Professional Documents
Culture Documents
N AL
E CA
G d STORM
roa WATER
NA
AL-2
DRAINA
AI a lt GE CAN
R ph AL-2
D As
GE CAN
R AL
E OS
OP
AT PR
ST
W
OR
ad
DRAINA
RM ro
M
O l t
ST ha
W
sp
AT
L A
SA
WATER
R
PO
DR
O
PR 27.697
AI
26.98
d
roa PROPO 24.916
NA
SAL Asp
STORM
alt 28.264
halt ro
ad
GE
ph
23.42
As
21.398
L
SA
CA
O29.571
OP
NA
PR
0.25%
20.017
ad
27.909
halt ro
L-3
20.092
SAL Asp
18.53 19.524
PROPO
30.219 18.899
20.38
18.321
31.252
PROPOSAL Asphalt
30.314
22.294
-2
25.827
-2 AL
ad AL
30.608
30.608
N
AN
ST
ANAL-2
ro
CA
22.972
OR
lt
a
EC E
M
ph
30.879
AG
30.879
As
W
25.13
AG
road
AT
L
SA IN IN
ER
A
C
PO
RA DR
DR
O
INAGE
PR D R
AI
ER E
31.899
NA
AT AT
31.899
GE
W W
CA
RM
TER DRA
RM
NA
24.286 25.969
O
L-
ST
O ad ST
1
ro
t
h al
33.474
33.474
sp 26.347
RM WA
LA
SA
PO
O
PR
34.635
34.635
STO
24.688
36.171
36.171
37.036
37.036
37.131
37.691
23.228
37.287
38.927
39.876
39.973
39.521
ST
OR
PRO
M
39.885
POSA
W
L Asp
ad
AT
halt r
40.373
ro
ER
oad l t
ha
41.144
DR
p
23.98
As
AI
L
NA
SA
42.633
PO
GE
43.653
O
PR
CA
NA
L-
45.295
2
45.871
46.809
47.872
GE CANAL-2
26.074 STORM WATER DRAINA
49.064
26.658
28.88
ad
halt ro
32.986 30.27
L Asp
36.536
PROPOSA
38.304
L -2
NA
38.359
STO CA
RM G E 36.657
WAT
ER D INA
RAI
NAG D RA 34.957
E CA road
NAL ER lt
-2 AT L As
pha
33.837
W PO SA
RM PRO
S TO
34.342
PRO
PO
SAL
Asp
ST
OR
ha
M
lt
W
roa
AT
ER
d
DR
AI
NA
GE
CA
N AL
-2
5/5/37
PROPO
SAL Asp
halt ro
ad
1.6m
1. 1. 1.
2m 2m R52.5m 2m 2m 2m
1. 1.
0.8m
0.8m
0.8m
0.8m
0.8m
R1.0m R1.0m R1.0m
R1.0m
R1.0m
4.0m
4.0m
1.0m
1.0m
2.5m
0.4m
1.
1.
4m
4m
4m
4m
4m
1.
1.
1.
3.0m
1.4m
1.7m
2.5m
2.5m
R0.7m
1.7m
1.7m
1.7m
1.7m
1.7m
R0.7m R0.7m R0.7m
R0.7m
0.8m
0.8m
0.6m
0.6m
0.6m
0.6m
0.6m
0.3m 0.3m 0.3m 0.3m 0.3m 0.3m
A1 STRAIGHT ARROW A2 COMBINED STRAIGHT/RIGHT ARROW A3 COMBINED STRAIGHT/LEFT ARROW A4 RIGHT TURN ARROW A5 LEFT TURN ARROW A6 LEFT/RIGHT ARROW
--- --- --- --- --- ---
Tiles
Sand Setting Bed 5 cm
Raised Kerb Type ( A2 )
Plain Concrete 10 cm
50cm x30cm x15cm Edge Kerb Type ( B )
Drop Kerb Type ( D ) Granular Base course 10 cm 50cm x 30cm x 10cm
50cm x 30cm x 22 cm Raised Kerb Type ( A1 ) Tiles
Compacted Sub Grade 20 cm Cement Morter Edge Type ( C )
50cm x 30cm x 15cm 40cm x 40cm x 4cm
3 cm Thick. Tiles 50cm x 20cm x 10cm Tiles
40cm x 40cm x 4cm 40cm x 40cm x 4cm
Asphalt Ground Surface
Tiles
Sand Setting Bed 5 cm
Plain Concrete
Plain Concrete
10 cm Thick. Plain Concrete 10 cm Cement Morter
10 cm Thick. Plain Concrete 3 cm Thick.
Cement Morter Compacted Sub Grade 20 cm Plain Concrete Planting Soil Cement Morter
Cement Morter 10 cm Thick. Plain Concrete
3 cm Thick. 10cm Thick. Mixture 3 cm Thick.
3cm Thick. 10 cm Thick.
BITUMINOUS WEARING COURSE = 50mm Flush Kerb / Edge Kerb Type ( C )
BITUMINOUS BASE COURSE = 80mm This Type of Kerb is Used as Sidewalk Protection
Raised Kerb Type ( A1 ) Edge Kerb Type ( B ) at Empty Areas & at Pedestrian Crossing for Boundary.
AGGREGATE BASE COURSE Detail Detail
300 mm CBR > 80% Typical Sidewalk & Raised Parking Area Section
SUBGRADE MIN 300 mm C.B.R > 25%
TRASH BIN
Plain Concrete
Cement Mortar 10 cm Thick.
Cement Morter Plain Concrete
LONGITUDINAL JOINTS DETAIL BETWEEN EXISTING AND NEW PAVEMET 3cm Thick.
3 cm Thick.
10cm Thick. Drop Kerb Type ( D )
DETAIL TRASH BIN
Raised Kerb Type ( A2 ) Detail
SCALE : NTS.
Detail
150
SIDEWALK CURB
2.1
5.50
0
50
2.
3.00
R0.
50
.50
5
0.7
R0
0
1.5
5
0.7
DROP CURB EDGE MARKING
ASPHALTIC CONCRETE
WEARING COURSE
A
1.8
6.00
2.50
.60
0.1
310
STREET NAME
STOP
STOP
2320
76 Ø I.D.GALVANIZED
STEEL PIPE
20 THK.
PLATE
1
6
DIRECTION OF
6Ø x 6Ø LONG 4 REQUIRED
EACH SLIP BASE ASSEMBLY
TRAFFIC
90Ø 4 RAD.
(TYP)
90Ø
TOP OF CONCRETE
FOOTING
150
600
SPECIAL NOTE
1. THIS DESIGN DRAWING IS SUBJECT FOR ANY REVISION TO SUIT THE ACTUAL
SITE CONDITION DURING IMPLEMENTATION WHICH TO BE INCORPORATED
IN THE CONTRACTOR'S SHOP DRAWINGS AND TO BE APPROVED BY HIGHER
MILITARY AUTHORITIES.
178,66
CATCHMEN
CAPACITY=2 ND-1 T PO -2
ND3 3
,63
0000 m3
REFER TO DE O
P m E1
8 TAIL -P1, CE
NT 000 2, C
33
12
H MEITY=8 IL -P
LOOSE STONE T PA DE C C TA
CULVERT-6 CA CA R TO 2487,44
NO R CL E LAN
FE
ORIENTATION
FO R TH
REFER TO DETAIL -6, CE 06 RE
TE ARIT DS
SE
FO
:
E L OO NE
STO
UP
US
RAMP
-2 1. FOR STRUCTURE ORIENTATION, REFER TO THE LATEST SITE PLAN.
Y,
HO ANK 1
CE03
AL
C
RE AP
N M P T 0
FE
PU ATER TO S
A T STORM
C
R T CO
E C03 ND G W REFER CB
3 WATER
O
G U REFER TO DRAINAGE
E
E
TH VER
3
NA , C RO U/ 2 CB SECT. -C CANA
NAL-2
B1 CB , CE 03 L-2
E A AL
AI T. - C EG &
W
1 C
R V CB
RC ON
3
D C BO 1 CB
CB
, CE 03
R O SE
HIT G
REFER TO DRAINAGE CA
T E A 1 1
EC THE
T B 3
A C CB CB
,91
ST
R
FE
TU
CE 05
WE 3
CB
OR
RA CAN
R 3
RM
SECT. -C
1 CB
CB
M R
L D AL
O 6 1
336
3
ST 0 CB 3
-1,
CB
W EFE
W -3
CE CB
R1 3 C
G.
AT R T
, D B1 CB
DETAIL
-7
DR
1 C B2
T-7 AIL
ER O
WATER
1 3 CE03
DR 3 CB
-1
1 CB
1
CB
C CB CB3
ER DET 1
DRSEC
CB CB3
T
3
LV TO
CULVER
CB CB3
27.697
DR
B E02
REFER TO
AI T. -B
26.98
1 CB3
CUEFER
1 3 CB3
CB B 3
CB CB3
1
1 24.916
CB 3
NA , C
C E03
CB
N
1 1 C B CB3 CB3
STORM
CB CB C B3 28.264 C
CB3
C
S
C
R 1
GE E 02
23.42
CB
1 1 1 C CB 3 C CB3 CB3 CB1CB1
CB CE
CA
CB 1 1 CB 29.571 CB3 CB1 CB1 CB1 LOOS
GD GD 1, 3 CB E
-11 IL - B3
1
NA
GD
, CB 3 CB1 CB3
20.017
1 3 CB1
GD
1 STON
CB CB 1 AI
N CB CB
3 CB3 CB3
27.909
RT ETA C
B1 CB1 CB1
GD
1
B3 CB CB 20.092
E
L-3
B2 R S
1
C E CB318.899
R D RIE 3 3 19.524
C 18.53
CB3 CB3
C
B1 B2 LV TO D CB3
30.219
TTE =VA CB
3 3 CB
GD
GU , L 1 C C
CUEFER CB3 CB 3 CB3 20.38
CB3
CB
CB3
18.321
P. 600
1
1 B3 CB3
CB 3
AE02 TY 0 x
60 1
R
3 CB
CB
3
C
GD
2 1
CB 1 D1 CB CB CB P. 3
30.314
CAT
CE03
C CB CB
1
. 3
C
1 G ,TY 3
CB YP CB CB CH
E DRAWINGS
CB3
7
CB3
1 B1 4,T 3 4
1 E0 GD
1
GD C
1 D1 CB 22.294
CA MEN
CB CB CB 25.827
CB
1
CB
1
T-8 AI
CB
L-
8,
C
7 CB1 1 C B1 AI
N
DR IES
,G
CB
3
L-2 3
CB
3
AL
-2 REFE PACITY T PON
R TO =3
DETA 0000 m -3
D REFERENCE
CB
30.608
B1
E0 B3 NA CB
AN
30.608
1 R R IL -P3 3
ER DET
2
GD
CB
ST
-2
CB C TE VA C
CB3
,C T L= A3 3 , CE
CB3
22.972
OR EFE
LV TO 1 1 GU 0, CB
E C3
1
DWG. NO.
CANAL
3
CUEFER
-9 CB GD CB1 P. 60 CB E CCE 0 CB3
13
DRAWING TITLE
M RT
T-9 AIL
1
R
30.879
3
CB AG E 0
30.879
TY 00 x CB
25.13
W
AG D,
1
ER DET GD
AT
1 3
314,18
6 N C
CB CB
AI -C ,
R
GD
LV TO 1 3 IN
ER EC
ER DRCAT. - C, CE 03
1 CB 1 CB A -C & CB3
CB3
O
CUEFER DR T.
1
CB B 1
DRCT.
3
DR T. -
CB3
2 CB
CB
C 1 CB GS 01 CIVIL & STRUCTURAL STANDARD NOTES
S
INAGE
CB 3
CB
3 C
ER SE
A I A,
1 CB ER
31.899
R 1 SE
NA C
CB 1 CB AT R TO
31.899
2
CB CB ATR TO 3
GE E 0
B1 CB W
CB3
1 W FE FE
CA 2
C
907
1 CB 3 3
CB3
RM
1
CB CB CB CB RE
RM
24.286
RE
NA
CE 01 MASTER SITE DEVELOPMENT, CIVIL / STRUCTURAL PLAN
25.969
O
STORM REFER TO SE
L-
3
B1 B2 CB4,TYP. TO CB ST
1
C C S B3
C
,
33.474
33.474
3
56
1
CB 3
T
CB
26.347
E0 0
2 CE 02
W
CB CB
, C -1
CB CB3
7
STRUCTURAL SECTIONS- A & B
CB3
CB3
CB -11 RT
3
CB 34.63534.635
3
E
LV
1
CB CB
3
CASE-1 & 2, REINFORCED CONCRETE LINED CANAL-2
CU
3
L
CB CE 03
3
TA
1
CB3
3
CB3
CB
CB CB
3
STRUCTURAL SECTION-C
DE
CE03
36.171
24.688
TO
36.171
1
3
3 C
CB CB
CB
ER
3
4
CB
REINFORCED CONCRETE TYP. ROADS CATCH BASINS
44,7
CB3
RE
3
CB3
CB CE 04
93,11
37.036
3
CB
37.131 37.036
37.691
STRUCTURAL SECTIONS, CB1, CB2 & CB3
3
CB3
CB
CB3
CB
3 37.287 23.228
REINFORCED CONCRETE BOX CULVERTS - 1 TO 3
CE 05
3 ENLARGED SETTING OUT PLANS
CB
38.927
CB3
CB3
3
CB 39.876 REINFORCED CONCRETE BOX CULVERTS - 4 TO 7
3 3 23.095
CE 06 ENLARGED SETTING OUT PLANS
CB
40.426
CB
CB3
CB3
3
REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
39.973
3
CB CB
CE 07
3 3 ENLARGED SETTING OUT PLANS
CB
CB3
CB
CB3
39.521
ST
3 CB
3 REINFORCED CONCRETE BOX CULVERTS
OR R
CB39.885 CE 08
M EFE
TYP. LONGITUDINAL STRUCTURAL SECTION
CB3
CB3
W RT
3
54
3
CB
AT O
CB
40.373
ER SE
REINFORCED CONCRETE BOX CULVERTS ( 2 CELLS BARRELS )
6,
41.144
DR CT.
3
CB
3
CB
23.98
CE 09
13
CB3
CB3
AI -C
TYP. TRANVERSE STRUCTURAL SECTION
NA , C
42.633
3
GE E 0
3
CB
43.653
CB
C REINFORCED CONCRETE BOX CULVERTS ( 1 CELL BARREL )
CA 3
CB3
CB3
CE 10
NA
3 3 CE0
CB 3
CB C E03 TYP. TRANVERSE STRUCTURAL SECTION
L
45.295
-2
45.871
3 C
CULVERT-5
CB3
3
CB 46.809 CB REFER TO DETAIL -5, CE 06 REINFORCED CONCRETE BOX CULVERTS WINGWALL
CB3
3 CE 11
CB
3 47.872
CB GE CANAL-2 TYP. LONGITUDINAL STRUCTURAL SECTION
CB3
STORM WATER DRAINA CE 03
CB3
3 26.074
REFER TO SECT. -C ,
3 CB
CB 49.064
C 03 CE 12 CATCHMENT POND-1, ENLARGED SETTING-OUT PLAN
CE
26.658
3 STORM WATER DRAINAGE CANAL-2 CB3
49.401
CB
REFER TO SECT. -C , CE 03 27.136
CB3
CB3 28.88
CB3
15
3
3
C
CB3
CATCHMENT POND-2 & 3, ENLARGED SETTING-OUT PLAN
CE0
CE 13
4,1
32.986 30.27
CB3
4,1 CB3 ROAD
CB3 38.304 PROPOSED 36.536
CB3
CB3
6
9 CULVERT-2 2 C B 3 D CB3
CB3
CB3
1 1
L- OA CB3
D R38.359 CE 14 CATCHMENT PONDS, TYP. PART STRUCTURAL CROSS SECTION
REFER TO DETAIL -2, CE 05
A NA CB3 POSE 3
C 03 PRO CB
STO CB3
GE CE
36.657
RM CB3
NAC ,
3
REFEWATER E0
I CB3 ABOVE GROUND PUMP HOUSE & U/G LIFT WATER TANK
R TO DRA A .- CB3
C C
SEC INAG
T. -C DR CT CB3
34.957 ST 01
E
, CE CANAL E R SE CB3 STRUCTURAL SETTING - OUT & FRAMING PLANS
03 -2 CULVERT-4 AT TO CB3 33.837
CB3
51
287,04
6,5
ST
OR
7
M
RE WA
FE T
R ER
TO D
SE RA
CT IN
345,51
.- A
C G
,C EC
E 0 AN
3 A
L-
2
C
C E03
1102,28
240,46
5-5-37
STORM DRAINAGE SYSTEM
NOTES :
1. ALL DIMENSIONS ARE IN METERS, UNLESS OTHERWISE SPECIFIED.
2. ALL REINFORCED CONCRETE STRUCTURES SUCH AS CANALS , CULVERTS BARRELS & PONDS MUST BE PROVIDED WITH .20m WIDE EXPANSION JOINTS AT EVERY 6.00 m LENGTH
3. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN MASTER SITE DEVELOPMENT
4 ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS CIVIL / STRUCTURAL PLAN
5. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
6. OTHER STORM DRAINAGE SYSTEM NOT SHOWN IN THIS DRAWING MUST BE REFERRED TO MECHANICAL DRAWINGS.
SUCH AS THE PING LAYOUT, ABOVE GROUND PUMP HOUSE & U/G LIFT WATER TANK AND OTHER ACCESSORIES TO COMPLETE READY FACILITY.
