You are on page 1of 45

UNIVERSIDAD NACIONAL AGRARIA LA MOLINA

FACULTAD DE INGENIERÍA AGRÍCOLA

TRABAJO SEMESTRAL

CONCRETO REFORZADO

DISEÑO DE CAÍDA INCLINADA PARA EL CANAL MATRIZ CASA GRANDE

UBICADA EN LA PROGRESIVA 1+1375

PROFESOR : ING. ALFONSO CERNA VASQUEZ

INTEGRANTES : GONZALEZ ALFARO ALEXANDER

LIMA – PERÚ

2017.

1
1. DISEÑO HIDRÁULICO

Requerimientos para el diseño:

Q=2 m3/s

S=0.0022

H=2.5

n= 0.014

Z=1.5 (Villon para canales poco profundo)

EA=1+375

CANAL TRAPEZOIDAL

1
1
𝑄 = 𝑛 × 𝑆2 ×
5
𝐴3
2 ………..(β)
𝑃3

𝐴 = 𝑏𝑦 + 𝑧𝑦 2
Relación recomendada b/y=4 , canales sin
𝑃 = 𝑏 + 2𝑦(1+z2)1/2 ……… (α)
revestir
T=b+2yz , D=A/T
𝑉
𝐹 ……..(ϒ)
√𝐷×𝑔

De las formulas (α),(ϒ) y (β)

2
1 (4𝑦 × 𝑦 + 1.5 × 𝑦 2 )5/3
2= × 0.00220.5 × 2
0.025 (4𝑦 + 2𝑦√1 + 1.52 )3

Y=0.586≈ 0.59 m

Por lo tanto: Bl =y/3 =0.195 m ≈ 0.2 m

H= y+ Bl =0.59 + 0.195=0.785 m

H= 1 m

B=4y=4*(0.59)=2.36m

A=by+2y2=2.089 m2

V=Q/A =2/2.089=0.95 m/s

T= b+2*z*y=2.36m + 2*1.5*0.59

T=4.18

D=A/T=2.089/4.18=0.5
𝑉 0.95
Froude F= = = 0.42 < 1
√𝐷𝑔 √0.5∗9.81

Flujo sub critico

1.1. ANCHO DE TODA LA ESTRUCTURA

18.18×𝑄 0.5 18.18×20.5


B= = = 2.12 ≈ 2.00
10.11+𝑄 10.11+2

3
1.2. DISEÑO DE LA SECCIÓN DE CONTROL

Q < 2.832 m3/s

P=altura ≥ y
Y= tirante normal del agua en el canal
N=P + 2(Sc xT)
Qc =0.2 Qdiseño= 0.2(2 m3/s)=0.4 m3/s
S=0.0022
n= 0.025
z=1.5
b=2.36 m
𝟏 𝟎. 𝟎𝟎𝟐𝟐𝟎.𝟓 × (𝟐. 𝟑𝟔 × 𝒚 + 𝟏. 𝟓 × 𝒚𝟐 )𝟓/𝟑
𝟎. 𝟒 = ×
𝟎. 𝟎𝟐𝟓 (𝟐. 𝟑𝟔 + 𝟐 × 𝒚 × √𝟏 + 𝟏. 𝟓𝟐 )𝟐/𝟑

Y=0.232

Area= by+zy2 =2.36(0.232) + 1.5(0.232)2=0.628 m2

𝑄 0.4
𝑉= = = 0.637 𝑚/𝑠
𝐴 0.628

𝑇 = 𝑏 + 2𝑧𝑦 = 2.36 + 2 ∗ 1.5 ∗ 0.232

T=3.056 m

𝐴 0.628
𝐷= = = 0.205 𝑚
𝑇 3.056
𝑚
𝑉 0.637
𝑠
Froude= = = 0.45 < 1
√𝑔𝐷 √9.81∗0.205

Flujo subcritico

4
1.3. LA ENERGÍAHIDRÁULICA : HE

V2 0.952
He = y + = 0.59 +
2g 2 ∗ 9.81

𝐻𝑒 = 0.636 m

Para 0.4 m3/s

0.6372
0.232 + = 0.252 𝑚
2 ∗ 9.81

Para iniciar el cálculo de la sección de control del tirante crítico, se selecciona el grafico
5a y 5b, con el valor P más pequeño, pero cubriendo tanto el Q =2 m3 /s, como también
0.2Q= 0.4 m3 /s. Se selecciona entonces del gráfico con P= 0.30 m, debe entrarse al
gráfico con la energía He=0.636 m y subir verticalmente hasta la intersección con la línea
horizontal para Q =2m3/s

5
Luego se lee el valor de Sc para la curva de taludes que se encuentra
inmediatamente a la derecha de este punto esta curva es para Sc= 1.5
Debe verificar también de la misma forma,si esta curva también controla 0.2Q=0.4
m3/s, debe entrarse al grafico He= 0.636 m, subir hasta la intersección con la línea
horizontal correspondiente 0.2Q = 0.4 m3/s, la curva inmediatamente a la derecha
del punto muestra Sc= 1.5.
La curva tiene que ser la misma para ambos caudales, para que la sección de control
de la tirante funcione adecuadamente tanto para que el caudal de diseño Q=2m3/s
como para el caudal 0.2Q= 0.4m3/s.
Se observa que ambos puntos de Q Vs He, están poco alejados de la curva Sc=1.5
Repitiendo el mismo procedimiento pero usando esta vez el grafico 5b, podemos
observar que la curva Sc=1.5 se ajusta mejor a los puntos de Q VS HE

Esta sección de control de tirante crítico funcionara satisfactoriamente para los caudales
entre 2m3/s y 0.4 m3/s

Para un P, mínimo 0.3 m, donde SC 1.5 funciona satisfactoriamente para ambos caudales
(2, 0.4) m3/s.

6
Entonces:

P= 0.41 m

SC=1.5

T=0.59 m. Calculado por Q=2 m3/s

N= P+ 2(sc*T) =0,4+2(1.5*0.59)

N=2.18 m

La longitud del vertedero de emergencia (Lo), considerando un levantamiento al nivel del


agua= 0.45 m

𝑸
𝑳𝒐 = 𝟑
(𝟐 ∗ 𝑪 ∗ 𝑯𝟐 )

𝟐
𝑳𝒐 = 3 = 𝟏. 𝟗𝟒 ≈ 𝟐. 𝟎 𝒎
(𝟐 ∗ 1.7 ∗ (0.45)2 )

Nota: dado que se está considerando un levantamiento del agua de 0.45m, se deberá
incrementar el borde libre del canal aguas arriba hasta alcanzar BL= 0.5 m

1.4. DISEÑO DEL TRAMO INCLINADO

Pendiente 1:2 se calculó en base del tirante crítico y el borde libre.


