFO130 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Winbindd not running - restarted"
::= { info 130 }

sophosUTMNotificationINFO131 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Xinetd not running - restarted"
::= { info 131 }

sophosUTMNotificationINFO132 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"ACC core daemon not running - restarted"
::= { info 132 }

sophosUTMNotificationINFO133 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"ACC up2date cache not running - restarted"
::= { info 133 }

sophosUTMNotificationINFO134 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"IPsec starter not running - restarted"
::= { info 134 }

sophosUTMNotificationINFO135 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"IPsec pluto not running - restarted"
::= { info 135 }

sophosUTMNotificationINFO136 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"ACC device agent not running - restarted"
::= { info 136 }

sophosUTMNotificationINFO138 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Smtp scan daemon not running - restarted"
::= { info 138 }

sophosUTMNotificationINFO139 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Content Filter Framework not running - restarted"
::= { info 139 }

sophosUTMNotificationINFO140 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Notification Daemon not running - restarted"
::= { info 140 }

sophosUTMNotificationINFO141 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Http proxy not running - restarted"
::= { info 141 }

sophosUTMNotificationINFO142 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"OSPF daemon (ospfd) not running - restarted"
::= { info 142 }

sophosUTMNotificationINFO143 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Dynamic routing daemon (quagga) not running - restarted"
::= { info 143 }

sophosUTMNotificationINFO144 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"HAL (Hardware Abstraction Layer) system daemon not running - restarted"
::= { info 144 }

sophosUTMNotificationINFO145 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Udev (system device manager) daemon not running - restarted"
::= { info 145 }

sophosUTMNotificationINFO146 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Dbus (application device bus) system daemon not running - restarted"
::= { info 146 }

sophosUTMNotificationINFO147 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"NTP (network time synchronization) daemon not running - restarted"
::= { info 147 }

sophosUTMNotificationINFO148 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"L2TP-over-IPsec daemon not running - restarted"
::= { info 148 }

sophosUTMNotificationINFO149 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Application Control daemon not running - restarted"
::= { info 149 }

sophosUTMNotificationINFO150 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Root partition is filling up - please check"
::= { info 150 }

sophosUTMNotificationINFO152 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Network Monitor not running - restarted"
::= { info 152 }

sophosUTMNotificationINFO153 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Log Disk is filling up - please check"
::= { info 153 }

sophosUTMNotificationINFO154 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Data Disk is filling up - please check"
::= { info 154 }

sophosUTMNotificationINFO163 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Log Disk is short of inodes - please check"
::= { info 163 }

sophosUTMNotificationINFO164 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Data Disk is short of inodes - please check"
::= { info 164 }

sophosUTMNotificationINFO170 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"HA confd sync daemon not running - restarted"
::= { info 170 }

sophosUTMNotificationINFO171 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"HA up2date proxy not running - restarted"
::= { info 171 }

sophosUTMNotificationINFO172 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"HA conntrack daemon not running - restarted"
::= { info 172 }

sophosUTMNotificationINFO173 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"HA csync2 daemon not running - restarted"
::= { info 173 }

sophosUTMNotificationINFO175 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"IPv6 Teredo Tunnel Broker client not running - restarted"
::= { info 175 }

sophosUTMNotificationINFO176 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"IPv6 gogo6 Tunnel Broker client not running - restarted"
::= { info 176 }

sophosUTMNotificationINFO177 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"IPv6 Routing Advertisement daemon not running - restarted"
::= { info 177 }

sophosUTMNotificationINFO178 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"IPv6 Hurricane Tunnel Broker client not running - restarted"
::= { info 178 }

sophosUTMNotificationINFO179 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"DNS resolver not running - restarted"
::= { info 179 }

sophosUTMNotificationINFO180 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Client Authentication daemon not running - restarted"
::= { info 180 }

sophosUTMNotificationINFO181 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Service Monitor not running - restarted"
::= { info 181 }

sophosUTMNotificationINFO182 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Job queue manager (atd) not running - restarted"
::= { info 182 }

sophosUTMNotificationINFO183 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"BGP daemon (bgpd) not running - restarted"
::= { info 183 }

sophosUTMNotificationINFO184 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"RED server not running - restarted"
::= { info 184 }

sophosUTMNotificationINFO185 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"RED client not running - restarted"
::= { info 185 }

sophosUTMNotificationINFO186 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Confd request queuer not running - restarted"
::= { info 186 }

sophosUTMNotificationINFO187 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Confd queue runner not running - restarted"
::= { info 187 }

sophosUTMNotificationINFO188 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"urid not running - restarted"
::= { info 188 }

sophosUTMNotificationINFO189 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Web Application Firewall not running - restarted"
::= { info 189 }

sophosUTMNotificationINFO190 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Support access daemon not running - restarted"
::= { info 190 }

sophosUTMNotificationINFO191 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"RPM database restored"
::= { info 191 }
sophosUTMNotificationINFO192 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"RRD cache daemon not running - restarted"
::= { info 192 }

sophosUTMNotificationINFO193 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"REST daemon not running - restarted"
::= { info 193 }

sophosUTMNotificationINFO301 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"New Firmware Up2Date is ready for installation"
::= { info 301 }