AFG AFG
- - CE 01
SPECIAL NOTES
1. THIS DESIGN DRAWING IS SUBJECT FOR ANY REVISION TO SUIT THE ACTUAL
SITE CONDITION DURING IMPLEMENTATION WHICH TO BE INCORPORATED
IN THE CONTRACTOR'S SHOP DRAWINGS AND TO BE APPROVED BY HIGHER
300 VARIES, VERIFY ON SITE 300
MILITARY AUTHORITIES.
15
0
15
1 1
0
1 REINFORCED CONCRETE LINED CANAL-1 1
PROVIDE 20mm WIDE EXPANSION JT.
AT EVERY 6000mm LENGTH
1750
∅10 c200, TYP. REFERENCE DRAWINGS
∅10 c200, TYP. DWG. NO. DRAWING TITLE
150
GS 01 CIVIL & STRUCTURAL STANDARD NOTES
A REINFORCED CONCRETE LINED CANAL -1 , STRUCTURAL SECTION CE 12 CATCHMENT POND-1, ENLARGED SETTING-OUT PLAN
WATER LEVEL
VARIES, 2000 MIN.
15
0
15
1 1
REINFORCED CONCRETE LINED CANAL-3
0
1 1
PROVIDE 20mm WIDE EXPANSION JT.
AT EVERY 6000mm LENGTH
2500
∅10 c200, TYP.
∅10 c200, TYP.
150
5 / 5 / 37
.25mm ( 250 MICRON ) THK. POLYETHYLENE SHEETS
WELL COMPACTED SUBGRADE, TYP.
STORM WATER DRAINAGE SYSTEM
NOTES :
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN AFG AFG
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
TO SUIT THE ACTUAL SITE CONDITION.
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
MILITARY AUTHORITIES.
1000 2000
WALK WAY RIPRAP SHOULDER
150 OPTIONAL 150 OPTIONAL, ( TO BE VERIFIED ) 300 VARIES, VERIFY ON SITE 300
ROAD PART TRAVELED WAY
150
200
200
200
400
400
ORIENTATION
WATER LEVEL
50
50
1. FOR STRUCTURE ORIENTATION, REFER TO THE LATEST SITE PLAN.
0
15
1 1
REINFORCED CONCRETE LINED CANAL-2
1 1
PROVIDE 20mm WIDE EXPANSION JT.
AT EVERY 6000mm LENGTH
2000 REFERENCE DRAWINGS
∅10 c200, TYP. DWG. NO. DRAWING TITLE
∅10 c200, TYP.
GS 01 CIVIL & STRUCTURAL STANDARD NOTES
150
CE 01 MASTER SITE DEVELOPMENT , CIVIL/STRUCTURAL PLAN
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN REINFORCED CONCRETE BOX CULVERTS - 4 TO 7
CE 06
ENLARGED SETTING OUT PLANS
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
TO SUIT THE ACTUAL SITE CONDITION. CE 07
ENLARGED SETTING OUT PLANS
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
REINFORCED CONCRETE BOX CULVERTS
CE 08
TYP. LONGITUDINAL STRUCTURAL SECTION
REINFORCED CONCRETE BOX CULVERTS ( 2 CELLS BARRELS )
CE 09
TYP. TRANVERSE STRUCTURAL SECTION
C CASE -1, REINFORCED CONCRETE LINED CANAL -2, WITH LOW BACKSLOPE STRUCTURAL SECTION CE 10
REINFORCED CONCRETE BOX CULVERTS ( 1 CELL BARREL )
TYP. TRANVERSE STRUCTURAL SECTION
CE01
REINFORCED CONCRETE BOX CULVERTS WINGWALL
CE 11
TYP. LONGITUDINAL STRUCTURAL SECTION
200
0
ABOVE GROUND PUMP HOUSE & U/G LIFT WATER TANK
ST 01
GROUTED RIPRAP BACK SLOPE STRUCTURAL SETTING - OUT & FRAMING PLANS
1.5
1
150
200
200
200
200
400
400
WATER LEVEL
50
50
250 250
15
0
0
15
1 1
REINFORCED CONCRETE LINED CANAL-2
1 1
PROVIDE 20mm WIDE EXPANSION JT.
AT EVERY 6000mm LENGTH
2000
∅10 c200, TYP.
∅10 c200, TYP. 5 / 5 / 37
150
LONGITUDINAL ROADWAY HEAVY DUTY CAST IRON GRATES LONGITUDINAL ROADWAY HEAVY DUTY CAST IRON GRATES LONGITUDINAL ROADWAY MILITARY AUTHORITIES.
SLOPE = VARIES AS PER MANUFACTURER'S STANDARD
WATER LEVEL
600
PIPE INLET
( FROM PRECEEDING CATCHBASIN) ORIENTATION
800
1. FOR STRUCTURE ORIENTATION, REFER TO THE LATEST SITE PLAN.
SAND TRAP
1
SAND TRAP 1
150
DWG. NO. DRAWING TITLE
∅10 c200, TYP.
∅10 c200, TYP. GS 01 CIVIL & STRUCTURAL STANDARD NOTES
.25mm ( 250 MICRON ) THK. POLYETHYLENE SHEETS ∅10 c200, TYP.
2 COATS OF BITUMINOUS PAINT MATERIALS ∅10 c200, TYP.
CE 01 MASTER SITE DEVELOPMENT , CIVIL/STRUCTURAL PLAN
WELL COMPACTED SUBGRADE, TYP. .25mm ( 250 MICRON ) THK. POLYETHYLENE SHEETS
2 COATS OF BITUMINOUS PAINT MATERIALS REINFORCED CONCRETE LINED CANAL-1 & 3
WELL COMPACTED SUBGRADE, TYP. CE 02
TYPICAL CATCHBASIN, CB-1 .25mm ( 250 MICRON ) THK. POLYETHYLENE SHEETS
STRUCTURAL SECTIONS- A & B
CASE-1 & 2, REINFORCED CONCRETE LINED CANAL-2
( 800 x 800 x 600 ) TYPICAL CATCHBASIN, CB-2 WELL COMPACTED SUBGRADE, TYP. CE 03
STRUCTURAL SECTION-C
NOTES : CE 06
REINFORCED CONCRETE BOX CULVERTS - 4 TO 7
ENLARGED SETTING OUT PLANS
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.
REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN CE 07
ENLARGED SETTING OUT PLANS
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
REINFORCED CONCRETE BOX CULVERTS
TO SUIT THE ACTUAL SITE CONDITION. CE 08
TYP. LONGITUDINAL STRUCTURAL SECTION
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS. REINFORCED CONCRETE BOX CULVERTS ( 2 CELLS BARRELS )
CE 09
TYP. TRANVERSE STRUCTURAL SECTION
REINFORCED CONCRETE BOX CULVERTS ( 1 CELL BARREL )
CE 10
TYP. TRANVERSE STRUCTURAL SECTION
REINFORCED CONCRETE BOX CULVERTS WINGWALL
CE 11
TYP. LONGITUDINAL STRUCTURAL SECTION
- REINFORCED CONCRETE TYPICAL CATCHBASINS, CB-1 & CB-2, AT SECONDARY ROADS STRUCTURAL SECTION CE 12 CATCHMENT POND-1, ENLARGED SETTING-OUT PLAN
CE01
CE 13 CATCHMENT POND-2 & 3, ENLARGED SETTING-OUT PLAN
1000 VARIES
WALK WAY RIPRAP SHOULDER
150 OPTIONAL 150 OPTIONAL, ( TO BE VERIFIED ) 300 VARIES, VERIFY ON SITE 300
ROAD PART TRAVELED WAY HEAVY DUTY CAST IRON GRATES
200
200
400
400
VARIES, 1000 MIN.
WATER LEVEL
50
50
2000
∅10 c200, TYP.
∅10 c200, TYP.
150
0
220
400
0
ORIENTATION
1. FOR STRUCTURE ORIENTATION, REFER TO THE LATEST SITE PLAN.
15 S
RT
00
50 VE
y
0x
L
REFERENCE DRAWINGS
CU
CE
EL OX
-1
06 DWG. NO. DRAWING TITLE
.B
LS
RC
GS 01 CIVIL & STRUCTURAL STANDARD NOTES
2C
CE 01 MASTER SITE DEVELOPMENT , CIVIL/STRUCTURAL PLAN
X6
300 R. 2000 VA
40
REINFORCED CONCRETE BOX CULVERTS - 4 TO 7
00
VA
CE 06
CE0
ENLARGED SETTING OUT PLANS
NOTES : CE 07
REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
ENLARGED SETTING OUT PLANS
2200 1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN REINFORCED CONCRETE BOX CULVERTS
CE 08
R.
300
TYP. LONGITUDINAL STRUCTURAL SECTION
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
REINFORCED CONCRETE BOX CULVERTS ( 2 CELLS BARRELS )
TO SUIT THE ACTUAL SITE CONDITION. CE 09
TYP. TRANVERSE STRUCTURAL SECTION
Z
07
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS. REINFORCED CONCRETE BOX CULVERTS ( 1 CELL BARREL )
CE 10
CE
TYP. TRANVERSE STRUCTURAL SECTION
REINFORCED CONCRETE BOX CULVERTS WINGWALL
CE 11
TYP. LONGITUDINAL STRUCTURAL SECTION
1 REINFORCED CONCRETE BOX CULVERT -1, SETTING-OUT PLAN CE 13 CATCHMENT POND-2 & 3, ENLARGED SETTING-OUT PLAN
CE01 SCALE : NTS
CE 14 CATCHMENT PONDS, TYP. PART STRUCTURAL CROSS SECTION
X
CE06 2200
0 VAR.
X Z
0
VAR. 20
4000
CE0 CE07
6
300
CE06
R.
220
0 VA
0
300 AR. 200
CE
220
Z RC
0
0
300
V
2 .B
6
y
CE OX
CE07 LL
S
-1
CU
RC. LV
0
50
300
1 C BOX C ER
AR.
300
ELL 0 T
- 20 ULVER x
15
0V
x 15 T
00 00
. 200
00
VAR
22
300
00 5 / 5 / 37
00
40
22
.
AR
00
NOTES : NOTES :
V
REINFORCED CONCRETE BOX CULVERTS - 1 TO 3
00
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.
20
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.
ENLARGED SETTING OUT PLANS
R.
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
VA
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS 3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
TO SUIT THE ACTUAL SITE CONDITION. TO SUIT THE ACTUAL SITE CONDITION. AFG AFG
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS. 4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
VA 1. THIS DESIGN DRAWING IS SUBJECT FOR ANY REVISION TO SUIT THE ACTUAL
30 R
0 .2 SITE CONDITION DURING IMPLEMENTATION WHICH TO BE INCORPORATED
00 IN THE CONTRACTOR'S SHOP DRAWINGS AND TO BE APPROVED BY HIGHER
VA
R MILITARY AUTHORITIES.
CE0
.
Z
30 VAR. 2000
0 300 VAR.
7
300
4000 ORIENTATION
2200
2200
1. FOR STRUCTURE ORIENTATION, REFER TO THE LATEST SITE PLAN.
y
CE
40
06
00
CE06
X
00
22
T S REFERENCE DRAWINGS
ER 00
U LV x 15 DWG. NO. DRAWING TITLE
XC 00
40
BO S - 15
00
GS 01
30 VA
X 06 RC EL
L
0 R. 2
2C CE 01 MASTER SITE DEVELOPMENT , CIVIL/STRUCTURAL PLAN
CE 20
0
00
2 REINFORCED CONCRETE LINED CANAL-1 & 3
CE 02
0V
STRUCTURAL SECTIONS- A & B
AR
30
CASE-1 & 2, REINFORCED CONCRETE LINED CANAL-2
0
.
CE 03
STRUCTURAL SECTION-C
Z
REINFORCED CONCRETE TYP. ROADS CATCH BASINS
07
CE 04
STRUCTURAL SECTIONS AT CB-1, CB-2 & CB-3
CE
REINFORCED CONCRETE BOX CULVERTS - 1 TO 3
CE 05
Y ENLARGED SETTING OUT PLANS
REINFORCED CONCRETE BOX CULVERTS - 4 TO 7
CE06 CE 06
ENLARGED SETTING OUT PLANS
NOTES :
REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED. CE 07
ENLARGED SETTING OUT PLANS
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
REINFORCED CONCRETE BOX CULVERTS
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS CE 08
TYP. LONGITUDINAL STRUCTURAL SECTION
TO SUIT THE ACTUAL SITE CONDITION. REINFORCED CONCRETE BOX CULVERTS ( 2 CELLS BARRELS )
2200
2200
CE 09
4000 TYP. TRANVERSE STRUCTURAL SECTION
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
REINFORCED CONCRETE BOX CULVERTS ( 1 CELL BARREL )
CE 10
TYP. TRANVERSE STRUCTURAL SECTION
REINFORCED CONCRETE BOX CULVERTS WINGWALL
CE 11
TYP. LONGITUDINAL STRUCTURAL SECTION
300 300
VAR. 200 VAR. 6 REINFORCED CONCRETE BOX CULVERT - 6, SETTING-OUT PLAN CE 12 CATCHMENT POND-1, ENLARGED SETTING-OUT PLAN
X 06
CE
Z 5
CE 00 R.
07 15 VA 300
4
15
0 PRELIMINARY ISSUE DEC., 2018
00
VAR.2000 VAR. 00 REVISIONS SUBJECT DATE
300 300 25 CE
Y 06
15
CE06
00
Y
RC CELL
2200
1
300
.B -1
VAR. 2000 VAR.
CE06
OX 50
15
2200
CU 0 x
00
LV 150
3000
3000
00
ER 0
25
T
15
RC. BOX CULVERT
00
Z
300
2200
07
0
30 .
R
VA STORM WATER DRAINAGE SYSTEM
0 .
30 AR 500
V 1
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED. ENLARGED SETTING OUT PLAN
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
300 300 2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
VAR. 2000 VAR. 3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS AFG AFG
TO SUIT THE ACTUAL SITE CONDITION.
TO SUIT THE ACTUAL SITE CONDITION.