1 1
𝑄2 3 22 3
𝑌𝑐 = ( 2 ) =( 2 ) = 0.46 𝑚
𝐵 ∗𝑔 2 ∗ 9.81

Considerando u borde libre de 0.3 m, la altura de las paredes resulta

0.46 +0.3=0.76

Optamos como altura del tramo inclinado 0.76 m

Caculo de la poza de disipación: ∆𝐻 = 𝐻𝑎 − 𝐻𝑐

V2 0.452
Ha = y + + Ea = 0.59 + + 239.818
2g 2 ∗ 9.81

Ha=240.41

7
V2 0.452
Hc = y + + Ec = 0.59 + + 237.318
2g 2 ∗ 9.81

Hc=237.91 m

∆𝐻 = 240.41 − 237.91 = 2.5 𝑚

∆𝐻 2.5 𝑚
Para calcular y1 e y2 : 𝑦𝑐
= 0.46 𝑚 = 5.43 ≈ 5.4 𝑚

De acuerdo al cuadro 1

∆𝐻 𝑦1⁄ 𝑦1
Para 𝑦𝑐
= 5.4 𝑦𝑐 = 0.251 0.46
= 0.251 y1=0.11m

𝑦2 𝑦2
⁄𝑦1 = 10.73 0.46 = 0.251 y2=0.11m

8
1.5 SELECCIÓN DE TIPO DE ESTANQUE

2 𝑚
𝑉1 = (0.11∗2)1 = 9 𝑠
Se aplica el estanque del
9 USBR tipo II, Porque:
𝐹1 = = 9.67
(9.8 ∗ 0.11)0.5

2 𝑚 F1> 4.5,
𝑉1 = = 0.84
(1.18 ∗ 2)1 𝑠
V1 < 15 m/s

Calculo de dados rompe presión

Longitud de la poza (Ln), en la figura 6d Froude= 8.67

Ln_ =2.8 (Y2=1.18m)


Y2
Ln= 3.3 (longitud de la poza tipo II)

 Altura del bloque del amortiguador (h3)


Con froude8.67

9
ℎ3
Dela figura 6c obtenemos 𝑦1
= 2.5(Y1=0.11)
H3 = 0.27
 Ancho de bloque (0.75 h3) = 0.75(0.27)=0.20m
 Altura del umbral terminal: con f 8.67, en la figura 6c
ℎ4
𝑑1
= 1.5 , h4= 1.5 *0.11=0.16
 Altura y ancho del bloque del canal de descarga (h1)
H1= y1=0.11 m
 Distancia entre los bloques del canal de descarga y los amortiguadores (0.8Y2), de
la figura fa.
0.8*Y2 = 0.8 (1.18) =0.94 m
 Ubicación ene l punto B1 del peso
𝑣𝑜2
𝐸𝐵 = 𝐻𝑐 − [𝑌2 − 2𝑔
]=
0.452
𝐸𝐵 = 297.91 − [1.18 − 14.62] =236.71

Ec= 237.318
 La diferencia de elevación C Y B es 0.608 m ósea mayor a la altura del hasbal
termino (h4)=0.16
 El borde libre de la poza de disipación (BL)
BL= 0.1(VI+V2) = 0.1 (9+1.18) = 1.018 = 1.0 m
Con este borde libre la altura de las paredes laterales es:
Y2+BL=1.8+1.0=2.18 m

1.6 DISEÑO DE POZA


𝐵3
( +𝑍ℎ)−𝐵/2)
2
L=
𝑇𝑔(12°30´)

Transición del canal Trapezoidal

B3=ancho del fondo del canal = 2.36 m

B=ancho de la estructura = 2.0 m

Z= Talud = 1.5

H= altura del canal = 0.59+0.5= 1.09 m

Reemplazando
2.0
( +1.5∗1.09)−2.0/2)
2
L= 𝑇𝑔(12°30´
= 7.37 m

L= 7.4m

10
 La salida de la poza tendrá forma del tipo A la longitud de la transición en tierra es
igual a la entrada o sea L=7.4 m

Entonces:

Altura de paredes (h)= 2.15 m

Ancho de poza = 2.0 m

EB= 236.71

EA= 239.818

Lp=3.3

1.1. Diseño hidráulico de canales abiertos con programa.

CUADRO RESUMEN DE DISEÑO HIDRAULICO


Q=2 m3/s caudal de diseño
pendiente del recorrido del
S=0.0022
canal
H=2.5 desnivel de la caída
n= 0.014 numero mannig
Z=1.5 (Villon para canales poco profundo)
EA=1+375 inicio de la progresiva

Resultados de cálculo del canal aguas arriba y abajo.

A 2.08m2
v 0.45m/s
D 0.5m
BL 0.2m
T 4.18m
Froude 0.42 es menor a 1
flujo sub critico

11
DISEÑO DE TRAMO INCLINADO
BL 0.5 m
Yc 0.46 m más borde libre= 0.7m
Lh 5.4 m

Comparando con el programa de simulación.

Ingresamos los datos, calculados en el diseño de canal de entrada y salida.

Resultados del perfil y planta de la poza.

12
Vista detallada en planta del ancho de la poza, con dados para desminuir la velocidad de
agua.

vista de perfil de la poza.

13
Vista detallada de los dados

14
2. ESTUDIO GEOTÉCNICO

Antes de diseñar una estructura se tiene que tener todos los estudios geotécnicos,
realizando perforaciones de por lo menos 2 metros por debajo del nivel de cimentación,
en cuyo proceso se encuentra la napa freática por lo que se tiene que anotar la
profundidad a la que se encuentre.

Los datos necesarios que se tiene que determinar o estimar en base de los estudios son:

 La textura
 El peso unitario del material seco (𝛾𝑠 = 𝑘𝑔/𝑚3)
 El peso unitario del material bajo el agua (𝛾𝑆𝐴𝑇 = 𝑘𝑔/𝑚3 )
 Ángulo de fricción interna: 𝜙
 Capacidad portante del suelo: 𝜎𝐶 (𝑘𝑔/𝑚3 )

En el cálculo de la presión lateral del terreno sobre una estructura, esto sucede cuando la
construcción es rígida, como es el caso de estructuras de concreto armado, se usa el
factor de presión neutra.

- El factor de presión neutra es:

𝜏𝑛 = (1 − 𝑠𝑒𝑛(𝜙))

15
3. MATERIALES DE CONSTRUCCIÓN

- Los materiales a usarse son: Concreto simple, Concreto ciclópeo y Concreto armado.
Las características que debe poseer este concreto para este tipo de estructuras son las
siguientes:

 Calidad del concreto (para el caso de concreto armado): 𝑓𝑐 ′ = 280 𝑘𝑔/𝑐𝑚2


 Concreto ciclópeo: 𝑓𝑐 ′ = 140 𝑘𝑔/𝑐𝑚2
 Esfuerzo de fluencia: 𝑓𝑦 = 4200 𝑘𝑔/𝑐𝑚2
 Densidad del concreto: 𝛾𝑐 = 2400 𝑘𝑔/𝑐𝑚2

Como también se tiene que verificar el tipo de cemento a usarse (puede ser cemento tipo
I o V) y el recubrimiento necesario, este recubrimiento tiene que resistir todas la
condiciones del medio al que está expuesto.

