DESIGN OF FLOOR SLAB S1

ACI 318-11 ELEMENT DESIGN SUMMARY

=====================================

ELEMENT LONG. REINF MOM-X /LOAD TRANS. REINF MOM-Y /LOAD

(SQ.MM/MM) (KN-MM/MM) (SQ.MM/MM) (KN-MM/MM)

FY: 275.998 MPA FC: 25.000 MPA COVER (TOP): 19.050 MM

COVER (BOTTOM): 19.050 MM TH: 100.000 MM

93 TOP : Longitudinal direction - Only minimum steel required.

93 BOTT: Longitudinal direction - Only minimum steel required.

93 TOP : Transverse direction - Only minimum steel required.

93 BOTT: Transverse direction - Only minimum steel required.

93 TOP : 0.200 0.00 / 0 0.200 0.21 / 25

BOTT: 0.200 1.33 / 23 0.200 0.41 / 19

FY: 275.998 MPA FC: 25.000 MPA COVER (TOP): 19.050 MM

COVER (BOTTOM): 19.050 MM TH: 100.000 MM

95 TOP : Longitudinal direction - Only minimum steel required.

95 BOTT: Longitudinal direction - Only minimum steel required.

95 TOP : Transverse direction - Only minimum steel required.

95 BOTT: Transverse direction - Only minimum steel required.

95 TOP : 0.200 0.00 / 0 0.200 0.15 / 27

BOTT: 0.200 1.36 / 21 0.200 0.54 / 17

FY: 275.998 MPA FC: 25.000 MPA COVER (TOP): 19.050 MM

COVER (BOTTOM): 19.050 MM TH: 100.000 MM

96 TOP : Longitudinal direction - Only minimum steel required.

96 BOTT: Longitudinal direction - Only minimum steel required.

96 TOP : Transverse direction - Only minimum steel required.

96 BOTT: Transverse direction - Only minimum steel required.

96 TOP : 0.200 0.00 / 0 0.200 0.20 / 26

BOTT: 0.200 1.06 / 24 0.200 0.22 / 20

FY: 275.998 MPA FC: 25.000 MPA COVER (TOP): 19.050 MM

COVER (BOTTOM): 19.050 MM TH: 100.000 MM

97 TOP : Longitudinal direction - Only minimum steel required.

97 BOTT: Longitudinal direction - Only minimum steel required.

97 TOP : Transverse direction - Only minimum steel required.

97 BOTT: Transverse direction - Only minimum steel required.

97 TOP : 0.200 0.30 / 22 0.200 0.27 / 27

BOTT: 0.200 0.25 / 28 0.200 0.36 / 17


FY: 275.998 MPA FC: 25.000 MPA COVER (TOP): 19.050 MM

COVER (BOTTOM): 19.050 MM TH: 100.000 MM

98 TOP : Longitudinal direction - Only minimum steel required.

98 BOTT: Longitudinal direction - Only minimum steel required.

98 TOP : Transverse direction - Only minimum steel required.

98 BOTT: Transverse direction - Only minimum steel required.

98 TOP : 0.200 0.25 / 25 0.200 0.30 / 26

BOTT: 0.200 0.36 / 19 0.200 0.34 / 20

FY: 275.998 MPA FC: 25.000 MPA COVER (TOP): 19.050 MM

COVER (BOTTOM): 19.050 MM TH: 100.000 MM

99 TOP : Longitudinal direction - Only minimum steel required.

99 BOTT: Longitudinal direction - Only minimum steel required.

99 TOP : Transverse direction - Only minimum steel required.

STAAD SPACE

99 BOTT: Transverse direction - Only minimum steel required.

99 TOP : 0.200 0.00 / 25 0.200 0.18 / 26

BOTT: 0.200 2.61 / 24 0.200 0.66 / 20

FY: 275.998 MPA FC: 25.000 MPA COVER (TOP): 19.050 MM

COVER (BOTTOM): 19.050 MM TH: 100.000 MM

100 TOP : Longitudinal direction - Only minimum steel required.

100 BOTT: Longitudinal direction - Only minimum steel required.

100 TOP : Transverse direction - Only minimum steel required.

100 BOTT: Transverse direction - Only minimum steel required.

100 TOP : 0.200 0.00 / 25 0.200 0.17 / 28

BOTT: 0.200 2.60 / 22 0.200 0.68 / 22

FY: 275.998 MPA FC: 25.000 MPA COVER (TOP): 19.050 MM

COVER (BOTTOM): 19.050 MM TH: 100.000 MM

101 TOP : Longitudinal direction - Only minimum steel required.

101 BOTT: Longitudinal direction - Only minimum steel required.

101 TOP : Transverse direction - Only minimum steel required.

101 BOTT: Transverse direction - Only minimum steel required.

101 TOP : 0.200 0.22 / 25 0.200 0.31 / 28

BOTT: 0.200 0.51 / 19 0.200 0.35 / 18

FY: 275.998 MPA FC: 25.000 MPA COVER (TOP): 19.050 MM

COVER (BOTTOM): 19.050 MM TH: 100.000 MM

102 TOP : Longitudinal direction - Only minimum steel required.


102 TOP : Transverse direction - Only minimum steel required.

102 TOP : 0.200 0.00 / 25 0.200 0.90 / 26

BOTT: 0.453 8.07 / 20 0.272 4.07 / 20

FY: 275.998 MPA FC: 25.000 MPA COVER (TOP): 19.050 MM

COVER (BOTTOM): 19.050 MM TH: 100.000 MM

103 TOP : Longitudinal direction - Only minimum steel required.

103 BOTT: Longitudinal direction - Only minimum steel required.

103 TOP : Transverse direction - Only minimum steel required.

103 TOP : 0.200 1.80 / 28 0.200 0.00 / 26

BOTT: 0.200 2.56 / 22 0.525 7.63 / 18

FY: 275.998 MPA FC: 25.000 MPA COVER (TOP): 19.050 MM

COVER (BOTTOM): 19.050 MM TH: 100.000 MM

104 TOP : Longitudinal direction - Only minimum steel required.

104 BOTT: Longitudinal direction - Only minimum steel required.

104 TOP : Transverse direction - Only minimum steel required.

104 BOTT: Transverse direction - Only minimum steel required.

104 TOP : 0.200 0.00 / 28 0.200 0.46 / 19

BOTT: 0.200 1.96 / 21 0.200 0.36 / 25

FY: 275.998 MPA FC: 25.000 MPA COVER (TOP): 19.050 MM

COVER (BOTTOM): 19.050 MM TH: 100.000 MM

105 TOP : Longitudinal direction - Only minimum steel required.

105 BOTT: Longitudinal direction - Only minimum steel required.

105 TOP : Transverse direction - Only minimum steel required.

105 BOTT: Transverse direction - Only minimum steel required.

105 TOP : 0.200 0.00 / 28 0.200 0.14 / 25

BOTT: 0.200 2.03 / 23 0.200 0.78 / 23

STAAD SPACE

FY: 275.998 MPA FC: 25.000 MPA COVER (TOP): 19.050 MM

COVER (BOTTOM): 19.050 MM TH: 100.000 MM

106 TOP : Longitudinal direction - Only minimum steel required.

106 BOTT: Longitudinal direction - Only minimum steel required.

106 TOP : Transverse direction - Only minimum steel required.

106 BOTT: Transverse direction - Only minimum steel required.

106 TOP : 0.200 0.12 / 25 0.200 0.00 / 25

BOTT: 0.200 0.20 / 19 0.200 0.28 / 23

You might also like