sophosUTMNotificationINFO302 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"New Firmware Up2Date installed"
::= { info 302 }

sophosUTMNotificationINFO306 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"New Pattern Up2Dates installed"
::= { info 306 }

sophosUTMNotificationINFO310 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Up2Date prefetch is working again"
::= { info 310 }

sophosUTMNotificationINFO320 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Database Conversion Started"
::= { info 320 }

sophosUTMNotificationINFO321 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Database Conversion Adjourned"
::= { info 321 }

sophosUTMNotificationINFO322 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Database Conversion Finished"
::= { info 322 }

sophosUTMNotificationINFO601 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Your Hotspot password"
::= { info 601 }
sophosUTMNotificationINFO700 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Daily log file archive"
::= { info 700 }

sophosUTMNotificationINFO710 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Log file partition is filling up"
::= { info 710 }

sophosUTMNotificationINFO720 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Daily Executive Report"
::= { info 720 }

sophosUTMNotificationINFO721 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Weekly Executive Report"
::= { info 721 }

sophosUTMNotificationINFO722 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Monthly Executive Report"
::= { info 722 }

sophosUTMNotificationINFO723 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Daily Executive Report"
::= { info 723 }

sophosUTMNotificationINFO724 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Weekly Executive Report"
::= { info 724 }

sophosUTMNotificationINFO725 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Monthly Executive Report"
::= { info 725 }

sophosUTMNotificationINFO726 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"VPN connection using Site-to-Site is up again"
::= { info 726 }

sophosUTMNotificationINFO727 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"RED connection is up again"
::= { info 727 }

sophosUTMNotificationINFO728 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Access Point is online again"
::= { info 728 }

sophosUTMNotificationINFO729 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Mesh Access Point is online again"
::= { info 729 }

sophosUTMNotificationINFO850 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Intrusion Prevention Alert"
::= { info 850 }

sophosUTMNotificationINFO852 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Intrusion Prevention Alert (Packet dropped)"
::= { info 852 }

sophosUTMNotificationWARN005 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Failed WebAdmin login"
::= { warn 5 }

sophosUTMNotificationWARN006 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Failed SSH login"
::= { warn 6 }

sophosUTMNotificationWARN007 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Failed console login"
::= { warn 7 }

sophosUTMNotificationWARN025 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"License usage: EXCEEDING 90% OF USER COUNT on Sophos UTM"
::= { warn 25 }

sophosUTMNotificationWARN030 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Primary internet uplink is down, switching to backup line"
::= { warn 30 }

sophosUTMNotificationWARN031 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Primary internet uplink is back online, switching to main line"
::= { warn 31 }

sophosUTMNotificationWARN032 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Internet uplink is down"
::= { warn 32 }

sophosUTMNotificationWARN033 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Internet uplink is up again"
::= { warn 33 }

sophosUTMNotificationWARN040 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Sophos UTM weak Certificate check - found weak certificates"
::= { warn 40 }

sophosUTMNotificationWARN052 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"UPS on battery power"
::= { warn 52 }

sophosUTMNotificationWARN061 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Raid degraded: defective harddisk inserted"
::= { warn 61 }

sophosUTMNotificationWARN070 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Too many failed logins"
::= { warn 70 }

sophosUTMNotificationWARN080 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"HA selfcheck"
::= { warn 80 }

sophosUTMNotificationWARN090 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Cluster selfcheck"
::= { warn 90 }

sophosUTMNotificationWARN094 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Upgrade failed"
::= { warn 94 }

sophosUTMNotificationWARN129 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Spam Filter cannot query database servers"
::= { warn 129 }

sophosUTMNotificationWARN136 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"ACC server not reachable"
::= { warn 136 }

sophosUTMNotificationWARN160 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Root partition is short of inodes - please check"
::= { warn 160 }

sophosUTMNotificationWARN161 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"RPM Database is corrupted"
::= { warn 161 }

sophosUTMNotificationWARN162 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Corrupted RPM database rebuild failed"
::= { warn 162 }

sophosUTMNotificationWARN201 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"A RED device has been deauthorized automatically"
::= { warn 201 }

sophosUTMNotificationWARN501 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Endpoint Virus Detected"
::= { warn 501 }

sophosUTMNotificationWARN531 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Directory Services synchronization"
::= { warn 531 }

sophosUTMNotificationWARN711 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Log files have been deleted"
::= { warn 711 }

sophosUTMNotificationWARN715 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Remote log file storage failed"
::= { warn 715 }

sophosUTMNotificationWARN726 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"VPN connection using Site-to-Site is down"
::= { warn 726 }

sophosUTMNotificationWARN727 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"RED connection is down"
::= { warn 727 }

sophosUTMNotificationWARN728 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Access Point is offline"
::= { warn 728 }

sophosUTMNotificationWARN729 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Mesh Access Point is offline"
::= { warn 729 }

sophosUTMNotificationWARN850 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Intrusion Prevention Alert"
::= { warn 850 }

sophosUTMNotificationWARN852 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Intrusion Prevention Alert (Packet dropped)"
::= { warn 852 }

sophosUTMNotificationWARN856 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Portscan detected"
::= { warn 856 }

END

You might also like