16
4. ANÁLISIS ESTRUCTURAL
 Para el cálculo estructural se tiene que poner a prueba los diferentes casos extremos
que pueda suceder en la estructura a lo largo de su vida útil (por lo general 40 años).
 Para el diseño de la poza de disipación, los casos extremos que podrán presentarse
son:
 CASO 1: Que la poza de disipación se encuentre sin agua, con relleno a
ambos lados de las paredes laterales de la poza y el nivel freático en la cota
más alta que se pueda observar en campo.
 CASO 2: la poza de disipación esta con agua hasta la cota superior de la
pared lateral, con relleno a ambos lados de la paredes laterales, sin embargo
con el nivel freático por debajo de la cimentación de la estructura.
- Si por A o B esta estructura se encuentra cerca de un camino tiene que
tomarse en cuenta una sobrecarga en el terreno por los efectos de la
pared y la losa.
- Se recomienda por practicidad dar el mismo espesor tanto a las paredes

como a la losa (se toma como valor inicial 𝑑 = , h=altura de la paredes
15
laterales).
Por otra parte, por razones constructivas (vaciado del concreto, se
tomara como espesor mínimo: 𝑑min = 0.15 𝑚

El cálculo se inicia con 𝑑min o 𝑑 = (el valor mayor).
15

Se verifica durante el cálculo si el espesor es suficiente o es necesario


para que cumpla con los diferentes factores de seguridad.
Después se calcula para cada caso
 El momento en el punto A
 El momento en el punto B
 L a seguridad contra la sub – presión
 La presión de la estructura sobre el terreno

17
4.1. CASO 1

La poza de disipación se encuentra sin agua, con relleno a ambos lados de las paredes
laterales de la poza y el nivel freático en la cota más alta observada en el campo.

- La fuerza resultante se genera debido a las siguientes presiones:


- La presión neutra del terreno, genera las 3 siguientes fuerzas componentes:
1
 𝑃𝑠1 = 2
𝛿𝑠 ≉ 𝑚 (ℎ − 𝐻)2 + 600
 𝑃𝑠1 = ≉ 𝑚 (𝛿𝑠 (ℎ − 𝐻)) 𝐻 + 600
1
 𝑃𝑠1 = ≉ 𝑚 𝛿𝑠𝑎𝑡 𝐻 2
2
+ 600

𝛅s= 2260 kg/m2, 𝛿𝑠𝑎𝑡= 1600 kg/m2, h=2.15 m

H= h-profundidad de la napa freática.

H= 2.15-0.6=1.55 m

El factor de presión neutra del terreno es:

tn= (1-sen 𝜙 ) =( 1-sen 32 )̊ =0.4700807358

𝜙 = 32 ̊

18
𝟏
- 𝑃𝑠1 = 𝟐
∗ 𝟎. 𝟒𝟕𝟎𝟎𝟖𝟎𝟕𝟑𝟓𝟖 ∗ 𝟐𝟐𝟔𝟎 ∗ (𝟐. 𝟏𝟓 − 𝟏. 𝟓𝟓)𝟐
𝒌𝒈
- 𝑃𝑠1 = 𝟏𝟗𝟏. 𝟐𝟐𝟖𝟖𝟒𝟑𝟑 𝒎

- 𝑃𝑠2 = 𝟎. 𝟒𝟕𝟎𝟎𝟖𝟎𝟕𝟑𝟓𝟖 ∗ (𝟐𝟐𝟔𝟎 ∗ (𝟐. 𝟏𝟓 − 𝟏. 𝟓𝟓)) ∗ 𝟏. 𝟓𝟓


𝒌𝒈
- 𝑃𝑠2 = 𝟗𝟖𝟖. 𝟎𝟏𝟓𝟔𝟗𝟎𝟓 𝒎

𝒌𝒈
- 𝑃𝑠3 = 𝟎. 𝟒𝟕𝟎𝟎𝟖𝟎𝟕𝟑𝟓𝟖 ∗ 𝟏𝟔𝟎𝟎 ∗ 𝟏. 𝟓𝟓𝟐 𝒎
𝒌𝒈
- 𝑃𝑠3 = 𝟗𝟎𝟑. 𝟒𝟗𝟓𝟏𝟕𝟒 𝒎

Presión de sobrecarga 600 kg/m2

 La presión del agua genera las siguientes fuerzas resultantes.


1
- 𝑃𝑎 = ∗ 100 + 1.552
2
𝑘𝑔
- 𝑃𝑎 = 1201.25 𝑚

El momento en el punto A (es calculado con la ecuación):

1 1 1
- 𝑀𝐴 = ( 𝐻 + (ℎ − 𝐻)𝑃𝑠1 + 𝐻𝑃𝑠2 + 𝐻(𝑃𝑆3 − 𝑃𝑎)
3 2 3
1 1
- 𝑀𝐴 = ( 1.55 + (1.25 − 1.55)191.2288433 + 1.55(988.0156905) +
3 2
1 1 1.55
1.55(903495174 + 1201.25) + 600(1.55 + (2.15 − 1.55) + 600( )
3 3 2
- 𝑀𝐴 = 334.6504758 + 765 + 7121601 + 1087.451673 + 1515
- 𝑀𝐴 = 3702.814309 kg.m

Calculo de la subpresión:

𝑞= (𝐻 + 𝑑2)

𝑞 = 1000(1.55 + 0.2)

𝑞 = 1000(1.55 + 0.2)

𝑞 = 1750 𝑘𝑔/𝑚2

Calculo del momento en el punto B:

1
𝑀𝐵 = 𝑀𝐴 − ( 𝑞(𝑏 + 𝑑1)2 )
8

19
𝑀𝐵 =2595,39243

Como el momento en el punto B es positivo las tensiones darán en la parte inferior de la


losa.

SEGURIDAD CONTRA LA SUBPRESION

El peso de la estructura debe ser F veces mayor que la subpresion del agua para evitar
que la construcción vaya a flotar (F=factor de seguridad ≥ 1.1)

El peso de la estructura se calcula:

𝑃1 = (𝑏 + 2𝑑1 + 2𝑋)(𝑑2)(𝛾𝑐) =1392 kg/m

𝑃2 = 𝑑1. ℎ 𝛾𝑐)=1290 kg/m

𝑃3 = 𝛾𝑠ℎ𝑋(𝑝𝑒𝑠𝑜𝑑𝑒𝑙𝑠𝑢𝑒𝑙𝑜𝑠𝑜𝑏𝑟𝑒𝑜𝑟𝑒𝑗𝑎. 𝑙𝑜𝑠𝑎𝑑𝑒𝑓𝑜𝑛𝑑𝑜) =971,8 kg/m

Fuerza total que ejerce la sub-presión:

𝑄 = 𝑞(𝑏 + 2𝑑1 + 2𝑋)=5075 kg/m

Factor de seguridad

𝑃1+2𝑃2+2𝑃3
𝐹= 𝑄
=1,16563547

𝐹 ≥ 1.10

F es mayor que 1.10 por lo tanto las dimensiones de nuestra posa se encuentran dentro
de los parámetros de seguridad., nuestra fosa no flotara.