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
5 REINFORCED CONCRETE BOX CULVERT - 5, SETTING-OUT PLAN 7 REINFORCED CONCRETE BOX CULVERT - 7, SETTING-OUT PLAN
CE01 SCALE : NTS CE01 SCALE : NTS
D XX XXXX CE 06
SPECIAL NOTES
X
1. THIS DESIGN DRAWING IS SUBJECT FOR ANY REVISION TO SUIT THE ACTUAL
CE
X
CE
Z SITE CONDITION DURING IMPLEMENTATION WHICH TO BE INCORPORATED
06
Z
06
IN THE CONTRACTOR'S SHOP DRAWINGS AND TO BE APPROVED BY HIGHER
CE .
00 AR 0
07 1 5 V 30 CE .
00 AR 00
MILITARY AUTHORITIES.
. 07 1 5 V 3
R
VA R .
0 VA
30 0
30
15
0
15
0
00
00
25 CE 00
25 CE ORIENTATION
Y 06
15
06
00
15
Y 1. FOR STRUCTURE ORIENTATION, REFER TO THE LATEST SITE PLAN.
00
RC CELL
1
RC CELL
.B -1
.B -1
OX 50
15
OX 5 0
0
CU 0 x
15
0
CU 0 x
00
LV 150
00
LV 150
ER 0
25 00
ER 0
25
T
15
T
REFERENCE DRAWINGS
15
0
00
DWG. NO. DRAWING TITLE
0
30 . GS 01 CIVIL & STRUCTURAL STANDARD NOTES
00 AR 0
R
15 V 3
VA
.
0 . CE 01 MASTER SITE DEVELOPMENT , CIVIL/STRUCTURAL PLAN
30 AR 500
V 1
R
30
VA
REINFORCED CONCRETE LINED CANAL-1 & 3
CE 02
STRUCTURAL SECTIONS- A & B
NOTES : NOTES : CASE-1 & 2, REINFORCED CONCRETE LINED CANAL-2
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED. 1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED. CE 03
STRUCTURAL SECTION-C
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN 2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN REINFORCED CONCRETE TYP. ROADS CATCH BASINS
CE 04
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS 3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS STRUCTURAL SECTIONS AT CB-1, CB-2 & CB-3
TO SUIT THE ACTUAL SITE CONDITION. TO SUIT THE ACTUAL SITE CONDITION. REINFORCED CONCRETE BOX CULVERTS - 1 TO 3
CE 05
ENLARGED SETTING OUT PLANS
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS. 4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
REINFORCED CONCRETE BOX CULVERTS - 4 TO 7
CE 06
ENLARGED SETTING OUT PLANS
REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
CE 07
ENLARGED SETTING OUT PLANS
8 REINFORCED CONCRETE BOX CULVERT - 8, SETTING-OUT PLAN 9 REINFORCED CONCRETE BOX CULVERT - 9, SETTING-OUT PLAN CE 08
REINFORCED CONCRETE BOX CULVERTS
TYP. LONGITUDINAL STRUCTURAL SECTION
CE01 SCALE : NTS CE01 SCALE : NTS CE 09
REINFORCED CONCRETE BOX CULVERTS ( 2 CELLS BARRELS )
TYP. TRANVERSE STRUCTURAL SECTION
REINFORCED CONCRETE BOX CULVERTS ( 1 CELL BARREL )
CE 10
TYP. TRANVERSE STRUCTURAL SECTION
REINFORCED CONCRETE BOX CULVERTS WINGWALL
X 06
CE 11
CE
TYP. LONGITUDINAL STRUCTURAL SECTION
22
ABOVE GROUND PUMP HOUSE & U/G LIFT WATER TANK
ST 01
00
STRUCTURAL SETTING - OUT & FRAMING PLANS
00
45 CE
30
0 Y 06
VA
22
R
00
.2
CB
00
-4
0V
A T C H BASIN, CB-4 AR
B-4
CB
T YP. C ,C
30
.
VAR.
-4
600 x 100
0x
0 A SIN.
CB
B R
CE06
VA
30
CH x VA
y
-4
0
RC CELL
T
R
2
A 0
.2
C 0
.B S-
P. x 10
00
OX 20
Y
0V
T 0
CB
2200 60
AR 300
CU 00 x
-4
CB-4
X CB-4
.
LV 20
CB-4
300
CB
CB-4
ER 00
CB-4
-4
VAR.
CE06
TS
CB-4
4000
CB-4 LVERTS
CB
RC. BOX CU 0 x 1500
22
1500
-4
00
50
2 CELLS - 1
Z
VAR.
300
2200 00
CE07 45
22
00
30
0
VA
R
.2
00
0V
AR 30 5 / 5 / 37
. 0
30 VA
0 R.
STORM WATER DRAINAGE SYSTEM
2
00
0V
NOTES :
AR
30
NOTES : REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
0
.
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED. 1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
ENLARGED SETTING OUT PLAN
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS 3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
TO SUIT THE ACTUAL SITE CONDITION. TO SUIT THE ACTUAL SITE CONDITION.
AFG AFG
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS. 4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
MILITARY AUTHORITIES.
ORIENTATION
1. FOR STRUCTURE ORIENTATION, REFER TO THE LATEST SITE PLAN.
150
STRUCTURAL SECTION-C
100
.25 THK. POLYETHYLENE SHEETS, TYP. REINFORCED CONCRETE BOX CULVERTS - 1 TO 3
15
97 % COMPACTED STRUCTURAL SELECT FILL MATERIALS, TYP. CE 05
ENLARGED SETTING OUT PLANS
0
150 150
2 COATS OF BITUMINOUS MAT'LS. , TYP.
600, MIN.
100 100 100 100 REINFORCED CONCRETE BOX CULVERTS - 4 TO 7
6 Ø14, TOTAL CE 06
ENLARGED SETTING OUT PLANS
Ø10 c 200 REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
CE 07
ENLARGED SETTING OUT PLANS
400, MIN.
RC HEADWALL REINFORCED CONCRETE BOX CULVERTS ( 2 CELLS BARRELS )
CE 09
TYP. TRANVERSE STRUCTURAL SECTION
250
REINFORCED CONCRETE BOX CULVERTS ( 1 CELL BARREL )
CE 10
TYP. TRANVERSE STRUCTURAL SECTION
LL
2000, MIN.
A
GW
REINFORCED CONCRETE BOX CULVERTS WINGWALL
Ø12 c200 CE 11
N
WI
TYP. LONGITUDINAL STRUCTURAL SECTION
Ø10 c200
4 Ø14, TOTAL RC CULVERT BARRELS CE 12 CATCHMENT POND-1, ENLARGED SETTING-OUT PLAN
2000
1500
2 COATS OF BITUMINOUS MAT'LS. , TYP. 100 THK. LEVELING CONC. PROVIDE 20mm WIDE EXPANSION JT.
.25 THK. POLYETHYLENE SHEETS, TYP. AT EVERY 6000mm LENGTH CE 13 CATCHMENT POND-2 & 3, ENLARGED SETTING-OUT PLAN
WELL COMPACTED SUBGRADE
400
APPROX. REINFORCED CONCRETE LINED CANAL INVERT 800 APPROX. CULVERTS INVERT CE 14 CATCHMENT PONDS, TYP. PART STRUCTURAL CROSS SECTION
IJ. RC APPRON IJ. ABOVE GROUND PUMP HOUSE & U/G LIFT WATER TANK
ST 01
150
200
250
350
350
100
200 VARIES 20020 250
NOTES :
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
TO SUIT THE ACTUAL SITE CONDITION.
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
5 / 5 / 37
AFG AFG
MILITARY AUTHORITIES.
300
REINFORCED CONCRETE BOX CULVERTS - 4 TO 7
4 Ø16, TYP. CE 06
ENLARGED SETTING OUT PLANS
125
125
125
125
REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
Ø16 c 200, TYP. CE 07
ENLARGED SETTING OUT PLANS
125 Ø16 c 200, TYP. 125 125 125
Ø12 c 400, TYP. CULVERT BARRELS CE 08
REINFORCED CONCRETE BOX CULVERTS
PROVIDE 20mm WIDE EXPANSION JT. TYP. LONGITUDINAL STRUCTURAL SECTION
1500
1600
Ø12 c 200, TYP.
AT EVERY 6000mm LENGTH REINFORCED CONCRETE BOX CULVERTS ( 2 CELLS BARRELS )
Ø16 c 200, TYP. CE 09
300 300 300 300 TYP. TRANVERSE STRUCTURAL SECTION
Ø16 c 200, TYP.
125 125 125 125 REINFORCED CONCRETE BOX CULVERTS ( 1 CELL BARREL )
Ø12 c 200, TYP. CE 10
TYP. TRANVERSE STRUCTURAL SECTION
125
125
125
125
REINFORCED CONCRETE BOX CULVERTS WINGWALL
CE 11
4 Ø16, TYP. TYP. LONGITUDINAL STRUCTURAL SECTION
300
CE 12 CATCHMENT POND-1, ENLARGED SETTING-OUT PLAN
100
CE 13 CATCHMENT POND-2 & 3, ENLARGED SETTING-OUT PLAN
NOTES :
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
TO SUIT THE ACTUAL SITE CONDITION.
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
5 / 5 / 37
AFG AFG
MILITARY AUTHORITIES.
250
REINFORCED CONCRETE BOX CULVERTS - 4 TO 7
CE 06
ENLARGED SETTING OUT PLANS
125
125
REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
CE 07
ENLARGED SETTING OUT PLANS
125 125
CULVERT BARREL CE 08
REINFORCED CONCRETE BOX CULVERTS
TYP. LONGITUDINAL STRUCTURAL SECTION
2000
2000
1500
1500
PROVIDE 20mm WIDE EXPANSION JT.
AT EVERY 6000mm LENGTH REINFORCED CONCRETE BOX CULVERTS ( 2 CELLS BARRELS )
300 300 CE 09
TYP. TRANVERSE STRUCTURAL SECTION
125 125 REINFORCED CONCRETE BOX CULVERTS ( 1 CELL BARREL )
CE 10
TYP. TRANVERSE STRUCTURAL SECTION
125
125
REINFORCED CONCRETE BOX CULVERTS WINGWALL
CE 11
TYP. LONGITUDINAL STRUCTURAL SECTION
250
250
CE 12 CATCHMENT POND-1, ENLARGED SETTING-OUT PLAN
100
100
CE 13 CATCHMENT POND-2 & 3, ENLARGED SETTING-OUT PLAN
NOTES :
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
TO SUIT THE ACTUAL SITE CONDITION.
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
5 / 5 / 37
AFG AFG
MILITARY AUTHORITIES.
ORIENTATION
1. FOR STRUCTURE ORIENTATION, REFER TO THE LATEST SITE PLAN.
150
STRUCTURAL SECTIONS- A & B
CASE-1 & 2, REINFORCED CONCRETE LINED CANAL-2
100
.15 THK. POLYETHYLENE SHEETS, TYP. REINFORCED CONCRETE TYP. ROADS CATCH BASINS
15
CE 04
97 % COMPACTED STRUCTURAL SELECT FILL MATERIALS, TYP. STRUCTURAL SECTIONS AT CB-1, CB-2 & CB-3
0
150 150
2 COATS OF BITUMINOUS MAT'LS. , TYP.
600, MIN.
REINFORCED CONCRETE BOX CULVERTS - 1 TO 3
100 100 100 100 CE 05
ENLARGED SETTING OUT PLANS
6 Ø14, TOTAL
Ø10 c 200 REINFORCED CONCRETE BOX CULVERTS - 4 TO 7
CE 06
ENLARGED SETTING OUT PLANS
REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
CE 07
ENLARGED SETTING OUT PLANS
400, MIN.
RC HEADWALL CE 08
REINFORCED CONCRETE BOX CULVERTS
Ø12 c200, BOTHWAYS & BOTH FACES TYP. LONGITUDINAL STRUCTURAL SECTION
250
Ø10 c200x200 WWF, TOP & BTM, TYP. REINFORCED CONCRETE BOX CULVERTS ( 2 CELLS BARRELS )
CE 09
Ø10 c 200 TYP. TRANVERSE STRUCTURAL SECTION
LL
2000, MIN.
2000
1500
70 THK. LEVELING CONC. AT EVERY 6000mm LENGTH
.15 THK. POLYETHYLENE SHEETS, TYP. CE 12 CATCHMENT POND-1, ENLARGED SETTING-OUT PLAN
WELL COMPACTED STRUCTURAL GRAVEL DRAINAGE FILL MATERIALS, TYP.
400
APPROX. REINFORCED CONCRETE LINED CANAL INVERT 800 WELL COMPACTED SUBGRADE APPROX. CULVERTS INVERT CE 13 CATCHMENT POND-2 & 3, ENLARGED SETTING-OUT PLAN
200
RC APPRON
250
350
350
ABOVE GROUND PUMP HOUSE & U/G LIFT WATER TANK
ST 01
STRUCTURAL SETTING - OUT & FRAMING PLANS
100
200 VARIES 20020 250
NOTES :
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
TO SUIT THE ACTUAL SITE CONDITION.
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
5 / 5 / 37
AFG AFG
MILITARY AUTHORITIES.
ORIENTATION
1. FOR STRUCTURE ORIENTATION, REFER TO THE LATEST SITE PLAN.
REFERENCE DRAWINGS
DWG. NO. DRAWING TITLE
GS 01 CIVIL & STRUCTURAL STANDARD NOTES
1000
REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
CE 07
ENLARGED SETTING OUT PLANS
10
00
0
W
13
14
0
14
CE
VAR. VAR 31
2000 . 78
0
VA R.
R. VA
V A R.
28860 SITE CONDITION DURING IMPLEMENTATION WHICH TO BE INCORPORATED
88560 IN THE CONTRACTOR'S SHOP DRAWINGS AND TO BE APPROVED BY HIGHER
MILITARY AUTHORITIES.
49480
1000
VAR.
VAR.
ORIENTATION
1. FOR STRUCTURE ORIENTATION, REFER TO THE LATEST SITE PLAN.
REFERENCE DRAWINGS
REINFORCED CONCRETE LINED POND-3
DWG. NO. DRAWING TITLE
CAPACITY= 30000 m3
PROVIDE 20mm WIDE EXPANSION JT. GS 01 CIVIL & STRUCTURAL STANDARD NOTES
.
AR AT EVERY 6000mm LENGTH
VA
V
CE 01 MASTER SITE DEVELOPMENT , CIVIL/STRUCTURAL PLAN
R
.
REINFORCED CONCRETE LINED CANAL-1 & 3
CE 02
STRUCTURAL SECTIONS- A & B
CASE-1 & 2, REINFORCED CONCRETE LINED CANAL-2
CE 03
STRUCTURAL SECTION-C
66
REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
8
CE 07
0
ENLARGED SETTING OUT PLANS
00
10 CE 08
REINFORCED CONCRETE BOX CULVERTS
TYP. LONGITUDINAL STRUCTURAL SECTION
0
17434
1000 REINFORCED CONCRETE BOX CULVERTS ( 2 CELLS BARRELS )
. LOOSE STONE CE 09
AR TYP. TRANVERSE STRUCTURAL SECTION
V
W CE 10
REINFORCED CONCRETE BOX CULVERTS ( 1 CELL BARREL )
TYP. TRANVERSE STRUCTURAL SECTION
CE14
REINFORCED CONCRETE BOX CULVERTS WINGWALL
VA
CE 11
R.
VA
1000
R.
CATCHMENT POND-2 & 3, ENLARGED SETTING-OUT PLAN
0
CE 13
17434
. CE 14 CATCHMENT PONDS, TYP. PART STRUCTURAL CROSS SECTION
R
VA
ABOVE GROUND PUMP HOUSE & U/G LIFT WATER TANK
0 ST 01
12 STRUCTURAL SETTING - OUT & FRAMING PLANS
0 11
0
10
AR.
66
. V
0
80
10
250
VAR
00
WE14
C 00
0
5
60
ABOVE GROUND PUMP HOUSE 2 60
4
37 3
& U/G LIFT WATER TANK,
2
PIPING LAYOUT & OTHER ACCESSORIES 1
MUST BE REFERRED TO THE MECHANICAL DWGS. 0 PRELIMINARY ISSUE DEC., 2018
REVISIONS SUBJECT DATE
VA
R.