PRESIÓN DE LA ESTRUCTURA SOBRE EL TERRENO

(P1+2P2+2P3+Q)
σt = (b+2d1+2X)
=0,028986207

20
σc 1
F= = = 34.5
σt 0.028986207

El factor de seguridad es mayor a 2, por lo tanto nuestra estructura cumple con el


parámetro que presión de la estructura sobre el terreno.

Caso II: La poza de disipación se encuentra con agua y el nivel freático por debajo de la
cimentación

-La fuerza resultante que genera la presión neutra del terreno es:

𝜆𝑛 × 𝛾𝑠 × ℎ2
𝑃𝑆 =
2

- La que genera la presión del agua es:

𝛾𝑎 × ℎ2
𝑃𝑎 =
2

Dado que este caso se encuentra agua en la poza y esta ejerce una fuerza contraria a la
fuerza ejercida por el suelo y debido a la sobre carga que se ejercer, entonces:

ℎ × 𝑃𝑎 ℎ × 𝑃𝑠 600 × ℎ
𝑀𝐴 = − −( )
3 3 2

Se puede ver que en este caso la magnitud del momento en el punto B depende de las
características del suelo y de la compactación del mismo por debajo de la losa (soporte
elástico o no elástico). Dado que si hay un soporte elástico produce un momento más
grande, para el cálculo del momento se opto realizar de la siguiente forma:

𝑞 × 𝑏2
𝑀𝐵 = −𝑀𝐴 +
8

Donde: 𝑞 = 𝛾𝑎 × ℎ

Seguridad contra la sub-presión

El terreno está seco en el caso II, la napa freática se encuentra ubicada a una profundidad
por debajo de la loza de la poza y debido a esto ya no es necesario realizar el cálculo por
la seguridad contra la sub-presión.

Presión de la estructura sobre el terreno

21
Para calcular la presión, se tiene que considerar las siguientes fuerzas.

𝑃1 = (𝑏 + 2𝑑1 + 2𝑋) × 𝑑2 × 𝛾𝑐

𝑃2 = 𝑑1 × ℎ × 𝛾𝐶

𝑃3 = 𝛾𝑆 × ℎ × 𝑋

𝑄 = 𝛾𝑎 × ℎ × 𝑏
𝑃1 +2𝑃2 +2𝑃3 +𝑄
Entonces: 𝜎𝑡 = (𝑏+2𝑑1 +2𝑋)

𝜎
Y el factor de seguridad: F=𝜎𝑐 >= 2.00
𝑡

Caso II
Fuerza resultante que genera Momento en el punto A
la presion neutra del terreno Ma -748.330052 kg.m
PS 2455.43147 kg/m q 2150 kg.m
La fuerza que genera
la presion del agua Momento en el punto B
Pa 2311.25 kg/m Mb 1823.330052 kg.m

Presion de la estructura Factor de


sobre el terreno seguridad
P1 1392 kg/m 5.677591135
P2 1290 kg/m
P3 971.8 kg/m

LA SUPRESION Q
Q 4300 kg/m

PRESION DE LA ESTRUCTURA
SOBRE EL TERRENO

0.352262069 kg/cm
CAPACIDAD PORTANTE DEL
TERRENO

seco 2 kg/cm2

22
5 . Diseño de acero de refuerzo y control de agrietamiento.

Caso I

𝑀𝐴 = 370281,4309 𝑘𝑔. 𝑐𝑚

𝑀𝑈𝐴 = 1.8 × (370281,4309) = 666506,5756 𝑘𝑔. 𝑐𝑚

Calculo del valor de “a”

1.27
𝑑 = 25 − 4 − ( ) = 20.365 𝑐𝑚
2
𝑎
666506,5756 = 0.9 × (𝑎 × 0.85 × 280 × 200) × (20.365 − )
2
𝑎
15.55804332 = 𝑎 × (20.365 − )
2

31.11608663 = 40.73𝑎 − 𝑎2

0 = 𝑎2 − 40.73𝑎 + 31.11608663

𝑎 = 0.7788534068 𝑐𝑚

666506,5756
𝐴𝑆 = 0.7788534068
= 8.827005277𝑐𝑚2
0.9 × 4200 × (20.365 − 2
)

-Cálculo de área de acero mínimo

𝑀𝐴 = 370281,4309 𝑘𝑔. 𝑐𝑚

𝑀𝑈𝐴 = 1.8 × (370281,4309) = 666506,5756 𝑘𝑔. 𝑐𝑚

23
𝑓𝑐 ′ 6000
𝑃𝑏 = 0.72 × × = 0.0028352941176
𝑓𝑦 6000 + 𝑓𝑦

𝑃𝑏𝑚𝑎𝑥 = 0.0211764705882

√𝑓𝑐 ′
𝑃𝑏𝑚í𝑛 = 0.7 × = 0.002788866755
𝑓𝑦

𝑃𝑏𝑚𝑖𝑛 × 𝑏 × 𝑑 = 𝐴𝑆𝑚𝑖𝑛

𝐴𝑆𝑚𝑖𝑛 = 11.35905429𝑐𝑚2 /𝑚

Caso II

𝑀𝐴 = 74833.0052 𝑘𝑔. 𝑐𝑚

𝑀𝑈𝐴 = 1.8 × (74833.0052) = 134699.4094 𝑘𝑔. 𝑐𝑚

Calculo del valor “a”

𝑎
134699.4094 = 0.9 × (𝑎 × 0.85 × 280 × 200) × (20.365 − )
2
𝑎
3.1442243917 = 𝑎 × (20.365 − )
2

6.288487834 = 40.73𝑎 − 𝑎2

0 = 𝑎2 − 40.73𝑎 + 6.288487834

𝑎 = 0.1549842364 𝑐𝑚

134699.4094
𝐴𝑆 = 0.1549842364
= 1.756488012𝑐𝑚2
0.9 × 4200 × (20.365 − 2
)

24
Refuerzo por temperatura

𝐴 𝑇𝑒𝑚𝑝 = 0.0025 × 𝑏 × 𝑑 𝑇

b= ancho de la poza (cm)

𝑑 𝑇 = peralte total del elemento (cm)

0.0025 = (cuantía para losas donde se usan barras lisas)

𝑐𝑚2
𝐴 𝑇𝑒𝑚𝑝 = 0.0025 × 200 × 25 = 12.5
𝑚

- Calculo de refuerzo del piso de la poza

Adoptar para el recubrimiento (C) en la cara superior 0.04 m, y en la cara


inferior 0.075 m. Adoptar para el diámetro de la barra ½”, o sea 0.0127 m.

Momento último en el punto B para el caso I

𝑀𝑈𝑏 = 1.8 × (𝑀𝑏 ) = 1.8 × 259539.243

𝑀𝑈𝑏 = 467170.6374 𝑘𝑔. 𝑐𝑚

1.27
𝑑 = 25 − 7.5 − ( ) = 16.865 𝑐𝑚
2

𝑏 = 200 𝑐𝑚

Calculo de “a”

𝑎
467170.6374 = 0.9 × (0.85 × 280 × 200 × 𝑎) × (16.865 − )
2

25
𝑎
10.90501021 = 𝑎 × (16.865 − )
2

0 = 𝑎2 − 33.73𝑎 + 21.81002042

𝑎 = 0.659500792 𝑐𝑚

467170.6374
𝐴𝑆 = 0.659500792
= 7.47434231𝑐𝑚2
0.9 × 4200 × (16.865 − 2
)

Calculo del refuerzo del piso de la poza

b=200cm d=16.865cm

𝑃𝑏𝑚𝑖𝑛 = 0.002788866755

𝐴𝑆𝑚𝑖𝑛 = 𝑃𝑏𝑚𝑖𝑛 × 𝑏 × 𝑑 = 9.406847565𝑐𝑚2

Momento último en el punto A del piso para el caso I es igual momento


último en la pared en mismo punto. (Cara inferior de la losa).

d=16.865 cm

𝑀𝑈𝐴 = 1.8 × 𝑀𝐴

𝑀𝐴 = 370281.4309 𝑘𝑔. 𝑐𝑚

𝑀𝑈𝐴 = 666506.5756 𝑘𝑔. 𝑐𝑚

𝑎 = 0.7788534068 𝑐𝑚

𝑀𝑈𝐴
𝑎= 𝑎
𝜙 × (𝑑 − 2) × 0.85 × 𝑓𝑐 ′ × 𝑏

Hallando el nuevo valor de “a”

26
𝑎
666506.5756 = 0.9 × (0.85 × 280 × 200) × 𝑎 × (16.865 − )
2

31.11608663 = 33.73𝑎 − 𝑎2

0 = 𝑎2 − 33.73𝑎 + 31.11608663

𝑎 = 0.9492173183 𝑐𝑚

666506.5756
𝐴𝑆 = 0.9492173183
= 10.75779627𝑐𝑚2
0.9 × 4200 × (16.865 − 2
)

* Momento último en el punto A del piso para el caso II (cara superior de


losa).

𝑀𝑈𝐴 = 1.8 × 𝑀𝐴

𝑀𝐴 = 74833.0052 𝑘𝑔. 𝑐𝑚

𝑀𝑈𝐴 = 134699.4094 𝑘𝑔. 𝑐𝑚

Habrá que cambiar el valor d, porque se trata ahora de la cara superior de la


losa

1.27
𝑑 = 25 − 4 − ( ) = 20.365
2

Calculo de “a”

𝑎
134699.4094 = 0.9 × 0.85 × 280 × 200 × 𝑎 × (20.365 − )
2

6.288487832 = 40.73𝑎 − 𝑎2

0 = 𝑎2 − 40.73𝑎 + 6.288487832

27
𝑎 = 0.1549842363

134699.4094
𝐴𝑆 = 0.1549842363
0.9 × 4200 × (20.365 − 2
)

𝐴𝑆 = 1.756488012 𝑐𝑚2

Y la cantidad de refuerzo 𝐴𝑆 será 1.756488012 𝑐𝑚2 porque es igual al valor


correspondiente, calculado para la pared, para el mismo caso.

Por lo tanto la cantidad mínima de refuerzo resulta sin embargo mayor


𝐴𝑆𝑚𝑖𝑛 = 11.35905397𝑐𝑚2 .

Cantidad mínima de refuerzo

b=200cm d=20.365cm

𝑃𝑏𝑚𝑖𝑛 = 0.002788866755

𝐴𝑆𝑚𝑖𝑛 = 𝑃𝑏𝑚𝑖𝑛 × 𝑏 × 𝑑 = 11.35905397𝑐𝑚2

Refuerzo por contracción y temperatura en el piso

𝐴 𝑇𝑒𝑚 = 0.0018 × 𝑏 × 𝑑 𝑇

b= ancho del elemento (cm)

𝑑 𝑇 = Peralte total del elemento (cm)

0.0018= (cuantía para el área de acero por temperatura mínimo en losas)

𝐴 𝑇𝑒𝑚 = 0.0018 × 200 × 25 = 9𝑐𝑚2 /𝑚

28
Calculo de la fuerza cortante

𝑉 = 𝑃𝑆1 + 𝑃𝑆2 + 𝑃𝑆3 + 𝑃𝑎 + 𝑃𝑆𝑂𝐵𝑅𝐸𝐶𝐴𝑅𝐺𝐴

𝑉 = 191.2288 + 988.0156905 + 903.4951741 + 1201.25 + 1290

𝑉 = 4573.989708 𝑘𝑔/𝑚

𝑉𝑈 = 1.8 × 𝑉 = 1.8 × (4573.989708) = 8233.181474 𝑘𝑔/𝑚

𝑉𝑈 8233.181474
𝜏𝑈 = = = 2.021404732 𝑘𝑔/𝑐𝑚2
𝑏 × 𝑑 200 × 20.365

La fuerza admisible en el concreto es:

𝜎𝑎𝑑𝑚 = 0.5 × √280 = 8.366600265 𝑘𝑔/𝑐𝑚2

𝜎𝑈 < 𝜎𝑎𝑑𝑚

Resumen del cálculo

𝐴𝑆 = 8.827005277𝑐𝑚2
Cara exterior - vertical
Paredes Horizontal 𝐴 𝑇𝑒𝑚𝑝 = 12.5𝑐𝑚2 /𝑚
𝐴𝑆𝑚𝑖𝑛 = 11.35905429𝑐𝑚2 /𝑚
Cara interior- vertical
Horizontal 𝐴 𝑇𝑒𝑚𝑝 = 12.5𝑐𝑚2 /𝑚
𝐴𝑆𝑚𝑖𝑛 = 11.35905429𝑐𝑚2 /𝑚
Cara superior-perp-eje
Piso Par.eje 𝐴 𝑇𝑒𝑚𝑝 = 9𝑐𝑚2 /𝑚
𝐴𝑆 = 10.75779627 𝑐𝑚2 /𝑚

29
Cara inferior- pero-eje 𝐴 𝑇𝑒𝑚𝑝 = 9𝑐𝑚2 /𝑚

Control de agrietamiento

3
𝑊𝑐𝑟 = 1.1 × 𝑅 × 𝑓𝑠 × 10−5 × √𝐴 × 𝑑𝑐

Donde:

A: Área de concreto en tracción que rodea la varilla.