R.
VA
5 / 5 / 37
VAR.
STORM WATER DRAINAGE SYSTEM
1000
87960
CATCHMENT PONDS-2 & 3
SETTING OUT PLANS
NOTES : NOTES :
VAR.
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED. 1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.
VAR.
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN 2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
AFG AFG
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS 3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
TO SUIT THE ACTUAL SITE CONDITION. TO SUIT THE ACTUAL SITE CONDITION.
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS. 4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
MILITARY AUTHORITIES.
ORIENTATION
1. FOR STRUCTURE ORIENTATION, REFER TO THE LATEST SITE PLAN.
REFERENCE DRAWINGS
DWG. NO. DRAWING TITLE
GS 01 CIVIL & STRUCTURAL STANDARD NOTES
200
REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
CE 07
ENLARGED SETTING OUT PLANS
WATER LEVEL CE 08
REINFORCED CONCRETE BOX CULVERTS
TYP. LONGITUDINAL STRUCTURAL SECTION
REINFORCED CONCRETE BOX CULVERTS ( 2 CELLS BARRELS )
CE 09
TYP. TRANVERSE STRUCTURAL SECTION
0
15
REINFORCED CONCRETE BOX CULVERTS ( 1 CELL BARREL )
1 CE 10
TYP. TRANVERSE STRUCTURAL SECTION
1
REINFORCED CONCRETE BOX CULVERTS WINGWALL
CE 11
3000 TYP. LONGITUDINAL STRUCTURAL SECTION
150
300
LOOSE STONE CATCHMENT PONDS, TYP. PART STRUCTURAL CROSS SECTION
CE 14
200 ABOVE GROUND PUMP HOUSE & U/G LIFT WATER TANK
ST 01
STRUCTURAL SETTING - OUT & FRAMING PLANS
NOTES :
1. ALL DIMENSIONS & SIZES ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
TO SUIT THE ACTUAL SITE CONDITION.
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
5 / 5 / 37
CATCHMENTS PONDS
TYP. PART STRUCTURAL CROSS SECTION
AFG AFG
MILITARY AUTHORITIES.
GENERAL NOTES STRUCTURAL DESIGN CRITERIA NOTES
1. ALL DIMENSIONS AND SIZES ARE IN THE CIVIL SITE DEVELOPMENT PLAN FOR CULVERTS & PROPOSED ROADS
ARE IN METERS UNLESS OTHERWISE NOTED.
2. ALL DIMENSIONS AND SIZES ARE IN THE STRUCTURAL PLANS & SECTIONS 1. THERE ARE TWO GROUPS OF CULVERTS COVERED BY THIS DESIGN. THEY ARE GROUPED AS
ARE IN MILLIMETERS UNLESS OTHERWISE NOTED. CAST IN PLACE REINFORCED CONCRETE ONE-CELL CULVERTS & TWO-CELLS CULVERTS.
3. ALL ACTUAL ELEVATIONS BASED ON THE SET DATUM ARE IN 2. THE RANGE OF EARTH FILL DEPTHS OVER THE CULVERTS ARE ASSUMED AS .60m TO 1.50m
ORIENTATION
METERS UNLESS NOTED OTHERWISE. 3. THE RANGE OF EARTH FILL DEPTHS OVER THE CULVERTS ARE ASSUMED AS .60m TO 1.50m 1. FOR STRUCTURE ORIENTATION, REFER TO THE LATEST SITE PLAN.
4. ALL ASSUMED ELEVATIONS BASED FROM ANY STRUCTURAL LEVEL ARE 4. LOADS IN THE DESIGN OF CULVERTS ARE DEAD LOADS FROM WEIGHT OF
IN MILLIMETERS UNLESS NOTED OTHERWISE.
OVERBURDEN, CULVERT CONCRETE, VEHICLE LOADS, IMPACT STRESSES FOR FILLS
5. DRAWINGS SHALL NOT BE SCALED. AND EARTH SURCHARGE LATERAL PRESSURES.
6. ALL STRUCTURAL WORKS AND MATERIALS SHALL CONFORM TO 5. THE ASSUMED NET ALLOWABLE PRESSURE OF SOIL IS 100 kPa.
THE REQUIREMENTS OF THE PROJECT SPECIFICATIONS.
6. SEISMIC LOADS = USE ZONE-1
7. ALL DIMENSIONS AND CONDITIONS AFFECTING THE WORK ON SITE SHALL
FOR STORM DRAINAGE CANALS REFERENCE DRAWINGS
BE VERIFIED BY THE CONSTRUCTION CONTRACTOR.
DWG. NO. DRAWING TITLE
8. WHERE THERE EXISTS CONFLICT, DISCREPANCY OR AMBIGUITY BETWEEN 1. ALL CAST IN PLACE REINFORCED CONCRETE LINED CANALS AND SLOPE PROTECTION ARE
THE DRAWINGS AND THE PROJECT SPECIFICATION THE FORMER SHALL ARE STRUCTURALLY DESIGNED TO WITHSTAND THEIR SELF WEIGHTS, EARTH LATERAL GS 01 CIVIL & STRUCTURAL STANDARD NOTES
GOVERN AND SHALL BE RESOLVED WITH THE ENGINEER. PRESSURE, AND STORM WATER IMPACT STRESSES.
2. THE ASSUMED NET ALLOWABLE PRESSURE OF SOIL IS 100 kPa. CE 01 MASTER SITE DEVELOPMENT, CIVIL / STRUCTURAL PLAN
9. ALL STRUCTURAL DRAWINGS SHALL BE READ IN CONJUNCTION WITH
ALL OTHER RELATED ARCHITECTURAL, SEWACE, ELECTRICAL WATER SUPPLY 3. SEISMIC LOADS = USE ZONE-1
REINFORCED CONCRETE LINED CANAL-1 & 3
AND MECHANICAL DRAWINGS. CE 02
FOR TRANSFER UNDERGROUND STORM WATER TANK STRUCTURAL SECTIONS- A & B
CASE-1 & 2, REINFORCED CONCRETE LINED CANAL-2
1.THIS TANK IS STRUCTURALLY DESIGNED TO WITHSTAND THE EARTH LATERAL PRESSURE CE 03
STRUCTURAL SECTION-C
EARTHWORKS NOTES ARE STRUCTURALLY DESIGNED TO WITHSTAND ITS SELF WEIGHT, EARTH LATERAL
PRESSURE WHEN EMPTY, AND STORM WATER LOADS WITH IMPACT STRESSES AND CE 04
REINFORCED CONCRETE TYP. ROADS CATCH BASINS
MOUNTED PUMP HOUSE LOADS IMPACT STRESSES WHEN THE TANK . STRUCTURAL SECTIONS, CB1, CB2 & CB3
REINFORCED CONCRETE BOX CULVERTS - 1 TO 3
2. THE ASSUMED NET ALLOWABLE PRESSURE OF SOIL IS 100 kPa. CE 05
1. CBR TEST WILL BE CARRIED OUT TO HDM 1, TABLE 2,06.2 (FOR DEFINITION ENLARGED SETTING OUT PLANS
OF THE SOIL STRENGTH CBR, SEE HDM GLOSSARY). 3. SEISMIC LOADS = USE ZONE-1
REINFORCED CONCRETE BOX CULVERTS - 4 TO 7
CE 06
ENLARGED SETTING OUT PLANS
2. DURING CONSTRUCTION STAGE , THE FOLLOWNG TEST FOR PREPARED SUBGRADE FOR PUMP HOUSE
REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
SHALL BE CONDUCTED WITH THE FOLLOWING FREQUENCY: 1.THIS PUMP HOUSE IS STRUCTURALLY DESIGNED TO WITHSTAND THE FOLLOWING : CE 07
ENLARGED SETTING OUT PLANS
a. MATERIAL CLASSIFICATION : MINIMUM ONE TEST PER 5000 SQUARE METERS OF A. DEAD LOADS = SELFWEIGHT PLUS OTHER RELATED LOADS REINFORCED CONCRETE BOX CULVERTS
CE 08
COMPLETED SUBGRADE. B. LIVELOADS = 2.0 kPa TYP. LONGITUDINAL STRUCTURAL SECTION
C. WIND LOADS = USE WIND VELOCITY EQUAL TO 150 kph REINFORCED CONCRETE BOX CULVERTS ( 2 CELLS BARRELS )
b. CALIFORNIA BEARING RATIO : MINIMUM ONE TEST PER 5000 SQUARE METERS OF CE 09
TYP. TRANVERSE STRUCTURAL SECTION
COMPLETED SUBGRADE. D. SEISMIC LOADS = USE ZONE-1
REINFORCED CONCRETE BOX CULVERTS ( 1 CELL BARREL )
CE 10
TYP. TRANVERSE STRUCTURAL SECTION
c. MOISTURE DENSITY : MINIMUM ONE TEST PER 2000 SQUARE METERS
PER LAYER.
ABBREVIATION NOTES CE 11
REINFORCED CONCRETE BOX CULVERTS WINGWALL
TYP. LONGITUDINAL STRUCTURAL SECTION
3. THE PREPARED SUBGRADE SHALL HAVE A SPECIFIED MIN. CBR OF 25 AND WHEN
CE 12 CATCHMENT POND-1, ENLARGED SETTING-OUT PLAN
THE SUBGRADE MATERIAL HAS A CBR VALUE OF LESS THAN 25 BUT NOT LESS
1. BB-BOND BEAM. 31. JT-JOINT.
12, A 250 mm LAYER OF SUBBASE MATERIAL MEETING THIS REQUIREMENT SHALL
BE PLACED. 2. B1-BEAM MARK. 32. LAT-LATERAL. CE 13 CATCHMENT POND-2 & 3, ENLARGED SETTING-OUT PLAN
5. STRUCTURALL FILL MATERIALS SHALL BE PLACED UNDER ALL SHALLOW 3. BLDG-BUILDING. 33. MAX-MAXIMUM.
CE 14 CATCHMENT PONDS, TYP. PART STRUCTURAL CROSS SECTION
FOUNDATIONS, PAVED AREAS AND GRADE SLABS IF UNSUITABLE BEARING 4. BM-BEAM. 34. MIN-MINIMUM.
MATERIALS ARE ENCOUNTERED AT THE REQUIRED SUBGRADE ELEVATIONS 5. BTM-BOTTOM. 35. NO.-NUMBER. ABOVE GROUND PUMP HOUSE & U/G LIFT WATER TANK
ST 01
7. THESE NOTES ARE TO BE READ IN CONJUNCTION WITH THE SOIL 6. COL-COLUMN. 36. NTS-NOT TO SCALE. STRUCTURAL SETTING - OUT & FRAMING PLANS
INVESTIGATION REPORT AT SITE PRIOR TO CONSTRUCTION. 7. CONT-CONTINUOUS. 37. PLT-PLATE.
8. COV-COVER. 38. P1-PEDESTAL MARK.
10. CONSTRUCTION JOINT SHALL BE REQUESTED IN WRITING FOR APPROVAL TWO STORM DRAINAGE SYSTEM
WEEKS BEFORE THEIR NEED.
11. EXPANSION JOINT FILLER SHALL BE PREMOULDED, NON-EXTRUDING TYPE CONFORMING
TO ASTM D-544 OR APPROVED EQUAL.
CIVIL & STRUCTURAL
STANDARD NOTES
AFG AFG
- AFG
1 2
RAMP UP
A
PUMP ROOM
CONTROL PANEL
1 2
B
SPECIAL NOTES:
1. THIS DESIGN DRAWING IS SUBJECT FOR ANY REVISION TO SUIT THE ACTUAL
SITE CONDITION DURING IMPLEMENTATION WHICH TO BE INCORPORATED
IN THE CONTRACTOR'S SHOP DRAWINGS AND TO BE APPROVED BY HIGHER
MILITARY AUTHORITIES.
2. SEE DRAWING NO. XM01 FOR GENERAL NOTES, LEGEND AND DETAILS OF
PUMP ROOM. THIS MUST BE READ IN CONJUNCTION WITH ALL OTHER
178,66 MECHANICAL DRAWINGS AND RELATED DRAWINGS OF OTHER TRADES.
CATCHMEN
CAPACITY=2
T POND-1 - 2
ND
,63
0000 m3
PO m3
8 T 0
33 MEN =800
H I T Y
LOOSE STONE TC PAC
CA CA 2487,44
Ø2
ORIENTATION
~
00 ~
E
200 OS
Ø2
0 0 2-ØU/G NK LO ONE
UP
TO TER TA
RAMP
WA ST 1. FOR STRUCTURE ORIENTATION, REFER TO THE LATEST SITE PLAN.