2 × 𝑑𝑐 × 𝑏
𝐴= 𝑒𝑛 1 𝑐𝑎𝑝𝑎 𝑑𝑒 𝑎𝑐𝑒𝑟𝑜 𝑒𝑛 𝑙𝑎 𝑠𝑒𝑐𝑐𝑖𝑜𝑛 𝑑𝑒 𝑙𝑎 𝑙𝑜𝑠𝑎
𝑁

N: Número de varillas en tracción (será la cantidad de varillas si todas son del


mismo diámetro, o el área total del acero dividido entre el área de la varilla
mas grande, si se usa más de un tamaño)

Dc= Distancia de la cara exterior al centroide de la 1° capa de refuerzo

En general dc=7cm

𝜔 = 𝑎𝑛𝑐ℎ𝑜 𝑑𝑒 𝑔𝑟𝑖𝑒𝑡𝑎 (𝑚𝑚)

ℎ − 𝑐 𝑒𝑛 𝑣𝑖𝑔𝑎𝑠 1.2
𝑅= {
𝑑 − 𝑐 𝑒𝑛 𝑙𝑜𝑠𝑎𝑠 1.35

𝑀(𝑠𝑒𝑟𝑣𝑖𝑐𝑖𝑜) 𝑀(𝑠𝑒𝑟𝑣𝑖𝑐𝑖𝑜)
𝑓𝑠 = ≅
𝐴𝑆 × 𝑗 × 𝑑 𝐴𝑆 × 0.9 × 𝑑

𝑓𝑠 = 𝑒𝑠𝑓𝑢𝑒𝑟𝑧𝑜 𝑑𝑒𝑙 𝑎𝑐𝑒𝑟𝑜 𝑐𝑜𝑛 𝑐𝑎𝑟𝑔𝑎 𝑑𝑒 𝑠𝑒𝑟𝑣𝑖𝑐𝑖𝑜

El espaciamiento de las barras de acero de ½” es:

30
100 × 𝐴(𝜙)
𝑆=
𝐴𝑆

100 × 1.267
𝑆= = 14.35367897
8.827005277

𝐴𝑒
𝐴=
𝑁

2.15
𝑁= = 149.7873824
0.01435367897

2 × 𝑑𝑐 × 𝑏 2 × 7 × 200
𝐴= = = 18.69316331𝑐𝑚2
𝑁 149.7873824
3
𝑊𝑐𝑟 = 1.1 × 1.35 × 4119.686121 × 10−5 × √18.69316331 × 7

𝑾𝒄𝒓 = 𝟎. 𝟏𝟎𝟓𝟏𝟒𝟒𝟗𝟓𝟖𝟑 𝒎𝒎

El agrietamiento es de 0.1 mm está dentro de los parámetros esperados.

6. INCREMENTO DINÁMICO DE PRESIÓN POR EL EFECTO SÍSMICO

Los efectos dinámicos producidos por los sismos se simularán mediante empujes de tierra debidos a
las fuerzas de inercia de las masas del muro y del relleno. Las fuerzas de inercia se determinarán
teniendo en cuenta la masa de tierra apoyada directamente sobre la cara interior y zapata del muro
con adición de las masas propias de la estructura de retención.
El empuje sísmico generado por el relleno depende del nivel de desplazamiento que experimente el
muro. Se considerará un estado activo de presión de tierras cuando el desplazamiento resultante
permita el desarrollo de la resistencia al corte del relleno. Si el desplazamiento de la corona del muro
esta restringido, el empuje sísmico se calculará con la condición de tierras en reposo. El estado pasivo
de presión de tierras solo puede generarse cuando el muro tenga tendencia a moverse hacia el
relleno y el desplazamiento sea importante.

Incremento Dinámico del Empuje Pasivo

31
El empuje pasivo se incrementa cuando ocurre un sismo, este aumento de presión se denomina
incremento dinámico del empuje pasivo ΔDEp, la resultante de este incremento de empuje se aplica
a un tercio de la altura de relleno en condición pasiva, medida desde la base del muro.

EMPUJE PASIVO ( Ep )

Kp es el coeficiente de presión pasiva.


La presión pasiva en suelos granulares, se puede determinar con las siguientes expresiones:
1. El coeficiente Kp adecuando la ecuación de Coulomb es:

32
Solución

φ = 32

Kp= 3.254588303

H= 2.35

Ys= 2260

Ep= 20310.01421

Ys= 2260 Ysat=1600


Ep= 20310.01421 Ep = 14378.77112
Incremento Dinámico del Empuje Pasivo
El incremento dinámico del empuje pasivo ΔDEp se aplicará a 1/3 H desde la base
del muro y se determinará con la expresión A0 es la aceleración del suelo según el
mapa de zonificación sísmica de cada país, en Perú los valores de A0 son los
indicados por la norma LA NORMA TÉCNICA E.030 “DISEÑO
SISMORRESISTENTE” DEL REGLAMENTO NACIONAL DE EDIFICACIONES,
capitulo 2 “peligro sísmico”

33
Nuestro diseño de caida inclinada esta la provincia de trujillo, departamento de la
libertad ubicada en la costa norte del pais, entonces como podemos apreciar la
imagen de referencia se ubica en la zona 4 la aceleración del suelo según el mapa
de zonificación sísmica es de alto indice sismico. Su valor es A0 =0.45.

A cada zona se asigna un factor Z


según se indica en la Tabla N° 1. Este
factor se interpreta como la aceleración
máxima horizontal en suelo rígido con
una probabilidad de 10 % de ser
excedida en 50 años. El factor Z se
expresa como una fracción de la
aceleración de la gravedad.

Zona 4 →Z =0.45 = Ao

Ao = 0.45

Coeficiente sísmico horizontal

Csh = 0,50⋅Ao

Csh = 0.225

Coeficiente sísmico vertical

Csv=0,70⋅Csh

Csv= 0.1575

34
𝜽= 14.95257905

Otros datos

φ = 32
β=0
Ψ=90
δ= 2/3 φ= 21.33
Kps es el coeficiente de presión dinámica pasiva.

Kps= 5.549615485

CASO 1 CASO 2
∆DEp=12066.23866 ∆DEp=8542.469851

VARIACIÓN DE FUERZA CON INCREMENTE SÍSMICO

Diseño de acero de refuerzo y control de agrietamiento.