PUMP HOUSE
& U/G WATER TANK
SEE DRAW. NO. XM01 00 3
2 00 Ø2 CB
L-
2 FOR DETAILS CB Ø2 3
A B1 CB STORM
AN 1 CØ160 160 WATER
W
60
Ø
C CB 3 DRAINAG
Ø1
E 1 CB E CANAL
NA
G
Ø16
0
CB -2
AI 1 1 3
DR CB CB CB
,91
0
B3
ST
ER 16
Ø C 3
AT
OR
STORM
60 1 60 CB WATER
W Ø1 CB Ø1
M
1 1 60 DRAINAG
336
RM CB CB Ø1 E CANAL
W
3 3
O 1 0
CB CB B3 -2
AT
20
ST GD 110
10
1 Ø 60 C
ER
Ø1
Ø1
CB
Ø 1 2
1
GD B1 1 60 CB
DR
GD CB Ø1
CB
3
CB
3 CB3 Ø16
0
1 0
AI
C CB CB3
10
Ø1
60 3
CB
NA
0
Ø1
GD
6 Ø1
27.697
CB3 Ø160
B1 10 60 1 Ø1 1 60
26.98
CB3 CB3
GE
C 60 Ø1 CB 3 3 Ø1
1
Ø1 CB CB3 24.916
60 CB CB B3 CB3 Ø
N
1 Ø1 1 Ø1 60 B3 CB3
CA
28.264 C 160 C
CB 60 CB
1 CB Ø1 C B 3
S
NA
1 1
23.42
CB3
Ø1 CB 60 6 0
CB CB
3
CB
3 CB3 CB3 Ø160
L-
21.398
1 1 60 Ø1 B3 3 CB3 CB1CB1
CB 1 1 CB 29.571
3
1 Ø1 B1 CB3
CB Ø1 D CB 0 CB 1 60 60
C CB3 CB1 CB1 CB1 Ø200 LOOS
60
G 110 C Ø1 STORM
GD Ø1 3 CB E
Ø1
60 1 WATE CB3
Ø1 1Ø , CB 3 CB1 Ø200
20.017
B1 1 Ø1 3 R CB1
CB IN 0 3 3 CB DRAIN CB3 Ø160 CB1 CB1 CB3 STON
GD
G1D10 CB
27.909
CB
B2 C Ø20020.092
2 C RA Ø 20
60 60 B3 Ø160 PVC SCH. 80 AGE C
ANAL-2 CB CB
3 CB3 Ø160 E
CB Ø200 RD 0
1
60 Ø 2 Ø1 Ø1 30.219 C 3 18.53 19.524
CB
Ø200
Ø1 TE 60 1
CB160 3 CB
3 OUTLET PIPE CB CB3
18.899
CB3
1 UT R. x 1 3 00
CB 3 CB3 CB3 20.38
CB Ø2
CB3
CB
18.321
G CB Ø
(TYPICAL TO CB3)
CB3
A CB3
60
. 3
YP x V 60 CB
Ø1
T 00 1 Ø1 3
CB CB
0
60 3
Ø16
6 Ø1 3 CB Ø160 Ø160
GD
2 1 00 B
B1 Ø2 C 60
CB D1 110 1 CB
0 30.314
B1 110
ST
16 Ø1 3 CAT
1
1 C G Ø C 0
CB
3 3 CB
OR
Ø B
CB 60 CB CH
0
CB3
CB3
E
Ø C Ø2 MEN
M
1 1 Ø110
1 0 3 22.294
CA
B1 CB1 CB 25.827
1
GD0 GD
6 0
1 CB Ø1 16
REFE PACITY T PON
Ø
W
1 3
CB CB 1 B1 Ø C 60 CB
AT
1
Ø1 B1 CB C10 Ø1
CB
3 Ø160 Ø160 R TO =3
DETA 0000 m -3
D
60
B3 30.60830.608 -2
ER
Ø1
1 160 C 3 2 C AL
CB
2 Ø Ø 1 B L - IL -P3 3
CB
DR
C
GD
B1 AN
CB3
60 0
1 NA 3 , CE
CB3
Ø1 B 1 16 B
22.972
C C
AI
C 3 A Ø C 13
1
00 GD0 CB1 B C
GE
N
1 Ø2 3 25.13 C E 3 30.87930.879
CB CB
AG
1 10 D1 0Ø1
1
CB AG NA
IN AI
E
C6B0 Ø1 G Ø11 B1 0 3
-2
314,18
0 3 A B R
CA
C 6
DR C
E CANAL
6 Ø1 CB D
GD
1 Ø1 10 Ø1 1 3
NA
Ø1 B1 ER
CB3
C1B60 ER CB
CB3
2 1 3
CB
1 CB CB B3
1
CB AT
L-
00 C
CB AT 0 B3
Ø2
1
1 Ø 1 C W 16 31.89931.899
C W
CB 60
Ø
CB CB
1
Ø1
60
2 M M Ø160 Ø160
OR OR
DRAINAG
60
Ø1 B1 CB ST CB
3
Ø1
ST
0
2 Ø16 1
CB3
C
CB3
907
1 B 24.286
3 B 3
CB B
0
2
C CB Ø2
0
C C 25.969
1 CB Ø200 CB4,TYP. CB
3
CB 3
WATER
1 60 B
Ø 33.47433.474C
,56
CB
1
CB
3 3
LEGEND:
0
26.347
CB 3
0
Ø2
STORM
0
2
CB CB
T-1
CB CB3
CB3
CB3
3
ER
CB 34.63534.635
3
LV
1 Ø160
CB
CB - CATCH BASIN
0
CU
6
Ø1
3 3
CB CB
3
1
CB3
3
CB3
CB
CB
CB
60
Ø1 36.171
24.688
1 60 36.171
3
Ø1 3 3
CB CB CB
CB
Ø160
Ø160 PVC SCH. 80
3
0
Ø20
4
CB
44,7
0 0
CB3
Ø2 3 OUTLET PIPE
CB3
CB
93,11
37.036
3 37.036
CB
37.131
60
60
37.691
CB
3
Ø1 (TYPICAL TO CB3) CB - 2 1000 x 1000 x 800
CB3
Ø1
CB3
STORM WATER DRAINAGE CANAL-2
3
CB
37.287 23.228
60
Ø1 38.927
C B3 Ø160 CB - 3 1000 x 1000 x 1000
60
CB3
CB3
C B3 Ø1
C B3
40.426
39.876
CB
3 23.095 GD - GUTTER DRAIN
60
CB3
CB3
Ø1
3
39.973
3
CB CB
60 Ø160
Ø1
3 3
CB
CB3
CB
CB3
60
39.521
Ø1 3
3 CB
CB39.885
60
Ø1
CB3
CB3
ST
3
54
OR
CB
40.373
CB
M
60 41.144 Ø160
W
Ø1
6,
AT
3 3
CB CB
23.98
ER
13
CB3
CB3
60 OUTLET PIPE
DR
42.633 Ø1
(TYPICAL TO CB3)
AI
3 3
CB
43.653
CB
NA
GE
60
CB3
CB3
Ø1
CA
3 3
CB CB
NA
45.295
60 Ø160
L-
Ø1 CULVERT-5
2
45.871
CB3
3 2
CB CB REFER TO DETAIL -5, CE 06 AL-
CB3
N
46.809 CA
Ø200 AGE
3 B3 AIN
DR
47.872
CB C Ø200
TER
CB3
Ø200
60 WA
CB3
Ø1 26.074
RM
3 B3 STO
CB 60
C B3 Ø160
49.064
C Ø160
Ø1 Ø160 26.658
3 Ø160 CB3
49.401
CB 3
STORM WATER DRAINAGE CANAL-2 CB
27.136
2
L-
PO
NA
B3 PRO 60 CB3
0C
CA
Ø1
36.657
Ø16
GE
STO
CB3 CB3
NA
RM
WA
AI
TER CB3
DR
GE CB3
AT
L-2
Ø160 CB3
M
OR
Ø160
CB3
ST
Ø200 CB3
34.342 Ø160
CB3
0
Ø20
51
287,04
6,5
7
ST
OR
M
W
AT
ER
345,51
DR
A IN
AG
E
CA
NA
L-
2
1102,28
240,46
5-5-37
NOTES : STORM DRAINAGE SYSTEM
1. ALL DIMENSIONS ARE IN METERS, UNLESS OTHERWISE SPECIFIED.
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
MASTER SITE DEVELOPMENT
(MECHANICAL PLAN)
FPC FPC
D - - XM02
P
MP
UP
PANEL
DUTY
RAMP
FRAME
CONTROL MEDIUM&
IRON COVER
CAST
MANHOLE
RUNGS
STEEL
STAINLESS
PUMPS
TRANSFER
P
ST
AT
IT
UN
E
AG
CK
PA
G
TIN ED C
IS OS V %
EX OP A/P .27
PR /SW =2 IED P
E .D UR ST
LP ,V B
./X m CT AT
CU 180 IRE NIT
2
m ,L= E D E U
0m ) BL AG
30 2(E CA K
Cx mm .V. PAC
3.5185 V K G
x 1K TIN
+1 IS
EX
OM
FR
G L
IN NE
HT PA
IG LP
/L ED OM
LP
OS FR G
OP G TIN
PR IRIN IGH
L
N W OR
IO F
AT
ST
ER
W
PO
G
TIN
IS
VC EX
A/P
W D N
E/S RIE
LP m BU ATIO
./X 25 T ST
CU = EC R
ED 2 ) ,L DIR WE
OS mm 2(E E PO
OP 35 m BL G
PR .5Cx 16m . CA TIN
3 1x K.V XIS
+ V E
1K ROM
F
ING
P HT
MP LI
G
/
NEL
LP
UP
PA TY
OL DU E
MP
M AM
NTR
RA
IU FR
&
CO MED R
ON
CO
VE
IR
ST OLE
CA H
MAN
S
NG
L RU
EE
ST
SS
NLE
AI
ST
MPS
PU
ER
SF
AN
TR
P
ST ON 5-5-37
AT T I
IT A
U N ST
E ER STORM DRAINAGE SYSTEM
AG OW
ACK P
G
P
ING
TI
N S ED C IST
S O /PV 7% X MASTER SITE DEVELOPMENT
EX
I P
O A .2 P VC E
PR /SW =2 IED P A/
(ELECTRICAL PLAN)
L PE ,V.D BUR ST / SW ED ON
I
U ./X 0m ECT T AT L PE U R TI
C 8 I m B TA
m
2 L=1 DIR UN
U ./X 25 CT S FPC FPC
0 m E) , BLE GE D C ,L= RE ER
30 m2( CA CK
A
S E m E) DI W
2
x
5C 5m K.V PA
. PO 5m 2( LE PO
.
3 18 V NG O 3 m B G
1 x 1K TI PR .5Cx 16m . CA TIN
+ IS 3 1x K.V XIS JANUARY 2019
EX + V E NTS
OM K
1 RO M
F R F
D - - XL01
GENERAL NOTES :
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE
NOTED.
2. ELEVATIONS ARE IN METERS.
3. THIS DESIGN DRAWING IS SUBJECT FOR ANY REVISIONS
SIDEWALK TO SUIT THE ACTUAL SITE CONDITION DURING
CONSTRUCTION AND TO BE INCORPORATE IN THE
CONTRACTORS SHOP DRAWINGS.
EXIT
ENTRY
FINISHES :
FLOOR :
400x400x09mm UNGLAZED CERAMIC TILES REFERENCE DRAWINGS
SKIRTING : 100 mm HIGH BROWN PAINT
WALL : DWG. NO. DRAWING TITLE
PLASTER / PAINTED
SP01 GENERAL SITE PLAN
CEILING :
PLASTER AND PAINT AR02 ARC PLAN AND ELEVATION
AR03 ARC ELEVATION AND SECTION
GUARD HOUSE
1 SECTION 2 SECTION
- -
GENERAL NOTES :
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE
1 2 7 8 NOTED.
2. ELEVATIONS ARE IN METERS.
725 10150 5400 10150 725 3. THIS DESIGN DRAWING IS SUBJECT FOR ANY REVISIONS
TO SUIT THE ACTUAL SITE CONDITION DURING
50 50 50 50 CONSTRUCTION AND TO BE INCORPORATE IN THE
CONTRACTORS SHOP DRAWINGS.
750 650
750 650
REFERENCE DRAWINGS
DWG. NO. DRAWING TITLE
SP01 GENERAL SITE PLAN
AR02 ARC PLAN AND ELEVATION
AR03 ARC ELEVATION AND SECTION
1 2 3 4 5 6 7 8
11200 3300 11200
10150 1050 750 1800 750 1050 10150
200 200 ROOF DRAIN DETAIL
A
350
2213
B
5800
1500
C A
A AR01
2087
AR01
D
350
B
AR01
GENERAL NOTES :
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE
NOTED.
2. ELEVATIONS ARE IN METERS.
3. THIS DESIGN DRAWING IS SUBJECT FOR ANY REVISIONS
TO SUIT THE ACTUAL SITE CONDITION DURING
1 2 7 8 CONSTRUCTION AND TO BE INCORPORATE IN THE
725 10150 5400 10150 725 CONTRACTORS SHOP DRAWINGS.
50 50 50 50
775 1550 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1550 775
750
850
A
100
1500
900
900
1500
2700
2700
5800
900
900
A
1500
900
900
A AR01 REFERENCE DRAWINGS
1400 2700 2700 2700 2700 1400
AR01
1500
DWG. NO. DRAWING TITLE
SP01 GENERAL SITE PLAN
100
850
750
AR02 ARC PLAN AND ELEVATION
AR03 ARC ELEVATION AND SECTION
775 775 1525 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1525 775 775
B
AR01
1 2 7 8
ROOF DRAIN DETAIL
850
A
100
2175 2175
900
900
5800
900
900
A
900
900
ST04
2700 2700 2700 2700
2400
2400
D
100
850
GUARD HOUSE&GATE
ROOF&CELLING
GENERAL NOTES :
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE
NOTED.
2. ELEVATIONS ARE IN METERS.
3. THIS DESIGN DRAWING IS SUBJECT FOR ANY REVISIONS
TO SUIT THE ACTUAL SITE CONDITION DURING
CONSTRUCTION AND TO BE INCORPORATE IN THE
CONTRACTORS SHOP DRAWINGS.
REFERENCE DRAWINGS
DWG. NO. DRAWING TITLE
SP01 GENERAL SITE PLAN
AR02 ARC PLAN AND ELEVATION
AR03 ARC ELEVATION AND SECTION
SECTION B-B
AR01
1 2 7 8
725 10150 5400 10150 725
50 50 50 50
750 650
SEE ROOF DRAIN DETAILS.
SECTION A-A
AR01
GUARD HOUSE&GATE
SECTIONS
GENERAL NOTES :
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE
NOTED.
2. ELEVATIONS ARE IN METERS.
3. THIS DESIGN DRAWING IS SUBJECT FOR ANY REVISIONS
TO SUIT THE ACTUAL SITE CONDITION DURING
CONSTRUCTION AND TO BE INCORPORATE IN THE
CONTRACTORS SHOP DRAWINGS.
REFERENCE DRAWINGS
DWG. NO. DRAWING TITLE
SP01 GENERAL SITE PLAN
AR02 ARC PLAN AND ELEVATION
AR03 ARC ELEVATION AND SECTION
GUARD HOUSE&GATE
SECTIONS
GENERAL NOTES :
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE
NOTED.
2. ELEVATIONS ARE IN METERS.
3. THIS DESIGN DRAWING IS SUBJECT FOR ANY REVISIONS
TO SUIT THE ACTUAL SITE CONDITION DURING
CONSTRUCTION AND TO BE INCORPORATE IN THE
CONTRACTORS SHOP DRAWINGS.
1 2 7 8
725 10150 5400 10150 725
50 50 50 50
775 1550 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1550 775
REFERENCE DRAWINGS
DWG. NO. DRAWING TITLE
SP01 GENERAL SITE PLAN
750
850
A
100
1500
900
900
1500
2700
2700
5800
900
900
1500
900
900
1400 2700 2700 2700 2700 1400
1500
100
850
750
775 775 1525 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1525 775 775
ROOF DRAIN DETAIL
B
AR01
GUARD HOUSE&GATE
CELLING PLAN STRRUCTURE
GENERAL NOTES :
EX
IST
ING
AS
PH
EXI
A
STIN
LT
RO
GE
EXI
AD
STI
ART
REFERENCE DRAWINGS
NG
HC
15, M TH
FR
ASP
ANA
000
O
HAL
ME EXIS
TA
TER TIN
E
CCE
9150
EXI
SA G
O AD
R
LT
WA
SS
ELE
PH
CTR
AS
ICAL
Y
LY
RO
OPE
RA
T
ED
BA
AD
RR
IE
R
250
PROPOSED HYDROLIC ROAD BLOCKER
+0.3 RD
(TYPICAL TO 2)
GU OM
RO
0
A
250
ELE
CTR
ICA
AR0
LLY
1
B
OPE
RA
TED
BA
AD
R
RIE
PRO 2- 150
R
R O Y
N CE T R
TRA EN
(
POS 0mm
N
B
E
ST03
S E D
O
ED
P
P RO
BOX 1000m
R3000
x
9150
CUL m )
NOT TO SCALE
VER
TS
SIDEWALK
400x400x50 thk. concrete tiles
+ 150x350x500mm Curb Stone.
A (TYPICAL)
ST02
EX
C
4
ST0
IS TIN
GA
SP
EXI
ENTRANCE GATE
EXI
HA
STI
STIN
GUARD HOUSE
LT
D
ST05
1100
NG
RO
GE
A
ASP
D
ART
HAL
FAC ipe
HC
TA
ANA
CCE
NOTES :
L
2. ALL OTHER DIMENSIONS, NOT SHOWN ABOVE MUST BE REFERRED TO THE LATEST ARCHITECTURAL SITE PLAN
3. ALL REQUIRED LEVELS, NOT SHOWN ABOVE MUST BE VERIFIED & REFLECTED IN THE CONTRACTOR'S SHOP DRAWINGS
RO
4. THE WATER FLOW DIRECTION MUST BE VERIFIED ON SITE TO SUIT THE ACTUAL CONDITION ABOUT THE LEVELS.
1100
SPECIAL NOTE
1. OTHER STRUCTURAL DETAILS NOT SHOWN IN THESE ENGINEERING
DRAWING MUST BE INCLUDED IN THE CONTRACTOR'S SHOP DRAWINGS.
1. ALL DIMENSIONS AND SIZES ARE IN MILLIMETERS UNLESS 1. ALL CONCRETE WORKS SHALL BY CARRIED OUT IN ACCORDANCE WITH THE SHOTCRETE
PROJECT SPECIFICATIONS. 1. OR GROUT 16. SLAB REINF. STEEL BAR
NOTED OTHERWISE. TOP LAYER W/O HOOK
2. ALL COORDINATES ARE IN MILLIMETERS UNLESS NOTED OTHERWISE. 2. ALL CONCRETE STRUCTURES SHALL MEET THE REQUIREMENTS SET FORTH IN ACI
CODE 318M-89/318RM-89, REVISED '95 METRIC EDITION. 2. NEW 17. SLAB REINF. STEEL BAR
3. ALL ACTUAL ELEVATIONS BASED ON THE SET DATUM ARE IN CONCRETE
METERS UNLESS NOTED OTHERWISE. 3. ACI CODE OF PRACTICE SHALL APPLY TO ALL CONCRETE QUALITIES UNLESS BOTTOM LAYER W/O HOOK
OTHERWISE SPECIFIED.