35
Caso I

𝑀𝐴 = 1315470,12595202 𝑘𝑔. 𝑐𝑚

𝑀𝑈𝐴 = 1.8 × (1315470,12595202) = 2367846.227𝑘𝑔. 𝑐𝑚

Calculo del valor de “a”

1.27
𝑑 = 25 − 4 − ( ) = 20.365 𝑐𝑚
2
𝑎
236784.6227 = 0.9 × (𝑎 × 0.85 × 280 × 200) × (20.365 − )
2
𝑎
55.27185403 = 𝑎 × (20.365 − )
2

110.5437081 = 40.73𝑎 − 𝑎2

0 = 𝑎2 − 40.73𝑎 + 110.5437081

𝑎 = 2.923970303𝑐𝑚

2367846.227
𝐴𝑆 = 2.923970303
= 33.13833009𝑐𝑚2
0.9 × 4200 × (20.365 − )
2

-Cálculo de área de acero mínimo

𝑀𝐴 = 1315470,12595202 𝑘𝑔. 𝑐𝑚

𝑀𝑈𝐴 = 1.8 × (370281,4309) = 2367846.227 𝑘𝑔. 𝑐𝑚

𝑓𝑐 ′ 6000
𝑃𝑏 = 0.72 × × = 0.0028352941176
𝑓𝑦 6000 + 𝑓𝑦

36
𝑃𝑏𝑚𝑎𝑥 = 0.0211764705882

√𝑓𝑐 ′
𝑃𝑏𝑚í𝑛 = 0.7 × = 0.002788866755
𝑓𝑦

𝑃𝑏𝑚𝑖𝑛 × 𝑏 × 𝑑 = 𝐴𝑆𝑚𝑖𝑛

𝐴𝑆𝑚𝑖𝑛 = 11.35905429𝑐𝑚2 /𝑚

Caso II

𝑀𝐴 = 966938.320447874𝑘𝑔. 𝑐𝑚

𝑀𝑈𝐴 = 1.8 × (966938.320447874) = 1740488.977 𝑘𝑔. 𝑐𝑚

Calculo del valor “a”

𝑎
1740488.977 = 0.9 × (𝑎 × 0.85 × 280 × 200) × (20.365 − )
2
𝑎
40.62766052 = 𝑎 × (20.365 − )
2

81.25532105 = 40.73𝑎 − 𝑎2

0 = 𝑎2 − 40.73𝑎 + 81.25532105

𝑎 = 2.103622616𝑐𝑚

1740488.977
𝐴𝑆 = 2.103622616
= 23.84105632𝑐𝑚2
0.9 × 4200 × (20.365 − 2
)

Refuerzo por temperatura

37
𝐴 𝑇𝑒𝑚𝑝 = 0.0025 × 𝑏 × 𝑑 𝑇

b= ancho de la poza (cm)

𝑑 𝑇 = peralte total del elemento (cm)

0.0025 = (cuantía para losas donde se usan barras lisas)

𝑐𝑚2
𝐴 𝑇𝑒𝑚𝑝 = 0.0025 × 200 × 25 = 12.5
𝑚

- Calculo de refuerzo del piso de la poza

Adoptar para el recubrimiento (C) en la cara superior 0.04 m, y en la cara


inferior 0.075 m. Adoptar para el diámetro de la barra ½”, o sea 0.0127 m.

Momento último en el punto B para el caso I

𝑀𝑈𝑏 = 1.8 × (𝑀𝑏 ) = 1.8 × 1204727.93845202

𝑀𝑈𝑏 = 2168510.289 𝑘𝑔. 𝑐𝑚

1.27
𝑑 = 25 − 7.5 − ( ) = 16.865 𝑐𝑚
2

𝑏 = 200 𝑐𝑚

Calculo de “a”

𝑎
2168510.289 = 0.9 × (0.85 × 280 × 200 × 𝑎) × (16.865 − )
2
𝑎
50.61882094 = 𝑎 × (16.865 − )
2

0 = 𝑎2 − 33.73𝑎 + 101.2376419

38
𝑎 = 3.330208421𝑐𝑚

2168510.289
𝐴𝑆 = 3.330208421
= 37.74236209𝑐𝑚2
0.9 × 4200 × (16.865 − 2
)

Calculo del refuerzo del piso de la poza

b=200cm d=16.865cm

𝑃𝑏𝑚𝑖𝑛 = 0.002788866755

𝐴𝑆𝑚𝑖𝑛 = 𝑃𝑏𝑚𝑖𝑛 × 𝑏 × 𝑑 = 9.406847565𝑐𝑚2

Momento último en el punto A del piso para el caso I es igual momento


último en la pared en mismo punto. (Cara inferior de la losa).

d=16.865 cm

𝑀𝑈𝐴 = 1.8 × 𝑀𝐴

𝑀𝐴 = 1315470,12595202 𝑘𝑔. 𝑐𝑚

𝑀𝑈𝐴 = 2367846.227 𝑘𝑔. 𝑐𝑚

𝑎 = 2.923970303 𝑐𝑚

𝑀𝑈𝐴
𝑎= 𝑎
𝜙 × (𝑑 − 2) × 0.85 × 𝑓𝑐 ′ × 𝑏

Hallando el nuevo valor de “a”

𝑎
2367846.227 = 0.9 × (0.85 × 280 × 200) × 𝑎 × (16.865 − )
2

110.5437081 = 33.73𝑎 − 𝑎2

39
0 = 𝑎2 − 33.73𝑎 + 110.5437081

𝑎 = 3.678472144𝑐𝑚

2367846.227
𝐴𝑆 = 3.678472144
= 41.68935096𝑐𝑚2
0.9 × 4200 × (16.865 − 2
)

* Momento último en el punto A del piso para el caso II (cara superior de


losa).

𝑀𝑈𝐴 = 1.8 × 𝑀𝐴

𝑀𝐴 = 966938.320447874𝑘𝑔 𝑘𝑔. 𝑐𝑚

𝑀𝑈𝐴 = 1740488.977 𝑘𝑔. 𝑐𝑚

Habrá que cambiar el valor d, porque se trata ahora de la cara superior de la


losa

1.27
𝑑 = 25 − 4 − ( ) = 20.365
2

Calculo de “a”

𝑎
1740488.977 = 0.9 × 0.85 × 280 × 200 × 𝑎 × (20.365 − )
2

81.25532106 = 40.73𝑎 − 𝑎2

0 = 𝑎2 − 40.73𝑎 + 81.25532106

𝑎 = 2.103622617

1740488.977
𝐴𝑆 = 2.103622617
0.9 × 4200 × (20.365 − 2
)

40
𝐴𝑆 = 23.84105632𝑐𝑚2

Y la cantidad de refuerzo 𝐴𝑆 será 23.84105632 𝑐𝑚2 porque es igual al valor


correspondiente, calculado para la pared, para el mismo caso.

Por lo tanto la cantidad mínima de refuerzo resulta sin embargo mayor


𝐴𝑆𝑚𝑖𝑛 = 11.35905397𝑐𝑚2 .