4. ALL ASSUMED ELEVATIONS BASED FROM ANY STRUCTURAL LEVEL ARE 3. BLINDING 18. SLAB REINF. STEEL BAR
4. COMPRESSIVE STRENGTH OF CONCRETE AT 28 DAYS USING CYLINDERS SAMPLED CONCRETE TOP LAYER W/ HOOK
IN MILLIMETERS UNLESS NOTED OTHERWISE.
AND CURED IN ACCORDANCE WITH ASTM C192 AND TESTED IN ACCORDANCE
5. DRAWINGS SHALL NOT BE SCALED. WITH ASTM C39 SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED 4. PRECAST 19. SLAB REINF. STEEL BAR
CONCRETE BOTTOM LAYER W/ HOOK
6. ALL STRUCTURAL WORKS AND MATERIALS SHALL CONFORM TO a. LEVELING OR BLINDING CONCRETE, f'c= 21 MPa.
THE REQUIREMENTS OF THE PROJECT SPECIFICATIONS. b. SUBSTRUCTURE CONCRETE, f'c= 30 MPa. SELECTED
5. 20. SLAB REINF. STEEL BAR
c. SUPERSTRUCTURE CONCRETE, f'c= 30 MPa. EARTH FILL
7. ALL DIMENSIONS AND CONDITIONS AFFECTING THE WORK ON SITE SHALL TOWARDS THE READER
BE VERIFIED BY THE CONSTRUCTION CONTRACTOR. 5. ALL REINFORCED STEEL BARS SHALL BE DEFORMED BILLET STEEL BAR
COMPLYING WITH ASTM 615, GRADE 60 AND WITH A SPECIFIED MINIMUM YIELD 6. SAND 21. SLAB REINF. STEEL BAR
8. WHERE THERE EXISTS CONFLICT, DISCREPANCY OR AMBIGUITY BETWEEN STRENGTH OF fy=415MPa. AWAY FROM ETHE READER
THE DRAWINGS AND THE PROJECT SPECIFICATION THE FORMER SHALL
6. ALL DEFORMED WELDED WIRE FABRIC FOR CONCRETE REINFORCEMENT SHALL HARDCORE
GOVERN AND SHALL BE RESOLVED WITH THE ENGINEER. 7.
CONFORM TO ASTM A497 OR A185 AND SHALL HAVE A MINIMUM YIELD (GRAVEL FILL) WALL REINF. STEEL BAR
9. ALL STRUCTURAL DRAWINGS SHALL BE READ IN CONJUNCTION WITH STRENGTH OF fy=415MPa. 22.
ALL OTHER RELATED ARCHITECTURAL, SEWACE, ELECTRICAL WATER SUPPLY TERRAIN
FAR FACE W/O HOOK REFERENCE DRAWINGS
7. LAPS TO REINFORCEMENT BARS OF SLABS AND BEAMS SHALL BE AS INDICATED 8.
AND MECHANICAL DRAWINGS. SURFACE
ON THE RELEVANT DRAWINGS.
DWG. NO. DRAWING TITLE
8. MINIMUM LENGTH OF TENSION LAP SPLICES SHALL BE CLASS B EQUAL TO 1.5 9. COMPRESSIBLE
FILLER BOARD ST01 STANDARDS STRUCTURAL NOTES, MISCELLANEOUS
TIMES THE SQUARED OF DIAMETER (1.5XØ2). 23. WALL REINF. STEEL BAR
9. MINIMUM LENGTH OF COMPRESSION LAP SPLICES SHALL BE 50 TIMES DIAMETER FAR FACE W/ HOOK ST02 STANDARD STRUCTURAL DESIGN CRITERIA, MISCELLANEOUS
OF BAR (50XØ), BUT NOT LESS THAN 300mm. 10. INSULATION ST03 STANDARDS STRUCTURAL DETAILS, PART-1, MISCELLANEOUS
10. SPLICES SHALL BE ALTERNATELY STAGGERED AT LEAST 600mm. ST04 STANDARDS STRUCTURAL DETAILS, PART-2, MISCELLANEOUS
EARTHWORKS NOTES 11. WELDED SPLICES AND OTHER MECHANICAL CONNECTIONS SHALL CONFROM
TO AWS D1.4.
11. CMU
24. WALL REINF. STEEL BAR
NEAR FACE W/O HOOK
ST05
ISOLATED FOOTINGS, COLUMNS, GROUND FLOOR & DECK ROOF
SETTING-OUT & FRAMING PLAN
12. CEMENT SHALL BE PORTLAND CONFORMING TO ASTM C150 AND SULPHATE PLAIN CUT
12. CONSTRUCTION ISOLATED FOOTINGS & COLUMNS STRUCT'L. SCHED. & DET'LS.
RESISTING,TYPE V UNLESS OTHERWISE SPECIFIED. ST06
JOINT
13. ALL GROUTING OF FOUNDATIONS FOR EQUIPMENTS STRUCTURES SHALL BE CARRIED ST07 GROUND FLOOR GRADE BEAMS STRUCT'L. SCHED. & DET'LS.
WATERPROOFING 25. WALL REINF. STEEL BAR
1. STRUCTURALL FILL MATERIALS SHALL BE PLACED UNDER ALL SHALLOW OUT IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS CONTRACTOR TO PROVIDE 13. ST08 DECK ROOF SUSPENDED BEAMS STRUCT'L. SCHED. & DET'LS.
MEMBRANE NEAR FACE W/ HOOK
FOUNDATIONS, PAVED AREAS AND GRADE SLABS IF UNSUITABLE BEARING NON-SHRINK GROUT UNLESS OTHERWISE SPECIFIED.
ST09 ENTRANCE SHADE SPACE FRAME SYSTEM PLAN & SECTION
MATERIALS ARE ENCOUNTERED AT THE REQUIRED SUBGRADE ELEVATIONS 14. MAXIMUM SIZE OF AGGREGATES SHALL BE 20mm.
14. FFE 26. DIAMETER OF BAR
2. ALL STRUCTURAL FILL MATERIALS SHALL BE COMPACTED IN LAYERS NOT 15. AIR ENTRAINING ADMIXTURES SHALL CONFORM TO ASTM C260 AND SUBJECT TO
EXCEEDING. 200mm LOOSE DEPTH AND SHALL MEET THE PEQUIRED COMPACTED PRIOR APPROVAL BY THE ENGINEER.
27. c CENTER TO CENTER
DENSITY NOT LESS THAN 95% OF MAXIMUM DRY DENSITY AS DETERMINED 16. THE FOLLOWING MINIMUM CONCRETE PROTECTION CLEAR COVER SHALL BE 15. SSE SPACING
BY ASTM D1557 OR EQUIVALENT. PROVIDED FOR REINFORCEMENT UNLESS OTHERWISE NOTED.
3. ALL EARTHWORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE PROJECT a. SUBSTRUCTURE
(FOOTING, COLUMNS, GRADE BEAMS, RETAINING WALLS, GRADE SLABS,
SPECIFICATIONS. DUCT BANKS, ETC.)
4. THE ASSUMED NET ALLOWABLE PRESSURE OF SOIL IS 150 kPa a1. PERMANENTLY CAST AGANST EARTH=70mm
a2. CAST AGAINST FORMS & BLINDING=40mm
5. THESE NOTES ARE TO BE READ IN CONJUNCTION WITH THE SOIL
INVESTIGATION REPORT AT SITE PRIOR TO CONSTRUCTION.
b. SUPERSTRUCTURE
B1. COLUMNS AND BEAMS=40mm
B2. SLABS, WALLS, JOIST, ETC=20mm
ABBREVIATION NOTES
17. ALL EXPOSED EDGES OF CONCRETE MEMBERS SHALL HAVE A CHAMFER OF 25mm.
18. PRIOR TO PLACING OF CONCRETE, IT SHALL BE VERIFIED BY THE CONSTRUCTION
43. RC-REINFORCED CONCRETE.
MASONRY WORKS NOTES CONTRACTOR THAT ALL EXMBEDDED ITEMS SUCH AS DUCTS, ANCHOR BOLTS,
PIPING, PIPE SLEEVES, CONDUITS, AND ELECTRICAL, BOXES ARE IN PLACE AND
SECURELY FASTENED AND IN ACCORDANCE WITH THE ELECTRICAL, MECHANICAL,
1. BB-BOND BEAM.
2. B1-BEAM MARK.
3. BLDG-BUILDING.
44.
45.
46.
SJ-SEPARATION JOINT.
S1-SLAB MARK.
SHT-SHEET.
INSTRUMENTATION, PIPING, CIVIL, AND EQUIPMENT MANUFACTURERS. 4. BM-BEAM.
5. BTM-BOTTOM. 47. STL-STEEL.
19. TWO COATS OF EPOXY BITUMINOUS COATING MATERIAL SHALL BE APPLIED TO 48. STIR-STIRRUPS.
THE EXTERNAL SURFACE OF CONCRETE CONTACTING SOIL EXCLUDING BOTTOM 6. COL-COLUMN.
SURFACES AND SURFACES OF LEVELING,(BLINDING) CONCRETE. 7. CONT-CONTINUOUS. 49. SSE-STRUCTURAL SLAB ELEVATION
1. ALL CONCRETE MASONRY UNITS SHALL CONFORM TO THE PROJECT SPECIFICATIONS. 8. COV-COVER. 50. STD-STANDARD.
20. ALL BOTTOM SURFACES OF CONCRETE CASTS AGAINST AND PERMANENTLY IN
CONTACT WITH GROUND SHALL BE UNDERLAIN BY POLYETHYLENE SHEETS 9. CYL-CYLINDER. 51. SECT-SECTION.
2. ALL LOAD BEARING HOLLOW CONCRETE BLOCKS SHALL CONFORM TO ASTM C98. 10. CONJ-CONTROL OR CONTRACTION JT. 52. TB-TIE BEAM.
(VAPOUR BARRIER) AS INDICATED ON DRAWINGS.
3. ALL NON-LOAD BEARING HOLLOW CONCRETE BLOCKS SHALL CONFORM TO ASTM C129. 11. C1-COLUMN MARK. 53. THK-THICK.
21. MAXIMUM WATER CEMENT RATIO OF 0.40 SHALL BE REQUIRED FOR CONCRETE 54. THKS-THICKNESS.
EXPOSED TO FREEZING, THAWING SULPHATE SOILS OR WATERS. 12. c-CENTER TO CENTER SPACING
13. CJ-CONSTRUCTION JOINT. 55. TYP-TYPICAL. 4
22. CONSTRUCTION JOINT SHALL BE REQUESTED IN WRITING FOR APPROVAL TWO 14. CONC-CONCRETE. 56. W-WALL.
WEEKS BEFORE THEIR NEED. 15. DET-DETAIL. 57. W/-WITH 3
23. EXPANSION JOINT FILLER SHALL BE PREMOULDED, NON-EXTRUDING TYPE CONFORMING 16. DIA-DIAMETER. 58. WWF-WELDED WIRE FABRIC 2
3. ALL FRAMING MEMBERS SHALL BE SHOP FABRICATED FOR BOLTED FIELD ASSEMBLY,
35. NO.-NUMBER.
36. NTS-NOT TO SCALE. 5/5/37
UNLESSS OTHERWISE NOTED ON ERECTION DRAWING 37. PLT-PLATE.
38. P1-PEDESTAL MARK.
4. ALL FRAMING MEMBERS SHALL BE CLEANED BY POWER OR HAND-WIRE BRUSHING TO 39. PDTL-PEDESTAL.
REMOVE ALL DIRT GREASE, OIL, LOOSE MILL SCALE, WELD SLAG, FLUX DEPOSIT AND 40. RW-RETAINING WALL.
ENTRANCE GATE
OTHER FOREIGN MATTER, AND GIVEN ONE SHOP COAT OF RED OXIDE AIR DRYING, 41. REINF-REINFORCEMENT.
PHENOL MODIFIED ALKYD RESIN PRIMER. PRIMER SHALL EQUAL OR EXCEED THE END 42. RSB-REBAR OR REINFORCED STEEL BAR GUARD HOUSE
PERFORMANCE REQUIREMENTS OF U.S.FEDERAL SPECIFICATION TTP-636
STANDARD STRUCTURAL NOTES
MISCELLANEOUS
AFG AFG
3. UNIFORM BUILDING CODE, 1997 3. SEISMIC ZONE FACTOR, Z= 0.15, FOR ZONE 2A
4. MINIMUM DESIGN LOADS FOR BUILDING & OTHER STRUCTURES. 4. OVER STRENGTH FACTOR, R=5.5
1. SAP
1. WIND VELOCITY, V= 150 kph
REFERENCE DRAWINGS
2. PROKON
2. OCCUPANCY III, Iw= 1.15 DWG. NO. DRAWING TITLE
2. ACAD 2008 ST01 STANDARDS STRUCTURAL NOTES, MISCELLANEOUS
3. EXPOSURE C, kz= 0.85
ST02 STANDARD STRUCTURAL DESIGN CRITERIA, MISCELLANEOUS
ST03 STANDARDS STRUCTURAL DETAILS, PART-1, MISCELLANEOUS
4. BASIC PRESSURE, qz= 1.33 kPa ST04 STANDARDS STRUCTURAL DETAILS, PART-2, MISCELLANEOUS
ISOLATED FOOTINGS, COLUMNS, GROUND FLOOR & DECK ROOF
SERVICE DEAD LOAD 5. WIND FORCE RESISTING, GCpi= 0.18, PRESSURE
ST05
SETTING-OUT & FRAMING PLAN
GCpi=-0.18, SUCTION ST06 ISOLATED FOOTINGS & COLUMNS STRUCT'L. SCHED. & DET'LS.
ST07 GROUND FLOOR GRADE BEAMS STRUCT'L. SCHED. & DET'LS.
ST08 DECK ROOF SUSPENDED BEAMS STRUCT'L. SCHED. & DET'LS.
1. REINFORCED CONCRETE = 24.00 kN/m3 ST09 ENTRANCE SHADE SPACE FRAME SYSTEM PLAN & SECTION
6. LIGHTWEIGHT CONCRETE & WATERPROOFING = 1.50 kPa WITH ASTM C39 SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED
SERVICE LIVE LOAD COMPLYING WITH ASTM 615, GRADE 60 AND WITH A SPECIFIED MINIMUM YIELD
STRENGTH, fy=415MPa.
ENTRANCE GATE
GUARD HOUSE
STANDARD STRUCTURAL DESIGN CRITERIA
MISCELLANEOUS
AFG AFG
6. INSIDE DIAMETER OF BEND FOR STIRRUPS AND TIES SHALL NOT BE LESS THAN
STANDARD HOOKS FOR STIRRUPS, TIE & HOOPS
(4 x ØREBAR), FOR Ø16 REBAR AND SMALLER.
FOR THE REBARS LARGER THAN Ø16 , THE DIAMETER OF BEND SHALL BE IN ACCORDANCE
WITH TABLE-1 AS SHOWN BELOW.
TABLE - 1
REBAR SIZE MINIMUM DIAMETER OF BEND
Ø10 THRU Ø25 6 x ØREBAR
REFERENCE DRAWINGS
Ø28 THRU Ø32 8 x ØREBAR DWG. NO. DRAWING TITLE
ST01 STANDARDS STRUCTURAL NOTES, MISCELLANEOUS
ST02 STANDARD STRUCTURAL DESIGN CRITERIA, MISCELLANEOUS
ST03 STANDARDS STRUCTURAL DETAILS, PART-1, MISCELLANEOUS
ST04 STANDARDS STRUCTURAL DETAILS, PART-2, MISCELLANEOUS
ISOLATED FOOTINGS, COLUMNS, GROUND FLOOR & DECK ROOF
ST05
SETTING-OUT & FRAMING PLAN
ST06 ISOLATED FOOTINGS & COLUMNS STRUCT'L. SCHED. & DET'LS.
ST07 GROUND FLOOR GRADE BEAMS STRUCT'L. SCHED. & DET'LS.
ST08 DECK ROOF SUSPENDED BEAMS STRUCT'L. SCHED. & DET'LS.
ST09 ENTRANCE SHADE SPACE FRAME SYSTEM PLAN & SECTION
- TYPICAL REINFORCED STEEL BARS HOOKS, BENDS & BASIC DEVELOPMENT LENGTH
-
H/4<50
WWF, TYP.
70 MIN.
_
KEYED CUT KEYED CUT
CRACK INDUCER CRACK INDUCER
H
H
25, MIN.
300, MIN. 300, MIN.
- CONSTRUCTION JT. - CONTROL OR CONTRACTION JOINT - CONSTRUCTION JT. - CONTROL OR CONTRACTION JOINT
- - - -
4
3
SEALANT SEALANT SEALANT
SEALANT 2
JOINT FILLER JOINT FILLER JOINT FILLER 1 GENERAL REVISION JAN., 2019
JOINT FILLER
H/3<50
H/3<50
MAY, 2014
H/4<50
Ø16 DOWEL REBAR Ø16 DOWEL REBAR 12 MIN. 0 PRELIMINARY ISSUE
H/3<50 10 MIN.
_
_
WITH ASPHALT COAT WITH ASPHALT COAT REVISIONS SUBJECT DATE
_
H
H
H
100, MIN.
COMPRESSIBLE COMPRESSIBLE
300, MIN. 300, MIN.
MATERIAL AT MATERIAL AT
END OF CAP END OF CAP
100,
300,MIN.
MIN.
- ISOLATION OR SEPARATION JT. - EXPANSION JT. - ISOLATION OR SEPARATION JT. - EXPANSION JT.
- - - - 5/5/37
- _
HEAVY DUTY CONCRETE JOINTS FOR H>200 - LIGHT DUTY CONCRETE JOINTS FOR H<200 ENTRANCE GATE
- -
GUARD HOUSE
STANDARD STRUCTURAL DETAILS, PART-1
MISCELLANEOUS
SSE
ROOF SLAB
(SEE FRAMING PLAN)
2 Ø12, TYP.
Ø10 c250, TYP. ISOLATED FOOTINGS, COLUMNS, GROUND FLOOR & DECK ROOF
400
ST05
2 Ø12, TYP. SSE SETTING-OUT & FRAMING PLAN
ST06 ISOLATED FOOTINGS & COLUMNS STRUCT'L. SCHED. & DET'LS.
SLAB THICNESS
ST07 GROUND FLOOR GRADE BEAMS STRUCT'L. SCHED. & DET'LS.
2Ø16, TYP. ST08 DECK ROOF SUSPENDED BEAMS STRUCT'L. SCHED. & DET'LS.
2Ø16, TYP. ST09 ENTRANCE SHADE SPACE FRAME SYSTEM PLAN & SECTION
(SEE FRAMING PLAN & SCHEDULE) (SEE FRAMING PLAN & SCHEDULE)
4Ø16, TOTAL TOP & BTM., TYP.
BARS "A" = HALF THE AREA OF
REINF. CUT BY THE OPENING TO
BE PLACED ON EACH SIDE
(MIN. OF 4Ø14) X SECTION
- PLAN -
-
VAR.
VAR.
150, MIN.
0 PRELIMINARY ISSUE MAY, 2014
H, HEIGHT
150, MIN.
SEALANT
REVISIONS SUBJECT DATE
VARIES
SSE
SLAB THICKNESS
100
100 100
100 100
SEE SCH.
SEE SCH. ROOF BEAM & SLAB 5/5/37
200 THK. ORDINARY CMU WALL, FOR CLOSURE (SEE FRAMING PLAN)
50 THK. PLAIN LEAN CONCRETE
100 THK. PLAIN LEAN CONCRETE
.20 THK. POLYETHYLENE SHEETS, VAPOUR BARRIER
.20 THK. POLYETHYLENE SHEETS, VAPOUR BARRIER ENTRANCE GATE
2 COATS OF BITUMINOUS MAT'LS, DAMP PROOFING
2 COATS OF BITUMINOUS MAT'LS, DAMP PROOFING
.20 THK. POLYETHYLENE SHEETS, VAPOUR BARRIER
.20 THK. POLYETHYLENE SHEETS, VAPOUR BARRIER GUARD HOUSE
HARDCORE PERCOLATION LAYER, (GRANULAR MARL)
HARDCORE PERCOLATION LAYER, (GRANULAR MARL)
95 % COMPACTED STRUCT'L. FILL MAT'LS., TYP.
STANDARD STRUCTURAL DETAILS, PART-2
95 % COMPACTED STRUCT'L. FILL MAT'LS., TYP. MISCELLANEOUS
- - INTERIOR WALL, BEAM & GRADE SLAB SECTION - TYPICAL PARAPET WALL WITH ISOLATION JT.
EXTERIOR WALL, BEAM & GRADE SLAB SECTION AFG AFG
- - -
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
11200 3300 11200 11200 3300 11200
200 10150 1050 750 1800 750 1050 10150 200 200 10150 1050 750 1800 750 1050 10150 200
BUILDING ORIENTATION
R8
50
1750
1750
R8
50
C2 C2 GB1 C2 C2 C2 C2 RB1 C2 C2 1. FOR BUILDING ORIENTATION, REFER TO THE LATEST SITE PLAN.
CN ( 200x400 ) CN ( 200x700 )
A A
350
350
350
350
100
100
( 200x400 )
FFE FFE
RB2
RB2
GB2
GB2
2213
2213
2213
2213
(+300) (+VAR.)
( 200x400 )
( 200x400 )
C1 C1 Ø12 c200, T
GB3
RB3
FGE, ASPHALT PAVEMENT FGE, ASPHALT PAVEMENT FGE, ASPHALT PAVEMENT FGE, ASPHALT PAVEMENT
5800
5800
GB3
RB3
1500
1500
1500
1500
Ø12 c200, B
( 000 ) ( 000 ) ( 000 ) ( 000 )
C C1 C1 C S1
( 200x400 )
( 200x400 )
GB2
GB2
2087
2087
2087
2087
(200)
RB2
120 THK. GRADE SLAB, TYP. 120 THK. GRADE SLAB, TYP.
RB2
WITH Ø8 c200x200 WWF OR EQUIV. WITH Ø8 c200x200 WWF OR EQUIV.
D D REFERENCE DRAWINGS
100
100
350
350
350
350
C2 CN GB1 CN C2 RB1
C2 C2 C2 C2 ( 200x700 ) C2 C2
1750
1750
( 200x400 )
DWG. NO. DRAWING TITLE
R8
50
50
150x500 PARAPET WALL, ( (+3700) ST01 STANDARDS STRUCTURAL NOTES, MISCELLANEOUS
1300 1300
WITH Ø10 c250, VERT. REBARS & 3 Ø10, HORZ. REBARS
ST02 STANDARD STRUCTURAL DESIGN CRITERIA, MISCELLANEOUS
ST03 STANDARDS STRUCTURAL DETAILS, PART-1, MISCELLANEOUS
WFE, WALKWAY
(+150) ST04 STANDARDS STRUCTURAL DETAILS, PART-2, MISCELLANEOUS
ISOLATED FOOTINGS, COLUMNS, GROUND FLOOR & DECK ROOF
FGE, ASPHALT PAVEMENT ST05
SETTING-OUT & FRAMING PLAN
( 000 )
ST06 ISOLATED FOOTINGS & COLUMNS STRUCT'L. SCHED. & DET'LS.
ST07 GROUND FLOOR GRADE BEAMS STRUCT'L. SCHED. & DET'LS.
ST08 DECK ROOF SUSPENDED BEAMS STRUCT'L. SCHED. & DET'LS.
NOTE : NOTE :
ST09 ENTRANCE SHADE SPACE FRAME SYSTEM PLAN & SECTION
1. FOR OTHER DETAILS NOT SHOWN, REFER TO AR-01 1. FOR OTHER DETAILS NOT SHOWN, REFER TO AR-01
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
11200 3300 11200 11200 3300 11200
200 10150 1050 750 1800 750 1050 10150 200 200 10150 1050 750 1800 750 1050 10150 200 4
3
2
1 GENERAL REVISION JAN., 2019
100 850 100 850 850 100 850 100 0 PRELIMINARY ISSUE MAY, 2014
400 400
1000100
1000100
1000100
1000100
C2 C2
100 100
C2 C2
200 200 REVISIONS SUBJECT DATE
100
100 100
CN
400
CN
A A
350
350
350
350
350
350
100
100
C2 C2 CN CN C2 C2
FN FN (Ø500) (Ø500) (200x200) (200x200) (Ø500) (Ø500)
2213
2213
2213
2213
(800x800x400) (800x800x400)
F2 F2 F2 F2
100
100
650
250
250
B C1 C1 B C1
(200x500)
C1
(200x500)
F1 F1
5800
5800
1500
1500
1500
1500
(2800x1000x400) (2800x1000x400) 100 100
250
250
C C1 C1 C C1
(200x500)
C1
(200x500)
F2 F2 F2 F2
2087
2087
2087
2087
(1800x1800x600) (1800x1800x600) (1800x1800x600) (1800x1800x600)
FN FN
(800x800x400) (800x800x400) C2
(Ø500)
C2
(Ø500) (200x200)
CN CN
(200x200) (Ø500)
C2 C2
(Ø500)
5/5/37
D D
100
100
350
350
350
350
350
350
400
1001000
1001000
CN
1001000
1001000
100
C2 C2 CN C2 C2 200 200
100 100
200 200
100
400
100
400
ENTRANCE GATE
100 850 100 850 850 100 850 100
GUARD HOUSE
ISOLATED FOOTINGS, COLUMNS
GROUND FLOOR & DECK ROOF
SETTING-OUT & FRAMING PLANS
F2 2000 2000 100 1800 1800 600 12 Ø16 c154 12 Ø16 c154 3 Ø16 3 Ø16 SAME AS COL. SAME AS COL. 800 -800, VERIFY -1500, VERIFY
FN 1000 1000 100 800 800 400 5 Ø14 c175 5 Ø14 c175 2 Ø12 2 Ø12 SAME AS COL. SAME AS COL. 800 -1000, VERIFY -1500, VERIFY
JOINT HOOPS
(2 TIES/SET) JOINT HOOPS = Ø10 c150 ST08 DECK ROOF SUSPENDED BEAMS STRUCT'L. SCHED. & DET'LS.
(1 TIE/SET)
(SEE SCHEDULE)
COLUMN HOOPS =5 Ø8 c150 ST09 ENTRANCE SHADE SPACE FRAME SYSTEM PLAN & SECTION
H, HEIGHT
(2 TIES/SET)
JOINT HOOPS = Ø8 c150
(2 TIES/SET)
100
800
COLUMN HOOPS
DOWEL REBARS =8 Ø16 DOWEL REBARS =8 Ø16 300 DOWEL REBARS =4 Ø14
+250
COLUMN HOOPS =5 Ø8 c150 COLUMN HOOPS =5 Ø8 c150 COLUMN HOOPS = Ø8 c200
(2 TIES/SET) (2 TIES/SET) (1 TIE/SET)
JOINT HOOPS = Ø8 c150 JOINT HOOPS = Ø8 c150 JOINT HOOPS = Ø8 c200
SSE FOOTINGS TOP (2 TIES/SET) (2 TIES/SET) (1 TIE/SET)
-800, VER. COLUMN
LATERAL TIES
300 300 300
-1500, VER.
Ø500
_ > 50 x ØREBAR
(SEE SCHEDULE)
200
200
COLUMN HOOPS
SSE 4
Ld
GRADE BEAMS 3
50
2
(SEE SCHEDULE)
H, HEIGHT
1 GENERAL REVISION JAN., 2019
LEVELING CONCRETE OUTLINE
COLUMN OR PEDESTAL 0 PRELIMINARY ISSUE MAY, 2014
E-CANTILEVER SHORT REBARS SEE SCHED.
A-SHORT BOTTOM REBARS
REVISIONS SUBJECT DATE
VAR. 50
F-CANTILEVER LONG REBARS
B-LONG BOTTOM REBARS
GROUND BEAM
(SEE SCHED.)
(SEE SCHEDULE)
T, THICKNESS
100
25 xØBAR
.20 THK. POLYETHYLENE SHEETS
- 300, TYP.
WIDTH, W, ( SEE SCHED. )
100
GROUND BEAM GROUND BEAM 5/5/37
(SEE SCHED.) (SEE SCHED.)
GROUND BEAM
(SEE SCHED.)
AFG AFG
- FRAMING PLAN A SECTION THRU COLUMN
- -
GB2 200 400 3 Ø14 - 3 Ø14 - - - Ø8 c200 Ø8 c200 1&3 RIGHT & LEFT END CONTINUOUS +250
GB3 200 400 2 Ø14 - 3 Ø14 - - - Ø8 c200 Ø8 c200 2 BOTH ENDS CONTINUOUS +250
REFERENCE DRAWINGS
DWG. NO. DRAWING TITLE
ST01 STANDARDS STRUCTURAL NOTES, MISCELLANEOUS
ST02 STANDARD STRUCTURAL DESIGN CRITERIA, MISCELLANEOUS
ST03 STANDARDS STRUCTURAL DETAILS, PART-1, MISCELLANEOUS
ST04 STANDARDS STRUCTURAL DETAILS, PART-2, MISCELLANEOUS
ISOLATED FOOTINGS, COLUMNS, GROUND FLOOR & DECK ROOF
L/3 L/3 COMP. LAP L/3 L/3 ST05
L/3 L/3 L/3 L/3 SETTING-OUT & FRAMING PLAN
L/5 COMP. LAP COMP. LAP L/5
ST06 ISOLATED FOOTINGS & COLUMNS STRUCT'L. SCHED. & DET'LS.
D C D
C D C D C ST07 GROUND FLOOR GRADE BEAMS STRUCT'L. SCHED. & DET'LS.
C C
S ST08 DECK ROOF SUSPENDED BEAMS STRUCT'L. SCHED. & DET'LS.
H
S S
H
H
B ST09 ENTRANCE SHADE SPACE FRAME SYSTEM PLAN & SECTION
B B
A L/4
L/4
L/7
A A L/7
L/5 L/5
L/3 OR 1.5xLc
H
B
A
L/7
A L/7
COMP. LAP
L/5
TYPE 4
(BOTH ENDS DISCONT.) TYPE 5
(CANTILEVERED END)
VAR.
VAR.
VARIES
150, MIN.
150, MIN.
150, MIN.
H, HEIGHT
FGE SSE
50
L1/7 L1/5
L1/4 L1/2 L1/4 L2/4 L2/2 L2/4 L3/4
ZONE-1 ZONE-2 ZONE-1 ZONE-1 ZONE-2 ZONE-1 ZONE-1
AFG AFG
- TYPICAL GRADE BEAM CROSS SECTION - TYPICAL GRADE BEAM LONGITUDINAL SECTION
- NTS - NTS
RB2 200 700 3 Ø16 3 Ø16, FR. RB3 2 Ø16 - 1- 2 Ø12 Ø10 c150 Ø10 c150 5 CANTILEVERED ENDS +3200
RB3 200 700 2 Ø16 3 Ø16 - - 1- 2 Ø12 Ø10 c150 Ø10 c150 2 BOTH ENDS CONTINUOUS +3200
REFERENCE DRAWINGS
DWG. NO. DRAWING TITLE
ST01 STANDARDS STRUCTURAL NOTES, MISCELLANEOUS
ST02 STANDARD STRUCTURAL DESIGN CRITERIA, MISCELLANEOUS
ST03 STANDARDS STRUCTURAL DETAILS, PART-1, MISCELLANEOUS
ST04 STANDARDS STRUCTURAL DETAILS, PART-2, MISCELLANEOUS
ISOLATED FOOTINGS, COLUMNS, GROUND FLOOR & DECK ROOF
ST05
L/3 L/3 COMP. LAP L/3 L/3 SETTING-OUT & FRAMING PLAN
L/5 COMP. LAP L/3 L/3 L/3 L/3 COMP. LAP L/5
ST06 ISOLATED FOOTINGS & COLUMNS STRUCT'L. SCHED. & DET'LS.