Cantidad mínima de refuerzo

b=200cm d=20.365cm

𝑃𝑏𝑚𝑖𝑛 = 0.002788866755

𝐴𝑆𝑚𝑖𝑛 = 𝑃𝑏𝑚𝑖𝑛 × 𝑏 × 𝑑 = 11.35905397𝑐𝑚2

Refuerzo por contracción y temperatura en el piso

𝐴 𝑇𝑒𝑚 = 0.0018 × 𝑏 × 𝑑 𝑇

b= ancho del elemento (cm)

𝑑 𝑇 = Peralte total del elemento (cm)

0.0018= (cuantía para el área de acero por temperatura mínimo en losas)

𝐴 𝑇𝑒𝑚 = 0.0018 × 200 × 25 = 9𝑐𝑚2 /𝑚

Espaciamiento del Acero Principal

𝐴(∅) ∗ 100 1.27 ∗ 100


𝑆𝑐 = = = 4𝑐𝑚
𝐴𝑠 33.13833009

41
𝐴(∅) ∗ 100 1.27 ∗ 100
𝑆𝑐 = = = 10.16 𝑐𝑚
𝐴𝑠 12.5

𝐴(∅) ∗ 100 1.27 ∗ 100


𝑆𝑐 = = = 11.37𝑐𝑚
𝐴𝑠 11.36

𝐴(∅) ∗ 100 1.27 ∗ 100


𝑆𝑐 = = = 14.3𝑐𝑚
𝐴𝑠 9

𝐴(∅) ∗ 100 1.27 ∗ 100


𝑆𝑐 = = = 3.5𝑐𝑚
𝐴𝑠 41.68935096

Calculo de la fuerza cortante

𝑉 = 𝑃𝑆1 + 𝑃𝑆2 + 𝑃𝑆3 + 𝑃𝑎 + 𝑃𝑆𝑂𝐵𝑅𝐸𝐶𝐴𝑅𝐺𝐴


+ 𝑖𝑛𝑐𝑟𝑒𝑚𝑒𝑛𝑡𝑜 𝑑𝑒 𝑙𝑎 𝑓𝑢𝑒𝑟𝑧𝑎 𝑝𝑜𝑟 𝑎𝑛𝑎𝑙𝑖𝑠𝑖𝑠 𝑠𝑖𝑠𝑚𝑖𝑐𝑜

𝑉 = 191.2288 + 988.0156905 + 903.4951741 + 1201.25 + 1290


+ 12066.23866

𝑉 = 16640.22837 𝑘𝑔/𝑚

𝑉𝑈 = 1.8 × 𝑉 = 1.8 × (16640.22837) = 29952.41106𝑘𝑔/𝑚

𝑉𝑈 29952.41106
𝜎𝑈 = = = 7.353894197𝑘𝑔/𝑐𝑚2
𝑏 × 𝑑 200 × 20.365

La fuerza admisible en el concreto es:

𝜎𝑎𝑑𝑚 = 0.5 × √280 = 8.366600265 𝑘𝑔/𝑐𝑚2

𝜎𝑈 < 𝜎𝑎𝑑𝑚

Resumen del cálculo

42
𝐴𝑆 = 33.13833009𝑐𝑚2
Cara exterior - vertical
Paredes Horizontal 𝐴 𝑇𝑒𝑚𝑝 = 12.5𝑐𝑚2 /𝑚
𝐴𝑆𝑚𝑖𝑛 = 11.36 𝑐𝑚2 /𝑚
Cara interior- vertical
Horizontal 𝐴 𝑇𝑒𝑚𝑝 = 12.5𝑐𝑚2 /𝑚
Cara superior-perp- 𝐴𝑆𝑚𝑖𝑛 = 11.35905429𝑐𝑚2 /𝑚
Piso eje 𝐴 𝑇𝑒𝑚𝑝 = 9 𝑐𝑚2 /𝑚
Cara inferior- pero- 𝐴𝑆 = 41.68935096 𝑐𝑚2 /𝑚
eje 𝐴 𝑇𝑒𝑚𝑝 = 9𝑐𝑚2 /𝑚
Cantidad de fierros

Cara exterior - ؽ” @ 4 cm


Paredes vertical Horizontal (ؽ” @ 10 cm) x m
ؽ” @ 10 cm
Cara interior- vertical
Horizontal (ؽ” @ 10 cm) x m
ؽ” @ 10 cm
Cara superior-perp-eje
Piso ؽ” @ 12.5 cm
ؽ” @ 3.5 cm
Cara inferior- pero-eje
ؽ” @ 12.5 cm

Control de agrietamiento

3
𝑊𝑐𝑟 = 1.1 × 𝑅 × 𝑓𝑠 × 10−5 × √𝐴 × 𝑑𝑐

Donde:

A: Área de concreto en tracción que rodea la varilla.

2 × 𝑑𝑐 × 𝑏
𝐴= 𝑒𝑛 1 𝑐𝑎𝑝𝑎 𝑑𝑒 𝑎𝑐𝑒𝑟𝑜 𝑒𝑛 𝑙𝑎 𝑠𝑒𝑐𝑐𝑖𝑜𝑛 𝑑𝑒 𝑙𝑎 𝑙𝑜𝑠𝑎
𝑁

43
N: Número de varillas en tracción (será la cantidad de varillas si todas son del
mismo diámetro, o el área total del acero dividido entre el área de la varilla
mas grande, si se usa más de un tamaño)

Dc= Distancia de la cara exterior al centroide de la 1° capa de refuerzo

En general dc=7cm

𝜔 = 𝑎𝑛𝑐ℎ𝑜 𝑑𝑒 𝑔𝑟𝑖𝑒𝑡𝑎 (𝑚𝑚)

ℎ − 𝑐 𝑒𝑛 𝑣𝑖𝑔𝑎𝑠 1.2
𝑅= {
𝑑 − 𝑐 𝑒𝑛 𝑙𝑜𝑠𝑎𝑠 1.35

𝑀(𝑠𝑒𝑟𝑣𝑖𝑐𝑖𝑜) 𝑀(𝑠𝑒𝑟𝑣𝑖𝑐𝑖𝑜)
𝑓𝑠 = ≅
𝐴𝑆 × 𝑗 × 𝑑 𝐴𝑆 × 0.9 × 𝑑

𝑓𝑠 = 𝑒𝑠𝑓𝑢𝑒𝑟𝑧𝑜 𝑑𝑒𝑙 𝑎𝑐𝑒𝑟𝑜 𝑐𝑜𝑛 𝑐𝑎𝑟𝑔𝑎 𝑑𝑒 𝑠𝑒𝑟𝑣𝑖𝑐𝑖𝑜

El espaciamiento de las barras de acero de ½” es:

100 × 𝐴(𝜙)
𝑆=
𝐴𝑆

100 × 1.267
𝑆= =4
33.13833009

𝐴𝑒
𝐴=
𝑁

2.15
𝑁= = 430
0.004

2 × 𝑑𝑐 × 𝑏 2 × 7 × 200
𝐴= = = 6.511627907𝑧𝑐𝑚2
𝑁 430
3
𝑊𝑐𝑟 = 1.1 × 1.35 × 3898.485753 × 10−5 × √18.69316331 × 7

44
𝑾𝒄𝒓 = 𝟎. 𝟐𝟎𝟔𝟖𝟎𝟎𝟓𝟏𝟐𝟑 𝒎𝒎

El agrietamiento es de 0.1 mm está dentro de los parámetros esperados.

45

You might also like