D C D ST07 GROUND FLOOR GRADE BEAMS STRUCT'L. SCHED. & DET'LS.
C D C D C
C C ST08 DECK ROOF SUSPENDED BEAMS STRUCT'L. SCHED. & DET'LS.
S
H
S S ST09 ENTRANCE SHADE SPACE FRAME SYSTEM PLAN & SECTION
H
H
B
B B
A L/4
L/4
L/7
A A L/7
L/5 L/5
L/3 OR 1.5xLc
H
B
A
L/7
A L/7
COMP. LAP
L/5
TYPE 4
(BOTH ENDS DISCONT.) TYPE 5
(CANTILEVERED END)
COLUMN L1, CLEAR SPAN COLUMN L2, CLEAR SPAN COLUMN L3, CLEAR SPAN
20 x ØBAR HOOK, TYP
PARAPET WALL, TYP. CUT TOP, E-REBARS CUT TOP, D-REBARS
150
STIRRUPS, SEE SCHED. STIRRUPS, SEE SCHED.
4
CONTINUOUS TOP, C-REBARS CONTINUOUS TOP, C-REBARS
CONTINUOUS TOP, C-REBARS CONTINUOUS TOP, C-REBARS 3
SEE AR-DWGS
PARAPET WALL, TYP. SKIN, S-REBARS, FOR H>500 SKIN, S-REBARS, FOR H>500
CUT TOP, E & D-REBARS CUT TOP, E & D-REBARS 150
2
CUT BTM., B-REBARS CUT BTM., B-REBARS
SEE AR-DWGS
L1/7 L1/5
W W
L1/4 L1/2 L1/4 L2/4 L2/2 L2/4 L2/4
ZONE-1 ZONE-2 ZONE-1 ZONE-1 ZONE-2 ZONE-1 ZONE-1
(STIRRUPS) (STIRRUPS) (STIRRUPS) (STIRRUPS) (STIRRUPS) (STIRRUPS)
DISCONT. END CONT. END CONT. END CONT. END CONT. END 5/5/37
ENTRANCE GATE
EDGE SUSPENDED BEAM INTERMEDIATE SUSPENDED BEAM - EXTERIOR SPAN SUSPENDED BEAM - INTERIOR SPAN SUSPENDED BEAM GUARD HOUSE
- - - -
NTS NTS
- NTS - NTS DECK ROOF SUSPENDED BEAMS
STRUCTURAL SCHEDULE & DETAILS
1 2 7 8
725 10150 5400 10150 725
50 50 50 50
SKYLIGHT SKYLIGHT
(AS PER MANUFACTURER'S STD. ) (AS PER MANUFACTURER'S STD. )
TYPICAL CLADDING AS SHOWN
(AS PER MANUFACTURER'S STD. )
750 650
750 650
BUILDING ORIENTATION
C2 C2 C2 C2
( SEE ST06 ) ( SEE ST06 ) ( SEE ST06 ) ( SEE ST06 )
750
850
A
100
1500
900
900
1500
2700
2700
5800
900
900
A
1500
900
900
ST04
1400 2700 2700 2700 2700 1400
1500
D
100
850
750
GIRDER AS SHOWN GIRDER AS SHOWN
4
775 775 1525 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1525 775 775
3
TYPICAL BOTTOM CHORD SPACE AS SHOWN
(AS PER MANUFACTURER'S STD. ) 2
1 GENERAL REVISION JAN., 2019
0 PRELIMINARY ISSUE MAY, 2014
REVISIONS SUBJECT DATE
PROPERTIES :
1. TOP CHORD MEMBERS = CHS Ø88.9, TO BE VERIFIED
2. BOTTOM CHORD MEMBERS = CHS Ø88.9, TO BE VERIFIED 5/5/37
3. WEB MEMBERS, ( DIAGONAL ) = Ø76.1, TOBE VERIFIED
3. WEB MEMBERS, ( DIAGONAL ) = Ø76.1, TO BE VERIFIED ENTRANCE GATE
GUARD HOUSE
NOTES :
ENTRANCE SHADE SPACE FRAME SYSTEM
1. OTHER DETAILS NOT SHOWN, REFER TO AR-DWGS.
PLAN & DETAILS
2. FOR THE JOINTS CONNECTION DETAILS, MUST BE IN
IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD DWGS.
IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD DWGS.
AFG AFG
ACCU
FCU
EXIT
ENTRY
ENTRY
EXIT
EXIT
ENTRY
ENTRY
ENTRY
PROPOSED DU
CT BANK ( DIS
TANCE =
500m )
1) 10 PAIRS INCLUDED :
TEL CABLE ( BY
2) 12 CORE S OTHER )
INGLE MODE
FIBER OPTICE
( BY OTHER )
OAD
INSIDE ONE (1
10mm DIA. PV
C PIPE IN
CONCRETE
& 32mm DIA H
DPE SUBDUCT
R
CONCRETE( SP
ARE)
TO EXISTING P
OINT
PROPOSED M.V
CA
3CX185mm2 CU/X BLE 15KV
LPE/SWA
( DISTANCE = 200m /PVC
)
PROPOSED L.V CABLE (D.B PROPOSED SU TO EXISTING
3.5CX25 mm2CU/XLPE/SW
) 500KVA STEP DO B STATION CONNECTION PO
A/PVC+ WN TRANSFORM INT
16mm2CU.(E) 13.8 KV/380V, 3P ER
HASE, 60HZ, OIL PROPOSED M.V CABLE
PB/GH
ELECTRICA
( DISTANCE = 40m ) IMMERSED TYPE 15KV
SIDEWALK
3CX185mm2 CU/XLPE/
LLY OPERA
EXIT
TED BARR
IER
SWA/PVC
( DISTANCE = 200m )
GUARD
ROOM
ELECTRICA
LLY OPE RATED BA
RR IER
CONNECTED TO
EXISTING
F-6
16mm2CU.(E) ( DISTANCE = 40m )
F-5
F-4
F-3
F-3
3.5CX25 mm2CU/XLPE/SWA/PVC+
PB/GH
A MAIN POWER SINGLE LINE DIAGRAM
- NTS
ENTRANCE GATE
ENGR.HOSSAM ENGR.HOSSAM
ELE.ENG/A.SAMIR
1:200 2019
T xx 8210 XE01
1 2 NOTES:
1 2
6 3
4-22A02 4-22A02
EXPOSED CONCRETE
RAMP w/HARDENER
6 3
4-22A02 4-22A02
RAMP DN
A D01 A
PUMP
ROOM
4-22 01
2 4 2 4
EL. 000.000
4-22A02 4-22A02 4-22A02 4-22A02
GRD F.F.L.
CONCRETE PAD
SLOPE TO
DRAIN 1% MIN.
6 1 6 1
4-22A02 4-22A02
4-22A02 4-22A02
DOOR SCHEDULE
1 2 3 4 5 6 7 8 9
PUMP
ROOM
4-22 01
B
CEMENT PLASTER
CEMENT PLASTER
EF
01 PUMP ROOM
NOTES:
1 2 A B
600
600
SMOOTH PAINTED (TYP)
EL. +3000 EL. +3000
TOP OF ROOF SLAB TOP OF ROOF SLAB
3600
3600
3000
3000
EL. 00.000 EL. 00.000
FIN. FLR. LINE FIN. FLR. LINE
EL. -150.000 EL. -150.000
TOP OF SIDEWALK TOP OF SIDEWALK
2 1 B A
LIGHTING FIXTURE
600
EL. +3000 EL. +3000
TOP OF ROOF SLAB CEMENT PLASTER TOP OF ROOF SLAB
2000 TEXTURED PAINTED (TYP)
3600
3600
3000
3000
2200
1 2 A B
LOOSE GRAVEL ( 50mm ) LOOSE GRAVEL ( 50mm )
PROTECTION LAYER PROTECTION LAYER
RIGID THERMAL INSULATION ( 50mm ) RIGID THERMAL INSULATION ( 50mm )
SEPARATION LAYER SEPARATION LAYER
WATER PROOFING MEMB. WATER PROOFING MEMB.
LIGHT WEIGHT CONC. ( SLOPED ) LIGHT WEIGHT CONC. ( SLOPED )
REINFORCED CONCRETE ROOF SLAB REINFORCED CONCRETE ROOF SLAB
EL. +3600 EL. +3600
TOP OF PARAPET TOP OF PARAPET
600
600
EL. +3000 EL. +3000
TOP OF ROOF SLAB TOP OF ROOF SLAB
EXIT LAMP
3600
3600
3000
3000
PUMP
ROOM 600X600 MANHOLE
GALVANIZED STEEL
2200
4-22 01
ACCESS PANEL
PUMP W/ CONC. UP STAND
ROOM
4-22 01
MILITARY AUTHORITIES.
400
ORIENTATION
1 2 1 2
200
5000 5000 1. FOR STRUCTURE ORIENTATION, REFER TO THE LATEST SITE PLAN.
100 4800 100 100 4800 100
1300 2400 1300 PLANTED COLUMN, PC1
WITH 6 ∅14, VERT. REBARS
200 THK. RAMP-UP GRADE SLAB
RAMP UP
AND ∅8 c200, LATERAL TIES
W/ ∅12 c200, SHORT BTM. REBARS 700
TOP ELEV.
2400
AND ∅12 c200, LONG BTM. REBARS 100 100 RC. PARAPET WALL (+3600)
REFER TO GS-06
700
700
RB1
PC1(200x400) PC1(200x400) (200x400)
100
100
REFERENCE DRAWINGS
100
100
A A
WFE
∅10 c200, T
(-150)
∅10 c300, T DWG. NO. DRAWING TITLE
WFE ∅12 c150, B ∅10 c150, B NOTE:
(-150) GS 01 CIVIL & STRUCTURAL STANDARD NOTES
∅12 c150, B
∅10 c150, B
∅10 c200, T
∅10 c300, T
(200x400)
(200x400)
SSE 300 THK. RC. WALL, TYP. SSE THE FOLLOWING SHALL BE USED:
RB1
RB1
4800
4800
5000
5000
(000) (+3000)
WITH ∅16 c150, VERT. REBARS
DECK ROOF RB1, (200x400) CE 01 MASTER SITE DEVELOPMENT , CIVIL/STRUCTURAL PLAN
PUMP HOUSE AND ∅16 c200, HORZ. REBARS
600 (120 THK. SLAB) WITH 2 ∅16, BTM. REBARS
(200 THK. SLAB)
CAST IRON MEDIUM DUTY WITH 2 ∅14, TOP REBARS REINFORCED CONCRETE LINED CANAL-1 & 3
AND ∅10 c200, STIRRUPS, THROUGHOUT
CE 02
MANHOLE COVER & FRAME STRUCTURAL SECTIONS- A & B
600
CASE-1 & 2, REINFORCED CONCRETE LINED CANAL-2
B B
100
100
100
100
CE 03
PC1(200x400) PC1(200x400) RB1 STRUCTURAL SECTION-C
700
700
(200x400)
100 100 REINFORCED CONCRETE TYP. ROADS CATCH BASINS
CE 04
700 700 STRUCTURAL SECTIONS AT CB-1, CB-2 & CB-3
REINFORCED CONCRETE BOX CULVERTS - 1 TO 3
∅25 c300, STAINLESS STEEL RUNGS CE 05
ENLARGED SETTING OUT PLANS
REINFORCED CONCRETE BOX CULVERTS - 4 TO 7
CE 06
ENLARGED SETTING OUT PLANS
REINFORCED CONCRETE BOX CULVERTS - 8 TO 11
CE 07
ENLARGED SETTING OUT PLANS
- GROUND FLOOR FRAMING PLAN - DECK ROOF FRAMING PLAN CE 12 CATCHMENT POND-1, ENLARGED SETTING-OUT PLAN
- SCALE 1:100 - SCALE 1:100
CE 13 CATCHMENT POND-2 & 3, ENLARGED SETTING-OUT PLAN
1 2 1 2 4
5200 3
5000
200 4800 200 100 4800 100 2
1
200 THK. PROTECTION CMU WALL 0 PRELIMINARY ISSUE DEC., 2018
10 THK. PROTECTION BOARD
2 LAYERS OF A 4mm THK. WPM
REVISIONS SUBJECT DATE
200 200
300 THK. RC. WALL
100 100
200
100
100
100
A A
400
400
PC1 PC1
∅10 c200, T (200x400) (200x400)
∅12 c150, B
SSE
∅10 c200, B
∅12 c150, T
4800
5000
4800
5200
(-6000) 300 THK. RC. WALL, TYP. 300 THK. RC. WALL, TYP.
UNDERGROUND WITH ∅16 c150, VERT. REBARS WITH ∅16 c150, VERT. REBARS
600 AND ∅16 c200, HORZ. REBARS
WATER TANK 100
AND ∅16 c200, HORZ. REBARS
(300 THK. BASE SLAB) 600x600x600 SUMP PIT PC1 PC1
300, TYP.
600
300, TYP.
(200x400) (200x400)
5 / 5 / 37
400
400
100
B B
100
100
100
200
100 100
300, TYP. 200 200
300, TYP.
STORM WATER DRAINAGE SYSTEM
REFERENCE DRAWINGS
1 2
5000
RAMP UP
A
WFE
(-150)
WFE
(-150)
4800
5000
PUMP HOUSE
SSE
(000)
600
CAST IRON MEDIUM DUTY
MANHOLE COVER & FRAME
600
B
CLASS OF FIRE
PORTABLE FIRE EXTINGUISHER SCHEDULE
1. A-SOLID MATTERS FORMING RESIDUES
e.g, WOOD, RUBBER (CAR TIRES), PAPER, TEXTILES.
EXTINGUISHING CLASS OF TOTAL WEIGHT CAPACITY WORKING
PFE NO. QTY LOCATION PRESSURE PROPELLING AGENT 2. B-LIQUID COMBUSTIBLE MATTER e.g. PETROL, OILS,
AGENT FIRE ( Kgs.) ( Kgs.) GREASE, ETHER, ALCOHOL.
( BAR )
3. C- BURNING GASES EMERGING UNDER PRESSURE
PFE-1 2 DRY CHEMICAL CO 2 9.4 6 12-15 CO 2 e.g. PROPENE,BUTANE, METHANE, ACETYLENE, TQWEN GAS.
4. E- FIRE ON ELECTRICAL PLANTS.
NOTES:
REFERENCE DRAWINGS
1 2
5000
4800
RAMP UP
A
WFE
(-150)
WFE
(-150) PUMP HOUSE
SSE
4800
5000
(000)
600
CAST IRON MEDIUM DUTY
MANHOLE COVER & FRAME
600
B
100
100
100
PC1(200x400) PC1(200x400)
700
700
100 100
700 700
1 2
5000
4800
A
DECK ROOF
RD
RAMP UP
A
∅200 PUMP HOUSE WFE
(-150)
∅200
BV BV BV
4800
5000
CV CV CV CONTROL PANEL
EJ EJ EJ
B
EF-1
PUMPS SCHEDULE
UNIT SERVICE QTY. TYPE FLOW HEAD POWER ELECTRICAL DATA REMARKS
NO. (GPM/(m3/hr) (FT/m) (HP/KW)
- SCHEDULE OF EQUIPMENTS
- SCALE: NTS
RAMP UP
CONTROL PANEL
CONTROL PANEL
5-5-37
AFG AFG
- AFG
STAINLESS STEEL RUNGS
TRANSFER PUMPS NTS DECEMBER , 2018
D - - EL01